首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This research found a cheap and efficient catalyst for electrooxidation of formaldehyde (HCHO). A CuO nano‐crystalline modified glassy carbon electrode (GCE) was fabricated and had an excellent electrocatalytic activity towards the oxidation of HCHO. Both the effect of potential scan rate and the effect of HCHO concentration on the electrocatalytic oxidation performance of the electrode were investigated. The amperometric current response of the electrode was proportional to HCHO concentration in the range of 1.0 µmol·L?1–10.0 mmol·L?1 with a detection limit (s/n=3) of 0.25 µmol·L?1. The electrode was stable, showing the CuO nano‐crystlline is promising for applications in fuel cells and electrochemical sensors.  相似文献   

2.
《Analytical letters》2012,45(17):3182-3194
Abstract

It is the first time that Horseradish peroxidase (HRP) was successively immobilized on the magnetic cobalt nanoparticles modified ITO (indium tin oxide) electrode. Morphologies of electrode surface were featured by the field emission‐scanning electron microscope (FSEM). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to characterize the modified process of electrode. Direct electrochemistry and electrocatalysis of HRP immobilized on nano‐Co/ITO were investigated. The biosensor exhibited high sensitivity, good stability, and excellent electrocatalytic activity to the reduction of H2O2. Under the optimized experimental conditions, a calibration curve over 2.0×10?9~2.0×10?8 mol l?1 and 2.0×10?7~2.0×10?6 mol l?1, with a limit of detection of 1.9×10?9 mol l?1 was obtained. The apparent Michaelis‐Menten constant (K M app ) for HRP/nano‐Co/ITO electrode was calculated to be 0.79 mmol l?1, indicating a higher affinity of HRP attached on the modified electrode.  相似文献   

3.
《Analytical letters》2012,45(11):1721-1734
Abstract

A novel approach to assemble an H2O2 amperometric biosensor was introduced. The biosensor was constructed by entrapping horseradish peroxidase (HRP) labeled nano‐scaled particulate gold (nano‐Au) (HRP‐nano‐Au electrostatic composite) in a new silica sol‐gel/alginate hybrid film using glassy carbon electrode as based electrode. This suggested strategy fully merged the merits of sol‐gel derived inorganic‐organic composite film and the nano‐Au intermediator. The silica sol‐gel/alginate hybrid material can improve the properties of conventional sol‐gel material and effectively prevent cracking of film. The entrapment of HRP in the form of HRP‐nano‐Au can not only factually prevent the leaking of enzyme out of the film but also provide a favorable microenvironment for HRP. With hydroquinone as an electron mediator, the proposed HRP electrode exhibited good catalytic activity for the reduction of H2O2. The parameters affecting both the qualities of sol‐gel/alginate hybrid film and the biosensor response were optimized. The biosensor exhibited high sensitivity of 0.40 Al mol?1 cm?2 for H2O2 over a wide linear range of concentration from 1.22×10?5 to 1.46×10?3 mol L?1, rapid response of <5 s and a detection limit of 0.61×10?6 mol L?1. The enzyme electrode has remarkable stability and retained 86% of its initial activity after 45 days of storage in 0.1 mol L?1 Tris‐HCl buffer solutions at pH 7.  相似文献   

4.
The highly efficient H2O2 biosensor was fabricated on the basis of the complex films of hemoglobin (Hb), nano ZnO, chitosan (CHIT) dispersed solution and nano Au immobilized on glassy carbon electrode (GCE). Biocompatible ZnO‐CHIT composition provided a suitable microenvironment to keep Hb bioactivity (Michaelis‐Menten constant of 0.075 mmol L?1). The presence of nano Au in matrix could effectively enhance electron transfer between Hb and electrode. The electrochemical behaviors and effects of solution pH values were carefully examined in this paper. The (ZnO‐CHIT)‐Au‐Hb/GCE demonstrated excellently electrocatalytical ability for H2O2. This biosensor had a fast response to H2O2 less than 4 s and excellent linear relationships were obtained in the concentration range from1.94×10?7 to 1.73×10?3 mol L?1 with the detection limit of 9.7×10?8 mol L?1 (S/N=3) under the optimum conditions. Moreover, the stability and reproducibility of this biosensor were evaluated with satisfactory results.  相似文献   

5.
《Electroanalysis》2006,18(5):471-477
The precursor film was first formed on the Au electrode surface based on the self‐assembly of L ‐cysteine and the adsorption of gold colloidal nanoparticles (nano‐Au). Layer‐by‐layer (LBL) assembly films of toluidine blue (TB) and nano‐Au were fabricated by alternately immersing the electrode with precursor film into the solution of toluidine blue and gold colloid. Cyclic voltammetry (CV) and quartz crystal microbalance (QCM) were adopted to monitor the regular growth of {TB/Au} bilayer films. The successful assembly of {TB/Au}n films brings a new strategy for electrochemical devices to construct layer‐by‐layer assembly films of nanomaterials and low molecular weight materials. In this article, {TB/Au}n films were used as model films to fabricate a mediated H2O2 biosensor based on horseradish peroxidase, which responded rapidly to H2O2 in the linear range from 1.5×10?7 mol/L to 8.6×10?3 mol/L with a detection limit of 7.0×10?8 mol/L. Morphologies of the final assembly films were characterized with scanning probe microscopy (SPM).  相似文献   

6.
唐明宇袁若  柴雅琴 《中国化学》2006,24(11):1575-1580
The third generation amperometric biosensor for the determination of hydrogen peroxide (H2O2) has been described. For the fabrication of biosensor, o-aminobenzoic acid (oABA) was first electropolymerized on the surface of platinum (Pt) electrode as an electrostatic repulsion layer to reject interferences. Horseradish peroxidase (HRP) absorbed by nano-scaled particulate gold (nano-Au) was immobilized on the electrode modified with polymerized o-aminobenzoic acid (poABA) with L-cysteine as a linker to prepare a biosensor for the detection of H2O2. Amperometric detection of H2O2 was realized at a potential of +20 mV versus SCE. The resulting biosensor exhibited fast response, excellent reproducibility and sensibility, expanded linear range and low interferences. Temperature and pH dependence and stability of the sensor were investigated. The optimal sensor gave a linear response in the range of 2.99×10^-6 to 3.55×10^-3 mol·L^-1 to H2O2 with a sensibility of 0.0177 A·L^-1·mol^-1 and a detection limit (S/N = 3) of 4.3×10^-7 mol·L^-1. The biosensor demonstrated a 95% response within less than 10 s.  相似文献   

7.
This study describes a fast and simple methodology for the preparation of Cerium (III) Hexacyanoferrate (II) (CeHCF) nanoparticles (NPs). The NPs were characterized by fourier transform infrared (FTIR), x‐ray diffraction (XRD), scanning electron microscopy (SEM) and cyclic voltammetry (CV). The CeHCF cyclic voltammogram indicate a well‐defined redox pair assigned as Fe2+/Fe3+ in the presence of cerium (III), with a formal potential of Eθ′=0.29 V (v=100 mV s?1, KNO3; 1.0 mol/L, pH 7.0). The carbon paste electrode modified with CeHCF (CeHCF‐CPE) was applied to the catalytic electrooxidation of dopamine applying Differential Pulse Voltammetry (DPV). DPV showed linear response at two concentration ranges, from 9.0×10?7 to 8.0×10?6 and 9.0×10?6 to 1.0×10?4 mol/L, with an LOD of 1.9×10?7 and 1.0×10?5 mol/L, respectively. The CeHCF‐CPE exhibited selectivity against substances commonly found in biological samples, with redox potentials close to that of dopamine, such as urea and ascorbic acid (AA). Subsequently the CeHCF‐CPE was successfully applied to the detection of dopamine in simulated urine samples, with recovery percentages ranging between 99 and 103%.  相似文献   

8.
Magnetic Fe3O4 nanoparticles functionalized multiwalled carbon nanotubes (nano‐Fe3O4 MWNTs) were prepared for electrochemical sensors. 2‐amino‐5‐mercapto‐1,3,4‐thiadiazole was used as a connecter to form a network that connected nano‐Fe3O4 MWNTs to the Au electrode surface. Modified process of the electrode was studied with SEM, TEM and cyclic voltammetry. Cyclic voltammetry and amperometric i‐t curve were used to investigate characteristics of the obtained electrode. The sensor has been successfully used on the direct detection of catechol and showed excellent performances. The linear regression equation was Ipa(μA)=0.07763+0.16739 C (μmol/L); R=0.9993 and the detection limit was 5.38×10?8 mol/L. The modified electrode showed good reproducibility and stability.  相似文献   

9.
Electrochemical behavior of dopamine (DA) was investigated at the gold nanoparticles self‐assembled glassy carbon electrode (GNP/LC/GCE), which was fabricated by self‐assembling gold nanoparticles on the surface of L ‐cysteine (LC) modified glassy carbon electrode (GCE) via successive cyclic voltammetry (CV). A pair of well‐defined redox peaks of DA on the GNP/LC/GCE was obtained at Epa=0.197 V and Epc=0.146 V, respectively. And the peak separation between DA and AA is about 0.2 V, which is enough for simultaneous determination of DA and AA. The peak currents of DA and AA were proportional with their concentrations in the range of 6.0×10?8–8.5×10?5 mol L?1 and 1.0×10?6–2.5×10?3 mol L?1, with the detection limit of 2.0×10?8 mol L?1 and 3.0×10?7 mol L?1 (S/N=3), respectively. The modified electrode exhibits an excellent reproducibility, sensibility and stability for simultaneous determination of DA and AA in human serum with satisfactory result.  相似文献   

10.
《Electroanalysis》2006,18(5):478-484
Cuprous oxide nanowhisker was prepared by using cetyltrimethyl ammonium bromide (CATB) as soft template, and was characterized by XRD and TEM methods. The electrochemical properties of nano‐Cu2O and nano‐Cu2O‐methylene blue (MB) modified electrode were studied. The experimental results indicate that nano‐Cu2O shows a couple of redox peaks corresponding to the redox of Cu(II)/Cu(I), the peak currents are linear to the scan rates which demonstrate that the electrochemical response of Cu2O is surface‐controlled. The composite nano‐Cu2O‐Nafion‐MB modified electrode shows a trend of decrease of peak currents corresponding to the Cu (II)/Cu (I). However, the electrocatalytic ability of nano‐Cu2O‐MB composite film to dopamine increases dramatically. At this composite electrode, dopamine shows a couple of quasireversible redox peaks with a peak separation of 106 mV, the peak current increases about 8 times and the oxidation peak potential decreases about 200 mV as compared to that at bare glassy carbon electrode. The peak currents change linearly with concentration of dopamine from 1×10?7 to 3.2×10?4 mol/L, the detection limit is 4.6×10?8 mol/L. The composite electrode can effectively eliminate the interference of ascorbic acid and has better stability and excellent reproducibility.  相似文献   

11.
《Electroanalysis》2005,17(11):1003-1007
A novel PVC membrane ion‐selective electrode based on tribenzyltin(IV) dithiocarbamate [Sn(IV)–TBDTB] as neutral carrier was developed for thiocyanate (SCN?) determination. The electrode exhibits a near‐Nernstian response for SCN? with a slope of 62.8±2.0 mV per decade over a wide concentration range 1.0×10?1–2.0×10?6 mol L?1 and a detection limit of 1.0×10?6 mol L?1 in MES–NaOH buffer, pH 6.0, at 25 °C. The electrode prepared with 1.5 wt.% Sn(IV)–TBDTB, 32.5 wt.% PVC and 66.0 wt.% 2‐nitrophenyloctyl ether (o‐NPOE) shows optimal response characteristics. Anti‐Hofmeister selectivity sequence for a series of anions shown by the electrode was as follows: SCN?>Sal?>I?>ClO >phCOO?>CH3COO?>Br?>Cl?>NO >NO >Citrate>SO42?. The useful pH range for the electrode was found to be 3–7 with a response time 30–40 s. The electrode has been used for direct determination of thiocyanate in wastewater with satisfactory results.  相似文献   

12.
《Electroanalysis》2004,16(9):736-740
A new enzyme‐based amperometric biosensor for hydrogen peroxide was developed relying on the efficient immobilization of horseradish peroxidase (HRP) to a nano‐scaled particulate gold (nano‐Au) film modified glassy carbon electrode (GC). The nano‐Au film was obtained by a chitosan film which was first formed on the surface of GC. The high affinity of chitosan for nano‐Au associated with its amino groups resulted in the formation of nano‐Au film on the surface of GC. The film formed served as an intermediator to retain high efficient and stable immobilization of the enzyme. H2O2 was detected using hydroquinone as an electron mediator to transfer electrons between the electrode and HRP. The HRP immobilized on nano‐Au film maintained excellent electrocatalytical activity to the reduction of H2O2. The experimental parameters such as the operating potential of the working electrode, mediator concentration and pH of background electrolyte were optimized for best analytical performance of amperometry. The linear range of detection for H2O2 is from 6.1×10?6 to 1.8×10?3 mol L?1 with a detection limit of 6.1 μmol L?1 based on signal/noise=3. The proposed HRP enzyme sensor has the features of high sensitivity (0.25 Almol?1cm?2), fast response time (t90%≤10 s) and a long‐term stability (>1 month). As an extension, glucose oxidase (GOD) was chemically bound to HRP‐modified electrode. A GOD/HRP bienzyme‐modified electrode formed in this way can be applied to the determination of glucose with satisfactory performance.  相似文献   

13.
A surface‐renewable tris(1, 10‐phenanthroline‐5, 6‐dione) iron (D) hexafluorophosphate (FePD) modified carbon ceramic electrode was constructed by dispersing FePD and graphite powder in methyltrimethoxysilane (MTMOS) based gels. The FePD‐modified electrode presented pH‐dependent voltammetric behavior, and its peak currents were diffusion‐controlled in 0.1 mol/L Na2SO4 + H2SO4 solution (pH = 0.4). In the presence of iodate, dear electrocatalytic reduction waves were observed and thus the chemically modified electrode was used as an amperometric sensor for iodate in common salt. The linear range, sensitivity, detection limit and response time of the iodate sensor were 5 × 10?6–1 × 10?2 mol/L, 7.448 μA·L/ mmol, 1.2 × 10?6 mol/L and 5 s, respectively. A distinct advantage of this sensor is its good reproducibility of surface‐renewal by simple mechanical polishing.  相似文献   

14.
The fabrication and application of a novel electrochemical detector (ED) with nano crystalline Mn-doped lead dioxide film chemically modified electrode (CME) for liquid chromatography (LC) were described. The Mn-doped PbO2 film was characterized by scanning tunnel microscope. The electrochemical behaviors of tetrahydrobiopterin, monoamine neurotransmitters and their metabolites at the CME were investigated by cyclic voltammetry and differential pulse voltammetry. It was found that the CME exhibited efficiently electrocatalytic effect on the current response of the seven analytes and the linear ranges of them were over three orders of magnitude with the detection limits being 5.0 × 10?10 mol L?1 for tetrahydrobiopterin, 2.5 × 10?10 mol L?1 for dopamine, 2.0 × 10?10 mol L?1 for norepinephrine, 5.0 × 10?10 mol L?1 for serotonin, 4.0 × 10?10 mol L?1 for 3,4-dihydroxyphenylacetic acid, 2.0 × 10?9 mol L?1 for homovanillic acid, 1.0 × 10?9 mol L?1 for 5-hydroxyindoleacetic acid. For its stability, sensitivity, convenience in preparing and long-life of activity, the Mn-doped PbO2 electrode is therefore suitable for determination of real samples. Coupled with microdialysis sampling, the application of this method for the analysis of tetrahydrobiopterin, monoamine neurotransmitters and their metablites in rat brain was satisfactory.  相似文献   

15.
Electrochemical behavior of baicalin (BA) at an electrochemically activated glassy carbon electrode (GCE) had been investigated in Britton‐Robinson (B‐R) buffer solution (pH = 2.87) by cyclic voltammetry (CV) and square wave voltammetry (SWV). The experimental results suggested that the electrode exhibited an electrocatalytic activity toward the redox of BA. The electron transfer coefficient (α) and the standard rate constant (ks) of BA at the electrochemically activated glassy carbon electrode were calculated. The reaction mechanism was proposed and discussed in this work. Under the selected conditions, the reduction peak current was linearly dependent on the concentration of BA in the range of 5.0 × 10?8 to 3.0 × 10?6 mol L?1 (r = 0.9990), with a detection limit of 2.0 × 10?8 mol L?1. The relative standard deviation (R.S.D.) for five times successful determination of 1.0 × 10?6 mol L?1 baicalin were 2.9%. The proposed method was also successfully applied for the determination of BA in human blood serum.  相似文献   

16.
A novel nanocomposite designed by the assembly of the positively charged poly(diallyldimethylammonium chloride) protected gold nanoparticles (PDDA‐GNPs), and the negatively charged multi‐walled carbon nanotubes (MWCNTs) on ITO electrode via electrostatic interaction, was used as a supporting matrix for immobilizing hemoglobin (Hb) to develop a high‐performance hydrogen peroxide (H2O2) biosensor. The cyclic voltammetrys of immobilized Hb showed a pair of well‐defined and quasi‐reversible redox peaks with the formal potential of ‐0.205V (vs. SCE) and the peak‐to‐peak potential separation of 44 mV at a scan rate of 100 mV×s?1 in 0.1 mol×L?1 pH 7.0 PBS. Under the optimized experimental conditions, a linearity range for determination of H2O2 was from 2.0 × 10?6 to 5.2 × 10?4 mol×L?1 with a correlation coefficient of 0.9994 (n = 37) and a detection limit of 8.4 × 10?7 mol×L?1. The biosensor displayed excellent electrochemical and electrocatalytic response to the reduction of H2O2, high sensitivity, long‐term stability, good bioactivity and selectivity.  相似文献   

17.
In this paper, a pre‐anodized inlaying ultrathin carbon paste electrode (PAIUCPE) with 316L as a matrix was constructed by a simple and fast electrochemical pretreatment. Using xanthine (Xa) and hypoxanthine (HXa) as the target compounds, the pH effects compositions of buffer solution, the accumulation times, hydrogen bond catalysis, degree of auxiliary electrode reaction on the size of peak currents (Ip) of Xa and HXa was discussed in detail. Also, it was proposed that Xa and HXa were respectively absorbed at the surface of PAIUCPE through hydrogen bonding. The influencing mechanisms of the PAIUCEP on electrochemical oxidation of Xa and HXa were explained in detail. Moreover, the linear relationships for the Xa and HXa were obtained in the range of 6×10?8–3×10?5 mol/L and 2×10?7–7×10?5 mol/L, respectively. The detection limits for the Xa and HXa were 1.2×10?8 mol/L and 5.7×10?8 mol/L, respectively. Moreover, this proposed method could be applied to determine the Xa and HXa in human urine simultaneously with satisfactory results.  相似文献   

18.
《Electroanalysis》2006,18(17):1722-1726
The electrochemical properties of L ‐cysteic acid studied at the surface of p‐bromanil (tetrabromo‐p‐benzoquinone) modified carbon paste electrode (BMCPE) in aqueous media by cyclic voltammetry (CV) and double step potential chronoamperometry. It has been found that under optimum condition (pH 7.00) in cyclic voltammetry, the oxidation of L ‐cysteic acid at the surface of BMCPE occurs at a half‐wave potential of p‐bromanil redox system (e.g., 100 mV vs. Ag|AgCl|KClsat), whereas, L ‐cysteic acid was electroinactive in the testing potential ranges at the surface of bare carbon paste electrode. The apparent diffusion coefficient of spiked p‐bromanil in paraffin oil was also determined by using the Cottrell equation. The electrocatalytic oxidation peak current of L ‐cysteic acid exhibits a linear dependency to its concentration in the ranges of 8.00×10?6 M–6.00×10?3 M and 5.2×10?7 M–1.0×10?5 M using CV and differential pulse voltammetry (DPV) methods, respectively. The detection limits (2σ) were determined as 5.00×10?6 M and 4.00×10?7 M by CV and DPV methods. This method was used as a new, selective, rapid, simple, precise and suitable voltammetric method for determination of L ‐cysteic acid in serum of patient's blood with migraine disease.  相似文献   

19.
于浩  郑建斌 《中国化学》2007,25(4):503-509
A copper hexacyanoferrate modified ceramic carbon electrode (CuHCF/CCE) had been prepared by two-step sol-gel technique and characterized using electrochemical methods. The resulting modified electrode showed a pair of well-defined surface waves in the potential range of 0.40 to 1.0 V with the formal potential of 0.682 V (vs. SCE) in 0.050 mol·dm^-3 HOAc-NaOAc buffer containing 0.30 mol·dm^-3 KCl. The charge transfer coefficient (a) and charge transfer rate constant (ks) for the modified electrode were calculated. The electrocatalytic activity of this modified electrode to hydrazine was also investigated, and chronoamperometry was exploited to conveniently determine the diffusion coefficient (D) of hydrazine in solution and the catalytic rate constant (kcat). Finally, hydrazine was determined with amperometry using the resulting modified electrode. The calibration plot for hydrazine determination was linear in 3.0 × 10^-6--7.5 × 10^-4 mol·dm^-3 with the detection limit of 8.0 × 10^-7 molodm^-3. This modified electrode had some advantages over the modified film electrodes constructed by the conventional methods, such as renewable surface, good long-term stability, excellent catalytic activity and short response time to hydrazine.  相似文献   

20.
XU  Jiming  HAN  Wenxia  YIN  Qifan  SONG  Jie  ZHONG  Hui 《中国化学》2009,27(11):2197-2202
The direct electrochemistry of glucose oxidase (GOD) was achieved based on the immobilization of GOD on a natural nano‐structural attapulgite (ATP) clay film modified glassy carbon (GC) electrode. The immobilized GOD displayed a pair of well‐defined quasi‐reversible redox peaks with a formal potential (E0′) of ?457.5 mV (vs. SCE) in 0.1 mol·L?1 pH 7.0 phosphate buffer solution. The peak current was linearly dependent on the scan rate, indicating that the direct electrochemistry of GOD in that case was a surface‐controlled process. The immobilized glucose oxidase could retain bioactivity and catalyze the oxidation of glucose in the presence of ferrocene monocarboxylic acid (FMCA) as a mediator with the apparent Michaelis‐Menten constant Kappm of 1.16 mmol·L?1. The electrocatalytic response showed a linear dependence on the glucose concentration ranging widely from 5.0×10?6 to 6.0×10?4 mol·L?1 (with correlation coefficient of 0.9960). This work demonstrated that the nano‐structural attapulgite clay was a good candidate material for the direct electrochemistry of the redox‐active enzyme and the construction of the related enzyme biosensors. The proposed biosensors were applied to determine the glucose in blood and urine samples with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号