In situ photopolymerized polyacrylamide (PAAm) gel plugs are used as hydrodynamic flow control elements in a multidimensional microfluidic system combining IEF and parallel SDS gel electrophoresis for protein separations. The PAAm gel plugs offer a simple method to reduce undesirable bulk flow and limit reagent/sample crosstalk without placing unwanted constraints on the selection of separation media, and without hindering electrokinetic ion migration in the complex microchannel network. In addition to improving separation reproducibility, the discrete gel plugs integrated into critical regions of the chip enable the use of a simple pressure-driven sample injection method which avoids electrokinetic injection bias. The gel plugs also serve to greatly simplify operation of the spatially multiplexed system by eliminating the need for complex external fluidic interfaces. Using an FITC-labeled Escherichia coli cell lysate as a model system, the use of gel plugs is shown to significantly enhance separation reproducibility in a chip containing five parallel CGE channels, with an average variance in peak elution time of only 4.1%. 相似文献
Two-dimensional gel isoelectric focusing (2-D gel IEF) is presented as the combination of the same separation method used consecutively in two directions of the same gel. In this new method, after completion of IEF process in the first dimension the gel was cut into the separate strips, each containing selected analytes together with the appropriate part of the original broad pH gradient, and the strips were rotated by 90 degrees (with regard to the first IEF) and left to diffuse overnight. After diffusion the strips were subjected to the second IEF. During the second IEF, the corresponding narrow part of pH gradient in each strip was restored again, however, now along the strip. The progress of the separation process can be monitored visually by using colored low-molecular-weight isoelectric point (pI) markers loaded into the gel simultaneously with proteins. The unique properties of IEF, focusing and resolution power were enhanced by using the same technique twice. Two forms of beta-lactoglobulin (pI values 5.14 and 5.31, respectively) non-separated in the first IEF were successfully separated in the second dimension at relatively low voltage (330 V) with the resolution power comparable to the high-resolution gels requiring the high voltage during the run and long separation time. Glucose oxidase loaded as diluted solution into ten positions across the gel was finally focused into a single band during 2-D gel IEF. Since the first and second IEF are carried out on the same gel, no losses and contamination of analyte occur. The suggested method can be used for separation/fractionation of complex biological mixtures, similarly as other multidimensional separation techniques applied in proteomics, and can be followed by further processing, e.g., mass spectrometry analysis. The focusing properties of IEF could be useful especially in separation of mixtures, where components are at low concentration levels. 相似文献
In this work a 2D electrophoretic separation procedure able to maintain the integrity of platinum-protein bonds has been developed. The method is based on the use of sequential OFFGEL isoelectric focussing (IEF) and PAGE. A systematic study of the reagents used for PAGE, for OFFGEL-IEF separation, and post-separation treatment of gels (such as enzymatic digestion and sample preparation for MS analysis) was tackled regarding their suitability for the identification of platinum binding proteins using standard proteins incubated with cisplatin. The distribution of platinum in high and low molecular weight fractions (separated by cut-off filters) was determined by ICP-MS, which allows evaluating platinum-protein bond stability under the conditions studied. SDS-PAGE in the absence of β-mercaptoethanol or dithiotreitol preserved the platinum-protein bonds. In addition, neither the influence of the electric field during the electrophoretic separation, nor the processes of fixing, staining and destaining of proteins in the gel did result in the loss of platinum from platinum binding proteins. SDS-PAGE under non-reducing conditions provides separation of platinum-binding proteins in very narrow bands with quantitative recoveries. Different amounts of platinum-bound proteins covering the range 0.3-2.0 μg were separated and mineralised for platinum determination, showing good platinum linearity. Limits of detection for a mixture of five standard proteins incubated with cisplatin were between the range of 2.4 and 13.9 pg of platinum, which were satisfactory for their application to biological samples. Regarding OFFGEL-IEF, a denaturing solution without thiourea and without dithiotreitol is recommended. The suitability of the OFFGEL-IEF for the separation of platinum binding proteins of a kidney cytosol was demonstrated. 相似文献
Using a microfabricated chip with a bed volume of 0.2 microL we demonstrate the validity of the scaling laws for molecular mass transport of isoelectric focusing (IEF) in free flow. Nano- or microlitre sample volumes can be concentrated within 430 ms by a factor of up to 400. These very fast performances make the chip applicable to proteomic analysis and for continuous monitoring of biochemical processes. 相似文献
A new isoelectric focusing (IEF) system for two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) has been proposed. In this system, a super-soft and tough IEF gel was achieved by casting polyacrylamide gel down to 2.0% T using a loose multifilament string (LMS) of nylon as a gel support. The IEF apparatus for the LMS-gel, fabricated from acrylic boards, had a cooling water chamber, and eliminated the need of electrode solutions by directly connecting the two ends of individual gels to platinum electrodes. The carrier ampholyte-generated pH gradients using the new IEF system was stable over a long duration of time and a wide range of voltages, and the IEF time became shorter using a 2.0% T gel than using a 4.0% T gel. Also, the LMS-gels prepared in different runs exhibited excellent reproducibility. The new IEF system was applied to 2-D PAGE of a chicken skeletal muscle extract, and it was found that the protein loading capacity, protein entry into the LMS-gels, and protein transfer efficiency from the first-dimensional to the second-dimensional gels were significantly improved by using a low-concentration (2.5% T) gel. Also, proteins of high molecular weight of more than 200 kDa were observed in the 2-D maps, and therefore the new IEF system has a very good potential to be applied for fast 2-D PAGE of high molecular-weight proteins. 相似文献
The suitability of four different fabric materials for the preparation of ultrathin rein-forced polyacrylamide gels was investigated. With all fabric-reinforced gels, a good separation of proteins by isoelectric focusing and sodium dodecyl sulfate-electrophoresis could be achieved. Semi-dry electrophoretic blotting of proteins was possible with all types of fabric-reinforced gels. Two polyester fabrics (a net and a fleece) were decidedly superior in handling and dimensional stability on drying to a nylon fabric and another polyester fleece material. Only gels prepared with the former materials withstood further treatment, such as fixation, staining, destaining, and drying. One of the polyester fleece fabrics had poor handling properties and the nylon fabric was unsuitable for direct staining procedures employing concentrated (20% w/v) trichloroacetic acid as fixative. 相似文献
A method is introduced for open-column photo-induced site-selective immobilization of pH gradients in a layer of PEG-methacrylate in a multi-dimensional microfluidic chip for use in electrophoresis. It has several attractive features: (a) mixtures of fluorescently labelled proteins carbonic anhydrase, catalase and myoglobin in their native state can be separated by pH-gradient isoelectric focusing (IEF) and zone electrophoresis (CZE) using integrated 2D chip electrophoresis; (b) compared to strip packing or monolithic photo-immobilization, it overcomes the shortcomings of free carrier ampholyte-based 2D chip electrophoresis in an easy way; (c) larger amount of sample can be loaded into the open column-mode electrophoresis (d) immobilized pH gradients can be re-used and the chip can be recycled; (e) a multilayer 3D pH gradient is established by a layer-by-layer assembly technique to further increase the separation capacity. In our perception, this strategy has a large potential in microfluidic chip-based separation schemes because of its simplicity, separation power, re-usability, and separation capacity.
We report the demonstration of miniaturized capillary isoelectric focusing (CIEF) in plastic microfluidic devices. Conventional CIEF technique was adapted to the microfluidic devices to separate proteins and to detect protein-protein interactions. Both acidic and basic proteins with isoelectric points (pI) ranging from 5.4 to 11.0 were rapidly focused, mobilized, and detected in a 1.2 cm long channel (50 microm deep x 120 microm wide) with a total analysis time of 150 s. In a device with a focusing distance of 4.7 cm, the separation efficiency for a basic protein, lysozyme, was achieved as high as 1.5 x 10(5) plates, corresponding to 3.2 million plates per meter. We also experimentally confirmed that IEF resolution is essentially independent of focusing length when the applied voltage is kept the same and within a range that it does not cause Joule heating. Further, we demonstrated the use of miniaturized CIEF to study the interactions between two pairs of proteins, immunoglobulin G (IgG) with protein G and anti-six histidine (anti-6xHis) with 6xHis-tagged green fluorescent protein (GFP). Using this approach, protein-protein interactions can be detected for as little as 50 fmol of protein. We believe miniaturized CIEF is useful for studying protein-protein interactions when there is a difference in pI between a protein-protein complex and its constitutent proteins. 相似文献
Rhoptry neck protein 2 (RON2) binds to the hydrophobic groove of apical membrane antigen 1 (AMA1), an interaction essential for invasion of red blood cells (RBCs) by Plasmodium falciparum (Pf) parasites. Vaccination with AMA1 alone has been shown to be immunogenic, but unprotective even against homologous challenge in human trials. However, the AMA1-RON2L (L is referred to as the loop region of RON2 peptide) complex is a promising candidate, as preclinical studies with Freund's adjuvant have indicated complete protection against lethal challenge in mice and superior protection against virulent infection in Aotus monkeys. To prepare for clinical trials of the AMA1-RON2L complex, identity and integrity of the candidate vaccine must be assessed, and characterization methods must be carefully designed to not dissociate the delicate complex during evaluation. In this study, we developed a native Tris-glycine gel method to separate and identify the AMA1-RON2L complex, which was further identified and confirmed by Western blotting using anti-AMA1 monoclonal antibodies (mAbs 4G2 and 2C2) and anti-RON2L polyclonal Ab coupled with mass spectrometry. The formation of complex was also confirmed by Capillary Isoelectric Focusing (cIEF). A short-term (48 h and 72 h at 4°C) stability study of AMA1-RON2L complex was also performed. The results indicate that the complex was stable for 72 h at 4°C. Our research demonstrates that the native Tris-glycine gel separation/Western blotting coupled with mass spectrometry and cIEF can fully characterize the identity and integrity of the AMA1–RON2L complex and provide useful quality control data for the subsequent clinical trials. 相似文献
The influence of several operation conditions on separation of recombinant human erythropoietin glycoforms by capillary isoelectric focusing (cIEF) is explored. From this study it is deduced that in order to separate several glycoforms of erythropoietin, urea has to be added to sample, which should not be completely depleted of the excipients used in its formulation. On-line desalting does not provide separation enhancement for samples with high content of salt. Better resolution is obtained using a mixture of a broad and a narrow pH-range carrier ampholytes than with either one used separately. Under the experimental conditions, focusing voltages of 25 kV improve separation compared to lower and higher electric fields. Focusing times shorter than the time necessary for electric current to reach a minimum provide similar separations than longer focusing times at which a minimum value of the current has already been achieved. The optimized method allows the separation and quantitation in 12 min of at least seven bands containing glycoforms of recombinant erythropoietin with apparent isoelectric points in the range 3.78–4.69. Compared to flat-bed isoelectric focusing, cIEF provides better separation of bands of glycoforms in a shorter time, and allows quantitative determination. Capillary zone electrophoresis (CZE) gives rise to resolution of erythropoietin glycoforms similar to that obtained by cIEF. Although CZE requires a longer analysis time, its reproducibility in terms of peak area of glycoforms is better than in cIEF. 相似文献
Immobilized pH gradients use a series of weak acrylamido acids and bases (Immobiline) to create a pH gradient along the separation axis. These buffers can be degraded in water by two mechanisms: (i) hydrolysis of the amido bond, with generation of free acrylic acid and either an amino acid or a diamine; (ii) autopolymerization to oligomers and/or n-mers. In order to check for these degradation products, different capillary zone electrophoresis systems for analysis of all Immobilines have been devised. The acidic compounds are resolved in 100 mM acetate, pH 4.0, whereas the alkaline Immobilines are separated in 50 mM phosphate buffer, pH 7.7 (or pH 7.2 for the weaker species). Polymers of alkaline Immobilines are resolved in 50 mM phosphate buffer, pH 2.5, in 1% Ficoll-400. All Immobilines are detected underivatized, by their adsorption at 214 or 254 nm. A calibration curve has been constructed for quantification of acrylic acid contamination. As little as 1 mol% of acrylic acid contamination in Immobiline solutions can be detected, with a sensitivity limit below 0.2 mM (at the injection port). 相似文献
Despite its excellent resolving power, 2-DE is of limited use when analyzing cellular proteomes, especially in differential expression studies. Frequently, fewer than 2000 protein spots are detected on a single 2-D gel (a fraction of the total proteome) regardless of the gel platform, sample, or detection method used. This is due to the vast number of proteins expressed and their equally vast dynamic range. To exploit 2-DE unique ability as both an analytical and a preparative tool, the significant sample prefractionation is necessary. We have used solution isoelectric focusing (sIEF) via the ZOOM IEF Fractionator (Invitrogen) to generate sample fractions from complex bacterial lysates, followed by parallel 2-DE, using narrow-range IPG strips that bracket the sIEF fractions. The net result of this process is a significant enrichment of the bacterial proteome resolved on multiple 2-D gels. After prefractionation, we detected 5525 spots, an approximate 3.5-fold increase over the 1577 spots detected in an unfractionated gel. We concluded that sIEF is an effective means of prefractionation to increase depth of field and improve the analysis of low-abundance proteins. 相似文献
A number of environmental factors were used experimentally to enhance myogenesis during muscle regeneration; however, many hormones and growth factors have been shown to have the ability to increase the rate of satellite cell division, but they only work on satellite cells that are already active in many animal experiments. Recently, the crushed muscle extract (CME) of rats was found to be able to trigger dormant adult rat satellite cells to re-enter the cell mytogenic cycle; however, the identity of the active factors present in rat CME remains unknown. In the present study, the CME was fractionated by the strategy of sequential isoelectric focusing and sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) coupled with functional analysis by myoblast culture. Two satellite cell-specific myogenic factors were identified and purified from CME by this strategy. One of the factors has a molecular mass of around 7 kDa and another about 39 kDa. The factor of 39 kDa could be retained in heparin-Sepharose column and eluted with phosphate-buffered saline (PBS) containing 1 M NaCl, but the 7 kDa factor did not bind to the heparin column. These two purified myogenic factors could synergistically trigger the proliferation and differentiation of dormant satellite cells, whose progenies subsequently fuse in vitro, or fuse to pre-existing partially damaged muscle fibers to form full repair of the damaged muscle fibers or to form new myotubes to replace the completely damaged muscle fibers during the cascade of muscle healing and regeneration in vivo. The identities of these two myogenic factors are under study. 相似文献
Isoelectric focusing in a polyacrylamide pH gradient gel is used to analyze the size distribution of gold nanoparticles synthesized by a chemical route with mercaptosuccinic acid as a ligand. The isoelectric point of the nanoparticles is shown to be size dependent, allowing fractionation by electrophoresis. Each fraction has a narrow size distribution with a standard deviation lower than 0.4 nm. 相似文献
The dynamics of gel isoelectric focusing were studied by using amphoteric low-molecular-mass colored substances (isoelectric point markers). The polyacrylamide gel in slab format was in direct contact with the electrodes. In addition to isoelectric focusing with a pH gradient composed of synthetic carrier ampholytes, pH gradients created by simple buffers of acetic acid, 2-(N-morpholino)ethanesulfonic acid, histidine and N,N,N',N'-tetramethylethylenediamine were applied. The progress of the electrofocusing process was monitored by a charge-coupled device camera and video recording. The gradient profile and dynamics were approximated from the positions of isoelectric point markers, which were focused both on boundaries between individual zones of simple buffers and within the zones themselves. The obtained animated records enabled the observation of the entire real focusing run within fractions of a minute, which is useful both for the understanding and optimization of the focusing. 相似文献
Three common phenotypes of 6-phosphogluconate dehydrogenase (6-PGD) were identified by enzyme visualization following isoelectric focusing in photochemically polymerized polyacrylamide gels whereas in chemically polymerized gels no activity could be detected. Gene frequencies calculated from 429 individuals were 0.915 and 0.085 for 6-PGD*A and 6-PGD*C, respectively, similar to the gene frequencies of Japanese samples previously reported. 相似文献
In order to assess secretory pancreatic proteins in a two-dimensional isoelectric focusing/sodium dodecyl sulphate electrophoresis gel, a highly sensitive double-staining method with Coomassie Brilliant Blue followed by silver stain was used. This combined procedure afforded more distinct spots and additional bands, particularly glycoproteins, than either silver or Coomassie Blue staining alone. As measurements of dye volumes by densitometry have shown, double staining of two-dimensional separated pancreatic proteins is up to twenty times more sensitive than the usual Coomassie Brilliant Blue staining. 相似文献
A rapid and simple method has been developed for precisely locating and cutting 1-3 mm strips from the isoelectric focusing gel during two-dimensional electrophoresis using the PhastSystem. The protocol utilizes an easily constructed styrofoam template with marks to guide accurate cutting of the strips from the sample lanes. This system greatly enhances the reproducibility and quality of the two-dimensional patterns obtained. 相似文献
This paper describes a microfabricated free-flow electrophoresis device with integrated ion permeable membranes. In order to obtain continuous lanes of separated components an electrical field is applied perpendicular to the sample flow direction. This sample stream is sandwiched between two sheath flow streams, by hydrodynamic focusing. The separation chamber has two open side beds with inserted electrodes to allow ventilation of gas generated during electrolysis. To hydrodynamically isolate the separation compartment from the side electrodes, a photo-polymerizable monomer solution is exposed to UV light through a slit mask for in situ membrane formation. These so-called salt-bridges resist the pressure driven fluid, but allow ion transport to enable electrical connection. In earlier devices the same was achieved by using open side channel arrays. However, only a small fraction of the applied voltage was effectively utilized across the separation chamber during free-flow electrophoresis and free-flow isoelectric focusing. Furthermore, the spreading of the carrier ampholytes into the side channels resulted in a very restricted pH gradient inside the separation chamber. The chip presented here allows at least 10 times more efficient use of the applied potential and a nearly linear pH gradient from pH 3 to 10 during free-flow isoelectric focusing could be established. Furthermore, the application of hydrodynamic focusing in combination with free-flow electrophoresis can be used for guiding the separated components to specific chip outlets. As a demonstration, several standard fluorescent markers were separated and focused by free-flow zone electrophoresis and by free-flow isoelectric focusing employing a transversal voltage of up to 150 V across the separation chamber. 相似文献