首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Growing interest in magnetic resonance imaging (MRI) at ultra-low magnetic fields (ULF, approximately muT fields) has been motivated by several advantages over its counterparts at higher magnetic fields. These include narrow line widths, the possibility of novel imaging schemes, reduced imaging artifacts from susceptibility variations within a sample, and reduced system cost and complexity. In addition, ULF NMR/MRI with superconducting quantum interference devices is compatible with simultaneous measurements of biomagnetic signals, a capability conventional systems cannot offer. Acquisition of MRI at ULF must, however, account for concomitant gradients that would otherwise result in severe image distortions. In this paper, we introduce the general theoretical framework that describes concomitant gradients, explain why such gradients are more problematic at low field, and present possible approaches to correct for these unavoidable gradients in the context of a non-slice-selective MRI protocol.  相似文献   

2.
采用一高温超导射频量子干涉器(HTS rf-SQUID)作为信号探测器件,研究了多种液体样品的低场核磁共振信号。通过改变测量场(简称Bm)的大小,可以探测到质子拉莫频率(简称fL)从2Hz到40kHz的信号。由于在低场核磁共振中,Bm的均匀性能很好的得到满足,因而可能得到很窄的谱线宽度。实验发现,对自来水样品,在7μT以下均可接近谱线的自然宽度。同时,在低场核磁共振条件下,样品的化学位移很小以至于消失,因而可以研究"纯"的异核间的自旋耦合谱。作者研究了低场下2,2,2-三氟乙醇的低场自旋耦合谱。另外,作者首次采用SQUID在户外探测到地球磁场下的核磁共振现象,并研究了地球磁场的涨落对测量的影响,为SQUID的低场核磁共振研究开辟了一个新的研究方向。  相似文献   

3.
Parallel MRI at microtesla fields   总被引:2,自引:2,他引:0  
Parallel imaging techniques have been widely used in high-field magnetic resonance imaging (MRI). Multiple receiver coils have been shown to improve image quality and allow accelerated image acquisition. Magnetic resonance imaging at ultra-low fields (ULF MRI) is a new imaging approach that uses SQUID (superconducting quantum interference device) sensors to measure the spatially encoded precession of pre-polarized nuclear spin populations at microtesla-range measurement fields. In this work, parallel imaging at microtesla fields is systematically studied for the first time. A seven-channel SQUID system, designed for both ULF MRI and magnetoencephalography (MEG), is used to acquire 3D images of a human hand, as well as 2D images of a large water phantom. The imaging is performed at 46 mu T measurement field with pre-polarization at 40 mT. It is shown how the use of seven channels increases imaging field of view and improves signal-to-noise ratio for the hand images. A simple procedure for approximate correction of concomitant gradient artifacts is described. Noise propagation is analyzed experimentally, and the main source of correlated noise is identified. Accelerated imaging based on one-dimensional undersampling and 1D SENSE (sensitivity encoding) image reconstruction is studied in the case of the 2D phantom. Actual threefold imaging acceleration in comparison to single-average fully encoded Fourier imaging is demonstrated. These results show that parallel imaging methods are efficient in ULF MRI, and that imaging performance of SQUID-based instruments improves substantially as the number of channels is increased.  相似文献   

4.
In ultra-low-field magnetic resonance imaging (ULF MRI), superconductive sensors are used to detect MRI signals typically in fields on the order of 10-100 μT. Despite the highly sensitive detectors, it is necessary to prepolarize the sample in a stronger magnetic field on the order of 10-100 mT, which has to be switched off rapidly in a few milliseconds before signal acquisition. In addition, external magnetic interference is commonly reduced by situating the ULF-MRI system inside a magnetically shielded room (MSR). With typical dipolar polarizing coil designs, the stray field induces strong eddy currents in the conductive layers of the MSR. These eddy currents cause significant secondary magnetic fields that may distort the spin dynamics of the sample, exceed the dynamic range of the sensors, and prevent simultaneous magnetoencephalography and MRI acquisitions. In this paper, we describe a method to design self-shielded polarizing coils for ULF MRI. The experimental results show that with a simple self-shielded polarizing coil, the magnetic fields caused by the eddy currents are largely reduced. With the presented shielding technique, ULF-MRI devices can utilize stronger and spatially broader polarizing fields than achievable with unshielded polarizing coils.  相似文献   

5.
Magnetic resonance imaging (MRI) allows measurement of electric current density in an object. The measurement is based on observing how the magnetic field of the current density affects the associated spins. However, as high-field MRI is sensitive to static magnetic field variations of only the field component along the main field direction, object rotations are typically needed to image three-dimensional current densities. Ultra-low-field (ULF) MRI, on the other hand, with B0 on the order of 10–100 μT, allows novel MRI sequences. We present a rotation-free method for imaging static magnetic fields and current densities using ULF MRI. The method utilizes prepolarization pulses with adiabatic switch-off ramps. The technique is designed to reveal complete field and current-density information without the need to rotate the object. The method may find applications, e.g., in conductivity imaging. We present simulation results showing the feasibility of the sequence.  相似文献   

6.
Nuclear-magnetic-resonance (NMR) measurement of laser-polarized gaseous129Xe produced by spin-exchange optical pumping with a narrow-linewidth laser at a high magnetic field of 4.7 T is reported. The samples are contained in the glass tubes. The nuclear spin polarization of the laserpolarized129Xe is 3.9%, and this corresponds to an enhancement of 9· 103 compared to the equilibrium value at 311 K and at the same magnetic field. The laser-enhanced129Xe NMR signals can be used in MR imaging.  相似文献   

7.
In order to assess the anisotropy constants of highly anisotropic thin film samples with anisotropy fields well above 10 T, Hall resistance measurements were conducted in pulsed magnetic fields. These measurements also deliver the anomalous Hall data, which are proportional to the perpendicular magnetisation. This specific approach combines the high field values obtainable by pulsed fields with a measurement technique sensitive enough to be applied to thin film samples. Two epitaxial Rare Earth-Cobalt thin films with large in-plane uniaxial magnetocrystalline anisotropy at room temperature were studied. The resulting anisotropy fields and constants are discussed with respect to measurements on single crystals and similar films investigated in quasi-static magnetic fields well below the anisotropy field. The present technique proved to be very valuable to highly anisotropic samples, as the approach to saturation is fully monitored and the data thus provides a more extended view on the hard axis magnetisation process.  相似文献   

8.
Composite materials of epoxy resins reinforced by carbon fibers are increasingly being used in the construction of aircraft. In these applications, the material may be thermally damaged and weakened by jet blast and accidental fires. The feasibility of using proton NMR relaxation times T1, T1rho, and T2 to detect and quantify the thermal damage is investigated. In conventional spectrometers with homogeneous static magnetic fields, T1rho is readily measured and is found to be well correlated with thermal damage. This suggests that NMR measurements of proton T1rho may be used for non-destructive evaluation of carbon fiber-epoxy composites. Results from T1rho measurements in the inhomogeneous static and RF magnetic fields of an NMR-MOUSE are also discussed.  相似文献   

9.
Nuclear magnetic resonance (NMR) may be used for monitoring temperature changes within samples based on measurements of relaxation times, the diffusion coefficient of liquids, proton resonance frequency or phase shifts. Such methods may be extended to the explicit measurement of the thermal diffusivity of materials by NMR imaging. A method based on measuring nuclear spin phase shifts or changes in the equilibrium nuclear magnetization has been developed for measuring transient thermal diffusion effects and thermal diffusivity with potential applications in NMR thermotherapy and materials science. In this method, a thermal pulse is applied to a medium, and the resultant temporal variations of the nuclear spin phase or of the magnitude of the nuclear magnetization produced by the thermal pulse are monitored at a spatial distance. The results obtained on common fluids agree well with the data from other methods.  相似文献   

10.
We describe and apply a scheme to obtain nuclear magnetic resonance (NMR) signals from multiple regions in space with a single pulse sequence in systems with strong, usually unavoidable, gradient magnetic fields. This is accomplished with multiple frequency irradiation and reception. Applications described include dual-slice NMR of a fluid to enhance S/N, T 2 measurements of two different samples, and efficient T 1 measurement sequence by interleaving shorter delays within a longer delay for different slices.  相似文献   

11.
12.
A narrow-gap, temperature-controlled Couette flow rheometer has been developed to study fluid velocities within the annular gap between two concentric cylinders by nuclear magnetic resonance (NMR) imaging and velocimetry. Alternative pulsed-field-gradient-based nuclear magnetic resonance imaging strategies which may be used for measurement of velocity within the Couette flow device have been evaluated. These include two-dimensional (2-D) imaging techniques with acquisition times of several minutes and a one-dimensional (1-D) projection method which exploits the symmetry of the device to reduce overall measurement time to less than 1 min. Velocity measurements made using each technique are presented for a Newtonian fluid undergoing Couette flow at shear rates of approximately 20 and 60 s–1.  相似文献   

13.
Solving the problem of concomitant gradients in ultra-low-field MRI   总被引:1,自引:0,他引:1  
In ultra-low-field magnetic resonance imaging (ULF MRI), spin precession is detected typically in magnetic fields of the order of 10-100 μT. As in conventional high-field MRI, the spatial origin of the signals can be encoded by superposing gradient fields on a homogeneous main field. However, because the main field is weak, gradient field amplitudes become comparable to it. In this case, the concomitant gradients forced by Maxwell's equations cause the assumption of linearly varying field gradients to fail. Thus, image reconstruction with Fourier transformation would produce severe image artifacts. We propose a direct linear inversion (DLI) method to reconstruct images without limiting assumptions about the gradient fields. We compare the quality of the images obtained using the proposed reconstruction method and the Fourier reconstruction. With simulations, we show how the reconstruction errors of the methods depend on the strengths of the concomitant gradients. The proposed approach produces nearly distortion-free images even when the main field reaches zero.  相似文献   

14.
Resistive and resistive-superconducting hybrid magnets can generate dc magnetic fields much higher than conventional superconducting NMR magnets but the field spatial homogeneity and temporal stability are usually not sufficient for high-resolution NMR experiments. Hardware and technique development addressing these issues are presented for high-resolution NMR at magnetic fields up to 40T. Passive ferromagnetic shimming and magic-angle spinning are used effectively to reduce the broadening from inhomogeneous magnetic field. A phase correction technique based on simultaneous heteronuclear detection is developed to compensate magnetic field fluctuations to achieve high spectral resolution.  相似文献   

15.
In magnetic resonance imaging (MRI), T(2)(*)-weighted contrast is significantly enhanced by extremely high magnetic field strength, offering broad potential applications. However, the T(2)(*)-weighted image contrast distortion and signal loss artifact arising from discontinuities of magnetic susceptibility within and around the sample are also increased, limiting utilization of high field systems for T(2)(*)-weighted contrast applications. Due to the B(0) dependence of the contrast distortions and signal losses, and the heterogeneity of magnetic susceptibility in biological samples, magnetic susceptibility artifacts worsen dramatically for in vivo microimaging at higher fields. Practical applications of T(2)(*)-sensitive techniques enhanced by higher magnetic fields are therefore challenged. This report shows that magnetic susceptibility artifacts dominate T(2)(*)-weighted image contrast at 14 T, and demonstrates that the GESEPI (gradient echo slice excitation profile imaging) technique effectively reduces or eliminates these artifacts at long TE in the highest field (14 T) currently available for (1)H imaging.  相似文献   

16.
Nuclear Magnetic Resonance (NMR) experiments in pulsed high magnetic fields up to 62T at the Dresden High Magnetic Field Laboratory (Hochfeld-Magnetlabor Dresden) are reported. The time dependence of the magnetic field is investigated by observing various free induction decays (FIDs) in the vicinity of the maximum of the field pulse. By analyzing each FID's phase and its evolution with time the magnetic field's time dependence can be determined with high precision. Assuming a quadratic or cubic dependence on time near the field maximum its confidence is found to be better than ± 0.03ppm at low fields and ± 0.8ppm near 62T. In turn, the thus obtained time dependence of the field can be used to demodulate and phase-correct all FIDs so that they appear phase-locked to each other. As a consequence signal averaging is possible. The increase in signal-to-noise ratio is found to be close to that expected theoretically. This shows that the intrinsic time dependence of the pulsed fields can be removed so that the NMR signals appear to be taken at rather stable static field. This opens up the possibility of performing precise shift measurements and signal averaging also of unknown, weak signals if a reference signal is measured during the same field pulse with a double-resonance probe.  相似文献   

17.
A previously published nuclear magnetic resonance (NMR) spectroscopic imaging method for mapping static magnetic fields has been modified, replacing the gradient echo sequence with an asymmetric spin echo sequence. The purpose of the modification is to reinforce the technique and make it useable even in conditions in which the gradient echo sequence cannot be operated. The modification performed was verified by an experiment performed on a low-field NMR scanner. The rough and fine errors due to the long time of measurement were corrected during the processing of the measured images. An optimization procedure was used to correct the fine errors. The map of the static magnetic field acquired using the new technique was compared to the map calculated from the phase images and both were compared to the result measured using a magnetometer. The verification confirmed the legitimacy of the modification and suitability of the novel technique. Some alternatives to the measured data processing have been suggested, shortening the global time of the measurement.  相似文献   

18.
Magnetic field cycling in nuclear magnetic resonance (NMR) experiments has been used since the early days of NMR. Originally such time-dependent magnetic field experiments were motivated to study cross relaxation, spin system thermodynamics and indirect detection of quadrupolar resonance. The first apparatus used mechanical or pneumatic systems to shoot the sample between two magnets, the typical “flying time” being a few hundreds of milliseconds. As a natural evolution of the experimental technique and the need to extend its application to samples with higher relaxation rates, faster magnetic field switching devices were developed during the last years. Special electric networks combined with sophisticated air core magnets allowed one to switch magnetic fields between zero and fields of the order of 0.5 T in a few milliseconds. Today we refer to this new generation of instruments as “fast-field-cycling” devices. The technique has been successfully used during the last years to obtain information on the molecular dynamics and order in different materials, ranging from organic solids, metals, polymers, liquid crystals, porous media to biological systems. At present it is also turning to be an important tool for the design of contrast agents for magnetic resonance imaging. Fast field cycling was mainly oriented toT 1 relaxometry as a unique technique offering a dynamic window of several decades, ranging from few kilohertz to several megahertz. However, there exist less conventional applications of the technique that can also provide relevant information concerning molecular dynamics, structure and molecular order. In this article we will briefly deal with basic aspects of the technique, its evolution, present-day relevant applications and the last improvements concerning specialized instrumentation.  相似文献   

19.
Kaolin clay samples were mixed with various amounts of Fe2O3 powder. The influence of this magnetic impurity on NMR relaxation and diffusion measurements on the water in this porous material was investigated. The NMR relaxation measurements showed a nearly mono-exponential decay, leading to the conclusion that the pore size distribution of the clay samples is either narrow and/or that the pores are interconnected very well. Both the longitudinal and the transverse relaxation rate depend linearly on the concentration of the Fe2O3 impurity. The NMR diffusion measurements revealed that the Fe2O3 causes internal magnetic field gradients that largely exceed the maximum external gradient that could be applied by our NMR apparatus (0.3 T/m). Additional SQUID measurements yielded the magnetization and magnetic susceptibility of the samples at the magnetic field strength used in the NMR measurements (0.8 T). A theoretical estimate of the internal magnetic field gradients leads to the conclusion that the water in the porous clay samples cannot be described by the commonly observed motional averaging regime. Probably an intermediate or a localization regime is induced by the large internal gradients, which are estimated to be on the order of 1 to 10 T/m in the pore volume and may exceed 1000 T/m at the pore surface.  相似文献   

20.
A new method for measuring and exploiting the magnetic field dependence of chemically induced dynamic nuclear polarization (CIDNP) is described. A solution of an amino acid or protein together with a flavin photosensitizer is irradiated with laser light at a position in the bore of a superconducting NMR magnet where the field is between 0.1 T and 7.0 T. The polarized sample is then transferred by rapid injection into an NMR tube at the centre of the magnet (at 9.4 T), where the spectrum is recorded. The observed 1H CIDNP field dependence of tyrosine agrees well with the diffusion model of the radical pair mechanism. The field dependence of histidine, tryptophan and methionine CIDNP allows the g values of the transient radicals responsible for the polarization to be determined. Experiments in which amino acids compete for the photoexcited flavin indicate that methionine residues could be used as probes of surface accessibility, especially if the polarization is generated in low fields (~ 0.7 T) and detected in high fields (≥ 9.4 T). Possible extensions of the technique to study protein folding and the structures of partially denatured states of proteins are discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号