首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this study, a series of experiments were conducted to examine the feasibility of the gas chromatographic approach for the quantification of several odorous volatile organic compounds (VOCs) in environmental samples which included methyl ethyl ketone, isobutyl alcohol, methyl isobutyl ketone, and butyl acetate plus benzene, toluene, and xylene (namely, BTX). The gaseous working standards (WS) of seven compounds were initially calibrated at varying concentration ranges by direct injection (DI) into GC injector. The detection properties of these compounds were then tested with a thermal desorber (TD). The relative sensitivities of three aromatic VOCs differed greatly between DI and TD methods. In contrast, four polar VOCs tend to consistently exhibit relative enhancement in response factors with increasing molecular mass (an exception of butyl acetate), regardless of method. The TD-based analysis was reliable enough to detect all target VOCs below their odor threshold values with their detection limit (DL) values. This TD method, when tested against a number of environmental samples collected from several industrial facilities, confirmed the presence of these odorous VOCs at a wide concentration range.  相似文献   

2.
In this study, a novel quantitation method was developed to facilitate the simple and effective sampling and analysis of phthalates in air based on a sorbent tube-thermal desorption-gas chromatography-mass spectrometry system combination. The performance of the thermal desorption-based analysis was assessed using three different sorbent combinations [1]: quartz wool (QW) [2], glass wool (GW), and [3] quartz wool plus Tenax TA (QWTN) in terms of relative recovery in reference to a direct injection method. There was no significant difference in the average recovery rate for seven target phthalates based on sorbent tube type (QW, 70.2 ± 4.28; GW, 73.2 ± 8.8; and QWTN, 72.5 ± 5.02%). However, the recovery rate of phthalates in each sorbent tube type was distingusihed by physicochemical properties of the target compound (e.g., molecular weight and boiling point). The recovery rate of the QW tube was high for dimethyl phthalate and diethyl phthalate compared to other sorbent tubes, while that of the GW tube exhibited greater values for dibutyl phthalate, benzyl butyl phthalate, di(2-ethylhexyl) adipate, di(2-ethylhexyl) phthalate, and di-n-octyl phthalate. The simple sorbent tube-thermal desorption approach is feasible for the quantitation of seven phthalates present at 0.45–24.5 ng m−3 levels in actual air samples (20 L).  相似文献   

3.
Summary The problem of the separation of 34 volatile organic chlorinated compounds is solved by using three different GC columns selected according to the needs of the particular separation required. The effect of water vapor contained as moisture in the trapped air on the retention of some characteristic compounds is studied. The influence of dead volumes on trap injection is also studied.Dedicated to Prof. Dr. A. Liberti on the occasion of his 70th birthday.  相似文献   

4.
Summary A complex method was developed for the determination of chlorobenzenes in soil and groundwater samples. Samples were taken at two sites in Baranya county, where a mixture of chlorobenzene waste was deposited, causing severe contamination in the environment. Clean-up of these sites demands modern and reliable analytical methods. Several sample preparation techniques were used, such as solid phase microextraction (SPME), supercritical fluid extraction (SFE), and a recently developed thermal desorption method. The applicability of various sample preparation methods was compared by measuring recovery percentages, relative standard deviations and by investigating the matrix dependency of these values. Gas chromatography was used for quantitative determination of chlorobenzenes, using MS, IR, FID and ECD detection techniques. Detection levels were as low as 1 ppt in water, and 10 ppt in soil samples. Chlorobenzene concentration was in the range 1 ppt-1 ppm in water and 100 ppb-100 ppm in soil samples. Identification and calibration of these compounds were performed by quantitative standards. This complex analytical method can be used for rapid and precise quantitative and qualitative determination of chlorobenzenes. Presented at: Balaton Symposium on High-Performance Separation Methods, Siófok, Hungary, September 3–5, 1997  相似文献   

5.
Thermal desorption of the alkaloids in opium samples at 300 degrees C using a vertical microfurnace pyrolyzer was followed by their on-line gas chromatographic (GC) analysis on a large-bore glass capillary column. This method permitted rapid and sensitive determination of the content of the main alkaloid, morphine, in the small (ca. 100 microg) opium samples with a relative standard deviation within 4% for 5 runs. The observed morphine contents of about 12 to 15 w/w% in the given opium samples were in fairly good agreement with those estimated by a conventional GC-MS method.  相似文献   

6.
A homologous series of 2,4-dichlorobenzyl alkyl ethers (DCBEs) have been synthesized and purified for use as retention index calibrants and internal standards. They are stable, sensitive to ECD and FID and ideal for GC-MS, with base peaks at m/z 159/161. The retention index calibration against the n-alkanes for a linear temperature program (LTP) series is given and recommendations made for the most suitable members of the DCBE series for use as internal standards in organochlorine (OC) residue analysis.  相似文献   

7.
8.
A direct, simple and solvent‐free method based on headspace stir bar sorptive extraction and thermal desorption gas chromatography with mass spectroscopy was developed to determine 13 musk fragrances (six polycyclic musks, three nitro musks and four macrocyclic musks) in sludge without sample treatment. The optimal headspace stir bar sorptive extraction conditions were achieved when a polydimethylsiloxane stir bar was exposed for 45 min in the headspace of a 10 mL vial filled with 100 mg of sludge mixed with 0.2 mL of water stirred at 750 rpm at 80°C. The stir bar was then desorbed in the thermal desorption gas chromatography and mass spectrometry system, obtaining limits of detection between 5 and 30 ng/g. The method applicability was tested with sewage sludge from two urban wastewater treatment plants and from a potable water treatment plant. Results showed galaxolide and tonalide to be the most abundant musk fragrances found in wastewater treatment plants with maximal concentrations of 9240 and 7500 ng/g, respectively. Maximum concentration levels between 35 and 635 ng/g were found for musk ketone, musk moskene, traseolide, phantolide and celestolide in this kind of samples. Concentrations below the limits of quantitation of phantolide, galaxolide, tonalide and musk ketone were found in sludge from a potable water treatment plant.  相似文献   

9.
K. L. Yang  J. G. Lo 《Chromatographia》1997,44(7-8):405-410
Summary By participating in an International Hydrocarbons Intercomparison Experiment, a method for the determination of nonmethane hydrocarbons was evaluated. The method involves Tenax-TA sampling, thermal desorption and preconcentration combined with capillary gas chromatography with flame ionization detection. Sixty target compounds from C2 to C11 were separated by using a megabore capillary column with a thick film of bonded nonpolar siloxane stationary phase (5 μm, Rtx-1). The unusually thick film in the column was an advantage for resolving light hydrocarbons (C2−C3) at room temperature. The percent difference between the National Institute of Standards and Technology (NIST) and our laboratory in the intercomparison experiment is in the range of 0.99%–19.70%.  相似文献   

10.
A novel gas chromatography/high resolution mass spectrometry method coupled with multisorbent thermal desorption cartridges has been developed for the determination of volatile neutral polyfluorinated iodine alkanes (PFIs) in airborne samples. It allows, for the first time, simultaneous analysis of four mono-iodized perfluorinated alkanes, three diiodized perfluorinated alkanes and four mono-iodized polyfluorinated telomers in ambient air samples. 3.75 L air sample was passed through a sorbent tube packed with 150 mg of Tenax TA and 200 mg of Carbograph 1TD for analyte adsorption. Important factors during the analysis procedures, such as safe sampling volume, air sampling rate, analyte desorption and transfer strategies, were optimized and good thermal desorption efficiencies were obtained. The method detection limit (MDL) concentration ranged from 0.04 pg/L for 1H,1H,2H,2H-perfluorododecyl iodide to 1.2 pg/L for perfluorohexyl iodide, and instrument response of a seven-point calibration was linear in the range of 10–1000 pg. Travel spike recoveries ranged from 83% to 116%. Small variabilities of less than 36% were obtained near the MDLs and the differences between triplicates were even smaller (2.1–7.3%) at 200 pg spiked level. The method was successfully applied to analyze ambient air samples collected near a point source, and five PFIs were identified (10.8–85.0 pg/L), with none of the analytes detectable at the background site.  相似文献   

11.
12.
We previously showed that the relative response factors of volatile compounds were predictable from either combustion enthalpies or their molecular formulae only 1 . We now extend this prediction to silylated derivatives by adding an increment in the ab initio calculation of combustion enthalpies. The accuracy of the experimental relative response factors database was also improved and its population increased to 490 values. In particular, more brominated compounds were measured, and their prediction accuracy was improved by adding a correction factor in the algorithm. The correlation coefficient between predicted and measured values increased from 0.936 to 0.972, leading to a mean prediction accuracy of ± 6%. Thus, 93% of the relative response factors values were predicted with an accuracy of better than ± 10%. The capabilities of the extended algorithm are exemplified by (i) the quick and accurate quantification of hydroxylated metabolites resulting from a biodegradation test after silylation and prediction of their relative response factors, without having the reference substances available; and (ii) the rapid purity determinations of volatile compounds. This study confirms that Gas chromatography with a flame ionization detector and using predicted relative response factors is one of the few techniques that enables quantification of volatile compounds without calibrating the instrument with the pure reference substance.  相似文献   

13.
A novel solid-phase extraction element is developed for sorptive enrichment of dilute analytes from liquid samples with high extraction efficiencies due to its larger amounts of polydimethylsiloxane (PDMS) absorbent than the conventional syringe type of solid-phase microextraction (SPME). The extraction element is made of titanium (Ti) open tubular tube (30 mm x 1.2 mm i.d. x 1.6 mm o.d.) coated with a chemically bonded layer of PDMS (500 microm in thickness). The extraction element combined with thermal desorption-gas chromatography-mass spectrometry using a pyrolysis-gas chromatography-mass spectrometry system was used to extract and analyze a typical herbicide, bethrodine in water samples over a concentration range from 2.5 to 2.5 x 10(4) ng/l. Thus obtained calibration curve showed good linearity for the tested whole concentration range with regression coefficient of 0.992. Detection limit of 0.5 ng/l level was achieved and the reproducibility of the measurements for bethrodine at 10 ng/l level was found to be fairly good with relative standard deviation below 7.5%.  相似文献   

14.
选用弱极性通用毛细管色谱柱(5%苯基,95%甲基聚硅氧烷)、冷柱头进样及氢火焰离子化检测器(FID),采用程序升温,以甲基异丁酮为内标物,建立了测定二碳酸二甲酯(DMDC)纯度的气相色谱法。在优化的条件下,方法相关系数r=0.9996,检测限为0.5 mg/kg,线性范围为1.0~100 mg/kg,对实际样品进行测定,加标回收率为90.2%~98.7%,相对标准偏差为2.9%~5.2%。方法适用于食品添加剂二碳酸二甲酯的纯度分析。  相似文献   

15.
Fast and conventional gas chromatography (GC) techniques were applied to nine different lipidic matrices (butter, lard, tallow, and peanut, corn, sunflower, soya, olive, menhaden oils). Simultaneous methylic transesterification was performed on all samples prior to GC analysis. Several practical aspects concerning high speed analysis were investigated, such as the great increase in linear velocity, the use of fast temperature ramps, column sample capacity and detection systems. Analytical results showed certain losses in resolution, balanced by a consistent reduction in analysis time. The actual time savings were variable (60-70 min) as they were dependent on the complexity of the sample while the speed enhancement factor was equal to 10.5. Peak identification was achieved by means of different information sources, such as fast GC-mass spectrometry (MS), linear retention indices and comprehensive two-dimensional (2D) gas chromatography group patterns. The method developed was shown to be applicable in routine applications on complex natural samples.  相似文献   

16.
Summary A comparison of some adsorbents, commonly used for trapping trace volatile organic pollutants followed by thermal desorption, is presented. The evaluation has been performed on 12 compounds representative of the main classes of organic substances. Breakthrough volumes and desorption recoveries have been measured. Every adsorbent gave good results for a range of compounds, but none were able to cover all the compounds examined. Thus, a multilayer trap utilising the best features of each adsorbent was introduced with very good results.  相似文献   

17.
Summary A quantitative method is described for the analysis of trace quantities of benzene, toluene and the C8 aromatics in aqueous effluents. The light aromatics are pre-concentrated using a purge and trap technique and are separated into individual components on a gas chromatographic system. The limit of detection is 10 ppb. The sampling, transportation, and storage of the effluent in order to obtain a representative sample and to prevent losses are discussed. The need for the analysis to be carried out as quickly as possible after sampling is stressed.Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

18.
Dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detector (GC-FID) was developed for preconcentration and determination of some nitroaromatic compounds in wastewater samples. The effects of different variables on the extraction efficiency were studied simultaneously using experimental design. The variables of interest in the DLLME process were extraction and disperser solvent volumes, salt effect, sample volume, extraction temperature and extraction time. A Plackett-Burman design was performed for screening of variables in order to determine the significant variables affecting the extraction efficiency. Then, the significant factors were optimized by using a central composite design (CCD) and the response surface equations were derived. The optimum experimental conditions found from this statistical evaluation included: sample volume, 9 mL; extraction solvent (CCl4) volume, 20 μL; disperser solvent (methanol) volume, 0.75 mL; sodium chloride concentration, 3% (w/v); extraction temperature, 20 °C and extraction time, 2 min. Under the optimum conditions, the preconcentration factors were between 202 and 314. Limit of detections (LODs) ranged from 0.09 μg L−1 (for 2-nitrotoluene) to 0.5 μg L−1 (for 2,4-dinitrotoluene). Linear dynamic ranges (LDRs) of 0.5-300 and 1-400 μg L−1 were obtained for mononitrotoluenes (MNTs) and dinitrotoluenes (DNTs), respectively. Performance of the present method was evaluated for extraction and determination of nitroaromatic compounds in wastewater samples in the range of microgram per liter and satisfactory results were obtained (RSDs < 10.1%).  相似文献   

19.
Zhang  M.  Phillips  J. B. 《Chromatographia》1994,39(5-6):294-298
Summary The inside wall of an uncoated polyethylene capillary traps organic substances from a water sample pumped through it by a nitrogen gas stream. Heating the capillary in a chromatographic oven slowly releases the trapped organic substances from the wall. Nitrogen carrier gas transports sample substances released through a thermal desorption modulator and onto a chromatographic column. Pulsing the temperature of the modulator modulates the concentrations of sample components as they enter the column. Computing the cross correlation of the detector output signal against the applied modulation signal generates the chromatogram. Detection limits below 1 ppb are possible using a flame ionization detector. No sample pretreatment or cold trap is required.  相似文献   

20.
The Baccharis genus has more than 400 species of aromatic plants. However, only approximately 50 species have been studied in oil composition to date. From these studies, very few take into consideration differences between male and female plants, which is a significant and distinctive factor in Baccharis in the Asteraceae family. Baccharis articulata is a common shrub that grows wild in south Brazil, northern and central Argentina, Bolivia, Paraguay and Uruguay. It is considered to be a medicinal plant and is employed in traditional medicine. We report B. articulata male and female volatile composition obtained by simultaneous distillation–extraction technique and analyzed by gas chromatography with mass spectrometry. Also, an assessment of aromatic differences between volatile extracts was evaluated by gas chromatography with olfactometry. The results show a very similar chemical composition between male and female extracts, with a high proportion of terpene compounds of which β‐pinene, limonene and germacrene D are the main components. Despite the chemical similarity, great differences in aromatic profile were found: male plant samples exhibited the strongest odorants in number and intensity of aromatic attributes. These differences explain field observations which indicate differences between male and female flower aroma, and might be of ecological significance in the attraction of pollinating insects.  相似文献   