首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ohura H  Imato T  Yamasaki S 《Talanta》1999,49(5):1383-1015
A rapid potentiometric flow injection technique for the simultaneous determination of oxychlorine species such as ClO3–ClO2 and ClO3–HClO has been developed, using both a redox electrode detector and a Fe(III)–Fe(II) potential buffer solution containing chloride. The analytical method is based on the detection of a large transient potential change of the redox electrode due to chlorine generated via the reaction of the oxychlorine species with chloride in the potential buffer solution. The sensitivities to HClO and ClO2 obtained by the transient potential change were enhanced 700–800-fold over that using an equilibrium potential. The detection limit of the present method for HClO and ClO2 is as low as 5×10−8 M with use of a 5×10−4 M Fe(III)–1×10−3 M Fe(II) buffer containing 0.3 M KCl and 0.5 M H2SO4. On the other hand, sensitivity to ClO3 was low when a potential buffer solution containing 0.5 M H2SO4 was used, but could be increased largely by increasing the acidity of the potential buffer. The detection limit for ClO3 was 2×10−6 M with the use of a 5×10−4 M Fe(III)–1×10−3 M Fe(II) buffer containing 0.3 M KCl and 9 M H2SO4. By utilizing the difference in reactivity of oxychlorine species with chloride in the potential buffer, a simultaneous determination method for a mixed solution of ClO3–ClO2 or ClO3–HClO was designed to detect, in a timely manner, a transient potential change with the use of two streams of potential buffers which contain different concentrations of sulfuric acid. Analytical concentration ranges of oxychlorine species were 2×10−5–2×10−4 M for ClO3, and 1×10−6–1×10−5 M for HClO and ClO2. The reproducibility of the present method was in the range 1.5–2.3%. The reaction mechanism for the transient potential change used in the present method is also discussed, based on the results of batchwise experiments. The simultaneous determination method was applied to the determination of oxychlorine species in a tap water sample, and was found to provide an analytical result for HClO, which was in good agreement with that obtained by the o-tolidine method and to provide a good recovery for ClO3 added to the sample.  相似文献   

2.
Wang Z  Zhang H  Zhou S  Dong W 《Talanta》2001,53(6):1133-1138
A novel method is described for determination of metoclopramide (MCP) by second-derivative adsorptive anodic stripping voltammetry with a nafion-modified electrode. The stripping peak current is proportional to the concentration of MCP over the range 1.2×10−9–4.6×10−7 M. The detection limit is 8.0×10−11 M with 4-min accumulation. The method has been successfully applied to the determination of MCP in human serum.  相似文献   

3.
A PVC membrane electrode based on bis-2-thiophenal propanediamine (TPDA) coated directly on graphite is described. The electrode exhibits a Nernstian response for Cu2+ over a very wide concentration range (1.0×10−1 to 6.0×10−8 M) with a detection limit of 3.0×10−8 M (2.56 ng ml−1). It has a fast response time and can be used for at least 2 months without any major deviation. The proposed sensor revealed very good selectivities for Cu2+ over a wide variety of other metal ions and could be used in the pH range of 3.0–7.0. It was successfully used for direct determination of copper in black tea and as an indicator electrode in potentiometric titration of copper ion.  相似文献   

4.
Pei J  Li XY 《Talanta》2000,51(6):2379-1115
A thin film of mixed-valent CuPtCl6 is deposited on a glassy carbon electrode by continuous cyclic scanning in a solution containing 3×10−3 M CuCl2+3×10−3 M K2PtCl6+1 M KCl in the potential range from 700 to −800 mV. The cyclic voltammetry is used to study the electrochemical behaviors of nitrite on CuPtCl6/GC modified electrode and the electrode displays a good catalytic activity toward the oxidation of nitrite. The effects of the film thickness, pH, the electrode stability and precision have been evaluated. Experiments in flow-injection analysis are performed to characterize the electrode as an amperometric sensor for the detection of nitrite. The modified electrode shows a wide dynamic range, quite a low detection limit and short response time. The linear relationship between the flow-injection peak currents and the concentrations of nitrite is at a range of 1×10−7–2×10−3 M with a detection limit of 5×10−8 M.  相似文献   

5.
A new modified carbon paste electrode (CPE) based on a recently synthesized Schiff base complex of Fe(III) as a suitable carrier for I ion is described. The electrode exhibits a super Nernstian slope of 71.0±0.3 mV per decade for I ion over a wide concentration range from 1.0×10−6 to 5.0×10−1 M, with a low detection limit of 6.5×10−7 M. It has a relatively fast response time, a satisfactory reproducibility and relatively long life time. The proposed sensor shows a fairly good selectivity toward I ion in comparison to other common anions. The potentiometric response is independent of the pH of the test solution in the pH range 3.5–10.0. Spectrophotometric studies confirmed the redox-type response mechanism of the electrode toward iodide ion. The proposed electrode was used as an indicator electrode in potentiometric titration of iodide ion.  相似文献   

6.
Wang Q  Li N 《Talanta》2001,55(6):243-1225
The thiolactic acid (TLA) self-assembled monolayer modified gold electrode (TLA/Au) is demonstrated to catalyze the electrochemical response of norepinephrine (NE) by cyclic voltammetry. A pair of well-defined redox waves were obtained and the calculated standard rate constant (ks) is 5.11×10−3 cm s−1 at the self-assembled electrode. The electrode reaction is a pseudo-reversible process. The peak current and the concentration of NE are a linear relationship in the range of 4.0×10−5–2.0×10−3 mol l−1. The detection limit is 2.0×10−6 mol l−1. By ac impedance spectroscopy the apparent electron transfer rate constant (kapp) of Fe(CN)3−/Fe(CN)4− at the TLA/Au electrode was obtained as 2.5×10−5 cm s−1.  相似文献   

7.
Three different mixed aza-thioether crowns containing a 1,10-phenanthroline sub-unit were investigated to characterize their abilities as copper(II) ion carriers in PVC-membrane electrodes. The electrode based on L1 exhibited a Nernstian response for Cu2+ ions over a wide concentration range (2×10−1 to 1×10−5 M) with a limit of detection of 8.0×10−6 M (0.5 p.p.m.). The response time of sensor is 15 s, and the membrane can be used for more than 3 months without observing any deviation. The electrode revealed comparatively good selectivities with respect to many alkali, alkaline earth, transition and heavy metal ions, and could be used in a pH range of 2.5–5.5. It was applied to the direct determination and potentiometric titration of the copper(II) ion.  相似文献   

8.
Huang F  Jin G  Liu Y  Kong J 《Talanta》2008,74(5):1435-1441
Phenylephrine (i.e. PHE) and chlorprothixene (i.e. CPT), two effective and important antipsychotic drugs with low redox activity, were found generating an irreversible anodic peak at about +0.89 V (vs. SCE) and +1.04 V in 0.05 M HAc–NaAc (pH 5.0) or NH2CH2COOH–HCl (pH 2.4) buffer solution at poly(4-aminobenzene sulfonic acid) modified glassy carbon electrode (i.e. poly(4-ABSA)/GC), respectively. Sensitive and quantitative measurement for them based on the anodic peaks was established under the optimum conditions. The anodic peak current was linear to PHE and CPT concentrations from 1 × 10−7 to 1.5 × 10−5 M and 2 × 10−6 to 4.5 × 10−5 M, the detection limits obtained were 1 × 10−8 and 1 × 10−7 M, separately. The modified electrode exhibited some excellent characteristics including easy regeneration, high stability, good reproducibility and selectivity. The method proposed was successfully applied to the determination of PHE and CPT in drug injections or tablets and proved to be reliable compared with ultraviolet spectrophotometry. The modified electrode was characterized by electrochemical methods.  相似文献   

9.
Cha KW  Park CI  Park SH 《Talanta》2000,52(6):689-989
Uranium(VI) complexed with aluminon (3-[bis(3-carboxy-4-hydroxy-phenyl)methylene]-6-oxo-1,4-cyclohexadiene-1-carboxylic acid triammonium salt) was determined by adsorptive cathodic stripping voltammetry (ACSV) using a hanging mercury drop electrode. Trace uranium(VI) and zinc(II) can be simultaneously determined in a single scan in the presence of aluminon and urea. Optimal conditions were found to be: accumulation time; 180–200 s, accumulation potential; 50 mV versus Ag/AgCl, scan rate; 40 mV s−1, supporting electrolyte; 0.1 M sodium acetate buffer at pH 6.5–7.0, and concentration of aluminon; 1×10−6 M. The linear range of uranium(VI) and zinc(II) were observed over the concentration range 2–33 and 30–120 ng ml−1, respectively. The detection limit (S/N=3) are 0.2 ng ml−1 (uranium) and 30 ng ml−1 (zinc). A good reproducibility shows RSDs of 2.5–4.0% (n=10). The procedure offers high selectivity, with the presence of urea masking some metal ions.  相似文献   

10.
A new PVC membrane electrode for Zn2+ ions based on tetra(2-aminophenyl) porphyrin (TAPP) as membrane carrier is prepared. The sensor exhibits a linear stable response over a wide concentration range (5.0×10−5 to 1.0×10−1 M) with a slope of 26.5 mV/decade and a limit of detection 3.0×10−5 M (1.96 ppm). It has a response time of about l0 s and can be used for at least 8 months without any divergence in potential. The propose membrane sensor revealed good selectivities for Zn2+ over a wide variety of other metal ions and can be used in pH range of 3.0–6.0. It was successfully applied to the direct determination of zinc in a pharmaceutical sample and also as an indicator electrode in potentiometric titration of Zn2+ ions.  相似文献   

11.
Zareh MM  Ghoneim AK  Abd El-Aziz MH 《Talanta》2001,54(6):1049-1057
The lipophilic ammonium salt of 1-pyrrolidine dicarbodithioic acid (PCDT)[I] was introduced as a selective ionophore for a sensitive Pb-ion selective electrode. Also, the effect of immobilization of 18-crown-6 (CW), into the above membrane, on the electrode performance was discussed. The slope of the PCDT-based [I] electrode was (26–30 mV decade−1), while it was (29-30 mV decade−1) for (PCDT+CW)-based [II] electrode according to the doping time. The linear concentration ranges were (1×10−6–1×10−1 M) and (5×10−5–1×10−1 M) for electrode types [I] and [II] after one-day doping. The working pH ranges were (5.0–10.0) and (7.0–10.0) for electrode types [I] and [II], respectively. Most of the common cations were tested for the evaluation of the electrode selectivity with correlation to the ionic radii of the tested cations. Among them only Na+, Ag+ and Fe3+ were the real interference. Application of using the electrode for the determination of lead in lubrication oil samples was performed with RSD (0.86–1.03%). The obtained results were compared to those of an atomic absorption spectrophotometric method.  相似文献   

12.
Prussian blue has been formed by cyclic voltammetry onto the basal pyrolytic graphite surface to prepare a chemically modified electrode which provides excellent electrocatalysis for both oxidation and reduction of hydrogen peroxide. It is found for the first time that glucose oxidase or -amino oxidase can be incorporated into a Prussian blue film during its electrochemical growth process. Two amperometric biosensors were fabricated by electrochemical codeposition, and the resulting sensors were protected by coverage with a thin film of Nafion. The influence of various experimental conditions was examined for optimum analytical performance. The glucose sensor responds rapidly to substrates with a detection limit of 2 × 10−6 M and a linear concentration range of 0.01–3 mM. There was no interference from 2 mM ascorbic acid or uric acid. Another ( -amino acid) sensor gave a detection limit of 3 × 10−5 M -alanine, injected with a linear concentration range of 7.0 × 10−5-1.4 × 10−2 M. Glucose and -amino acid sensors remain relatively stable for 20 and 15 days, respectively. There is no obvious interference from anion electroactive species due to a low operating potential and excellent permselectivity of Nafion.  相似文献   

13.
De Marco R  Phan C 《Talanta》2003,60(6):1215-1221
The direct flow injection potentiometric (FIP) analysis of phosphate in hydroponic nutrient solution has been carried out using a cobalt-wire ion-selective electrode (ISE). Synthetic hydroponic nutrient solution, commercial hydroponic nutrient solution and working hydroponic farm nutrient solution were analysed for phosphate using the FIP technique. It is shown that FIP results compare favourably to standard methods of analysis such as spectrophotometry and indirect photometric ion-pair chromatography. Reproducible FIP response curves with a slope of −(47.57±0.03) mV per decade and intercept of −(169.7±0.1) mV were obtained for four separate calibrations in the concentration range 5.0×10−4–1.0×10−2 M H2PO4. Anion corrections for interferences by Cl, NO3 and SO42− were applied to all samples using the selectivity coefficients determined independently using a fixed interference method. Nevertheless, it was found that anion corrections were not necessary, as the deviations fell within the bounds of experimental error for the cobalt-wire ISE technique (i.e.±2–5% R.S.D.). The proposed FIP method enables the direct determination of phosphate in hydroponic nutrient solutions.  相似文献   

14.
A PVC membrane electrode for lead ions based on 5,5′-dithiobis-(2-nitrobenzoic acid) as membrane carrier was prepared. The electrode exhibits a Nernstian response for Pb2+ over a wide concentration range (1.0×10−2–4.0×10−6 M). It has a relatively fast response time and can be used for at least 3 months without any divergence in potentials. The proposed electrode revealed good selectivities for Pb2+ over a wide variety of other metal ions and could be used in a pH range of 2.0–7.0. It was used as an indicator electrode in potentiometric titration of lead ions and in direct determination of lead in water samples.  相似文献   

15.
Trace amounts of nickel(II) can function as a trigger (=reaction initiator) in an autocatalytic reaction with the sodium sulfite/hydrogen peroxide system. Based on this finding, sub-μg L−1 levels of nickel(II) were determined by a time measurement using the autocatalytic reaction. The detection range using the above method was 10−9–10−5 M, the detection limit (3σ) was 8.1 × 10−10 M (0.047 μg L−1), and the relative standard deviation was 2.66% at nickel(II) concentration of 10−7 M (n = 7). This method was applied to length detection-flow injection analysis. The detection range for the flow injection analysis was 2 × 10−9–2 × 10−3 M. The detection limit (3σ) was 1.4 × 10−9 M (0.082 μg L−1), and the relative standard deviation was 1.86 at initial nickel(II) concentration of 10−6 M (n = 7).  相似文献   

16.
Chen GN  Zhang L  Lin RE  Yang ZC  Duan JP  Chen HQ  Hibbert DB 《Talanta》2000,50(6):1275-1281
The electrogenerated chemiluminescent (ECL) behavior of hemin at a platinum electrode in the alkaline solution has been investigated in detail. Under the optimum conditions the linear response range of hemin is 1.0×10−5–1.0×10−8 g ml−1, the detection limit was 1.0×10−8 g ml−1, and the relative standard derivation for 1×10−7 g ml−1 hemin was 2.8%. It has been also found that hemin would catalyze the ECL of lucigenin at a platinum electrode in a neutral solution in the presence of hydrogen peroxide, the catalytic ECL intensity was linear with the concentration of hemin in the range of 1.0×10−14–1.0×10−10 g ml−1. IgG labeled with hemin was used to examine the ECL catalytic activity of hemin after conjugating to protein, and the results showed that hemin retained ECL catalytic activity when conjugated to protein.  相似文献   

17.
Zhang N  Zhang X  Zhao Y 《Talanta》2004,62(5):1041-1045
The behavior of the ciprofloxacin (CPFX) complex with copper, Cu(II)L2, at a mercury electrode has been investigated in borax–boric acid buffer. The adsorption phenomena were observed by linear sweep voltammetry. The mechanism of the electrode reaction was found to be reduction of Cu(II)L2 adsorbed on the surface of the electrode by an irreversible charge transfer to metal amalgam, Cu(0)(Hg). In the presence of DNA, the formation of the electrochemically non-active complexes Cu(II)L2–DNA results in the decrease of the equilibrium concentration of Cu(II)L2 and its peak current. Under the optimum conditions, the decrease of the peak current is proportional to DNA concentration. The linear ranges are 6.67×10−8 to 1.20×10−5 g ml−1 for calf thymus DNA (ctDNA), 3.30×10−8 to 2.33×10−6 g ml−1 for fish sperm DNA (fsDNA) and 1.0×10−8 to 1.2×10−6 g ml−1 for yeast RNA. The detection limits are 5.00×10−9, 3.00×10−9 and 2.50×10−9 g ml−1, respectively. This method exhibits good recovery and high sensitivity.  相似文献   

18.
Gong X  Zhou YK  Li HL 《Talanta》2001,55(6):1103-1107
2,2,6,6-Tetramethyl-4-hydroxypiperidine-1-oxyl (TMHPO) shows catalytic electroactivity in homogeneous oxidation of benzoyl hydrazine (BH) on a glassy carbon electrode. The catalytic current is affected by the concentration of TMHPO and the pH of the solution. A possible catalytic reaction mechanism is proposed and a non-toxic, convenient method for the determination of BH in the concentration range 1×10−5–2×10−3 M has been developed.  相似文献   

19.
Simple methods are described for the analysis of sulphate, sulphite and dithionate mixtures by potentiometric titration with lead perchlorate (and use of a lead ion-selective electrode). The error and precision are both about 2–5% for the sulphate concentration range 3 × 10−3 −6 × 10−4M. The sulphur content in fuels derived from refuse was determined by potentiometric titration after bomb-combustion and the results compared favourably with those from the standard BaSO4 gravimetric method.  相似文献   

20.
Norfloxacin, 1-ethyl-6-fluoro-1,4-dihydro-4-oxo-7-(1-piperazinyl)-3-quinoline carboxylic acid (NORH), reacts with aluminium(III) ion forming the strongly fluorescent complex [Al(HNOR)]3+, in slightly acidic medium. The complex shows maximum emission at 440 nm with excitation at 320 nm. The fluorescence intensity is enhanced upon addition of 0.5% sodium dodecylsulphate. Fluorescence properties of the Al-NOR complex were used for the direct determination of trace amounts of NOR in serum. The linear dependence of fluorescence intensity on NOR concentration, at a NOR to Al concentration ratio of 1:10, was found in the concentration range 0.001–2 μg/ml NOR with a detection limit of 0.1 ng/ml. The ability of aluminium (III) ion to form complexes with NOR was investigated by titrations in 0.1 M LiCl medium, using a glass electrode, at 298 K, in the concentration range: 2 × 10−4 ≤ [Al] ≤ 8 × 10−4; 5 × 10−4 ≤ [NOR] ≤ 9 × 10−4 mol/dm3; 2.8 ≤ pH ≤ 8.3. The experimental data were explained by the following complexes and their respective stability constants, log(β ± σ): [Al(HNOR)], (14.60 ± 0.05); [Al(NOR)], (8.83 ± 0.08); [A1(OH)3(NOR)], (−14.9 ± 0.1), as well as several pure hydrolytic complexes of A13+. The structure of the [Al(HNOR)] complex is discussed, with respect to its fluorescence properties.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏