首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
A sensitive, simple, and accurate method for determination and pharmacokinetic study of ferulic acid and isoferulic acid in rat plasma was developed using a reversed-phase column liquid chromatographic (RP-LC) method with UV detection. Sample preparations were carried out by protein precipitation with the addition of methanol, followed by evaporation to dryness. The resultant residue was then reconstituted in mobile phase and injected into a Kromasil C18 column (250 × 4.6 mm i.d. with 5 μm particle size). The mobile phase was methanol-1% formic acid (33:67, v/v). The calibration plots were linear over the range 5.780–5780 ng·mL?1 for ferulic acid and 1.740–348.0 ng·mL?1 for isoferulic acid. Mean recoveries were 85.1% and 91.1%, respectively. The relative standard deviations (RSDs) of within-day and between-day precision were not above 15% for both of the analytes. The limits of quantification were 5.780 ng·mL?1 for ferulic acid and 1.740 ng·mL?1 for isoferulic acid. This RP-LC method was used successfully in pharmacokinetic studies of ferulic acid and isoferulic acid in rat plasma after intravenous injection of Guanxinning Lyophilizer.  相似文献   

2.
《Analytical letters》2012,45(13):1764-1776
A rapid, sensitive, and specific high-performance liquid chromatography tandem mass spectrometric method was developed for the simultaneous determination and confirmation of amoxicillin and clavulanic acid in plasma. Plasma sample was subjected to a simple deproteinization with acetonitrile, and then the supernatant was directly diluted by water. Analysis was performed on a Phenomenex Luna C8 reversed-phase column by detection with mass spectrometry in negative ions multiple reaction monitoring mode. A gradient elution program with 0.1% formic acid and acetonitrile was performed at a flow of 0.25 mL min?1. There is good linearity in the range of 0.5–500 ng mL?1 for both amoxicillin and clavulanic acid. The decision limits of amoxicillin and clavulanic acid were 0.06 ng mL?1 and 0.08 ng mL?1 in plasma, respectively, and the detection capabilities of two analytes were below 0.5 ng mL?1. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The extraction recoveries of amoxicillin and clavulanic acid were between 102% and 115% in plasma at three spiked levels of 0.5, 50, and 500 ng mL?1, with the relative standard deviations less than 15% for each analyte. The developed method was applied to pharmacokinetic studies of amoxicillin and clavulanic acid tablets in healthy beagles.  相似文献   

3.
A simple, sensitive, and precise high performance liquid chromatographic method for the analysis of pantoprazole, rabeprazole, esomeprazole, domperidone and itopride, with ultraviolet detection at 210 nm, has been developed, validated, and used for the determination of compounds in commercial pharmaceutical products. The compounds were well separated on a Hypersil BDS C18 reversed-phase column by use of a mobile phase consisting of 0.05 M, 4.70 pH, potassium dihydrogen phosphate buffer - acetonitrile (720:280 v/v) at a flow rate of 1.0 mL min?1. The linearity ranges were 400–4,000 ng mL?1 for pantoprazole, 200–2,000 ng mL?1 for rabeprazole, 400–4,000 ng mL?1 for esomeprazole, 300–3,000 ng mL?1 for domperidone and 500–5,000 ng mL?1 for itopride. Limits of detection (LOD) obtained were: pantoprazole 147.51 ng mL?1, rabeprazole 65.65 ng mL?1, esomeprazole 131.27 ng mL?1, domperidone 98.33 ng mL?1 and itopride 162.35 ng mL?1. The study showed that reversed-phase liquid chromatography is sensitive and selective for the determination of pantoprazole, rabeprazole, esomeprazole, domperidone and itopride using single mobile phase.  相似文献   

4.
A method combining immunoaffinity chromatography with gas chromatography–mass spectrometry (GC–MS) has been established for determination of ractopamine residues in swine liver and urine. After clean-up on an immunoaffinity chromatography column, GC–MS analysis revealed recovery from blank swine liver and urine fortified at 2.5–20 ng g?1 (ng mL?1 for urine), respectively, was 68.2–78.6 and 76.2–83.1%. The limits of detection and quantification were 0.5 ng g?1 (or ng mL?1) and 2.0 ng g?1 (or ng mL?1), respectively. The procedure was used for analysis of ractopamine residues in samples of swine liver and urine in which the levels were unknown. The amounts detected were 9–216 ng g?1 (ng mL?1).  相似文献   

5.
A simple, rapid and sensitive liquid chromatography/electrospray tandem mass spectrometry quantitative detection method, using amantadine as internal standard, was developed for the simultaneous analysis of paracetamol, pseudoephedrine and chlorpheniramine concentrations. Analytes were extracted from plasma samples by liquid–liquid extraction with n-hexane–dichloromethane–2-propanol (2:1:0.1, v/v), separated on a C18 reversed-phase column with 0.1% formic acid–methanol (40:60, v/v) and detected by electrospray ionization mass spectrometry in positive multiple reaction monitoring mode. Calibration curves for plasma were linear over the concentration range 10–10,000 ng mL?1 of paracetamol, 2–2,000 ng mL?1 of pseudoephedrine and 0.2–200 ng mL?1 of chlorpheniramine. The method has a lower limit of quantitation of 10 ng mL?1 for paracetamol, 2.0 ng mL?1 for pseudoephedrine and 0.2 ng mL?1 for chlorpheniramine. Recoveries, precision and accuracy results indicate that the method was reliable within the analytical range, and the use of the internal standard was very effective for reproducibility by LC-MS-MS. This method is feasible for the evaluation of pharmacokinetic profiles of a novel multicomponent sustained release formulation containing 325 mg of paracetamol, 30 mg of pseudoephedrine hydrochloride and 2 mg of chlorpheniramine maleate. It is the first time the pharmacokinetic evaluation of a novel sustained-action formulation containing paracetamol, pseudoephedrine and chlorpheniramine has been elucidated in vivo using LC-MS-MS.  相似文献   

6.
Guo  Xiaorui  Chen  Xiaohui  Cheng  Weiming  Yang  Kaiyu  Ma  Yongfen  Bi  Kaishun 《Chromatographia》2008,67(11):1007-1011

A sensitive, simple, and accurate method for determination and pharmacokinetic study of ferulic acid and isoferulic acid in rat plasma was developed using a reversed-phase column liquid chromatographic (RP-LC) method with UV detection. Sample preparations were carried out by protein precipitation with the addition of methanol, followed by evaporation to dryness. The resultant residue was then reconstituted in mobile phase and injected into a Kromasil C18 column (250 × 4.6 mm i.d. with 5 μm particle size). The mobile phase was methanol-1% formic acid (33:67, v/v). The calibration plots were linear over the range 5.780–5780 ng·mL−1 for ferulic acid and 1.740–348.0 ng·mL−1 for isoferulic acid. Mean recoveries were 85.1% and 91.1%, respectively. The relative standard deviations (RSDs) of within-day and between-day precision were not above 15% for both of the analytes. The limits of quantification were 5.780 ng·mL−1 for ferulic acid and 1.740 ng·mL−1 for isoferulic acid. This RP-LC method was used successfully in pharmacokinetic studies of ferulic acid and isoferulic acid in rat plasma after intravenous injection of Guanxinning Lyophilizer.

  相似文献   

7.
《Analytical letters》2012,45(2):286-298
Based on the available rabbit monoclonal antibody (RabMAb), a rapid and sensitive lateral flow immunoassay (LFA) platform has been developed for quantitative detection of four sulfonamide residues(SRs) of sulfadiazine (SD), sulfathiazole (STZ), sulfapyridine (SP), and sulfamethoxazole (SMX).Within the designed LFA competitive format assay, which was based on antigen-antibody properties, the hapten conjugate N1-[4-(carboxymethyl)-2-thiazolyl] sulfanilamide linked to protein ovalbumin (TS-OVA) and goat anti-rabbit antibody were sprayed as capture and control reagents, respectively, and then the antibody was conjugated to colloidal gold particles as the detection reagent. With quantitative assessment aided by a colorimetric strip reader, the sensitivities of the established LFA method for SD, STZ, SP, and SMX were 0.91 ng mL?1, 0.10ng mL?1,0.12ng mL?1, and 2.13ng mL?1, and the half-maximum inhibition concentrations (IC50) were 5.19 ng mL?1, 1.25 ng mL?1, 0.66 ng mL?1, and 24.14 ng mL?1, respectively. The recoveries at three spiked levels (5, 20, 50 ng mL?1for SD, STZ, and SP; 20, 50, 100 ng mL?1 for SMX) were in the range of 78.02–135.10% and 76.40–137.16% for milk and swine urine, respectively. More importantly, the detection performance of the established platform was consistent with that of in-parallel LC-MS/MS analysis. In conclusion, the proposed LFA platform has showed the potential for fast, sensitive and relatively accurate quantification of four sulfonamide residues in practical uses.  相似文献   

8.
Here, we report a rapid and specific method based on high-performance liquid chromatography coupled with tandem mass spectrometry (LC–MS–MS) capable of quantifying six CYP450-specific probe substrates in human liver microsomal incubation mixtures simultaneously. These analytes were prepared by single-step extraction and detected in one run by switching polarity of electrospray ionization mode three times. Following optimization of the chromatographic conditions, the peaks were well separated, and retention times ranged between 2.0 and 8.4 min. The total run time for a single injection was within 9 min. This method was fully validated over linear range of 18.8–3,000.0 ng mL?1 for diclofenac, 0.8–3,000.0 ng mL?1 for dapson, 1.5–3,000.0 ng mL?1 for dextromethorphan, 2.0–4,000.0 ng mL?1 for omeprazole, 75.0–3,000.0 ng mL?1 for chlorzoxazone and 0.8–3,000.0 ng mL?1 for phenacetin using diazepam as internal standard. Samples were prepared by protein precipitation and analyzed on the LC–MS–MS equipped with ESI interface. For each analyte, inter- and intra-day precision (RSD%) were <15 % and accuracy was within 85–115 %. The specificity, precision, accuracy, stabilities and matrix effect were evaluated.  相似文献   

9.
A rapid LC method with UV detection was developed for the quantification of carboxylic acid metabolite of clopidogrel in human plasma. Following a simple protein precipitation using a mixture of methanolic solution of ZnSO4, the analyte and commercially available internal standard were separated using a mobile phase of water–acetonitril (85:15, v/v) adjusted to pH 3.5 on a Chromolith C18 column at a flow rate of 2.5 mL min?1 with a total retention time of 4 min. Linearity was verified over the range of 20–3,000 ng mL?1 where the LOQ was 20 ng mL?1. This method was applied in a pharmacokinetic study.  相似文献   

10.
A liquid chromatography–electrospray ionization tandem mass spectrometry method has been developed to perform the determination of 5-hydroxytryptamine (5-HT), norepinephrine (NE), dopamine (DA) and their metabolites, i.e., 5-hydroxyindole-3-acetic acid (5-HIAA), 4-hydroxy-3-methoxyphenylglycol (MHPG) sulfate, 3,4-dihydroxyphenylacetic acid (DOPAC) and homovanillic acid (HVA) in rat brain tissue. Analytes were separated on a Thermo C18 column (4.6 mm × 250 mm, 5 μm, SN: 1245575T, Thermo electron corporation, USA) with a mobile phase of 0.05% formic acid/acetonitrile (92:8 for ESI+, 82:18 for ESI?, v/v) at the flow-rate of 0.8 mL min?1. The LC system was coupled to a Waters Micromass Quattro Premier XE tandem quadruple mass spectrometer. MS acquisition of 5-HT, NE and DA was performed in positive electrospray ionization multiple reaction monitoring (MRM) mode, while negative electrospray ionization MRM mode was used to monitor their metabolites. The calibration curves were linear within the concentration range of 4–4,450 ng mL?1 for 5-HT, 4–4,110 ng mL?1 for NE and 4–4,100 ng mL?1 for DA (≥ 0.999). The limit of quantitation was 4 ng mL?1. 5-HIAA, MHPG, DOPAC and HVA have good linearity within the range of 12–1,000 ng mL?1(≥ 0.998) and the limit of quantitation was 12 ng mL?1. The intra- and inter-day RSD were lower than 8.45%. The method is sensitive, fast, accurate and usable for quantity determination of monoamine neurotransmitters and their metabolites in neuropsychiatric diseases.  相似文献   

11.
A highly sensitive liquid chromatographic-atmospheric pressure chemical ionization-tandem mass spectrometric method is developed to quantitate phenacetin and its metabolite paracetamol in rabbit plasma. The analytes and internal standard oxazepam are extracted from plasma by liquid–liquid extraction using ethyl acetate, and separated on a Zorbax SB-C18 column (2.1 mm × 150 mm, 5 μm) using acetonitrile–0.1% formic acid in water (40:60 v/v) at a flow of 0.4 mL min?1. Detection is carried out by multiple reaction monitoring on a ion-trap LC-MS-MS system with an atmospheric pressure chemical ionization interface. The assay is linear over the range 4–1,600 ng mL?1 for phenacetin and 3–2,000 ng mL?1 for paracetamol, with a lower limit of quantitation of 4 ng mL?1 for phenacetin and 3 ng mL?1 for paracetamol. Intra- and inter-day precision are less than 7.1% and the accuracy are in the range 97.3–103.5%. The validated method is successfully used to analyze the drug in samples of rabbit plasma for pharmacokinetic study.  相似文献   

12.
Bengi Uslu  Tugba Özden 《Chromatographia》2013,76(21-22):1487-1494
High efficiency and less elution are the basic requirements of high-speed chromatographic separation. In this study, a new gradient reverse phase chromatographic methods were developed using HPLC and UPLC systems for simultaneous determination of enalapril maleate (ENL) and hydrochlorothiazide (HCZ) in pharmaceutical dosage forms. The chromatographic separations of ENL and HCZ were achieved on a Waters μ-Bondapak C 18, (300 × 3.9 mm, 10 μm) and Waters Acquity BEH C18 (100 × 2.1 mm, 1.7 μm) columns for HPLC within 5.30 min and UPLC within a short retention time of 1.95 min, respectively. A linear response was observed over the concentration range 0.270–399 μg mL?1 of ENL, 0.260–399 μg mL?1 of HCZ for HPLC system and 0.270–399 μg mL?1 of ENL and 0.065–249 μg mL?1 of HCZ for UPLC system. Also, limit of detection for ENL was 1.848 ng mL?1 and 31.477 ng mL?1 for HCZ, 2.804 ng mL?1 for ENL and 2.943 ng mL?1 for HCZ using HPLC and UPLC, respectively. The proposed methods were validated according to ICH guideline with respect to precision, accuracy, and linearity. Forced degradation studies were also performed for both compounds in bulk drug samples to demonstrate the specificity and stability indicating power of the HPLC method. Comparison of system performance with conventional HPLC was made with respect to analysis time, efficiency, and resolution.  相似文献   

13.
《Analytical letters》2012,45(16):2643-2654
Dispersive liquid–liquid microextraction based on solid formation without a disperser combined with high-performance liquid chromatography has been developed for the determination of 4-tert-butylphenol, 4-n-nonylphenol, and 4-tert-octylphenol. This method is rapid, easy, and uses only 10 µL of a low toxicity organic solvent (1-hexadecanethiol) for the extraction solvent and no disperser solvent. The extraction time and centrifugation time require less than 10 min. The linear range was 1–500 ng mL?1 for 4-tert-butylphenol, 2–1000 ng mL?1 for 4-tert-octylphenol, and 5–500 ng mL?1 for 4-n-nonylphenol with r2 ≥ 0.9986. The detection limits were between 0.2 and 1.5 ng mL?1. The recoveries of lake and river water samples were in the range of 79% to 108%, and the relative standard deviations were 5% to 10%.  相似文献   

14.
A rapid and sensitive reversed-phase high performance liquid chromatography– fluorescence-mass spectrometer (RP-HPLC–FLD-MS) method based on pre-column derivatization using 2-(5-benzoacridine)ethyl-p-toluenesulfonate (BAETS) as labelling reagent has been developed for simultaneous determination of five triterpenic acids (asiatic acid (AA), maslinic acid (MA), corosolic acid (CA), oleanolic acid (OA), and betulinic acid (BA). The presented method was validated for linearity (correlation coefficient R2 > 0.9994), precision (RSD 2.1%–3.9%) and reproducibility (RSD 0.01%–2.1%). The limits of detection (LODs) and the limits of quantitation LOQs were within the range of 0.71–1.02 ng mL?1 and 2.28–3.24 ng mL?1, respectively. The proposed method was successfully applied to simultaneously determine five triterpenic acids of four Corydalis plants and showed satisfactory reproducibility and credibility. Moreover, several main parameters affecting extraction procedure and derivatization efficiency were investigated by response surface methodology (RSM), respectively. Triterpenic acid content in four Corydalis plants was measured according to the established method and the results indicated that triterpenic acid contents were various in different organs and herbs.  相似文献   

15.
《Analytical letters》2012,45(16):2655-2664
Sample preparation technique based on an organic filter membrane (pH-resolved filter membrane microextraction) (pH-RFMME) was developed, coupled with high-performance liquid chromatography, and used to determine protoberberine alkaloids (jatrorrhizine, epiberberine, coptisine, palmatine, and berberine) in Coptis chinensis at different pH values through a one-step procedure. This green procedure provides a desirable sample pretreatment technology. The main variables affecting the extraction such as filter membrane area (or volumes of extraction solvents), sample pH, eluent pH, ionic strength, extraction stirring rate, extraction time, and sample volume were optimized. Under the optimized conditions, the enrichment factors of the analytes were 40.4–52.0, the linear ranges were 3.2–6250 ng · mL?1 for jatrorrhizine and epiberberine, 6.0–12000 ng · mL?1 for coptisine, 1.8–3600 ng · mL?1 for palmatine, and 18.8–18800 ng · mL?1 for berberine, with r 2 ≥ 0.9945. The limits of detection were less than 0.3 ng · mL?1. Satisfactory recoveries (84.8%–115.5%) and precision (1.8%–10.0%) were also achieved. These results confirmed that pH-RFMME is a simple, rapid, practical, and environmentally friendly method to isolate analytes that exhibit significant differences in acidity or alkalinity from complex samples.  相似文献   

16.
A gradient liquid chromatography-tandem mass spectrometry method has been developed and validated for the determination of gastrodin and ligustrazine hydrochloride in rat plasma and brain dialysates. Zolpidem was used as internal standard. For plasma samples, solid-phase extraction was used and the brain dialysates were collected from freely moving rats using brain microdialysis. Both were followed by HPLC separation and positive electrospray ionization tandem mass spectrometry detection (ESI–MS–MS). Chromatographic separation was achieved on a Symmetry RP-18 column using gradient elution with methanol and water containing 0.5% formic acid and 2 mM ammonium formate. Selected reaction monitoring (SRM) mode was used for quantitation. Good linearities were obtained in the range of 0.05–100 and 0.01–50 μg mL?1 for gastrodin and ligustrazine hydrochloride in rat plasma, and 0.05–1,000 ng mL?1 for both in dialysate. The lower limit of quantitation was 0.01 ng mL?1 for gastrodin and 0.05 ng mL?1 for ligustrazine. The method is precise and reliable and can be applied to pharmacokinetic studies.  相似文献   

17.
《Analytical letters》2012,45(5):766-782
A combined homogeneous assay and colorimetric determination method using gold nanoparticles was developed for rapid determination of lead(II) in contaminated natural waters. The presence of lead(II) in the colloidal gold suspension causes a change in the absorbance of the suspension. An increase in the absorption property at 595 nm is accompanied by a change in the size of the gold nanoparticles. High concentrations of lead cause aggregation of the gold colloids. Colloidal gold nanoparticles were synthesized using tannic acid as the reducing agent; this reagent allowed selective determination of lead in 10 µL of water, with a detection limit of 310 ng mL?1 with an analysis time of 5 min. The coefficient of variation for lead(II) within the working range of the assay (520 ng mL?1–13 µg mL?1) varied from 1.3% to 9.2%. The limit of detection using this method with a sample volume of 50 µL was 60 ng mL?1. The coefficient of variation for lead over the working range of the determined concentrations (80 ng mL?1–25 µg mL?1) varied from 0.2% to 9.3%, while the values for the inter-day assay (n = 8) were less than 10%. The method was employed for the analysis of river, lake, marsh, and spring water; the recovery of lead was determined to be 72.5%–130% for 10 µL of water and 93.6%–114.7% for 50 µL.  相似文献   

18.
《Analytical letters》2012,45(3):466-475
A Chemiluminescent Enzyme-Linked Immuno-Sorbent Assay (CL-ELISA) for determination and quantification of the fungicide imidacloprid in honeybees was developed in an indirect competitive format. The assay was optimized by determining: the optimal coating conjugate concentration and anti-imidacloprid antiserum dilution, the effect of the incubation time on the competitive step, and the tolerance to organic solvents. The IC50 and the limit of detection (LOD) values were 14.8 ng mL?1 and 0.11 ng mL?1, respectively, similar to those of colorimetric ELISA with a calibration range of 0.1–2600 ng mL?1. Cross reactivity of some related compounds such as three imidacloprid metabolites, 6-chloro nicotinic acid, 5-hydroxy-imidacloprid, and imidacloprid olefin, and one other chloronicotinoid insecticide, acetamiprid, were tested. The assay was then applied to honeybee extracts obtained by using the liquid-liquid extraction. The calibration curves in honeybee extracts from the liquid-liquid procedure gave an IC50 of 23.7 ng mL?1 and a LOD 1.6 ng mL?1. The average recovery value from honeybee extracts spiked with 100 and 1000 ng mL?1 of imidacloprid were 73% and 76%, respectively. Finally, the assay was applied to honeybee samples collected during monitoring activities in Italy; it was found that only five of the 27 samples were positives, with low concentrations of imidacloprid ranging between 1.2 and 15.4 ng g?1.  相似文献   

19.
A selective, sensitive, and accurate method has been developed and validated for the quantification of tangeretin in rat plasma. The application of LC-electrospray-ion trap mass spectrometry in full scan and multiple reactions monitoring modes were investigated. Following solid phase extraction using a hydrophilic–lipophilic balance cartridge, the analytes were separated on a C18 column using an isocratic mobile phase composed of acetonitrile/water (50:50, v/v) containing 0.3% formic acid. In full scan mode, the LOQ was 2 ng mL?1. The standard calibration curve was linear (R 2 = 0.9999) over the concentration range 2–200 ng mL?1. The precision over the concentration range was within 15% (RSD) and the accuracy was ranged from 86 to 115%. In multiple reaction monitoring mode, the LOQ was 1 ng mL?1 and the standard calibration curve was linear (R 2 = 0.9976) over the concentration range 1–100 ng mL?1 with a precision of 12% and accuracy rangeing from 91 to 113%.  相似文献   

20.
A reliable and sensitive liquid chromatographic–tandem mass spectrometric method, with rutin as internal standard, has been developed and validated for simultaneous determination of danshensu, salvianolic acid B (SAB), and hydroxysafflor yellow A (HSYA) in beagle dog plasma. Plasma samples spiked with the analytes were extracted by solid-phase extraction and the analytes were separated on a 250 × 4.6 mm i.d., 5-μm particle, C18 column with methanol–acetonitrile–0.5% formic acid 20:25:55 (v/v) as mobile phase at a flow rate of 1 mL min?1. LC–MS–MS analysis was performed with a Finnigan TSQ triple-quadrupole tandem mass spectrometer operated in negative-ion selected-reaction-monitoring mode, using electrospray ionization. The accuracy and precision of the method were acceptable and linearity was good over the range 20–4,000 ng mL?1 for danshensu, 50–10,000 ng mL?1 for SAB, and 10–2,000 ng mL?1 for HSYA. The method was successfully applied to a pharmacokinetic study of a traditional Chinese medicinal preparation, Danhong lyophilized powder for injection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号