首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 546 毫秒
1.
Imaging experiments at the European X‐ray Free Electron Laser (XFEL) require silicon pixel sensors with extraordinary performance specifications: doses of up to 1 GGy of 12 keV photons, up to 105 12 keV photons per 200 µm × 200 µm pixel arriving within less than 100 fs, and a time interval between XFEL pulses of 220 ns. To address these challenges, in particular the question of radiation damage, the properties of the SiO2 layer and of the Si–SiO2 interface, using MOS (metal‐oxide‐semiconductor) capacitors manufactured on high‐resistivity n‐type silicon irradiated to X‐ray doses between 10 kGy and 1 GGy, have been studied. Measurements of capacitance/conductance–voltage (C/G–V) at different frequencies, as well as of thermal dielectric relaxation current (TDRC), have been performed. The data can be described by a dose‐dependent oxide charge density and three dominant radiation‐induced interface states with Gaussian‐like energy distributions in the silicon band gap. It is found that the densities of the fixed oxide charges and of the three interface states increase up to dose values of approximately 10 MGy and then saturate or even decrease. The shapes and the frequency dependences of the C/G–V measurements can be quantitatively described by a simple model using the parameters extracted from the TDRC measurements.  相似文献   

2.
The X‐ray mass attenuation coefficients of silver were measured in the energy range 5–20 keV with an accuracy of 0.01–0.2% on a relative scale down to 5.3 keV, and of 0.09–1.22% on an absolute scale to 5.0 keV. This analysis confirms that with careful choice of foil thickness and careful correction for systematics, especially including harmonic contents at lower energies, the X‐ray attenuation of high‐Z elements can be measured with high accuracy even at low X‐ray energies (<6 keV). This is the first high‐accuracy measurement of X‐ray mass attenuation coefficients of silver in the low energy range, indicating the possibility of obtaining high‐accuracy X‐ray absorption fine structure down to the L1 edge (3.8 keV) of silver. Comparison of results reported here with an earlier data set optimized for higher energies confirms accuracy to within one standard error of each data set collected and analysed using the principles of the X‐ray extended‐range technique (XERT). Comparison with theory shows a slow divergence towards lower energies in this region away from absorption edges. The methodology developed can be used for the XAFS analysis of compounds and solutions to investigate structural features, bonding and coordination chemistry.  相似文献   

3.
A quantitative analysis of the crucial characteristics of currently used and promising materials for X‐ray refractive optics is performed in the extended energy range 8–100 keV. According to the examined parameters, beryllium is the material of choice for X‐ray compound refractive lenses (CRLs) in the energy range 8–25 keV. At higher energies the use of CRLs made of diamond and the cubic phase of boron nitride (c‐BN) is beneficial. It was demonstrated that the presence of the elements of the fourth (or higher) period has a fatal effect on the functional X‐ray properties even if low‐Z elements dominate in the compound, like in YB66. Macroscopic properties are discussed: much higher melting points and thermal conductivities of C and c‐BN enable them to be used at the new generation of synchrotron radiation sources and X‐ray free‐electron lasers. The role of crystal and internal structure is discussed: materials with high density are preferable for refractive applications while less dense phases are suitable for X‐ray windows. Single‐crystal or amorphous glass‐like materials based on Li, Be, B or C that are free of diffuse scattering from grain boundaries, voids and inclusions are the best candidates for applications of highly coherent X‐ray beams.  相似文献   

4.
X‐ray free‐electron lasers (XFELs) generate sequences of ultra‐short spatially coherent pulses of X‐ray radiation. A diffraction focusing spectrometer (DFS), which is able to measure the whole energy spectrum of the radiation of a single XFEL pulse with an energy resolution of ΔE/E? 2 × 10?6, is proposed. This is much better than for most modern X‐ray spectrometers. Such resolution allows one to resolve the fine spectral structure of the XFEL pulse. The effect of diffraction focusing occurs in a single‐crystal plate due to dynamical scattering, and is similar to focusing in a Pendry lens made from a metamaterial with a negative refraction index. Such a spectrometer is easier to operate than those based on bent crystals. It is shown that the DFS can be used in a wide energy range from 5 keV to 20 keV.  相似文献   

5.
Recent research progress using X‐ray cryo‐crystallography with the photon beams from third‐generation synchrotron sources has resulted in recognition that this intense radiation commonly damages protein samples even when they are held at 100 K. Other structural biologists examining thin protein crystals or single particle specimens encounter similar radiation damage problems during electron diffraction and imaging, but have developed some effective countermeasures. The aim of this concise review is to examine whether analogous approaches can be utilized to alleviate the X‐ray radiation damage problem in synchrotron macromolecular crystallography. The critical discussion of this question is preceded by presentation of background material on modern technical procedures with electron beam instruments using 300–400 kV accelerating voltage, low‐dose exposures for data recording, and protection of protein specimens by cryogenic cooling; these practical approaches to dealing with electron radiation damage currently permit best resolution levels of 6 Å (0.6 nm) for single particle specimens, and of 1.9 Å for two‐dimensional membrane protein crystals. Final determination of the potential effectiveness and practical value of using such new or unconventional ideas will necessitate showing, by experimental testing, that these produce significantly improved protection of three‐dimensional protein crystals during synchrotron X‐ray diffraction.  相似文献   

6.
A practical method for operating existing undulator synchrotron beamlines at photon energies considerably higher than their standard operating range is described and applied at beamline 19‐ID of the Structural Biology Center at the Advanced Photon Source enabling operation at 30 keV. Adjustments to the undulator spectrum were critical to enhance the 30 keV flux while reducing the lower‐ and higher‐energy harmonic contamination. A Pd‐coated mirror and Al attenuators acted as effective low‐ and high‐bandpass filters. The resulting flux at 30 keV, although significantly lower than with X‐ray optics designed and optimized for this energy, allowed for accurate data collection on crystals of the small protein crambin to 0.38 Å resolution.  相似文献   

7.
The majority of the beamlines at the Brazilian Synchrotron Light Source Laboratory (LNLS) use radiation produced in the storage‐ring bending magnets and are therefore currently limited in the flux that can be used in the harder part of the X‐ray spectrum (above ~10 keV). A 4 T superconducting multipolar wiggler (SCW) was recently installed at LNLS in order to improve the photon flux above 10 keV and fulfill the demands set by the materials science community. A new multi‐purpose beamline was then installed at the LNLS using the SCW as a photon source. The XDS is a flexible beamline operating in the energy range between 5 and 30 keV, designed to perform experiments using absorption, diffraction and scattering techniques. Most of the work performed at the XDS beamline concentrates on X‐ray absorption spectroscopy at energies above 18 keV and high‐resolution diffraction experiments. More recently, new setups and photon‐hungry experiments such as total X‐ray scattering, X‐ray diffraction under high pressures, resonant X‐ray emission spectroscopy, among others, have started to become routine at XDS. Here, the XDS beamline characteristics, performance and a few new experimental possibilities are described.  相似文献   

8.
The X‐ray optics group at the Swiss Light Source in co‐operation with RIT (Rigaku Innovative Technologies) have investigated seven different multilayer samples. The goal was to find an ideal multilayer structure for the energy range between 6 keV and 20 keV in terms of energy resolution and reflectivity. Such multilayer structures deposited on substrates can be used as X‐ray monochromators or reflecting synchrotron mirrors. The measured reflectivities agree with the simulated ones. They cover a reflectivity range from 45% to 80% for energies between 6 keV and 10 keV, and 80% to 90% for energies between 10 keV and 20 keV. The experimentally measured energy resolution of the samples lies between 0.3% and 3.5%.  相似文献   

9.
Copper single crystals were implanted off-axis at room temperature with carbon, neon, argon and xenon ions having energies ranging from 50 to 150 keV. Deep radiation damage was observed by α-particle channelling in a backscattering geometry. The total damage range was found to depend primarily on the ion energy, whereas the influence of the atomic number of the ion was significant only with xenon.  相似文献   

10.
X‐ray Fluorescence (XRF) with a scanning electron microscope (SEM) is a valuable completion of the analytical capabilities of SEMs. Small and compact micro‐focus x‐ray sources are mounted to the microscope chamber, and the x‐ray spectra are monitored with conventional EDS systems. Up to now the x‐ray tubes used for the micro‐focus x‐ray sources are equipped with beryllium windows about 100 µm thick. The poly‐capillary x‐ray lenses have their transmission maximum at photon energies around 10 keV. It drops down in both low‐ and high‐energy ranges. Hence, L‐radiation from an Mo or Rh target will be strongly attenuated, and the excitation of fluorescence in the soft x‐ray range becomes very ineffective. A new micro‐focus x‐ray source was developed. It is characterised by a lower self‐absorption in the tube target, thin beryllium windows and an x‐ray optics having a large distance between its foci and the maximum of transmission at about 5 keV. Thus K line fluorescence of light elements becomes effectively excited by the L‐radiation from Mo or Rh tube targets. The detection limit for sodium oxide in glass was found to be below 1 mass%. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
A dedicated in‐vacuum X‐ray detector based on the hybrid pixel PILATUS 1M detector has been installed at the four‐crystal monochromator beamline of the PTB at the electron storage ring BESSY II in Berlin, Germany. Owing to its windowless operation, the detector can be used in the entire photon energy range of the beamline from 10 keV down to 1.75 keV for small‐angle X‐ray scattering (SAXS) experiments and anomalous SAXS at absorption edges of light elements. The radiometric and geometric properties of the detector such as quantum efficiency, pixel pitch and module alignment have been determined with low uncertainties. The first grazing‐incidence SAXS results demonstrate the superior resolution in momentum transfer achievable at low photon energies.  相似文献   

12.
The Hard X‐ray Photo‐Electron Spectroscopy (HAXPES) beamline (PES‐BL14), installed at the 1.5 T bending‐magnet port at the Indian synchrotron (Indus‐2), is now available to users. The beamline can be used for X‐ray photo‐emission electron spectroscopy measurements on solid samples. The PES beamline has an excitation energy range from 3 keV to 15 keV for increased bulk sensitivity. An in‐house‐developed double‐crystal monochromator [Si (111)] and a platinum‐coated X‐ray mirror are used for the beam monochromatization and manipulation, respectively. This beamline is equipped with a high‐energy (up to 15 keV) high‐resolution (meV) hemispherical analyzer with a microchannel plate and CCD detector system with SpecsLab Prodigy and CasaXPS software. Additional user facilities include a thin‐film laboratory for sample preparation and a workstation for on‐site data processing. In this article, the design details of the beamline, other facilities and some recent scientific results are described.  相似文献   

13.
A previous paper [Nave & Hill (2005). J. Synchrotron Rad. 12 , 299–303] examined the possibility of reduced radiation damage for small crystals (10 µm and below in size) under conditions where the photoelectrons could escape from the sample. The conclusion of this paper was that higher‐energy radiation (e.g. 40 keV) could offer an advantage as the photoelectron path length was greater and less energy would be deposited in the crystal. This paper refines these calculations further by including the effects of energy deposited owing to Compton scattering and the energy difference between the incident photon and the emitted photoelectron. An estimate is given for the optimum wavelength for collecting data from a protein crystal of a given size and composition. Another way of reducing radiation damage from a protein crystal is to collect data with a very short pulsed X‐ray source where a single image can be obtained before subsequent radiation damage occurs. A comparison of this approach compared with the use of shorter wavelengths is made.  相似文献   

14.
X‐ray microscopy is a commonly used method especially in material science application, where the large penetration depth of X‐rays is necessary for three‐dimensional structural studies of thick specimens with high‐Z elements. In this paper it is shown that full‐field X‐ray microscopy at 6.2 keV can be utilized for imaging of biological specimens with high resolution. A full‐field Zernike phase‐contrast microscope based on diffractive optics is used to study lipid droplet formation in hepatoma cells. It is shown that the contrast of the images is comparable with that of electron microscopy, and even better contrast at tender X‐ray energies between 2.5 keV and 4 keV is expected.  相似文献   

15.
A multiple‐analyser‐crystal spectrometer for non‐resonant inelastic X‐ray scattering spectroscopy installed at beamline ID16 of the European Synchrotron Radiation Facility is presented. Nine analyser crystals with bending radii R = 1 m measure spectra for five different momentum transfer values simultaneously. Using a two‐dimensional detector, the spectra given by all analysers can be treated individually. The spectrometer is based on a Rowland circle design with fixed Bragg angles of about 88°. The energy resolution can be chosen between 30–2000 meV with typical incident‐photon energies of 6–13 keV. The spectrometer is optimized for studies of valence and core electron excitations resolving both energy and momentum transfer.  相似文献   

16.
用1.4GeV氢离子对多层堆叠的厚约53m的聚苯乙烯薄膜在室温和真空条件下进行了辐照;对辐照后的样品进行了从红外到紫外的光吸收测量.测量结果显示,材料经高能红离子辐照后发生化学降解,降解过程强烈依赖于电子能损;在能量沉积密度很高的径迹芯中,分子主链和苯环均遭到破坏;在电子能损高于0.77keV/nm时有炔基产生.  相似文献   

17.
Hard X‐ray Fabry–Perot resonators (FPRs) made from sapphire crystals were constructed and characterized. The FPRs consisted of two crystal plates, part of a monolithic crystal structure of Al2O3, acting as a pair of mirrors, for the backward reflection (0 0 0 30) of hard X‐rays at 14.3147 keV. The dimensional accuracy during manufacturing and the defect density in the crystal in relation to the resonance efficiency of sapphire FPRs were analyzed from a theoretical standpoint based on X‐ray cavity resonance and measurements using scanning electron microscopic and X‐ray topographic techniques for crystal defects. Well defined resonance spectra of sapphire FPRs were successfully obtained, and were comparable with the theoretical predictions.  相似文献   

18.
During diffraction experiments even cryo‐cooled protein crystals can be significantly damaged due to chemical and physical changes induced by absorbed X‐ray photons. The character and scale of the observed effects depend strongly on the temperature and the composition of crystals. The absorption of radiation energy results in incremental regular changes to the crystal structure, making its impact on the process of solving the structure strongly correlated with other experimental variables. An understanding of all the dependencies is still limited and does not allow for a precise prediction of the outcome of a particular diffraction experiment. Results are presented of diffraction experiments performed under different experimental conditions. The influence of temperature and crystal composition on different characteristics of radiation damage is analyzed. The observed effects are discussed in terms of their impact on data processing and phasing procedures.  相似文献   

19.
Soft‐X‐ray angle‐resolved photoelectron spectroscopy (ARPES) with photon energies around 1 keV combines the momentum space resolution with increasing probing depth. The concepts and technical realisation of the new soft‐X‐ray ARPES endstation at the ADRESS beamline of SLS are described. The experimental geometry of the endstation is characterized by grazing X‐ray incidence on the sample to increase the photoyield and vertical orientation of the measurement plane. The vacuum chambers adopt a radial layout allowing most efficient sample transfer. High accuracy of the angular resolution is ensured by alignment strategies focused on precise matching of the X‐ray beam and optical axis of the analyzer. The high photon flux of up to 1013 photons s?1 (0.01% bandwidth)?1 delivered by the beamline combined with the optimized experimental geometry break through the dramatic loss of the valence band photoexcitation cross section at soft‐X‐ray energies. ARPES images with energy resolution up to a few tens of meV are typically acquired on the time scale of minutes. A few application examples illustrate the power of our advanced soft‐X‐ray ARPES instrumentation to explore the electronic structure of bulk crystals with resolution in three‐dimensional momentum, access buried heterostructures and study elemental composition of the valence states using resonant excitation.  相似文献   

20.
Tabulated mass absorption coefficient data from the XCOM, Chantler and ion beam analysis (IBA) Handbook are compared, and differences are shown against X‐ray energy and target atomic number. Over the X‐ray energy range 1–40 keV systematic differences of several tens of percent are noted between these datasets, particularly for the earlier IBA Handbook dataset. The influence of these different mass absorption coefficients on the X‐ray yields for thick target proton‐induced X‐ray emission (PIXE) are investigated and compared as a function of X‐ray energy and target atomic number. For contemporary experimental PIXE users trying to work quantitatively over a broad range of elements and X‐ray energies, differences between PIXE results obtained using these three separate mass attenuation coefficient datasets can be larger than the typical accuracy limits of ±3% to ±5%. There are systematic differences in the mass attenuation coefficients of 5–10% between the XCOM and Chantler, while the differences for the IBA Handbook dataset can be larger (up to 40% and greater) at high X‐ray energies. At this time, we recommend the dataset of Chantler as it is more recent, and the synchrotron experimental results seem to favour it over the older XCOM and IBA Handbook data. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号