首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A reversed-phase high-performance liquid chromatography (HPLC) method with gradient elution for the separation of angiotensin peptides is described. The highly reproducible method allows the base-line separation of angiotensin peptides with UV detection at 225 nm. This chromatographic methodology in combination with radioimmunoassay (RIA) is used for the characterization of angiotensin peptides in human plasma and sweat.  相似文献   

2.
A rapid and accurate method is described for the determination of prolyl peptides in urine, with specific reference to the dipeptide prolylhydroxyproline, and free hydroxyproline and proline. Free amino acids and peptides were isolated from urine on cation-exchange minicolumns, and free imino acids and prolyl-N-terminal peptides were selectively derivatized with 4-chloro-7-nitrobenzofurazan, after reaction of amino acids and N-terminal aminoacyl peptides with o-phthalaldehyde. The highly fluorescent adducts of imino acids and prolyl peptides were separated on a Spherisorb ODS 2 column by isocratic elution for 12 min using as mobile phase 17.5 mM aqueous trifluoracetic acid solution containing 12.5% acetonitrile (eluent A), followed by gradient elution from eluent A to 40% of 17.5 mM aqueous trifluoroacetic acid solution containing 80% acetonitrile in 20 min. Analytes of interest, in particular the dipeptide prolylhydroxyproline, can be easily quantified by fluorimetric detection (epsilon ex = 470 nm, epsilon em = 530 nm) without interference from primary amino-containing compounds.  相似文献   

3.
A HPLC method for the quantitative determination of 5-hydroxy-3-indoleacetic acid (5-HIAA) in urine is described. The method is based on ion-pair chromatography, reversed phase (RP) column material and specific fluorimetric detection at 300 nm and 355 nm. Sample preparation and gradient elution were avoided by using a column-switching technique. The sensitivity of the assay was excellent for clinical routine analysis, with a detection limit of 0.2 mg/L 5-HIAA. No endogenous or exogenous interference problems arose. Intra- and interassay precision was good, with observed coefficients of variation of 1.5 to 2.6% and 2.1%, respectively. Recoveries were 93 to 98%. The system described can be used for clinical diagnosis and therapy follow-up of carcinoid tumors. It has been running for over a year without disturbances and with a minimum of technical attendance.  相似文献   

4.
A bioanalytical method is described that allows the determination of a number of beta-endorphin-related peptides. The method is based on the application of fluorescence detection after high-performance liquid chromatography followed by post-column derivatization with o-phthaldialdehyde. Concentrations exceeding 10-25 ng/ml could be determined by using conventional fluorescence detection, whereas lower concentrations demand the use of laser-induced fluorescence detection. The sample pretreatment includes the use of on-line gel permeation, on-line solid-phase isolation and heart cutting of a peak from reversed-phase gradient elution. The sample pretreatment procedure does not discriminate between the dodecapeptide des-enkaphalin-gamma-endorphin (DE gamma E) and its metabolites in order to obtain similar recoveries for all components. The final chromatographic phase system is based on ion-pair formation, which permits the separation of DE gamma E from its metabolites and degradation products. The optimized procedure allows the determination of these peptides in plasma at concentration levels down to about 1 ng/ml, demanding a sample volume of 1 ml.  相似文献   

5.
Reversed-phase high-performance liquid chromatography (RP-HPLC) with UV detection at 210 nm was used to monitor the formation of the major compounds during the lipase-catalyzed transesterification reaction of sunflower oil with methanol. Individual triacylglycerols, diacylglycerols, monoacylglycerols as well as fatty acids and their corresponding methyl esters were separated using acetonitrile/acetone as a mobile phase and a combined linear gradient-isocratic-step gradient-isocratic elution procedure. Another relatively short method consisting of a linear gradient elution followed by an isocratic elution gave similar results, yet with lower resolution. HPLC/mass spectrometry with an ion trap analyzer and atmospheric pressure chemical ionization source was used for the identification of the individual compounds. Individual calibration curves obtained with UV detection at 210 nm were found to be of use for quantitative analyses of double-bond containing methyl esters and acylglycerols. The use of the RP-HPLC methods in the elucidation of the mechanisms of three immobilized lipases, namely Lipozyme TL IM, Lipozyme RM IM and Novozym 435, in biodiesel production was described.  相似文献   

6.
In this study, the advantages of carrying out the analysis of peptides and tryptic digests of proteins under gradient elution conditions at pH 6.5 by reversed-phase liquid chromatography (RP-HPLC) and in-line electrospray ionisation mass spectrometry (ESI-MS) are documented. For these RP separations, a double endcapped, bidentate anchored n-octadecyl wide pore silica adsorbent was employed in a capillary column format. Compared to the corresponding analysis of the same peptides and protein tryptic digests using low pH elution conditions for their RP-HPLC separation, this alternative approach provides improved selectivity and more efficient separation of these analytes, thus allowing a more sensitive identification of proteins at different abundance levels, i.e. more tryptic peptides from the same protein could be confidently identified, enabling higher sequence coverage of the protein to be obtained. This approach was further evaluated with very complex tryptic digests derived from a human plasma protein sample using an online two-dimensional (2D) strong cation-exchange (SCX)-RP-HPLC-ESI-MS/MS system. Again, at pH 6.5, with mobile phases of different compositions, improved chromatographic selectivities were obtained, concomitant with more sensitive on-line electrospray ionisation tandem mass spectrometric (ESI-MS/MS) analysis. As a consequence, more plasma proteins could be confidently identified, highlighting the potential of these RP-HPLC methods with elution at pH 6.5 to extend further the scope of proteomic investigations.  相似文献   

7.
Xi H  Han G  Lü L  Zhang D 《色谱》2011,29(10):1000-1004
建立了离子对反相高效液相色谱法(IP-RP-HPLC)同时测定家兔血浆中外源性磷酸肌酸(PCr)及其代谢产物肌酸(Cr)的方法,用于研究外源性PCr在家兔体内的药代动力学。以含离子对试剂四丁基硫酸氢铵(TBA)的磷酸盐缓冲液-甲醇为流动相,在Kromasil-C18色谱柱上进行梯度洗脱。采用内标法定量、以基线扣除法计算外源性PCr和Cr的浓度。PCr和Cr的线性范围分别为10~7500 mg/L和10~1500 mg/L;日内和日间精密度均≤6.2%,准确度分别为99.7%~102.2%和96.5%~102.4%;萃取回收率均大于92%。静脉注射PCr后,血浆中PCr的消除为二室模型,消除半衰期为(20.4±2.7) min;表观分布容积为(0.179±0.037) L/kg;清除率为(0.019±0.002) L/(kg\5min);静脉注射PCr后血浆中迅即出现降解产物Cr,其达峰时间为30 min;消除半衰期为(43.7±4.5) min。本方法的专属性强,准确度和精密度高,能特异性地测定家兔血浆中的PCr和Cr。实际应用结果表明,该方法完全符合PCr药代动力学生物分析方法学的要求。  相似文献   

8.
To develop a fluorimetric HPLC technique for the simultaneous microanalysis of reducing mono- and oligosaccharides, the technique of linear gradient elution was introduced into the postcolumn fluorimetric detemination system of reducing saccharides with benzamidine. Fluorescence measurement was performed at 288 nm for excitation and 470 nm for emission and an optimization study for this postcolumn fluorescence derivatization carried out. Under optimum conditions, the detection limits of D-glucose and maltohexaose were 1.78 and 2.59 pmol, respectively. The present method was successfully applied to saccharide analysis and should prove useful for automated simultaneous microanalysis of reducing mono- and oligosaccharides in foods.  相似文献   

9.
Abstract— The oxidation products of ascorbic acid react with lens proteins to form advanced glycation endproducts (AGE) that are capable of generating reactive oxygen species when irradiated with UVA light. L-Threose, the most active of these oxidation products, was reacted with N -acetyl lysine and six AGE peaks were isolated by RP-HPLC. Each peak exhibited fluorescence and generated superoxide anion and singlet oxygen in response to UV light. Solutions of these AGE peaks (50 μg/mL) generated5–10 nmol/mL of superoxide anion during a 30 min irradiation. This activity was 100-fold less than the superoxide anion generated by kynurenic acid and 400-fold less than riboflavin.
Ultraviolet irradiation generated from 1.2 to 2.7 μmol/mL of singlet oxygen with the purified threose AGE compounds. This activity was similar to that seen with other purified AGE compounds (pentosidine, LM-1 and Ac-FTP) and with kynurenine and 3-OH kynurenine. This considerable singlet oxygen formation, however, was still 40-fold less than that obtained with kynurenic acid and 100-fold less than riboflavin under the same irradiation conditions. In spite of this lower sensitizer efficiency, the purified AGE generated20–60-fold more singlet oxygen on a weight basis than either crude ascorbic acid glycated proteins or a preparation of water-insoluble proteins from aged normal human lenses. On a molar basis, therefore, AGE could account for the sensitizer activity in these protein preparations if they represented less than 1% of the total amino acids.  相似文献   

10.
建立了鳗鲡体中丙硫咪唑及其代谢物残留量测定方法。样品用乙腈提取,经正己烷净化后,液相色谱一荧光法测定,标准加入法定量。流动相为:甲醇、乙腈和乙酸铵,梯度洗脱。检测波长为:激发波长290nm,发射波长320nm,丙硫咪唑、2氨基丙硫咪唑砜、丙硫咪唑亚砜、丙硫咪唑砜检出限依次为:25、5、10、1μg/kg。回收率大于95%,相对标准偏差小于8%。  相似文献   

11.
A fluorimetric method is proposed for determining N-terminal tyrosine-containing peptides, of which some peptides such as enkephalins and kyotorphin are of physiological importance. An intense fluorescence is produced when the peptide is heated at 100°C for 3 min in a weakly alkaline medium containing borate, hydroxylamine and cobalt(II). The fluorescent species is stabilized with β-mercaptoethanol, with excitation and emission maxima at 335 and 430 nm, respectively. The method is highly selective for N-terminal tyrosine-containing peptides, with a detection limit of 43–69 pmol ml?1.  相似文献   

12.
We have previously reported the development of a far-ultraviolet (FUV) absorbance detector capable of detecting wavelengths down to 175 nm in high-performance liquid chromatography (HPLC). Although the FUV detector can detect substances with weak to non-existent ultraviolet (UV) absorption (e.g., sugars at 185 nm and peptides at 190 nm), a large baseline drift occurs in the gradient elution due to differences in the FUV absorbance properties of water and acetonitrile. To overcome the problem of baseline drift, we have proposed a new baseline correction method using the absorption of water at 1450 nm. It is well known that water has a relatively large absorption peak at 1450 nm in the near-infrared (NIR) region. By contrast, acetonitrile used in reversed-phase HPLC shows negligible absorbance compared to water at 1450 nm. Sugars and peptides also show negligible absorbance at 1450 nm. Thus, it is expected that changes in absorbance at 1450 nm only reflect the volume fraction of water in the gradient elution. The baseline correction method by a linear combination of FUV and NIR chromatograms was applied to the HPLC separation of sugars and peptides in water/acetonitrile-gradient HPLC coupled with FUV detection. The results showed that flat baselines were successfully obtained in the gradient HPLC coupled with FUV detection.  相似文献   

13.
The retention behaviour and selectivity of selected basic, neutral and acidic peptides have been studied by capillary electroendoosmotic chromatography (CEC) with Hypersil C8, C18, Hypersil mixed-mode, and Spherisorb C18/SCX columns, 250 (335) mm x 100 microns, packed with 3 microns particles, and eluted with mobile phases composed of acetonitrile-triethylamine-phosphoric acid (TEAP) at pH 3.0 using a Hewlett-Packard Model HP3DCE capillary electrophoresis system. The selected peptides were desmopressin (D), two analogues (A and B) of desmopressin, oxytocin (O) and carbetocin (C). The peptides eluted either before or after the electroendoosmotic flow (EOF) marker, depending on the concentration of acetonitrile used and the buffer ionic strength. The retention and selectivity of these peptides under CEC conditions were compared to their behaviour in free zone capillary electrophoresis (CZE), where the separation mode was based on the electrophoretic migration of the analytes due to their charge and Stokes radius properties. In addition, their retention behaviour in RP-HPLC was also examined. As a result, it can be concluded that the elution process of this group of synthetic peptides in CEC with a TEAP buffer at pH 3.0 is mediated by a combination of both electrophoretic migration processes and retention mechanisms involving hydrophobic as well as silanophilic interactions. This CEC method when operated with these 3 microns reversed-phase and mixed-mode sorbents with peptides is thus a hybrid of two well-known analytical methods, namely CZE and RP-HPLC. However, the retention behaviour and selectivity of the selected peptides differs significantly in the CEC mode compared to the RP-HPLC or CZE modes. Therefore this CEC method with these peptides represents an orthogonal analytical separation procedure that is complimentary to both of these alternative techniques.  相似文献   

14.
A new analytical methodology for the determination of fully methoxylated flavones (FMFs) in citrus juices is described. Isolation of the FMFs is carried out by percolation of 30 mL of clarified citrus juice (to which tetramethyl-o-kaempferol is previously added as internal standard) through a C18 Sep-Pak cartridge, washing with 3 mL of water followed by 5 mL of water/acetonitrile (3:1), and selective elution of the retained FMFs with 5 mL of water/acetonitrile (9:11). Determination of the isolated FMFs is carried out by reversed-phase high-performance liquid chromatography (HPLC) and UV diode array detection (DAD). Signals at wavelengths 320, 335, and 345 nm (bandwidth 4 nm) are simultaneously acquired, stored, plotted, and integrated. The column used is a microbore (200 x 2.1-mm) Hypersil ODS 5 microns. Elution is in gradient mode, using a ternary mobile phase (water/acetonitrile/tetrahydrofuran). Column temperature is 40 degrees C. Recovery yields are nearly 100% for all the FMFs detected and identified: isosinensetin, hexamethyl-o-gossypetin, sinensetin, tetramethyl-o-isoscutellarein, hexamethyl-o-quercetagetin, nobiletin, tetramethyl-o-scutellarein, heptamethoxyflavone, and tangeretin. Chromatographic separation of the FMFs is extremely dependent upon the minor changes of the mobile phase composition and percentages, gradient rate, and temperature. The UV spectra (230 to 400 nm) of the FMFs obtained under chromatographic conditions are given. The FMFs relative response factors at 320, 335, and 345 nm and their concentrations in hand-squeezed and commercial concentrated orange and mandarin juices are tabulated. The FMF concentration differences found among samples are discussed.  相似文献   

15.
反相高效液相色谱法分离重组促红细胞生成素   总被引:4,自引:1,他引:3  
邹钟诚  孙开来  娄丹  胡明 《色谱》1998,16(3):263-264
利用反相高效液相色谱法对重组促红细胞生成素进行了纯化。结果表明,利用C4反相柱和乙腈-三氟乙酸流动相在洗脱梯度和上样样品纯度等条件都较适当时,可以简单、快速、高效地从粗品中分离出重组促红细胞生成素,获得的产品纯度高,接近100%;比活性好,约为1.96×108IU/g蛋白。  相似文献   

16.
A method using reversed-phase ion-pair liquid chromatography with dual detection was developed for the simultaneous determination of the S-adenosylmethionine (SAM) analogues and the natural polyamines. The separation is obtained with a gradient elution and by adjusting the concentration of octanesulfonic acid used as ion-pairing agent, the ionic strength of the eluent, the pH and the acetonitrile content of the eluents. The SAM analogues are analyzed by UV detection at 254 nm and the polyamines by fluorescence detection after post-column derivatization with o-phthalaldehyde. The method allows the determination of the SAM analogues and the polyamines in one single run by direct injection of tissue extracts. The procedure is applied to the study in rats and in hepatoma tissue culture cells of the biochemical effects of alpha difluoromethylornithine, a potent enzyme-activated irreversible inhibitor of ornithine decarboxylase.  相似文献   

17.
Murine epidermal growth factor (m-EGF), a polypeptide produced as a chromatographically homogeneous peak on diethylaminoethyl (DEAE) cellulose by the method of Savage and co-workers, and characterised as a single compound, has been shown by ourselves and several other groups to be a mixture. The present contribution extends our previously reported work and discusses the separation of this material, termed DEAE-m-EGF, into its components by preparative ion-pair reversed-phase high-performance liquid chromatography (RP-HPLC) on C18 mu Bondapak in quantities up to 50 mg per run. Isocratic elution was used and the mobile phase was acetonitrile-water (26:74, v/v, 0.04 M in triethylamine acetate); pH was 5.6, temperature 40 degrees C, and detection was by ultraviolet absorption at 254 nm, and (for some runs) by differential refractometry. Seven significant peaks, four major, three minor, were detected. Of the major peaks, two designated alpha- and beta-EGF, constituted 70% of the total mass and were the most important to our work. Each of the eluted peaks was recovered by lyophilisation, and this product checked for homogeneity by ion-pair RP-HPLC on a C18 mu Bondapak analytical column, with ultraviolet detection as before. All recovered peaks were found to be homogeneous by this criterion. These chromatographically homogeneous compounds were investigated by modern physicochemical instrumentation to determine their structure. The molecular weight of each of the species was determined by fast atom bombardment mass spectrometry. High-field proton magnetic resonance at 270 MHz provided structural and conformational information. Polarimetry and ultraviolet absorption were also used to characterise the compound. alpha-EGF, for example, had a molecular weight of 6040 corresponding to the 53 amino acid residue peptide previously designated EGF; beta-EGF had a molecular weight of 5930. This molecular weight differential of 110 suggested the hypothesis that beta-EGF was a 52 residue peptide corresponding to alpha-EGF minus the terminal asparagine at position 1. Proton magnetic resonance difference spectroscopy (beta spectrum subtracted from alpha) provided powerful confirmatory evidence for this hypothesis. All materials recovered from RP-HPLC were tested in the sheep and found to retain their biological activity.  相似文献   

18.
A procedure was proposed for the determination of free bile acids and their conjugates in blood plasma by the reversed-phase HPLC using the column Lichrospher 100 RP-18 (250 + 4.6 mm) with gradient elution and UV-detection at 206 nm. The procedure allowed the simultaneous determination of diagnostically important cholic acids, tauro-and glyco-cholates in blood plasma of patients with no preliminary separation of the analytes into subtypes. The bile acids and their conjugates were isolated from the sample matrix by solid phase extraction in a Sep-Pack C18 cartridge. The limits of detection were 0.11–0.15 mM for free acids and 0.015–0.025 mM for conjugates.  相似文献   

19.
酪蛋白多肽的制备和色谱分离方法   总被引:1,自引:0,他引:1  
Cai H  Yin B  Yao P 《色谱》2010,28(7):637-643
为了得到低成本的多肽,本文利用胰蛋白酶对酪蛋白进行了充分的酶解。采用分析级反相高效液相色谱-电喷雾质谱联用技术(RP-HPLC/ESI-MS)分析了酶解产物各组分的组成,并通过改变流动相的梯度洗脱程序,优化了分析级色谱条件以充分分离相对含量较高的多肽组分;将优化的分析级色谱条件直接放大到制备级RP-HPLC中,在程序控制下通过紫外吸收信号结合ESI-MS信号共同引导实现了多肽的全自动化分离和收集。整个过程方便快捷,经过这样一个单一的分离步骤,得到了多个纯度较高的多肽。除此之外,本文还考察了流动相的酸碱性、柱上样量等因素对该体系制备级分离的影响,并对一次分离中分辨率不好的亲水性多肽混合物进行了二次分离,得到了多个新的多肽。本文建立的多肽制备方法为多肽和多肽材料的广泛应用提供了一种选择。  相似文献   

20.
A fully automated analyzer for methylated L-arginine metabolites [N,N-dimethyl-L-arginine (ADMA), N-methylarginine (NMMA) and N,N'-dimethyl-L-arginine (SDMA)] by high-performance liquid chromatography with post-column fluorescence derivatization was developed. This system consists of an on-line extraction, a separation on a reversed phase ion-pair chromatograph, a post-column derivatization by o-phthaladehyde (OPA) and thiol reaction, and fluorescence detection. NMMA, ADMA and SDMA were separated in 40 min with isocratic elution by a combination of octanoate and cyclohexane carboxylate as ion-pair reagents. The eluate was monitored at 450 nm with excitation at 337 nm. The calibration curves for NMMA, ADMA and SDMA showed linearity over the range from 0.05 micromol l(-1) (0.5 pmol on column) to 5.0 micromol l(-1) (50 pmol on column). This method does not require any time-consuming pre-treatment and requires only 10 microl of plasma sample for assay.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号