首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
A living cell has numerous proteins, only a few thousand of which have been identified to date. Cell-free protein synthesis is a useful and promising technique to discover and produce various proteins that might be beneficial for biotechnological, pharmaceutical, and medical applications. For this study, we evaluated the performance and the general applicability of our previously developed microreactor array chip to cell-free protein synthesis by comparisons with a commercially available system. The microreactor array chip comprises a temperature control chip made of glass and a disposable reaction chamber chip made of polydimethylsiloxane (PDMS). For evaluation of the microreactor array chip, rat adipose-type fatty acid binding protein, glyceraldehyde-3-phosphate dehydrogenase, cyclophilin, and firefly luciferase were synthesized from their respective DNA templates using a cell-free extract prepared from Escherichia coli. All these proteins were synthesized in the microreactor array chip, and their respective amounts and yields were investigated quantitatively.  相似文献   

2.
This paper introduces a new substrate for reverse-phase protein microarray applications based on macroporous silicon. A key feature of the microarray substrate is the vastly surface enlarging properties of the porous silicon, which simultaneously offers highly confined microarray spots. The proof of principle of the reverse array concept was demonstrated in the detection of different levels of cyclin E, a possible cancer biomarker candidate which regulates G1-S transition and correlates with poor prognosis in different types of human cancers. The substrate properties were studied performing analysis of total cyclin E expression in human colon cancer cell lines Hct116 and SW480. The absence of unspecific binding and good microarray quality was demonstrated. In order to verify the performance of the 3-D textured macroporous surface for complex biological samples, lysates of the human tissue spiked to different levels with cell extract overproducing cyclin E (Hct116) were arrayed on the chip surface. The samples were spotted in a noncontact mode in 100 pL droplets with spots sizes ranged between 50 and 70 mum and spot-to-spot center distances 100 mum, allowing microarray spot densities up to 14 000 spots per cm(2). The different sample types of increasing complexities did not have any impact on the spot intensities recorded and the protein spots showed good homogeneity and reproducibility over the recorded microarrays. The data demonstrate the potential use of macroporous silicon as a substrate for quantitative determination of a cancer biomarker cyclin E in tissue lysates.  相似文献   

3.
Zhang S  Van Pelt CK  Henion JD 《Electrophoresis》2003,24(21):3620-3632
We report a method using a fully automated chip-based nanoelectrospray system for two-dimensional (2-D) gel sample analyses with mass spectrometric detection. The automated nanoelectrospray system, consisting of the NanoMate and electrospray ionization (ESI) chip, serves as both an autosampler and nanoESI source. This infusion system aspirates samples from a 96-well plate using disposable pipette tips and then delivers these samples sequentially to an ESI chip. This chip is a fully integrated monolithic device consisting of a 10x10 array of nozzles. The automated nanoelectrospray system is easily controlled through software, permitting the user to select the number of samples to be analyzed, the volume of sample to aspirate, the spray voltage, and analysis time. The system offers all the advantages of conventional nanoelectrospray plus automated, high-throughput analyses without analyte carryover. The system was used for a protein identification study of 2-D gel spots of both Escherichia coli and yeast crude cell extracts. The identification of 50 spots from E. coli crude cell extract and 27 spots from yeast extract is presented, demonstrating the powerful combination of the automated nanoESI system, the Thermo Finnigan LCQ Deca ion-trap mass spectrometer, and SEQUEST search software. In addition, the effects of silver staining and colloidal Coomassie blue staining of 2-D gel spots on the detection sensitivity and protein sequence coverage are compared and discussed. Furthermore, the comparison results using the multiwell microscale preparation kit versus manual extraction for in-gel samples are presented.  相似文献   

4.
In this study, in situ surface‐enhanced Raman scattering (SERS) decoding was demonstrated in microfluidic chips using novel thin micro gold shells modified with Raman tags. The micro gold shells were fabricated using electroless gold plating on PMMA beads with diameter of 15 μm. These shells were sophisticatedly optimized to produce the maximum SERS intensity, which minimized the exposure time for quick and safe decoding. The shell surfaces produced well‐defined SERS spectra even at an extremely short exposure time, 1 ms, for a single micro gold shell combined with Raman tags such as 2‐naphthalenethiol and benzenethiol. The consecutive SERS spectra from a variety of combinations of Raman tags were successfully acquired from the micro gold shells moving in 25 μm deep and 75 μm wide channels on a glass microfluidic chip. The proposed functionalized micro gold shells exhibited the potential of an on‐chip microfluidic SERS decoding strategy for micro suspension array.  相似文献   

5.
A novel cytokine assay has been designed using a cellular chip by combining a collagen gel embedded cell culture technique with scanning electrochemical microscopy-enzyme linked immunosorbent assay (SECM-ELISA). An array of cell-collagen gel mixture (2 μL) was spotted on an antibody-coated chip and incubated for 0.5-24 h. The very small trace amounts of cytokines produced by the activated leukocytes on the chip were effectively entrapped within the collagen gel matrix, and these were collected with the immobilized antibodies on the chip. The chip was further treated with horseradish peroxidase (HRP)-labeled antibodies via the sandwich method after removing the cell-collagen gel spots from the chip. Scanning electrochemical microscopy (SECM) was used to quantitatively evaluate the cytokines from the activated leukocytes produced on the chip, and the SECM images were obtained to visualize the position and concentration of IL-1β secreted from THP-1 and HL-60 cell lines at concentration levels of 10-350 pg mL−1. Based on the chemiluminescence method, the sensitivity of the cytokine assay system in combination with SECM-ELISA is comparable to that of the marketed cytokine assay kit; further, the sample volume required for a single assay is drastically reduced.  相似文献   

6.
The simultaneous detection of multiple analytes is an important consideration for the advancement of biosensor technology. Currently, few sensor systems possess the capability to accurately and precisely detect multiple antigens. This work presents a simple approach for the functionalization of sensor surfaces suitable for multichannel detection. This approach utilizes self-assembled monolayer (SAM) chemistry to create a nonfouling, functional sensor platform based on biotinylated single-stranded DNA immobilized via a streptavidin bridge to a mixed SAM of biotinylated alkanethiol and oligo(ethylene glycol). Nonspecific binding is minimized with the nonfouling background of the sensor surface. A usable protein chip is generated by applying protein-DNA conjugates which are directed to specific sites on the sensor chip surface by utilizing the specificity of DNA hybridization. The described platform is demonstrated in a custom-built surface plasmon resonance biosensor. The detection capabilities of a sensor using this protein array have been characterized using human chorionic gonadotropin (hCG). The platform shows a higher sensitivity in detection of hCG than that observed using biotinylated antibodies. Results also show excellent specificity in protein immobilization to the proper locations in the array. The vast number of possible DNA sequences combine with the selectivity of base-pairing makes this platform an excellent candidate for a sensor capable of multichannel protein detection.  相似文献   

7.
A microreactor array was developed which enables high-throughput cell-free protein synthesis. The microreactor array is composed of a temperature control chip and a reaction chamber chip. The temperature control chip is a glass-made chip on which temperature control devices, heaters and temperature sensors, are fabricated with an ITO (indium tin oxide) resistive material. The reaction chamber chip is fabricated by micromolding of PDMS (polydimethylsiloxane), and is designed to have an array of reaction chambers and flow channels for liquid introduction. The microreactor array is assembled by placing the reaction chamber chip on the temperature control chip. The small thermal mass of the reaction chamber resulted in a short thermal time constant of 170 ms for heating and 3 s for cooling. The performance of the microreactor array was examined through the experiments of cell-free protein synthesis. By measuring the fluorescence emission from the products, it was confirmed that GFP (Green Fluorescent Protein) and BFP (Blue Fluorescent Protein) were successfully synthesized using Escherichia coli extract.  相似文献   

8.
A protein array chip for label-free optical detection of low molecular weight compounds has been developed. As a proof of principle, the chip is proven capable of rapidly (approximately 1 min) determining hits from aqueous cocktails composed of four common narcotics, cocaine, ecstasy, heroin, and amphetamine, using imaging surface plasmon resonance (SPR) as the detection principle. The chip is produced by injecting a mixture of antibodies and letting them self-sort and bind to narcotic analog coupled proteins already present in a predefined pattern on the supporting substrate. An indirect detection method, where antibodies are displaced from the surface upon recognition of their corresponding narcotics, is used to obtain the optical contrast and thus a detectable SPR and/or ellipsometric signal. Two types of readouts are possible from the present setup: intensity SPR images and SPR/ellipsometric sensorgrams. Positive hits were routinely obtained for analyte concentrations of 50 pg/μL and the limit of detection, without any parameter optimizations, seems to fall in the range 0.5 pg/μL (1.4 nM) for heroin, 2.5 pg/μL (8.2 nM) for cocaine, and 5 pg/μL for the other two narcotics (26 nM for ecstasy and 37 nM for amphetamine). With improved readout possibilities (sampling frequency), signal evaluation algorithms, and antibody–antigen design strategies, we believe this limit can be further improved. The chip is shown to work for many measurement cycles with excellent reproducibility. Moreover, with a more advanced fluidic system, excess injected antibodies could be collected and reused for many cycles, which could make the running costs of the system very low. The chip is in no way limited to detection of narcotics. Other low molecular weight compounds could easily be detected on the same chip. For example, trinitrotoluene detection has already been demonstrated using our chip. Possible areas of application for the system are therefore envisaged in airport and underground transport security, customs, drug interdiction, forensics, and as warning alerts on military equipment and personnel. Figure Narcotics chip (left) composed of spots of piezodispensed analog-coupled proteins that are loaded with antibodies to form a patterned regions represented by the capital letter of the four different narcotics in focus. (Right) The same chip showing hits for ectasy and herion in the cocktail. Both images are obtained in imaging surface plasmon resonance mode  相似文献   

9.
The use of probe beads for lab-on-chip affinity assays is very interesting from a practical point of view. It is easier to handle and trap beads than molecules in microfluidic systems. We present a method for the immobilization of probe beads at defined areas on a chip using dielectrophoresis (DEP)-controlled adhesion. The method is fast, i.e., it takes between 10 and 120 s--depending on the protocol--to functionalize a chip surface at defined areas. The method is versatile, i.e., it works for beads with different types of probe molecule coatings. The immobilization is irreversible, i.e., the retained beads are able to withstand high flow velocities in a flow-through device even after the DEP voltage is turned off, thus allowing the use of conventional high-conductivity analyte buffers in the following assay procedure. We demonstrate the on-chip immobilization of fluorescent beads coated with biotin, protein A, and goat-antimouse immunoglobulin G (IgG). The number of immobilized beads at an electrode array can be determined from their fluorescence signal. Further, we use this method to demonstrate the detection of streptavidin and mouse IgG. Finally, we demonstrate the feasibility of the parallel detection of different analyte molecules on the same chip.  相似文献   

10.
Fluorescent sensor array in a microfluidic chip   总被引:1,自引:0,他引:1  
Miniaturization and automation are highly important issues for the development of high-throughput processes. The area of micro total analysis systems (muTAS) is growing rapidly and the design of new schemes which are suitable for miniaturized analytical devices is of great importance. In this paper we report the immobilization of self-assembled monolayers (SAMs) with metal ion sensing properties, on the walls of glass microchannels. The parallel combinatorial synthesis of sensing SAMs in individually addressable microchannels towards the generation of optical sensor arrays and sensing chips has been developed. [figure: see text] The advantages of microfluidic devices, surface chemistry, parallel synthesis, and combinatorial approaches have been merged to integrate a fluorescent chemical sensor array in a microfluidic chip. Specifically, five different fluorescent self-assembled monolayers have been created on the internal walls of glass microchannels confined in a microfluidic chip.  相似文献   

11.
We have developed a method for the quantitative 3-dimensional profiling of micron sized channel networks within optically transparent "lab-on-a-chip" microreactor devices. The method involves capturing digitised microscope images of the channel network filled with an optically absorbing dye. The microscope is operated in transmission mode using light filtered through a narrow bandpass filter with a maximum transmission wavelength matching the wavelength of the absorbance maximum of the dye solution. Digitised images of a chip filled with solvent and dye solution are analysed pixel by pixel to yield a spatially resolved array of absorbance values. This array is then converted to optical path length values using the Beer-Lambert law, thereby providing the 3D profile of the channel network. The method is capable of measuring channel depths from 10 to 500 microm (and probably even smaller depths) with an accuracy of a few percent. Lateral spatial resolution of less than 1 microm is achievable. It has been established that distortion of the measured profiles resulting from a mismatch in refractive index between the dye solution and the glass of the microreactors is insignificant. The method has been successfully used here to investigate the effects of thermal bonding and etch time on channel profiles. The technique provides a convenient, accurate and non-destructive method required to determine channel profiles; information which is essential to enable optimisation of the operating characteristics of microreactor devices for particular applications.  相似文献   

12.
研制一种基于金叉指微电极阵列(IDA)的电流型硝酸根离子(NO-3)微传感电极芯片.基于微机电系统(Micro-Electro-Mechanical Systems,MEMS)工艺制备金IDA微电极,通过电化学沉积技术在IDA微电极表面修饰三维枝状结构纳米银敏感膜,利用敏感膜对硝酸根离子良好的电催化还原性能,采用脉冲方波伏安(SWV)电化学测量方法,实现对硝酸根离子在25~1000μmol/L浓度范围内的快速检测,灵敏度达9.5 nA/(μmol/L),线性度为99.98%,检测下限为10μmol/L.考察水体中常见的NO-2,F-,3PO 4-,SO 42-,2CO3-,NH+4,Na+和K+等离子对该传感芯片的干扰性能,传感芯片表现出较好的抗干扰性能.制备的三维枝状结构纳米银修饰IDA微电极可实现水环境(pH 5.0~9.0)中NO-3的电化学检测,对应用于自然水环境中硝酸根离子的现场检测具有积极意义.  相似文献   

13.
The application of silicon mold inserts by micro‐hot embossing molding has been explored in microfluidic chip fabrication. For the mold insert, this study employed an SU‐8 photoresist to coat the silicon wafer. Ultraviolet light was then used to expose the pattern on the SU‐8 photoresist surface. This study replicates the microstructure of the silicon mold insert by micro‐hot embossing molding. Different processing parameters (embossing temperature, embossing pressure, embossing time, and de‐molding temperature) for the cycle‐olefin polymer (COP) film of microfluidic chips are evaluated. The results showed that the most important parameter for replication of molded microfluidic chip is embossing temperature. De‐molding temperature is the most important parameter for surface roughness of the molded microfluidic chip. The microchannel is bonded with a cover by thermal bonding processing to form the sealed microfluidic chip. The bonding temperature is the most important factor in the bonding strength of the sealed microfluidic chip. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
Klett O  Nischang I  Nyholm L 《Electrophoresis》2002,23(21):3678-3682
Samples containing microM concentrations of dopamine, (+/-)-isoproterenol, para-aminophenol and chlorogenic acid have been separated by capillary electrophoresis (CE) and detected using end-column amperometric detection based on a novel decoupling method. The present decoupling approach involves the use of an electrochemical detector chip containing an array of microband electrodes where the working and reference electrodes are positioned only 10 microm from each other. The short distance between the working and reference electrodes ensures that both electrodes are very similarly affected by the presence of the CE electric field. With this method, no shift in the detection potential was seen when the CE high voltage was applied. This eliminated the need for a reoptimization of the detection potential to compensate for the influence of the separation voltage on the detection. It is also demonstrated that catecholamines can be detected using gold microband electrodes by careful adjustment of the detection potential to avoid the formation of gold oxide. Such careful adjustments of the detection potential are straightforward using the present decoupling method.  相似文献   

15.
Wang C  Ouyang J  Ye DK  Xu JJ  Chen HY  Xia XH 《Lab on a chip》2012,12(15):2664-2671
Fluorescence analysis has proved to be a powerful detection technique for achieving single molecule analysis. However, it usually requires the labeling of targets with bright fluorescent tags since most chemicals and biomolecules lack fluorescence. Conventional fluorescence labeling methods require a considerable quantity of biomolecule samples, long reaction times and extensive chromatographic purification procedures. Herein, a micro/nanofluidics device integrating a nanochannel in a microfluidics chip has been designed and fabricated, which achieves rapid protein concentration, fluorescence labeling, and efficient purification of product in a miniaturized and continuous manner. As a demonstration, labeling of the proteins bovine serum albumin (BSA) and IgG with fluorescein isothiocyanate (FITC) is presented. Compared to conventional methods, the present micro/nanofluidics device performs about 10(4)-10(6) times faster BSA labeling with 1.6 times higher yields due to the efficient nanoconfinement effect, improved mass, and heat transfer in the chip device. The results demonstrate that the present micro/nanofluidics device promises rapid and facile fluorescence labeling of small amount of reagents such as proteins, nucleic acids and other biomolecules with high efficiency.  相似文献   

16.
Microcontact printing (µCP) has been used to introduce temporary hydrophobic barriers on carboxymethylated dextran (CMD) hydrogels on gold. Among the investigated types of inks, tetraoctadecylammonium bromide (TOAB), electrostatically bound to the CMD layer, provided the most well-defined features both with respect to pattern-definition and reversibility upon exposure to a regeneration solution. The printed patterns were characterized by atomic force microscopy (AFM), scanning electron microscopy (SEM), microscopic wetting and imaging null ellipsometry to explore the influence of concentration of ink solution and contact time on the appearance of the printed layer. AFM revealed that the printed TOAB molecules aggregated into clusters rather than into a homogeneous mono- or multilayer on the CMD hydrogel. It was also observed that printed areas of TOAB that are larger than 25µm are inhomogeneous most likely because of an edge transfer lithography (ETL) mechanism. A protein model system based on Protein A-rabbit antimouse Fc was used to evaluate the potential of the patterned surface as a protein microarray chip by means of surface plasmon microscopy (SPM). Moreover, non-specific adsorption of several proteins onto TOAB barriers was also studied using surface plasmon resonance (SPR), and it is evident that undesired adsorption can be eliminated by removing barriers after ligand immobilization, but prior to analyte exposure, by treating the patterned surface with a simple salt regeneration solution.  相似文献   

17.
A disposable single use polymer microfluidics chip has been developed and manufactured by micro injection molding. The chip has the same outer dimensions as a standard microscope slide (25 x 76 x 1.1 mm) and is designed to be compatible with existing microscope slide handling equipment like microarray scanners. The chip contains an inlet, a 10 microL hybridization chamber capable of holding a 1000 spot array, a waste chamber and a vent to allow air to escape when sample is injected. The hybridization chamber ensures highly homogeneous hybridization conditions across the microarray. We describe the use of this chip in a flexible setup with fluorescence based detection, temperature control and liquid handling by computer controlled syringe pumps. The chip and the setup presented in this article provide a powerful tool for highly parallel studies of kinetics and thermodynamics of duplex formation in DNA microarrays. The experimental setup presented in this article enables the on-chip microarray to be hybridized and monitored at several different stringency conditions during a single assay. The performance of the chip and the setup is demonstrated by on-line measurements of a hybridization of a DNA target solution to a microarray. A presented numerical model indicates that the hybridization process in microfluidic hybridization assays is diffusion limited, due to the low values of the diffusion coefficients D of the DNA and RNA molecules involved.  相似文献   

18.
A majority of all biologically active proteins are glycosylated and various diseases have proven to correlate with alterations in protein glycosylation. Sensitive identification of different glycoprotein glycoforms is therefore of great diagnostic value. Here we describe a method with potential for glycoprotein profiling, based on lectins as capture probes immobilized on particulate substrates in the nm-range. The nanoparticles present high concentrations of attachment sites for specific ligands and cause minimal steric hindrance to binding. In the present model study the mannose-binding lectin ConA has been coupled to polystyrene nanoparticles via a poly(ethyleneoxide) linker which protects the protein conformation and activity and prevents unspecific protein adsorption. The ConA-coated particles are accommodated at different spots on the analytical surface via oligonucleotide linkage. This attachment, which relies on the hybridization of complementary oligonucleotides, allows firm fixation of the particles at specific positions. The ConA attached to the particles has retained conformation and activity and binds selectively to a series of different glycoproteins. The results indicate the potential for using a multi-lectin nanoparticle array in glycoprotein mapping.  相似文献   

19.
A fluorimetric micro spot array using non-specific recognition function is described for the analysis of liquid samples. The array was composed of binary mixtures of various fluorescence dyes which were embedded in a hydrogel matrix. The interactions between the fluorescent dyes and their molecular surrounding inside the hydrogel, influence their fluorescence wave length and intensities. The array was used for the characterization of solvent mixtures. Developed fluorescence patterns of the complete array as well as the fluorescence intensity changes of single spots were analysed. It was proven, that specific analytical information can be gained using this non-specific recognition approach. The identification of some alcoholic beverages is described as an example of the application of this method when used for quality control purposes. Analogous to the appellation “electronic nose” and “electronic tongue” the described micro spot array acts as an “optochemical tongue”.  相似文献   

20.
The last decade has witnessed a significant increase in interest in whole-cell biosensors for diverse applications, as well as a rapid and continuous expansion of array technologies. The combination of these two disciplines has yielded the notion of whole-cell array biosensors. We present a potential manifestation of this idea by describing the printing of a whole-cell bacterial bioreporters array. Exploiting natural bacterial tendency to adhere to positively charged abiotic surfaces, we describe immobilization and patterning of bacterial "spots" in the nanolitre volume range by a non-contact robotic printer. We show that the printed Escherichia coli-based sensor bacteria are immobilized on the surface, and retain their viability and biosensing activity for at least 2 months when kept at 4 °C. Immobilization efficiency was improved by manipulating the bacterial genetics (overproducing curli protein), the growth and the printing media (osmotic stress and osmoprotectants) and by a chemical modification of the inanimate surface (self-assembled layers of 3-aminopropyl-triethoxysilane). We suggest that the methodology presented herein may be applicable to the manufacturing of whole-cell sensor arrays for diverse high throughput applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号