首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Summary The use of mciroparticulate guard columns in conjunction with high efficiency reverse-phase columns has been evaluated in terms of system efficiency and peak symmetry using three standard test mixtures. The effects of linking tube dimensions, particle size of guard column packing and the use of low or zero dead volume couplings have been investigated. Both valve and stopped-flow injection techniques have been used. Recommendations are given for the most efficient use of guard columns.  相似文献   

3.
4.
We report on a series of flow velocity and efficiency profiles, which were measured across the cross section of preparative chromatographic columns packed with different stationary phase materials using computed tomography. It is shown that this non-invasive technique is very useful for visualization of the inner part of a packed column and measurement of the spatial resolved column packing properties. For evaluation of the influence of the particle shape on the velocity distribution and column performance, irregular and spherical reversed phases were studied in detail. The results showed a decreasing velocity towards the column wall most certainly due to a lower permeability. This effect was much less pronounced in the case of spherical particles, indicating a more homogenous packing structure. The influence of the column packing pressure, as a possible measure for improvement of the packing homogeneity was also studied. It was shown that under the same packing conditions spherical particles always lead to a more homogeneous packing. The overall results of this work contribute to the origin of the fact that spherical material is superior to irregular one from the hydrodynamic point of view.  相似文献   

5.
Summary Some quantitative implications of the use of microbore columns in column liquid chromatography are investigated. Although for several pumps the flow rate stability at 50 l min–1 is slightly worse than that of pumps operating at 1 ml min–1, the quantitative performance with respect to repeatability and reproducibility of response factors equals that of conventional liquid chromatography. Thermostatting is strongly recommended for microbore column operation.  相似文献   

6.
Summary An automatic liquid sampler for high-performance liquid chromatography is described.The sampler is based on a GC-injection system from Hewlett-Packard. The HPLC sampler has a unique cleaning system, excellent reproducibility and a plug-in compatibility for sample identification and computer control for Hewlett-Packard integrators and Laboratory Data Systems.  相似文献   

7.
Eleven cyanopropyl ("cyano") columns were characterized by means of a relationship developed originally for alkyl-silica columns. Compared to type-B alkyl-silica columns (i.e., made from pure silica), cyano columns are much less hydrophobic (smaller H), less sterically restricted (smaller S*), and have lower hydrogen-bond acidity (smaller A). Because sample retention is generally much weaker on cyano versus other columns (e.g., C8, C18), a change to a cyano column usually requires a significantly weaker mobile phase in order to maintain comparable values of k for both columns. For this reason, practical comparisons of selectivity between cyano and other columns (i.e., involving different mobile phases for each column) must take into account possible changes in separation due to the change in mobile phase, as well as change in the column.  相似文献   

8.
全多孔球形硅胶基质高效液相色谱填料研究进展   总被引:3,自引:0,他引:3  
蒋生祥  刘霞 《中国科学B辑》2009,39(8):687-710
结合本实验室的研究工作,评述了以全多孔球形硅胶为基质的正相反相色谱填料、手性色谱填料、离子色谱填料以及核一壳型色谱填料的研究进展.  相似文献   

9.
The need for novel packing materials in both capillary electrochromatography (CEC) and capillary liquid chromatography (CLC) is apparent and the development towards more selective, application-oriented chromatographic phases is under progress world-wide. In this study we have synthesized new polyethyleneimine (PEI) functionalized Mn(2)O(3), SiO(2), SnO(2), and ZrO(2) particles for the fabrication of packed capillary columns for CEC and CLC. The nanocasting approach was successful for the preparation of functionalized metal oxide materials with a controlled porosity and morphology. PEI functionalization was done using ethyleneimine monomers to create particles which are positively charged in aqueous solution below pH 9. This functionalization allowed the possibility to have both hydrophobic (due to its alkyl chain) and ionic interactions (due to positively charged amino groups) with selected compounds. For comparison aminopropyl-functionalized silica was also synthesized and tested. Both slurry pressure and electrokinetic packing procedures used gave similar results, but fast sedimentation of the material caused some problems during the packing. The high stability and wide pH range of PEI-functionalized SiO(2) material, with potential for hydrophobic and electrostatic interactions, proved to be useful for the CEC and CLC separation of some model acidic and neutral compounds.  相似文献   

10.
Capture columns are important interface tools for on line two-dimensional liquid chromatography (2D-LC). In this study, a systematic method was developed to evaluate and optimize the capture ability of capture columns by off-line method. First, the parameter ΔtRtR = t2t1t0W) was introduced to quantitatively represent the capture ability of the capture column by connecting a capture column behind the first dimensional column. Based on the value of ΔtR, an appropriate capture column was selected after the first dimensional column was fixed. Then, the capture ability of the selected column was promoted by adjusting the mobile phase of the first dimensional column. Capture ability was also optimized using complex sample analysis software system (CSASS) software. Second, the elution mode of the trapped compounds on the capture column was investigated by connecting the capture column before the second dimensional column. More specifically, in mode I, capture column was connected to the second dimension without changing the flow rate direction and the trapped compounds must pass through the capture column and be eluted into the second dimensional column. The contrary connection mode was mode II. It was found that mode I is more suitable method for 2D-LC. Finally, an off-line reversed-phase/hydrophilic interaction liquid chromatography two-dimensional liquid chromatography (RP/HILIC 2D-LC) system with a C18 capture column was developed to demonstrate the practical application of this method.  相似文献   

11.
The theoretical advantages and drawbacks of using a multiple-, parallel column approach in on-line multidimensional liquid chromatography systems were investigated. Much time or peak capacity can be gained with the use of multiple parallel columns at the second-dimension while the aggregate time of separation increases only by the increment of the gradient time of the second-dimension. Multidimensional chromatographic systems are now used to perform many tasks ranging from routine, fast analyses to specialized, arduous separations. In this work, we focus on the advantages of a multiple, parallel columns approach to on-line multidimensional liquid chromatography systems. Calculations of the achievable peak capacities were made as functions of the number of columns operated in parallel. Increasing the number of second-dimension columns from one to two or three causes the largest increase in peak capacity with only a slight increase of aggregate time. We also present some practical aspects to consider when attempting multidimensional separations with multiple columns operated in parallel.  相似文献   

12.
Summary The retention volume dependences on the molar volume were found for aromatic compounds using liquid microcolumn chromatography. The contributions of the functional groups in molecules of these compounds to the total retention value were calculated from the capacity factor values. The comparison of capacity factor values for carbon sorbents and octadecyl-silicagel has shown that for several microcolumn separations the carbon sorbent column has a better selectivity and resolution than the octadecyl-silicagel column.  相似文献   

13.
A procedure is described by which 20 commonly occurring amino acids may be separated by reversed-phase liquid chromatography at room temperature in a total time, including derivatisation with o-phthalaldehyde/2-mercaptoethanol reagent, of approximately 15 minutes. Further, an increase in column temperature enables increased resolution of certain amino acids to be obtained with small but acceptable losses in fluorescence intensity. The only major drawback to the method is that the derivatisation reagent does not react with proline or hydroxyproline.  相似文献   

14.
D. Barceló 《Chromatographia》1988,25(10):928-936
Summary The use of liquid chromatography in environental pesticide analysis is reviewed. In addition to classical UV and electrochemical detectors, detection systems such as mass spectromytry and gas chromatographytype detectors are discussed. The applicability of supercritical fluid chromatography to pesticide analysis is also reviewed.Presented at the 18th International Symposium on Environmental Analytical Chemistry, Barcelona 5–8 September, 1988.  相似文献   

15.
杜苑琪  肖小华  李攻科 《色谱》2018,36(7):579-587
衍生化是将待分析物转化为更适合的物质形式以便于分析的有效手段。原位衍生化技术作为一种常用的柱前衍生化方法,可以在样品基质中同时完成分析物的萃取和衍生化,具有高效、灵敏和选择性好的优点。原位衍生化结合其他前处理技术广泛用于胺类、醛酮类、醇类、酚类、羧酸和巯基化合物的分析中,在生物、药物、食品、环境、化妆品分析等领域有广泛的应用。该文概述了原位衍生化的反应类型和代表性衍生试剂,综述了原位衍生化技术在液相色谱和液相色谱-质谱联用分析中的应用,并展望其发展趋势。  相似文献   

16.
A fast method using high-performance liquid chromatography based on two monolithic columns has been developed for the simultaneous determination of isoflavones extracted from soybeans and derived foods. The 12 main isoflavones were resolved in 10 min in two coupled monolithic columns working at 35 °C using a elution gradient of acidified water (0.1% acetic acid) and methanol (0.1% acetic acid) at a flow rate of 5 mL min−1. Retention time and relative area standard deviations were below 1% for all isoflavones. The method developed was successfully applied to several soy food samples and spiked samples. Total isoflavone concentration in sampled soy foods ranged from 34.28 mg L−1 to 4.29 mg g−1.  相似文献   

17.
Simulated moving columns technique for chiral liquid chromatography   总被引:1,自引:0,他引:1  
Enantioselectivity of chiral selectors is often relatively low in chiral HPLC. For difficult chiral separations, often only partial resolution is obtained rather quickly by column and mobile phase screening, and, by trial-and-error, additional method optimization is required to achieve complete resolution. This paper describes the development of a novel column-switching technique called "simulated moving columns" (SMC) to quickly achieve complete chiral resolution on columns with limited enantioselectivity. The simulated moving columns (SMC) technique uses two (2) or three (3) short chiral HPLC columns connected in series, and forces the unresolved enantiomers to recycle exclusively through the columns until sufficient resolution is attained. In effect, SMC helps to achieve chiral resolution by virtually multiplying the column length, thus enhancing separation efficiency and resolution, without increasing backpressure. Comparison of the standard non-SMC approach with SMC, and selected applications of chiral separations of pharmaceutical drug molecules are presented. Through measurement and calculation, evaluation of off-column band broadening resulting from a two-column SMC system is provided. The results clearly indicate that SMC eliminates the significant band broadening that is inevitable in the closed-loop recycling techniques currently used in preparative chromatography. Furthermore, SMC is not only useful to enhance resolution for analytical and preparative chiral separation, but also has great potential to enhance recovery and purity for difficult chiral preparative chromatography.  相似文献   

18.
Ultra-high-pressure liquid chromatography (UHPLC) using columns packed with sub-2 μm particles has great potential for separations of many types of complex samples, including polymers. However, the application of UHPLC for the analysis of polymers meets some fundamental obstacles. Small particles and narrow bore tubing in combination with high pressures generate significant shear and extensional forces in UHPLC systems, which may affect polymer chains. At high stress conditions flexible macromolecules may become extended and eventually the chemical bonds in the molecules can break. Deformation and degradation of macromolecules will affect the peak retention and the peak shape in the chromatogram, which may cause errors in the obtained results (e.g. the calculated molecular-weight distributions). In the present work we explored the limitations of UHPLC for the analysis of polymers. Degradation and deformation of macromolecules were studied by collecting and re-injecting polymer peaks and by off-line two-dimensional liquid chromatography. Polystyrene standards with molecular weight of 4 MDa and larger were found to degrade at UHPLC conditions. However, for most polymers degradation could be avoided by using low linear velocities. No degradation of 3-MDa PS (and smaller) was observed at linear velocities up to 7 mm/s. The column frits were implicated as the main sources of polymer degradation. The extent of degradation was found to depend on the type of the column and on the column history. At high flow rates degradation was observed without a column being installed. We demonstrated that polymer deformation preceded degradation. Stretched polymers eluted from the column in slalom chromatography mode (elution order opposite to that in SEC or HDC). Under certain conditions we observed co-elution of large and small PS molecules though a convolution of slalom chromatography and hydrodynamic chromatography.  相似文献   

19.
Summary A sensitive HPLC method has been developed for determination of ofloxacin (OFL) in biological fluids. Sample preparation was performed by adding phosphate buffer (pH 7.4, 0.1m) then extraction with trichloromethane. OFL and the internal standard, sarafloxacin (SAR), were separated on a reversed-phase column with aqueous phosphate solution-acetonitrile, 80∶20, as mobile phase. The fluorescence of the column effluent was monitored at λex 338 and λem 425 nm. The retention times were 2.66 and 4.24 min for OFL and SAR, respectively, and the detection and quantitation limits were 8 and 15 ng mL−1, respectively. Plots of response against ofloxacin concentration were linear in the range 8 to 2000 ng mL−1. Recovery was 92.9% for OFL.  相似文献   

20.
A novel monolithic capillary column (530 microm i.d.) was prepared for capillary liquid chromatography (CLC) by in situ copolymerization of octyl methacrylate (MAOE) and ethylene dimethacrylate (EDMA) in the presence of a porogen solvent containing 1-propanol, 1,4-butanediol, and water with azobisisobutyronitrile as the initiator. The influences of the contents of the porogen solvent, EDMA and the various concentration ratios of 1-propanol to 1,4-butanediol in the polymerization mixture on the morphology, porosity, globule size, stability and column efficiency were investigated. The morphology and pore size distribution of monolithic capillary columns were characterized by SEM and mercury intrusion porosimetry, respectively. Chromatographic evaluations of the columns were performed under CLC mode. The results showed that good permeability and stability can be obtained under optimal experimental conditions. The separation results of some acid, neutral and basic analytes demonstrated the hydrophobicity and low affinity to basic analytes of the new column. Three metal ions, i.e. Mg(II), Zn(II) and Cd(II) were also separated under ion-pair mode on the new monolithic capillary column and the results were acceptable.  相似文献   