首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 812 毫秒
1.
The migration behaviour of isoquinoline, quinoline, and methyl derivatives of quinoline in different capillary electrophoretic modes has been systematically investigated. Optimised separation conditions were established by varying the key parameters (solvent, pH, temperature, surfactant concentration, core phase) for aqueous and non‐aqueous capillary zone electrophoresis (NACE), micellar electrokinetic chromatography (MEKC) with anionic or non‐ionic micelles (SDS, Brij 35), and microemulsion electrokinetic chromatography (MEEKC) with charged or uncharged microemulsion droplets. A separation of all quinolines could be achieved by MEEKC with charged droplets, by MEKC or by formamide‐based NACE. Comparing the separations with respect to separation selectivity, substantial changes in migration order could be observed between the different techniques. Regarding separation efficiency, the number of theoretical plates and limits of detection (LOD) have been compared. The best LODs were achieved using SDS as surfactant in MEKC, followed by MEEKC.  相似文献   

2.
La S  Kim A  Kim JH  Choi OK  Kim KR 《Electrophoresis》2002,23(7-8):1080-1089
An efficient capillary electrophoretic (CE) profiling and screening system based on dual modes of capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MEKC) was developed for the simultaneous determination of 23 nonprotein amino acids (NPAAs) and 4 protein amino acids with aromatic moiety. It involves separation by an uncoated fused-silica capillary under phosphoric acid buffer in CZE mode and by another uncoated fused-silica capillary under neutral sodium dihydrogen phosphate buffer containing sodium dodecyl sulfate in MEKC mode. Migration orders of the amino acids studied on the two separation modes under each optimum condition were very different. The repeatability of migration times measured by the CZE and MEKC was found to be better than 4.8 and 3.4%, respectively, thereby enabling to cross-check the identification of each amino acid. The method linearity and limit of detection of the CZE for each amino acid were found to be adequate for the assay of aromatic amino acids. When the present CE profiling and screening analysis in dual modes was applied to plant seeds, NPAAs such as mimosine from Mimosa pudica Linné, and 2-phenylglycine from Lindera erythrocarpa Makino were positively detected along with tryptophan, phenylalanine and tyrosine.  相似文献   

3.
The electrophoretic behaviour of ionizable and neutral alkylxanthines commonly used in pharmaceutical preparations was studied. The performance of various separation modes including capillary zone electrophoresis (CZE), cyclodextrin electrokinetic chromatography, and micellar electrokinetic chromatography (MEKC) with either sodium dodecyl sulfate (SDS) or bile salts as surfactants, was assessed. CZE in an alkaline medium successfully separates ionizable xanthines and dyphylline. The addition of carboxymethyl-β-cyclodextrin to the background electrolyte allows only partial resolution of neutral xanthines. Based on MEKC results, bile salts exhibit more discrimination ability than SDS to separate similar xanthines. The best results are provided by taurodeoxycholic acid, which ensures baseline separation of xanthines.  相似文献   

4.
Cugat MJ  Borrull F  Calull M 《The Analyst》2000,125(12):2236-2240
We investigated the separation of a test mixture of nine substituted and unsubstituted naphthalenedisulfonate isomers by capillary electrophoresis with a UV diode array detector. In particular, we focused on how the composition of the running buffer affected the separation selectivity. When capillary zone electrophoresis was carried out, the best results were obtained when organic solvents such as ethanol or propan-2-ol were added. Eight peaks were baseline separated but in no case were all the unsubstituted isomers separated. Therefore, capillary electrophoretic separation of the compounds was examined in the presence of micellar agents, such as sodium dodecyl sulfate, polyethylene glycol dodecyl ether (Brij 35) and cetyltrimethylammonium bromide. All the substituted isomers and two of the unsubstituted isomers were well resolved within 20 min by micellar electrokinetic capillary chromatography when Brij 35 was used as micellar agent. Separations were reproducible, in terms of peak area and migration time, under these conditions.  相似文献   

5.
The separation of mixtures of free genetically coded amino acids by capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC) using UV and refractometric detection was studied. Mixtures of 16 and 14 amino acids were separated by CZE and MEKC, respectively.  相似文献   

6.
The usefulness of capillary electrophoresis (CE) with diode array detection for the profiling of Propolis, a hive product, is investigated. Water extracts of Propolis were analyzed with both capillary zone electrophoresis (CZE) at pH 7.0 and 9.3, and micellar electrokinetic chromatography (MEKC) with sodium dodecyl sulfate at pH 9.3. Characteristic profiles were obtained and several organic acids and preservatives could be identified by means of library comparison of the recorded UV spectra combined with addition of reference compounds to the extracts. The selectivity of the CZE and MEKC system differed considerably but the information obtained with both methods was similar. The dry residues of the water extraction were extracted with ethanol-water (70 : 30, v/v) and analyzed with the MEKC system to enable the separation of the more hydrophobic constituents of the Propolis samples. Complex profiles containing various well separated peaks were obtained allowing the identification of some interesting flavonoids. On the basis of the recorded CZE and MEKC profiles, the Propolis samples could be divided into two clearly different groups which are probably from a different origin.  相似文献   

7.
In this study, an online concentration method in micellar electrokinetic chromatography (MEKC) applying field-enhanced sample injection (FESI) mode was developed for the detection of aristolochic acids (AAs) in Chinese medicine preparations. AA-I and AA-II were baseline separated with high separation efficiency, and 100-fold enhancement of the detection sensitivity was achieved compared with those obtained from normal capillary zone electrophoresis (CZE) or simple MEKC method. The proposed method was successfully applied for the determination of AAs in Chinese medicine preparations.  相似文献   

8.
Sixteen synthetic chemical drugs, often found in adulterated Chinese medicines, were studied by capillary electrophoresis/UV absorbance (CE/UV) and capillary electrophoresis/electrospray ionization mass spectrometry (CE/ESI-MS). Only nine peaks were detected with CZE/UV, but on-line CZE/MS provided clear identification for most compounds. For a real sample of a Chinese medicinal preparation, a few adulterants were identified by their migration times and protonated molecular ions. For coeluting compounds, more reliable identification was achieved by MS/MS in selected reaction monitoring mode. Micellar electrokinetic chromatography (MEKC) using sodium dodecyl sulfate (SDS) provided better separation than capillary zone electrophoresis (CZE), and, under optimal conditions, fourteen peaks were detected using UV detection. In ESI, the interference of SDS was less severe in positive ion mode than in negative ion mode. Up to 20 mM SDS could be used in direct coupling of MEKC with ESI-MS if the mass spectrometer was operated in positive ion mode. Because of better resolution in MEKC, adulterants can be identified without the use of MS/MS.  相似文献   

9.
A capillary electrophoretic (CE) method was developed for the separation of diastereoisomers of a new human immunodeficiency virus (HIV) protease inhibitor TMC114. In total 16 isomers of this drug have been synthesized (eight pairs of enantiomers). We succeeded in the separation of the eight diastereoisomers, but no enantiomers could be separated. Because of the high similarity and water-insolubility of these isomers, the separation is a real challenge. Different CE modes were tried out: capillary zone electrophoresis (CZE), nonaqueous capillary electrophoresis (NACE), micellar electrokinetic capillary chromatography (MEKC), and microemulsion electrokinetic capillary chromatography (MEEKC). Only MEEKC offered resolution of these compounds.  相似文献   

10.
Wang XK  He YZ  Qian LL 《Talanta》2007,74(1):1-6
A simple and convenient method of micellar electrokinetic capillary chromatography (MEKC) using polyoxyethylene sorbitan monolaurate (Tween 20) to form single micelle and methanol as a buffer additive was introduced for the simultaneous determination of five polyphenols, including scopoletin, rutin, esculetin, chlorogenic acid and caffeic acid. A running buffer solution of pH 9.3, 20 mmol/L sodium tetraborate containing 64 mmol/L Tween 20 and 9% (v/v) methanol was adopted in the separation. Because rutin and esculetin were difficult to be separated by capillary zone electrophoresis (CZE) and SDS-based MEKC, Tween 20-based MEKC was adopted and the polyphenols were separated satisfactorily. The proposed method was used to determine the polyphenol components in the herbal medicine of Cortex fraxini. The separation mechanism of Tween 20-based MEKC for the polyphenols was discussed preliminarily.  相似文献   

11.
毛细管电泳(capillary electrophoresis,CE)作为一种强有力的手性分离技术,由于操作简单、试剂消耗少及柱效高等优点,受到广泛关注,是近年来手性分离领域的研究热点.氨基酸是组成蛋白质的基本单元,且大多数氨基酸具有手性中心,手性氨基酸是生命体系的一个重要特征.具有手性中心的氨基酸,其对映体间的生物活性往往存在着较大的差异,因此,氨基酸的手性拆分对了解人体及动物生命活动起着举足轻重的作用.主要总结了近5年来毛细管电泳的3种分离模式(毛细管区带电泳、胶束电动毛细管色谱、毛细管电色谱)在氨基酸手性拆分中的发展和应用.  相似文献   

12.
The systematic optimization of capillary electrophoretic separations using a dynamic scouting optimum method-controlled weighted centroid variable size simplex algorithm is described. The factors affecting the efficiency of the separation are simultaneously considered during the optimization procedures. The established optimization method is applied to amino acid separation by capillary zone electrophoresis (CZE) with on-column indirect UV detection and to the separation of local anesthetics by micellar electrokinetic chromatography (MECC) with on-column UV detection. The optimization procedures include the pH and the background absorption electrolyte (BGAE) concentrations together with the applied voltage in the CZE separation of amino acids. The pH, the SDS concentrations together with the percentage of methanol are considered in the MECC separation of local anesthetics. Two methods, i.e., the Long Coefficient and Uniform Design Table, are used to define the start vertexes during the optimization procedure and similar final experimental conditions for the separations are achieved. Thirteen native amino acids are baseline separated by CZE and 4 local anesthetics are satisfactorily separated by MECC.  相似文献   

13.
This study details the development and validation of an optimized method with micellar electrokinetic chromatography for the analysis of clindamycin. The method uses a mixed micellar phase containing anionic sodium dodecylsulfate (SDS) and non ionic Brij 35 on an untreated fused-silica capillary. The influences of buffer concentration, pH, SDS, Brij 35 and organic modifier were investigated. Special attention was given to the role of the non ionic Brij 35 in the mixed micellar system. Optimization with a central composite design resulted in optimal separation conditions: background electrolyte containing 25 mM sodium tetraborate pH 7.75, 90 mM SDS, 14 mM Brij 35 and 21% acetonitrile. The applied voltage was 15 kV and the capillary temperature 15 degrees C. The method was robust and gave good linearity and repeatability. The limits of detection and quantitation were 0.05 and 0.15%, respectively, relative to a 2.5 mg/ml clindamycin solution. Two commercial bulk products were analysed with this system.  相似文献   

14.
With the implementation of recombinant DNA technology in the pharmaceutical industry, some synthetic insulins have been developed in order to improve the therapy of diabetes. These analogues differ only slightly in the amino acid sequence, therefore displaying a great challenge for analytical chemistry. Within the work presented in this paper, capillary zone electrophoresis (CZE), micellar electrokinetic chromatography (MEKC) with sodium dodecylsulphate (SDS) as micelle-forming agent, and microemulsion electrokinetic chromatography (MEEKC) with microemulsions consisting of SDS, n-octane and 1-butanol were investigated for the separation of human insulin and five synthetic analogues. Best results were achieved with a solvent-modified MEKC system consisting of 100 mM sodium dodecyl sulphate and 15% acetonitrile in 10 mM borate buffer (pH 9.2). A similar system based on perfluorooctanoic acid as micelle-forming agent in ammonium acetate (pH 9.2) was successfully employed for the hyphenation with a quadrupole/time-of-flight mass spectrometer via a sheath-flow interface. In this case, detection limits at 10 mg/L could be achieved.  相似文献   

15.
非水胶束电动色谱分离邻苯二甲酸酯类化合物   总被引:2,自引:0,他引:2  
非水胶束电动色谱(NAMEKC)兼具非水毛细管电泳的优点和胶束电动色谱的分离机制,尤其适于对强疏水性化合物进行分离分析。在以甲酰胺为非水溶剂的电泳介质中,采用十二烷基硫酸钠(SDS)形成胶束相,开展NAMEKC方法的研究。通过添加水溶液、调节水溶液酸度、添加有机溶剂、改变SDS浓度等操作条件的考察,在15 min 内实现了3种美国环保局优先监测的污染物——邻苯二甲酸二甲酯、邻苯二甲酸二乙酯、邻苯二甲酸二丁酯的分离。分离度最小者为1.5,检测限优于3.04 mmol/L(以信噪比为3计)。3种典型的强疏水性物质的成功分离,显示出NAMEKC方法在分离疏水性物质方面的优势,扩展了NAMEKC在电中性有机物分析中的应用。  相似文献   

16.
Different capillary electromigration techniques were employed to resolve geometrical isomers of sorbic acid, decadienoic acid, and ethyl sorbate. Since these substances differ in their polarity, shape, and size, various electromigration approaches were investigated to separate the four geometrical isomers of each compound. With capillary electrophoresis (CE) modified with a cyclodextrin (β‐CD) the four isomers of sorbic acid were separated using a buffer that consists of 60 mM tetraborate and 8 mg/mL β‐CD. The separation of decadienoic acid geometrical isomers was not possible, even at elevated tetraborate and cyclodextrin concentrations. The four isomers of decadienoic acid were successfully separated using micellar electrokinetic chromatography (MEKC) with a buffer consisting of 30 mM tetraborate and 100 mM SDS and microemulsion electrokinetic chromatography (MEEKC). Ethyl sorbate is the least polar of all the studied substances and its isomers could not be separated by MEKC or MEEKC. The resolution was improved and isomers were fully separated using capillary electrochromatography (CEC) with ODS stationary phase and a mobile phase consisting of 10 mM boric acid in 50% acetonitrile. Minor differences in the polarity and the shape of isomers and high resolving power of the applied techniques were sufficient for separation of very similar compounds. We have shown that versatile electromigration techniques can be applied for separation of geometrical isomers of dienoic acids and their esters.  相似文献   

17.
A comparison of separations conducted in sodium dodecyl sulfate (SDS) and SDS modified with Brij 35 indicates that selectivity, in Micellar Electrokinetic Chromatography (MEKC), is governed by the composition of the micellar phase. Beyond selectivity optimization, resolution may be improved by increasing efficiency or decreasing electroosmotic flow. Of these approaches, increasing capillary length (to improve efficiency) should be a more time effective means of improving separation.  相似文献   

18.
The capillary electrophoretic (CE) separation of the enantiomers of three binaphthyl compounds is investigated. Several CE modes such as cyclodextrin (CD) modified capillary zone electrophoresis (CZE) (CD-CZE), micellar electrokinetic chromatography (MEKC), cyclodextrin electrokinetic chromatography (CD-EKC), etc. are employed for the simultaneous enantiomer separation of the three solutes. The successful separation was achieved by combining two modes, in other words by using more than two chiral selectors. A development of the CE enantiomer separation is demonstrated for the binaphthyl compounds. The enantioselectivity of binaphthyl compounds is alo briefly discussed.  相似文献   

19.
The systematic optimization of capillary electrophoretic separations using a dynamic scouting optimum method-controlled weighted centroid variable size simplex algorithm is described. The factors affecting the efficiency of the separation are simultaneously considered during the optimization procedures. The established optimization method is applied to amino acid separation by capillary zone electrophoresis (CZE) with on-column indirect UV detection and to the separation of local anesthetics by micellar electrokinetic chromatography (MECC) with on-column UV detection. The optimization procedures include the pH and the background absorption electrolyte (BGAE) concentrations together with the applied voltage in the CZE separation of amino acids. The pH, the SDS concentrations together with the percentage of methanol are considered in the MECC separation of local anesthetics. Two methods, i.e., the Long Coefficient and Uniform Design Table, are used to define the start vertexes during the optimization procedure and similar final experimental conditions for the separations are achieved. Thirteen native amino acids are baseline separated by CZE and 4 local anesthetics are satisfactorily separated by MECC. Received: 10 November 1997 / Revised: 19 January 1998 / Accepted: 24 January 1998  相似文献   

20.
A tendency to an increase in migration times was observed when different water-soluble vitamins were analysed repeatedly in pharmaceutical preparations by capillary electrophoresis. In order to better understand the origin of this effect, the influence of the vitamins and the excipients, such as cellulose derivatives, was investigated. These studies indicated that the increase in analyte migration times was most probably due to the adsorption of different kinds of constituents to the capillary wall. Different rinsing procedures were tested in order to eliminate these unfavourable effects. A rinse of the capillary with a 25 mM sodium dodecyl sulfate (SDS) solution in the running buffer between successive runs was found to be particularly effective when the analysis was performed by free solution capillary zone electrophoresis (CZE). When the vitamins were determined by micellar electrokinetic chromatography (MEKC) using SDS as surfactant, a short capillary rinse with the running buffer was sufficient to obtain reproducible migration times. The CZE and MEKC methods developed were validated and compared. Both methods could be applied to the determination of water-soluble vitamins in different multivitamin formulations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号