首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
Bipolar electrode (BPE) focusing is a developing technique for enrichment and separation of charged analytes in a microfluidic channel. The technique employs a bipolar electrode that initiates faradaic processes that subsequently lead to formation of an ion depletion zone. The electric field gradient resulting from this depletion zone focuses ions on the basis of their individual electrophoretic mobilities. The nature of the gradient is of primary importance to the performance of the technique. Here, we report dynamic measurements of the electric field gradient showing that it is stable over time and that its axial position in the microchannel is directly correlated to the location of an enriched tracer band. The position of the gradient can be tuned with pressure-driven flow. We also show that a steeper electric field gradient decreases the breadth of the enriched tracer band and therefore enhances the enrichment process. The slope of the gradient can be tuned by altering the buffer concentration: higher concentrations result in a steeper gradient. Coating the channel with the neutral block co-polymer Pluronic also results in enhanced enrichment.  相似文献   

2.
马思渝  傅孝愿 《化学学报》1993,51(5):496-501
N-4-甲基-4-戊烯基硝酮分子内环加成反应可以生成氧桥型(Pa)和碳桥型(Pb)两种产物, 其实验产率比约为8:1。而在N-4位未取代的情况下, Pa与Pb的实验产率比约为1:2。可见N-4-甲基使得区域选择性发生了很大的变化。本文用AM1 MO方法和过渡状态理论研究了N-4-甲基-4-戊烯基硝酮分子内环加成反应的机理。计算了两个平行反应(a, b)的速率常数的比值, 得到与实验吻合的结果。计算表明, N-4-甲基取代后, a, b两反应的活化熵的相对变化是区域选择性改变的主要因素, 活化焓的相对变化只是一个次要因素。  相似文献   

3.
Gradient colloidal crystals with a thickness gradient were prepared by the vertical deposition technique with vertically graded concentration suspensions. The thickness of the gradient colloidal crystal gradually changes at different positions along the specific gradient direction of the crystal. The thickness gradient was determined by the concentration gradient, depending on the initial colloidal concentration and the settling time. The optical transmission intensity at the dip wavelength can be tuned by changing the thickness of the colloidal crystals. The gradient colloidal crystals lead to a gradient of optical intensity at the dip in transmission light. The gradient of optical intensity at the dip increases as the thickness gradient of the colloidal crystal increases.  相似文献   

4.
A series of 3-n-alkyl substituted poly(4-hydroxybenzoates) were prepared by melt-polycondensation of the corresponding monomers. The length of the alkyl side chains was varied in the range of 3 to 18 carbon atoms. The average degree of polymerisation (DP) was determined by 1H NMR end-group analysis. The thermal behavior of the polymers was studied by differential scanning calorimetry (DSC) and polarising microscopy (PM). Structural investigations of oriented and not oriented samples were performed by means of wide angle X-ray scattering (WAXS). The density of the polymers was measured by gradient column technique.  相似文献   

5.
A method to measure the stress field at the fiber tip in the fiber pull out test was proposed by using a digital gradient sensing technique. First, the principle of digital gradient sensing is introduced, and the non-contact optical system of digital gradient sensing developed. Then, a fiber reinforced composite model specimen, where a nail was inserted in epoxy resin to act as a fiber, was performed, and a pull out test was conducted on the specimen using the digital gradient sensing technique. Finally, the angular deflections contour at the fiber tip was obtained, and the stress intensity factor was extracted from the angular deflections. The results show that the stress intensity factor at the fiber tip extracted from the angular deflections agreed with the results calculated by the finite element method.  相似文献   

6.
Sulphadimethoxine is metabolized in humans by N1-glucuronidation and by N4-acetylation. Sulphadimethoxine-N1-glucuronide can be measured by the direct high-performance liquid chromatographic analysis and without enzymic deglucuronidation. The N1-glucuronide can be measured by an isocratic as well as by a gradient mobile phase. The group contribution of the N1-glucuronide moiety to the capacity factor is a reduction of 0.24 in the isocratic system and 0.55 in the gradient system. N4-Acetylation increases the capacity factor by a factor 1.4 in the isocratic system and by 1.06 in the gradient system.  相似文献   

7.
Synthetic graphite?Cphenolic nanocomposites were designed and synthesized with a compositional gradient which is shown to influence transient temperature fields during rapid temperature changes. Such nanocomposites were fabricated using a compression moulding technique, and thermal conductivity and heat capacity of nanocomposites were experimentally determined using a modified transient plane source technique over a wide temperature range from 253.15 to 373.15?K. The effects of four compositional gradient configurations on the transient temperature field across the thickness of a nanocomposite plate, at a high imposed temperature, was investigated. The transient time and temperature fields in nanocomposite structures were highly affected by the compositional gradient configurations.  相似文献   

8.
Bound GP  Fleet B 《Talanta》1980,27(3):257-261
A novel system for semi-automated potentiometric analysis by gradient titration has been devised. In this technique both the reagent gradient generation and the titration are carried out in the sample container. The determination of chloride ion, with two ion-selective electrodes used simultaneously as an end-point sensor, is chosen to illustrate the technique.  相似文献   

9.
A hydrophobic to hydrophilic gradient surface was prepared using the tuned photodegradation of an alkylsilane self-assembled monolayer (SAM) using irradiation of vacuum ultraviolet light (wavelength=172 nm). The water contact angle on the photodegraded SAM surface was adjusted using the intensity and time photoirradiation parameters. The formation of a gradient was confirmed by fluorescent labeling. The water drop moved from the hydrophobic to hydrophilic surface with a velocity that depended on the gradient. The higher the gradient, the faster the water moved. For the first time, we have prepared a gradient surface using photodegradation where the movement of a water drop was regulated by the degree of gradation. Considering that the photodegradation technique can be applied to various surfaces and to lithography, this technique will be useful for various material surfaces.  相似文献   

10.
The treatment presented in a recent paper [P. Nikitas, A. Pappa-Louisi, J. Chromatogr. A, 1068 (2005) 279] is extended to multilinear gradients, i.e. continuous gradients consisting of a certain number of linear portions. Thus, the experimental lnk versus phi curve, where k is the retention factor of a sample solute under isocratic conditions and phi is the volume fraction of the organic modifier in the water-organic mobile phase, is subdivided into a finite number of linear portions resulting in simple analytical expressions for the solute gradient retention time. These expressions of the retention time are directly used in an optimisation technique based on genetic algorithms. This technique involves first the determination of the theoretical dependence of k upon phi by means of gradient measurements, which in turn is used by the genetic algorithm for the prediction of the best gradient profile. The validity of the analytical expressions and the effectiveness of the optimisation technique were tested using fifteen underivatized amino acids and related compounds with mobile phases modified by acetonitrile. It was found that the adopted methodology exhibits significant advantages and it can lead to high quality predictions of the gradient retention times and optimisation results.  相似文献   

11.
This technical note describes a new bench-top method for producing anisotropic hydrogels composed of gradient layers of soluble factors, particles, polymer concentrations or material properties. Each gradient layer was produced by a previous gradient method in which a droplet of one precursor solution was added to a thin layer of a second solution. The ensuing rapid capillary flow along the open channel generated a gradient precursor solution, which was then crosslinked to form a gradient gel. Repeating these steps allowed a layered gel to be iteratively constructed with as many gradient layers as desired. This technique renders the synthesis of multi-layered gradient gels accessible to virtually any researcher and should help simplify the production of more biologically relevant cellular microenvironments.  相似文献   

12.
A recently proposed orthonormality constrained orbital optimization technique is operationally modified further by coupling it to a gradient biased method, namely the steepest descent procedure of McWeeny. The hybrid technique developed in this way is shown to have better convergence properties in closed and unrestricted open-shell calculations. The technique can be adapted to MCSCF procedures as well. The important role played by "orbital symmetries" in the operation of the method is analysed. Similarities and differences of the present method with the orthogonal gradient method are pointed out. Possible avenues of circumventing convergence difficulty that one may encounter in pathological cases, particularly in ab initio calculations involving extended basis set, are suggested.  相似文献   

13.
A gradient reversed-phase high-performance liquid chromatographic technique is described for the facile separation and quantitation of the naturally occurring retinoids: retinoic acid, retinol, and retinyl esters. An octadecylsilane column (Waters mu Bondapak C18) is used, with gradient elution from methanol--water (80:20) (solvent A) to 70% or 100% methanol--tetrahydrofuran (50:50) (solvent B) at 2.0 ml/min; detection is by absorbance at 325 nm. Analysis can be completed, with return to starting conditions, in 25-30 min. The method is inherently flexible: retinyl esters can be eluted as a group, with little resolution, by gradient to 100% solvent B, or mostly resolved by gradient to 70% solvent B; separation of retinoids more polar than retinoic acid can be achieved by use of greater proportions of water in solvent A. The separation of vitamin A compounds from extracts of human, rat, and pig liver and from rat kidney by this technique is described.  相似文献   

14.
The conformational space of 1C4 α-L-fucose was searched by the MM2*-SUMM molecular mechanics conformational search technique. The molecular geometries of the first 17 structures of lowest energy were analyzed at the HF/3-21G, 6-31G(d), and generalized gradient approximation (GGA) DFT levels of theory. © 1997 by John Wiley & Sons, Inc.  相似文献   

15.
In this letter, we present a simple yet novel method, Langmuir-Blodgett (LB) rotating transfer, to achieve a continuous gradient mesostructure in a well-ordered fashion over large areas. A mixed monolayer of phospholipid and dye is chosen as a model system to test the feasibility of LB rotating transfer to fabricate continuous gradient structures, which is confirmed by the simulation and experimental results. The technique presented here to obtain gradient structures is low-cost and high-throughput and can be extended to other systems of LB patterning.  相似文献   

16.
A fully automated gradient high-performance liquid chromatographic method for the determination of isotretinoin, tretinoin and their 4-oxo metabolites in plasma was developed, using the column-switching technique. After dilution with an internal standard solution containing 20% acetonitrile, 0.5 ml of the sample was injected onto a precolumn (17 X 4.6 mm I.D.), filled with C18 Corasil 37-53 micron. Proteins and polar plasma components were washed out using 1% ammonium acetate-acetonitrile (9:1, v/v) as mobile phase 1. After valve switching, the retained components were transferred to the analytical column in the backflush mode, separated by gradient elution and detected at 360 nm by UV detection. Using two coupled reversed-phase columns (125 mm long), the separation of cis and trans isomers was possible, and all four compounds could be quantified down to 2 ng/ml of plasma. The inter-assay precision in the concentration range 20-100 ng/ml was between 1.0 and 4.7% for all compounds.  相似文献   

17.
用MINDO/3方法求出了N-4-戊烯基硝酮分子内环加成反应的过渡态和反应途径.两个环加成区域异构体是由N-4-戊烯基硝酮的两个不同的构象经过各自的过渡态得到的. 理论分析满意地解释了实验结果.  相似文献   

18.
Gradient chromatofocusing is a recently developed chromatographic technique that overcomes the limitations of conventional chromatofocusing. This technique employs a HPLC gradient system and simple low-molecular-mass buffer components to generate linear or other function pH gradients on ion-exchange columns. Results of the present work show a superior separation of beta-lactoglobulin A and B in gradient chromatofocusing compared to salt gradient chromatography using the same DEAE column, with an optimized resolution of 2.3 obtained with gradient chromatofocusing compared to 1.1 obtained with NaCl gradients at constant pH. A significant advantage of the gradient chromatofocusing technique over the conventional chromatofocusing technique is its ability to employ a relatively wide range of buffer concentrations in the mobile phase, the effect of which is studied in the present work. Five proteins (conalbumin, ovalbumin, bovine serum albumin, beta-lactoglobulin A and B) are chromatographed on a DEAE-polymethacrylate HPLC anion-exchange column using the same approximately linear pH gradient profile but different mobile phase buffer concentrations. Results show a significant effect of buffer concentration on peak width, separation factor and resolution. For example, resolution increases from 1.5 to 2.3 in the separation of beta-lactoglobulin A and B when the concentration of each of the components in the 100% elution buffer is increased from 6.25 to 25.0 mM (with the same outlet pH gradient). This separation trend is also seen in the chromatography of ovalbumin from a commercial source, noting a progressive increase in resolution of two peaks in the sample (resolution increased from 0.7 to 2.4) when the concentration of each of the components in the 100% elution buffer is increased from 6.25 to 37.5 mM (same outlet pH gradient). The gains in the resolution are attributed to an increase in the separation factor, since the peak widths are generally noted to also increase with increased buffer concentration. These results point to a significant interplay between buffer concentration and pH, which is not effectively exploited in either conventional chromatofocusing or in conventional ion-exchange chromatographic procedures employing salt gradient elution at constant pH. Gradient chromatofocusing has the ability of optimizing both parameters, thus providing it with unique capabilities in protein separations.  相似文献   

19.
王琴孙  高如瑜 《分析化学》1994,22(5):495-498
本文介绍了计算机辅助反相高效液相色谱梯度洗脱优化分离的方法。首先采用混合设计法,通过9个预试验建立目标函数,然后运用双因素(初始流动相组成C和梯度时间T)扫描技术,由计算机给出优化分离条件,实验结果和预示完全一致。  相似文献   

20.
Summary A computer-assisted method is presented for the optimization of separation in gradient elution reversed-phase HPLC. The method is based on a polynomial estimation from nine preliminary experiments according to a two-factor (initial solvent composition C and gradient time T) rectangular design. This is followed by a two-dimension computer scanning technique. Resolution is used as the selection criterion. Good agreement was obtained between predicted data and experimental results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号