首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
In negative ion fast atom bombardment (FAB) mass spectrometry, the use of a liquid matrix comprised of 15-crown-5—glycerol (1:10, v/v) enabled the molecular weight determination of small amounts of non-volatile acidic molecules. This ionization process could result in detection limits of less than one-fifth of those obtained using only glycerol as matrix. The function of the matrix as a proton acceptor is emphasized.  相似文献   

2.
3.
The continuous-flow fast atom bombardment probe performs equally well with or without a high-performance liquid chromatography column producing clean spectra containing little or no background noise. Its function as a liquid chromatography-mass spectrometry interface for labile and involatile samples has been illustrated with reference to dansylated amino acids. The versatility of the new probe has been exemplified by on-line enzymatic peptide sequencing.  相似文献   

4.
Although frit-fast atom bombardment (frit-FAB) and continuous-flow FAB mass spectrometry have become standard methods for the analysis of peptides and peptide mixtures, these techniques have not been applied previously to the analysis of oligonucleotides. Mobilephase composition, flow rate, and sample size were optimized for the analysis of oligonucleotides by negative ion frit-FAB mass spectrometry (a type of continuous-flow FAB mass spectrometry). With a mobile phase consisting of methanol/water/triethanolamine (80:20:0.5, v/v/w), flow injection frit-FAB analysis of oligonucleotides showed lower limits of detection compared to standard probe FAB mass spectrometry. For example, in order to obtain a signal-to-noise ratio of 3:1, 38 prnol of d(GTIAAC) were required for frit-FAB mass spectrometry and 62 pmol were required for standard probe FAB mass spectrometry. The largest difference between frit-FAB and standard probe FAB was observed for d(pC)5, for which the limit of detection by frit-FAB was approximately 11-fold lower than by standard FAB mass spectrometry. Adjustment of the mobile phase to pH 7 with trifluoroacetic acid increased the limit of detection (reduced sensitivity) a minimum of sixfold. Equimolar mixtures of two or three oligonucleotides produced deprotonated molecules in identical relative abundances whether analyzed by frit-FAB or standard probe FAB mass spectrometry. Finally, frit-FAB liquid chromatography mass spectrometry was demonstrated by separating mixtures of oligonucleotides on a β -cyclodextrin high-performance liquid chromatography column with a mobile phase containing methanol, water, and triethanolamine.  相似文献   

5.
Examples of various chemical reactions occurring in the matrix or in the selvedge region in fast atom bombardment (FAB) mass spectrometry are discussed. These are categorized as oxidations and reductions; substitutions; clusterings and additions; and sample decomposition or transformation. Some reactions observed showed significant time behaviour and in one case it was possible to determine rate constants. These data suggest that chemical reactions can be accelerated significantly by fast atom bombardment.  相似文献   

6.
Analyses of a series of nitroaromatic compounds using fast atom bombardment (FAB) mass spectrometry are discussed. An interesting ion-molecule reaction leading to [M + O ? H]? ions is observed in the negative ion FAB spectra. Evidence from linked-scan and collision-induced dissociation spectra proved that [M + O ? H]? ions are produced by the following reaction: M + NO2? → [M + NO2]? → [M + O ? H]?. These experiments also showed that M ions are produced in part by the exchange of an electron between M and NO2? species. All samples showed M, [M ? H]? or both ions in their negative ion FAB spectra. Not all analytes studied showed either [M + H]+ and/or M+˙ in the positive ion FAB spectra. No M+˙ ions were observed for ions having ionization energies above ~9 eV.  相似文献   

7.
The mechanism of a dehalogenation reaction that occurs during fast atom bombardment (FAB) mass spectrometry was examined using halogenated nucleosides as model compounds. For aglycone-halogenated nucleosides, an inverse linear relationship exists between the extent of FAB dehalogenation and the calculated electron affinity of an individual nucleoside. The degree of dehalogenation for a given nucleoside also varies inversely with the calculated electron affinity of most FAB matrices. The observed dehalogenation reaction can be completely inhibited when matrices with positive electron affinities, such as 3-nitrobenzyl alcohol and 2-hydroxyethyl disulfide, are used. High-performance liquid chromatographic analysis of the bulk glycerol matrix following exposure to the FAB beam indicates measurable amounts of dehalogenated product, suggesting that this reaction occurs in the condensed phase prior to gas-phase ion formation. A dehalogenation mechanism involving thermal electron capture and subsequent negative charge stabilization is consistent with these observations.  相似文献   

8.
The fragmentation patterns of N-phosphoamino acids in negative-ion fast atom bombardment mass spectrometry (FABMS) showed different characteristics to those in positive-ion FABMS. Six typical N-diisopropyloxyphorphorylamino acids all had intense [M ? 1]? peaks, and they underwent similar fragmentation pathways. In general, the elimination of one alkene molecule followed by the loss of one molecule of alcohol occurred. They also favoured an N → O rearrangement reaction, followed by fragmentation to (RO)2 PO2? and (RO) (HO)PO2?.  相似文献   

9.
10.
The efficacy of m-nitrobenzyl alcohol (NBA) as a solvent (matrix) for fast atom bombardment (FAB) mass spectrometry of a group of pyrazolate-bridged dirhodium A-frame complexes has been assessed. Although NBA is frequently used to mitigate the formation of artifacts in FAB/MS of organometallics and other materials susceptible to bombardment-induced reactions, substantial evidence indicates that such reactions cause the formation of artifacts in the spectra obtained here. Parallel absorption spectroscopic studies have established that NBA is capable of inducing both oxidation and reduction reactions independent of ion bombardment, depending on analyte reduction half-wave potential (E1/2). From the known electrochemistry of the complexes studied, it can be estimated that 1020 mV > E1/2 > 500 mV for the reaction of NBA serving as a reducing agent, while 500 mV > E1/2 > 424 mV for the reduction potential of NBA. However, in the presence of bombardment the former E1/2 must be at least as low as 356 mY, and the latter E1/2 must be at least as high as 1188 mY. The kinetics of redox reactions involving NBA, and therefore their influence on the appearance of FAB mass spectra, will be highly sample-dependent. However, this study illustrates an important potential role for redox reactions when NBA is used as a solvent, especially in the presence of bombardment in FAB/MS. Although analyte reaction products could be identified, substantial efforts aimed at identifying NBA oxidation and reduction products did not yield any definitive results due to the complexity of product mixtures.  相似文献   

11.
采用快原子轰击质谱法(FAB)对漠王族中宽漠王(Mantichorula grandis Semenow)体中的微量元素K’进行定量测定。以锂离子作为测定时的内标物,在质谱图中用K 和Li 的丰度比定出钾离子的含量。研究了有无底物,快原子轰击能量,以及共存元素等因素对测定结果的影响。对实验结果的精密度,准确度以及检出限进行了测定。  相似文献   

12.
13.
Positive ion fast atom bombardment mass spectrometry (FABMS) of in situ N-phosphorylated oligopeptides showed intense quasi-molecular ions together with the successive alkene loss fragment ions, which afford multiple checks of the unequivocal reality of the relative molecular mass of the tested samples. More interesting, in a novel cleavage pattern only the N-phosphoryl fragment ions gave intense peaks, the C-terminal series ions being suppressed. For each of the N-terminal ions, losses of alkenes also occur to provide multiple checks for the existence of these ions. The FABMS of the in situ N- phosphorylated oligopeptides might provide an easily accessible routine method for peptide sequencing.  相似文献   

14.
An integral probe for capillary zone electrophoresis/continuous-flow fast atom bombardment mass spectrometry was constructed and operated in either the coaxial or liquid-junction interface mode. Results using these interfaces for the analyses of synthetic peptides are presented. The coaxial arrangement attains the best electrophoretic performance, generally providing a greater number of theoretical plates. However, in that the electrophoresis times are generally greater for the liquid-junction interface because there is no mechanical flow resulting from the source vacuum, the overall separation efficiency of the liquid-junction interface is equal to or greater than that of the coaxial interface. In addition, the liquid-junction interface is easier to set up and operate, and allows larger inner diameter capillaries to be used to achieve higher sample loads.  相似文献   

15.
A new technique using negative-ion fast atom bombardment mass spectrometry for the analysis of xanthates and related compounds is described. Electron impact and positive-ion fast atom bombardment mass spectrometry produced no structurally related fragment ions or observable molecular ions at the expected m/z values. It was demonstrated that negative-ion fast atom bombardment ionization was the most suitable method of ionization for structure elucidation studies for the compounds described.  相似文献   

16.
Caesium fluoride was shown to afford advantages over caesium iodide as a mass-calibration compound for fast atom bombardment mass spectrometry.  相似文献   

17.
18.
The mass spectral fragmentation of echinacoside, a pharmacologically active caffeoyl-glycoside isolated from Echinacea angustifolia roots, has been investigated using different soft-ionization techniques, field desorption and fast atom bombardment (positive and negative ions) mass Spectrometry. Both ionization modes are successful in molecular mass determination and furnish approximately equivalent structural information. A fast atom bombardment tandem mass spectrometry approach (negative ions) was developed for the study of the fragmentation pathways and for the detection of echinacoside in crude plant extracts. The results demonstrate the usefulness of this technique for the rapid search of this important caffeoyl-glucoside directly in natural complex matrices.  相似文献   

19.
Continuous-flow fast atom bombardment has been used to analyze eicosanoids by selected-ion monitoring on a sector-field mass spectrometer operating in the negative-ion mode. The method has been optimized with respect to solvent composition and flow-rates. Detection limits were below 50 pg, and under optimal conditions a linear relationship between response and amount of substance was achieved. The method was successfully applied to the analysis of two spiked urine samples.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号