首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A new and simple extraction spectrophotometric method for the determination of vanadium(V) with KIO4, N‐phenylbenzohydroxamic acid (PBHA) and crystal violet (CV), in industrial waste water samples is described. It is based on the extraction of mixed‐ligand complex V(V)‐IO4? ‐PBHA‐CV+ into chloroform solution over 2‐7 MHC1. The molar absorptivity of the complex is (7.20) × 1031 mol?1 cm?1 at λmax 535 nm. The detection limit of the method is 44 μg 1?1 V. The linearity of the calibration curve is followed up to 6 μgmL?1 in the organic solution with slope, intercept and correlation coefficient of 1.34 × 10?1, 6.7 × 10?3 and +0.99, respectively. This method enhances the sensitivity of the conventional PBHA method for the determination of vanadium, and is free from interferences of other metal ions commonly associated with vanadium. The method has been successfully tested for the determination of V in the industrial waste water samples.  相似文献   

2.
Feng NC  Xu BX  Bai ZP  Fang YZ 《Talanta》1994,41(11):1841-1844
A fluorescence quenching method is described for the determination of trace amounts of vanadium(V) based on the formation of a complex in acidic medium with a new reagent [1(3-methoxysalicylideneamino)-8-hydroxy-3,6-naphthalene disulfonic acid, disodium salt]. The fluorescence emission is measured at 415 nm (wavelength of excitation 360 nm), and the experimental variables and interferences in this determination have been studied. The detection limit is 12.5 ng/ml and linear range is between 50 and 600 ng/ml. The method has been applied to determine trace vanadium(V) in steel and cast iron.  相似文献   

3.
A simple and sensitive kinetic-spectrophotometric method is developed for the determination of trace vanadium(V), based on the catalytic effect of vanadium(V) on the oxidation of DBM-arsenazo by potassium bromate in 0.0138 moll(-1) phosphoric acid medium and at 100 degrees C in the presence of citric acid as activator. The absorbance is measured at 528 nm with the fixed-time method. The optimization of the operating conditions regarding concentrations of the reagents, temperature and interferences are also investigated. The working curve is linear over the concentration range 0-20 ngml(-1) of vanadium(V) with good precision and accuracy and the detection limit was down to 3.44 ngl(-1). The relative standard deviation for a standard solution of 14 ngml(-1) is 0.28% (n=11). The apparent activity energies of the catalytic reaction and the non-catalytic reaction are 73.48, 113.5 kJ/mol, respectively. The proposed method proved highly sensitive, selective and relatively rapid for the assay of vanadium at low-level range of 0-20 ngml(-1) without any pre-concentration step. Thw method was applied to the determination of vanadium(V) in steels, rice, flour, cabbage, potato, fish, shrimp and tea samples with satisfactory results. The obtained results for the steel samples were excellent agreement with the standard reference values. The analytical results of the rice, flour, cabbage, potato, fish, shrimp and tea samples were excellent agreement with those of atomic absorption spectrometry. The recovery experiments have been made for the rice, flour, cabbage, potato, fish, shrimp and tea samples except the steels; excellent results were obtained. The relative standard deviations were over the range of 0.18-2.60% and the recoveries were over the range of 98.00-102.4%, respectively. The analytical results obtained were satisfactory.  相似文献   

4.
钒对许多均相反应都有催化作用,但利用催化光度法测定痕量钒国内研究较少。作者发现钒(Ⅴ)对稀硫酸介质中溴酸钾氧化溴酚蓝褪色的反应有催化作用,通过条件试验,建立了利用这一新指示反应催化光度法测定痕量钒的方法。  相似文献   

5.
催化动力学褪色光度法测定痕量钒   总被引:15,自引:0,他引:15  
刘长增 《分析化学》2000,28(12):1481-1484
基于磷酸和棉红在沸水发色条件下反应生成的产物在钒(Ⅴ)催化下被KBrO3氧化而建立了一个测定超痕量钒的新方法,方法选择性好;测定范围是0.00-0.70μg/L,检测出限量7.3*10^-12g/mL,方法用于芹菜、人体血清和井水中超痕量钒的测定,获得了满意结果。  相似文献   

6.
钒(Ⅴ)催化氧化甲基紫的反应动力学及其应用   总被引:5,自引:0,他引:5  
在 H2 SO4 介质中 ,以抗坏血酸为活化剂 ,痕量的钒 ( )可强烈地催化溴酸钾氧化甲基紫的反应 ,研究了反应的最佳条件及动力学参数 ,探讨了反应机理 ,建立了测定超痕量钒的高灵敏方法 ,方法的线性范围 0 .0~ 2 50 pg/m L ,检出限为 6.5×1 0 - 13g/m L。方法用于井水、蔬菜及血清中痕量钒的测定 ,获得令人满意的结果  相似文献   

7.
催化动力学极谱法测定痕量钒   总被引:4,自引:0,他引:4  
在硫酸介质中,以酒石酸为活化剂,痕量钒对溴酸钾氧化甲基橙的反应有极强的催化作用,以极谱法监测催化反应过程中甲基橙及其氧化产物浓度的变化,建立了双峰指示催化动力学极谱法制定痕量钒的新方法,方法的线性范围为0.23-3.70μg/L,检出限为0.17μg/L。方法已用于食品及水样中痕量钒的测定。  相似文献   

8.
Mallett RC  Pearton DC  Ring EJ  Steele TW 《Talanta》1972,19(2):181-195
A number of serious interferences in the determination of the noble metals by atomic-absorption spectrophotometry have been investigated, and ways of eliminating them considered. The use of the nitrous oxide and acetylene flame reduced many of the interferences but also reduced the sensitivity. Additions of lanthanum, copper sulphate, copper + cadmium sulphate, uranium, and vanadium as releasing agents were effective in the removal of interferences for one or more of the noble metals in the air-acetylene flame. Uranium additions were found to be effective in removing mutual interferences associated with the noble metals (osmium and indium were not tested) whereas vanadium removed mutual and base-metal interferences. The precision and accuracy of methods of analysis based on the use of uranium and vanadium were acceptable, and the application of these methods to the analysis of noble metals collected by various procedures is briefly discussed.  相似文献   

9.
Chakrabarti AK 《Talanta》1995,42(9):1279-1283
A sensitive and selective photometric method for the trace determination of vanadium with cinnamohydroxamic acid extracted from 1.8 M HCl in methyl isobutyl ketone is described. The wine-red chelate formed under an optimum acidity of 1.3-2.6 M HCl absorbs with a maximum at 525 nm. Beer's law is obeyed in the range 0-8 ppm of vanadium(V) and the optimum range of determination of vanadium is found to be 1-8 ppm. The molar absorptivity and Sandell's sensitivity are 6.0 x 10(3) l mol(-1) cm(-1) and 0.0086 mug cm(-2) of vanadium(V) at 525 nm. The photometric determination of trace amounts of vanadium in materials such as alloys, minerals and rock ores is also reported. The solvent extraction methods are simple, rapid and highly selective with fluoride used as a masking agent for Fe and Ti. The standard deviations are minimal and the mean error is only 0.015%.  相似文献   

10.
A kinetic-spectrophotometric method for the determination of trace amounts of vanadium(V) is described. It is based on the catalytic action of this ion on the oxidation of 1,4-dihydroxyphthalimide dioxime by bromate, which yields a red-violet product in acidic medium. The reaction is followed spectrophotometrically by measuring the rate of change in absorbance at 500 nm and 30°C. Using several kinetic methods (tangent, fixed-time and fixed-absorbance), vanadium(V) in the range 10–400 ng ml?1 can be determined. The proposed methods are hardly subject to interferences. The tangent method was used for the determination of vanadium in atmospheric particulate matter, human serum and synthetic mixtures. The kinetic parameters of the catalysed and uncatalysed reactions are reported.  相似文献   

11.
Ahmed MJ  Banoo S 《Talanta》1999,48(5):711-1094
The very sensitive, fairly selective direct spectrophotometric method for the determination of trace amount of vanadium (V) with 1,5-diphenylcarbohydrazide (1,5-diphenylcarbazide) has been developed. 1,5-diphenylcarbohydrazide (DPCH) reacts in slightly acidic (0.0001–0.001 M H2SO4 or pH 4.0–5.5) 50% acetonic media with vanadium (V) to give a red–violet chelate which has an absorption maximum at 531 nm. The average molar absorption coefficient and Sandell’s sensitivity were found to be 4.23×104 l mol−1 cm−1 and 10 ng cm−2 of Vv, respectively. Linear calibration graph were obtained for 0.1–30 μg ml−1 of Vv: the stoichiometric composition of the chelate is 1:3 (V: DPCH). The reaction is instantaneous and absorbance remain stable for 48 h. The interference from over 50 cations, anions and complexing agents has been studied at 1 μg ml−1 of Vv. The method was successfully used in the determination of vanadium in several standard reference materials (alloys and steels), environmental waters (potable and polluted), biological samples (human blood and urine), soil samples, solution containing both vanadium (V) and vanadium (IV) and complex synthetic mixtures. The method has high precision and accuracy (s=±0.01 for 0.5 μg ml−1).  相似文献   

12.
A highly sensitive micelle-mediated extraction methodology for the preconcentration of trace levels of vanadium as a prior step to its determination by flame atomic absorption spectrometry (FAAS) has been developed. Vanadium was complexed with 1-(2-pyridylazo)-2-naphthol (PAN) and hydrogen peroxide in acidic medium (0.2 mol L−1 phosphoric acid) using Triton X-100 as surfactant and quantitatively extracted into a small volume of the surfactant-rich phase after centrifugation. The color reaction of vanadium ions with hydrogen peroxide and PAN in phosphoric acid medium is highly selective. The chemical variables affecting cloud point extraction (CPE) were evaluated and optimized. The R.S.D. for 5 replicate determinations at the 20 μg L−1 V level was 3.6%. The calibration graph using the preconcentration system for vanadium was linear with a correlation coefficient of 0.99 at levels near the detection limits up to at least 0.6 μg L−1. The method has good sensitivity and selectivity and was applied to the determination of trace amounts of vanadium in water samples with satisfactory result. The proposed method is a rare application of CPE-atomic spectrometry to vanadium assay, and is superior to most other similar methods, because its useful pH range is in the moderately acidic range achieved with phosphoric acid. At this pH, many potential interferents are not chelated with PAN, and iron(III) as the major interferent is bound in a stable phosphate complex.  相似文献   

13.
Jasim F 《Talanta》1969,16(6):752-756
A spectrophotometric method is described for the separation and determination of trace quantities of vanadium(IV) and (V) from uranium(VI). Vanadium is selectively separated from uranium by extraction at pH 6.5 into n-propyl 2,3,4-trihydroxybenzoate (PTB) dissolved in t-pentanol. Up to 120 microg of vanadium can be determined by measuring the absorbance of the blue complex in the organic phase at 585 nm. Uranium(VI) remains in the aqueous layer and can be determined spectrophotometrically by its reaction with PTB in aqueous acetone to produce a brown-red colour at pH 7.6-8.8. Solutions containing 25-275 microg of uranium absorb at 370-380 nm according to Beer's law. By modification, this procedure can be used for the determination of the two metals in native phosphate rocks. The effects of diverse ions on the determination of vanadium and uranium have also been examined.  相似文献   

14.
微量硫化物的测定国内外常采用亚甲基蓝法、分子荧光法、电极法、原子吸收分光光度法[1]和冷原子荧光法[2]等.汞(Ⅱ)可与四(4-三甲铵苯基)卟啉(简称TAPP)在室温下产生灵敏的显色反应(ε=2。85×105),并允许大量常见阴离子存在[3],但当S2-存在时,则极易抑制与其相当量的Hg(Ⅱ)-TAPP配合物的生成,根据这一原理,本文提出了利用,Hg(Ⅱ)-TAPP的显色反应间接分光光度法测定微量硫化物的新方法.  相似文献   

15.
Ethylisobutrazine hydrochloride is proposed as a selective and sensitive reagent for the spectrophotometric determination of vanadium(V). It forms a red-colored species with vanadium(V) in 3.5–6.5 M phosphoric acid medium. An eight-fold molar excess of reagent is necessary for the full development of the color. The red species exhibits an absorption maximum at 518 nm with a molar absorptivity of 9.75 × 103 liters mol−1 cm−1. Sandell's sensitivity is 5.2 ng cm−2. Beer's law is obeyed over the range 0.1–6.2 ppm of vanadium(V) with an optimum concentration range of 0.4–6.0 ppm. The effects of acidity, time, temperature, order of addition of reagents, reagent concentration, and the interferences from various ions, are reported. The method has been used successfully for the determination of vanadium in ilmenite and vanadium steels that contain chromium, molybdenum, manganese, nickel, copper, tungsten, and titanium.  相似文献   

16.
This work deals with the development and optimization of the sample pretreatment and consequent electrophoretic analysis of two modern plating baths containing chromium(III) and either citric acid or oxalic acid. Some model mixtures containing known amounts of components of industrial baths have been prepared to simulate simplified bath matrices. Prior to analysis, a sample pretreatment consisting of the addition of some agents that could release acid from the stable chromium complex was tested. Determination of organic anions was accomplished by indirect UV detection. The best results were achieved by precipitation of chromium(III) hydroxide. The content of oxalate and citrate in real samples was calculated as 96.5% (SD 2.3%) and 97.3% (SD 0.8%), respectively, of the declared amount. Very good robustness of the method and satisfactory repeatability of migration time and peak area were obtained. This simple inexpensive method is suitable for routine determination of citric and oxalic acid in chromium(III)‐based plating baths.  相似文献   

17.
A highly sensitive and selective catalytic adsorptive cathodic striping procedure for the determination of trace germanium is presented. The method is based on adsorptive accumulation of the Ge(IV)‐gallic acid (GA) complex onto a hanging mercury drop electrode, followed by reduction of the adsorbed species. The reduction current is enhanced catalytically by addition of vanadium(IV)‐EDTA. The optimal experimental conditions include the use of 0.03 mol/L HClO4 (pH1.6), 6.0×10?3 mol/L GA, 3.0×10?3 mol/L V(IV), 4.0×10?3 mol/L EDTA, an accumulation potential of ?0.10 V(vs. Ag/AgCl), an accumulation time of 120 s and a differential pulse potential scan mode. The peak current is proportional to the concentration of Ge(IV) over the range of 3.0×10?11 to 1.0×10?8 mol/L and the detection limit is 2×10?11 mol/L for a 120 s adsorption time. The relative standard deviation at 5.0×10?10 mol/L level is 3.1%. No serious interferences were found. The method was applied to the determination of germanium in ore, mineral water and vegetable samples with satisfactory results.  相似文献   

18.
A new simple and rapid catalytic kinetic method for the determination of trace amount of formaldehyde is described. The method is based on the catalytic effect of formaldehyde on the oxidation of Janus green by bromate in the present of sulfuric acid. The reaction monitored spectrophotometrically by measuring the decrease in absorbance of the reaction mixture at 618 nm. The fixed-time method was used for the first 150 s. For initiation of the reaction, under the optimum conditions, in the concentration range of 0.003-2.5 microg ml(-1) formaldehyde can be determined with a limit of detection 0.0015 microg ml(-1). The relative standard deviation of five replicate measurements is 2.3% for 1.0 microg ml(-1) of formaldehyde. The method was used for the determination of formaldehyde in real samples with satisfactory results.  相似文献   

19.
固相萃取-离子色谱法测定饮用水中的痕量卤代乙酸   总被引:3,自引:0,他引:3  
孙迎雪  黄建军  顾平 《色谱》2006,24(3):298-301
建立了固相萃取-离子色谱(SPE-IC)测定饮用水中痕量卤代乙酸(HAAs)(包括一氯乙酸、二氯乙酸、三氯乙酸、一溴乙酸和二溴乙酸)的方法。固相萃取采用LiChrolut EN SPE柱来进行痕量待测物的预浓缩(25倍)和基体杂质的消除,用NaOH(10 mmol/L)洗脱;色谱分离采用亲水性、高容量、氢氧化物选择型阴离子交换柱Dionex IonPac AS16(250 mm×4 mm i.d.),以NaOH为流动相进行浓度梯度淋洗,淋洗速度为0.8 mL/min,电导检测,进样量为500 μL。结果表明,用SPE-IC法测定HAAs,一溴乙酸的检测限为12.5 μg/L,其余4种HAAs的检测限为0.38~1.69 μg/L。该法可实现对饮用水中痕量卤代乙酸的测定。  相似文献   

20.
A new rapid and sensitive FI method is reported for spectrophotometric determination of trace chromium(VI) in electroplating waste water. The method is based on the reaction of Cr(VI) with sodium diphenylamine sulfonate (DPH) in acidic medium to form a purple complex (lambda(max) = 550 nm). Under the optimized conditions, the calibration curve is linear in the range 0.04-3.8 microg ml(-1) at a sampling rate of 30 h(-1). The detection limit of the method is 0.0217 microg ml(-1), and the relative standard deviation is 1.1% for eight determinations of 2 microg ml(-1) Cr(VI). The proposed method was applied to the determination of chromium in electroplating waste water with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号