首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) and ion trap mass spectrometry have been used to study the fragmentation behavior of native peptides and peptide derivatives prepared for de novo sequencing applications. Sulfonic acid derivatized peptides were observed to fragment more extensively and up to 28 times more efficiently than the corresponding native peptides. Tandem mass spectra of native peptides containing aspartic or glutamic acids are dominated by cleavage on the C-terminal side of the acidic residues. This significantly limits the amount of sequence information that can be derived from those compounds. The MS/MS spectra of native tryptic peptides containing oxidized Met residues show extensive loss of CH(3)SOH and little sequence-specific fragmentation. On the other hand, the tandem mass spectra of derivatized peptides containing Asp, Glu and oxidized Met show much more uniform fragmentation along the peptide backbone. The AP-MALDI tandem mass spectra of some derivatized peptides were shown to be qualitatively very similar to the corresponding vacuum MALDI postsource decay mass spectra, which were obtained on a reflector time-of-flight instrument. However, the ion trap mass spectrometer offers several advantages for peptide sequencing relative to current reflector time-of-flight instruments including improved product ion mass measurement accuracy, improved precursor ion selection and MS(n). These latter capabilities were demonstrated with solution digests of model proteins and with in-gel digests of 2D-gel separated proteins.  相似文献   

2.
Digests from ten gel bands containing low abundance proteins were analyzed by both matrix-assisted laser desorption/ionization ion trap (MALDI-IT) and matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) methods. MALDI-TOF techniques were able to identify only one protein from all 10 gel bands, while MALDI-IT identified eight proteins from the same 10 bands. The ability to perform MS/MS experiments with a MALDI-IT instrument leads to protein identifications based on both peptide molecular mass and sequence information, and is much less prone to errors and uncertainties introduced by peptide fingerprinting methodologies in which protein identification is based on peptide molecular masses alone.  相似文献   

3.
Quadrupole ion trap scanning parameters for performing bottom-up proteomics in a data-dependent fashion were evaluated on a Finnigan LCQ Deca mass spectrometer. Evaluation of parameters such as the number of averaged full scans, the number of averaged MS/MS scans, and ion injection times were necessary for acquiring high quality MS/MS spectra that yield favorable b and y ion coverage and high correlation to proteins using database searching algorithms. In this study, we demonstrated how the duty cycle of the mass spectrometer affects the number of peptides that can be successfully identified by SEQUEST using a model system of tryptic BSA peptides to mimic a typical complex mixture associated with bottom-up proteomics. The number of averaged scans and the duration of ion accumulation in the trap had a significant effect on the quality of acquired MS/MS spectra. For example, by increasing the ion injection time from 500 ms to 600 ms, peptide HLVDEPQNLIK improved from being improperly identified to being correctly identified with a SEQUEST cross-correlation score of 3.60. As a result of these experiments, we have devised the following set of ion trap parameters for performing bottom-up proteomics analysis in our laboratory: Three averaged full scans, five averaged MS/MS scans, and a maximum ion injection time of 600 ms.  相似文献   

4.
Atmospheric pressure matrix-assisted laser desorption/ionisation quadrupole ion trap (AP-MALDI/QIT) mass spectrometry has been investigated for the analysis of polyethylene glycol (PEG 1500) and a hyperbranched polymer (polyglycidol) in the presence of alkali-metal salts. Mass spectra of PEG 1500 obtained at atmospheric pressure showed dimetallated matrix/analyte adducts, in addition to the expected alkali-metal/PEG ions, for all matrix/alkali-metal salt combinations. The relative intensities of the desorbed ions were dependent on the matrix, the alkali-metal salt added to aid cationisation and the ion trap interface conditions [capillary temperature, in-source collisionally-induced dissociation (CID)]. These data indicate that the adducts are rapidly stabilised by collisional cooling enabling them to be transferred into the ion trap. Experiments using identical sample preparation conditions were carried out on a vacuum MALDI time-of-flight (ToF) mass spectrometer. In all cases, vacuum MALDI-ToF spectra showed only alkali-metal/PEG ions and no matrix/analyte adducts. The tandem mass spectrometry (MS/MS) capability of the ion trap has been demonstrated for a lithiated polyglycol yielding a rich fragment-ion spectrum. Analysis of the hyperbranched polymer polyglycidol by AP-MALDI/QIT reveals the characteristic ion series for these polymers as also observed under vacuum MALDI-ToF conditions.  相似文献   

5.
A comparative analysis of protein identification for a total of 162 protein spots separated by two-dimensional gel electrophoresis from two fully sequenced archaea, Methanococcus jannaschii and Pyrococcus furiosus, using MALDI-TOF peptide mass mapping (PMM) and mu LC-MS/MS is presented. 100% of the gel spots analyzed were successfully matched to the predicted proteins in the two corresponding open reading frame databases by mu LC-MS/MS while 97% of them were identified by MALDI-TOF PMM. The high success rate from the PMM resulted from sample desalting/concentrating with ZipTip(C18) and optimization of several PMM search parameters including a 25 ppm average mass tolerance and the application of two different protein molecular weight search windows. By using this strategy, low-molecular weight (<23 kDa) proteins could be identified unambiguously with less than 5 peptide matches. Nine percent of spots were identified as containing multiple proteins. By using mu LC-MS/MS, 50% of the spots analyzed were identified as containing multiple proteins. mu LC-MS/MS demonstrated better protein sequence coverage than MALDI-TOF PMM over the entire mass range of proteins identified. MALDI-TOF and PMM produced unique peptide molecular weight matches that were not identified by mu LC-MS/MS. By incorporating amino acid sequence modifications into database searches, combined sequence coverage obtained from these two complimentary ionization methods exceeded 50% for approximately 70% of the 162 spots analyzed. This improved sequence coverage in combination with enzymatic digestions of different specificity is proposed as a method for analysis of post-translational modification from 2D-gel separated proteins.  相似文献   

6.
Capillary high-performance liquid chromatography has been coupled on-line with an ion trap storage/reflectron time-of-flight mass spectrometer to perform tandem mass spectrometry for tryptic peptides. Selection and fragmentation of the precursor ions were performed in a three-dimensional ion trap, and the resulting fragment ions were pulsed out of the trap into a reflectron time-of-flight mass spectrometer for mass analysis. The stored waveform inverse Fourier transform waveform was applied to perform ion selection and an improved tickle voltage optimization scheme was used to generate collision-induced dissociation. Tandem mass spectra of various doubly charged tryptic peptides were investigated where a conspicuous y ion series over a certain mass range defined a partial amino acid sequence. The partial sequence was used to determine the identity of the peptide or even the protein by database search using the sequence tag approach. Several peptides from tryptic digests of horse heart myoglobin and bovine cytochrome c were selected for tandem mass spectrometry (MS/MS) where it was demonstrated that the proteins could be identified based on sequence tags derived from MS/MS spectra. This approach was also utilized to identify protein spots from a two-dimensional gel separation of a human esophageal adenocarcinoma cell line.  相似文献   

7.
2-DE combined with LC-MS/MS has become a routine, reliable protein separation and identification technology for proteome analysis. The demand for large-scale protein identifications after 2-DE separation requires a sensitive and high-throughput LC-MS/MS method. In this report, a simple, splitless, fully automated capillary LC-MS/MS system was described for the large-scale identification of proteins from gels stained with either silver or CBB. The gel samples were digested and peptides were extracted using an in-gel digestion workstation. The peptides were automatically introduced into a capillary column by an autosampler connected to an HPLC pump. A nanoLC pump was then used to deliver the gradient and elute the peptides from the capillary column directly into an LCQ IT mass spectrometer. Neither a peptide trapping setting nor a flow split is needed in this simple setup. The collected MS/MS spectra were then automatically searched by SEQUEST, and filtered and organized by DTASelect. Hundreds of silver-stained or CBB-stained Shewanella oneidensis, Geobacter sulfurreducens, and Geobacter metallireducens proteins separated by denaturing or nondenaturing 2-DE were digested and routinely analyzed using this fully automated muLC-MS/MS system. High peptide hits and sequence coverage were achieved for most CBB-stained gel spots. About 75% of the spots were found to contain multiple proteins. Although silver staining is not commonly thought to be optimal for MS analysis, protein identifications were successfully obtained from silver-stained 2-DE spots detected using methods with and without formaldehyde for protein fixation.  相似文献   

8.
The atmospheric pressure matrix-assisted laser desorption/ionization with ion trap mass spectrometry (AP-MALDI-ITMS) was investigated for its ability to analyse plant-derived oligosaccharides. The AP-MALDI-ITMS was able to detect xylooligosaccharides (XOS) with chain length of up to ten xylopyranosyl residues. Though the conventional MALDI–time-of-flight/mass spectrometry (TOF/MS) showed better sensitivity at higher mass range (>m/z 2,000), the AP-MALDI-ITMS seems to be more suitable for detection of acetylated XOS, and the measurement also corresponded better than the MALDI-TOF/MS analysis to the actual compositions of the pentose- and hexose-derived oligosaccharides in a complex sample. The structures of two isomeric aldotetrauronic acids and a mixture of acidic XOS were elucidated by AP-MALDI-ITMS using multi-stages mass fragmentation up to MS3. Thus, the AP-MALDI-ITMS demonstrated an advantage in determining both mass and structures of plant-derived oligosaccharides. In addition, the method of combining the direct endo-1,4-β-d-xylanase hydrolysis of plant material, and then followed by AP-MALDI-ITMS detection, was shown to recognize the substitution variations of glucuronoxylans in hardwood species and in Arabidopsis thaliana. To our knowledge, this is the first report to demonstrate the acetylation of glucuronoxylan in A. thaliana. The method, which requires only a small amount of plant material, such as 1 to 5 mg for the A. thaliana stem material, can be applied as a high throughput fingerprinting tool for the fast comparison of glucuronoxylan structures among plant species or transformants that result from in vivo cell wall modification.  相似文献   

9.
The analysis of complex biological peptide mixtures by tandem mass spectrometry (MS/MS) produces a huge body of collision-induced dissociation (CID) MS/MS spectra. Several methods have been developed for identifying peptide-spectrum matches (PSMs) by assigning MS/MS spectra to peptides in a database. However, most of these methods either do not give the statistical significance of PSMs (e.g., SEQUEST) or employ time-consuming computational methods to estimate the statistical significance (e.g., PeptideProphet). In this paper, we describe a new algorithm, RT-PSM, which can be used to identify PSMs and estimate their accuracy statistically in real time. RT-PSM first computes PSM scores between an MS/MS spectrum and a set of candidate peptides whose masses are within a preset tolerance of the MS/MS precursor ion mass. Then the computed PSM scores of all candidate peptides are employed to fit the expectation value distribution of the scores into a second-degree polynomial function in PSM score. The statistical significance of the best PSM is estimated by extrapolating the fitting polynomial function to the best PSM score. RT-PSM was tested on two pairs of MS/MS spectrum datasets and protein databases to investigate its performance. The MS/MS spectra were acquired using an ion trap mass spectrometer equipped with a nano-electrospray ionization source. The results show that RT-PSM has good sensitivity and specificity. Using a 55,577-entry protein database and running on a standard Pentium-4, 2.8-GHz CPU personal computer, RT-PSM can process peptide spectra on a sequential, one-by-one basis in 0.047 s on average, compared to more than 7 s per spectrum on average for Sequest and X!Tandem, in their current batch-mode processing implementations. RT-PSM is clearly shown to be fast enough for real-time PSM assignment of MS/MS spectra generated every 3 s or so by a 3D ion trap or by a QqTOF instrument.  相似文献   

10.
The potential of electrospray tandem mass spectrometry using a quadrupole-time-of-flight tandem mass spectrometer was evaluated for the identification of two unknown proteins from one-dimensional polyacrylamide gel electrophoresis (1-D-PAGE). Two proteins from cellular cultures of mammary epithelia were purified by 1D-PAGE. Their identification was achieved using peptide sequence tags generated by LC/Q-TOF-MS/MS, whereas MALDI-TOF mass mapping failed for these proteins obtained from simple 1D-PAGE separation.  相似文献   

11.
Accurately measured peptide masses can be used for large-scale protein identification from bacterial whole-cell digests as an alternative to tandem mass spectrometry (MS/MS) provided mass measurement errors of a few parts-per-million (ppm) are obtained. Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) routinely achieves such mass accuracy either with internal calibration or by regulating the charge in the analyzer cell. We have developed a novel and automated method for internal calibration of liquid chromatography (LC)/FTICR data from whole-cell digests using peptides in the sample identified by concurrent MS/MS together with ambient polydimethylcyclosiloxanes as internal calibrants in the mass spectra. The method reduced mass measurement error from 4.3 +/- 3.7 ppm to 0.3 +/- 2.3 ppm in an E. coli LC/FTICR dataset of 1000 MS and MS/MS spectra and is applicable to all analyses of complex protein digests by FTICRMS.  相似文献   

12.
Current analytical techniques in protein identification by mass spectrometry are based on the generation of peptide mass maps or sequence tags that are idiotypic for the protein sequence. This work reports on the development of the use of mass spectrometric methods for protein identification in research on metabolic pathways of a genetically modified strain of the baker's yeast Saccharomyces cerevisiae. This study describes the use of matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass mapping and liquid chromatography/quadrupole time-of-flight electrospray ionization tandem mass spectrometry (LC/Q-TOF-ESI-MS/MS) sequence tag analysis in identification of yeast proteins separated by two-dimensional polyacrylamide gel electrophoresis (2D-PAGE). The spots were selected for analysis in order to collect information for future studies, to cover the whole pI range from 3 to 10, and to evaluate information from spots of different intensities. Mass mapping as a rapid, high-throughput method was in most cases sensitive enough for identification. LC/MS/MS was found to be more sensitive and to provide more accurate data, and was very useful when analyzing small amounts of sample. Even one sequence tag acquired by this method could be enough for unambiguous identification, and, in the present case, successfully identified a point mutation.  相似文献   

13.
An algorithm for interpretation of product ion spectra of peptides generated from ion trap mass spectrometry is developed for de novo amino acid sequencing of peptides for the purpose of protein identification. It is based on a multi-pass analysis of product ion data using a rigorous data extraction and sequence interpretation protocol in the initial pass. The extraction/interpretation algorithm becomes more relaxed in subsequent passes, considering more of the fragment ions, and potentially more sequence candidates. The possible peptide sequences generated by the algorithm are scored according to those sequences which best explain the fragment ion spectrum. These sequences are searched against a protein database using a BLAST search engine to find likely protein candidates. The method is also suitable for locating and determining protein modifications, and can be applied to de novo interpretation of peptide fragment ions in the tandem mass (MS/MS) spectrum produced from a mixture of two peptides having similar nominal mass, but different sequences. Using a known protein, bovine serum albumin, as an example, it is illustrated that this method is rapid and efficient for MS/MS spectral interpretation. This method combined with BLAST programs is then applied to search homologies and to generate information on post-translational modifications of an unknown protein isolated from shark cartilage that does not have a complete genome or proteome database.  相似文献   

14.
A novel method for peptide sequencing by matrix-assisted laser desorption/ionization mass spectrometry with a time-of-flight/time-of-flight analyzer (MALDI-TOF/TOF) is presented. A stable isotope label introduced in the peptide N-terminus by derivatization, using a 1:1 mixture of acetic anhydride and deuterated acetic anhydride, allows for easy and unambiguous identification of ions belonging either to the N- or the C-terminal ion series in the product ion spectrum, making sequence assignment significantly simplified. The good performance of this technique was shown by successful sequencing of the contents of several peptide maps. A similar approach was recently applied to nanoelectrospray ionization (nanoESI) and nano-liquid chromatography/tandem mass spectrometry (LC/MS/MS). The MALDI-TOF/TOF technique allows for fast, direct sequencing of modified peptides in proteomics samples, and is complementary to the nanoESI and nanoLC/MS/MS approaches.  相似文献   

15.
Liquid chromatography/mass spectrometry (LC/MS) peptide maps have become a basic tool for characterizing proteins of biological and pharmaceutical interest. The ability to generate reproducible maps with high protein sequence coverage is a central goal of methods development. We have applied a recently developed analytical approach (termed LC/MS(E)) to LC/MS peptide mapping. Using the LC/MS(E) approach, the mass detector alternates between a low-energy scanning mode (MS) for accurate mass peptide precursor identification, and an elevated-energy mode (MS(E)) for generation of accurate mass multiplex peptide fragmentation data. In this paper, we evaluate this analytical approach against a tryptic digest of yeast enolase. From the low-energy data, high peptide map coverage (98% of sequence from peptides >3 amino acids) was reproducibly obtained. The MS signal for essentially equimolar peptides varied over 2 orders of magnitude in intensity, and peptide intensities could be precisely and reproducibly measured. Using the temporal constraint that MS(E) peptide fragment ions exhibit chromatographic profiles that parallel the precursor ions that generated them, we were able to produce accurate mass time-resolved MS/MS information for all enolase peptides with sufficient abundance to produce a detectable fragment ion.  相似文献   

16.
For mass spectrometry-based diagnostics of microorganisms, matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is currently routinely used to identify urinary tract pathogens. However, it requires a lengthy culture step for accurate pathogen identification, and is limited by a relatively small number of available species in peptide spectral libraries (≤3329). Here, we propose a method for pathogen identification that overcomes the above limitations, and utilizes the MALDI-TOF/TOF MS instrument. Tandem mass spectra of the analyzed peptides were obtained by chemically activated fragmentation, which allowed mass spectrometry analysis in negative and positive ion modes. Peptide sequences were elucidated de novo, and aligned with the non-redundant National Center for Biotechnology Information Reference Sequence Database (NCBInr). For data analysis, we developed a custom program package that predicted peptide sequences from the negative and positive MS/MS spectra. The main advantage of this method over a conventional MALDI-TOF MS peptide analysis is identification in less than 24 h without a cultivation step. Compared to the limited identification with peptide spectra libraries, the NCBI database derived from genome sequencing currently contains 20,917 bacterial species, and is constantly expanding. This paper presents an accurate method that is used to identify pathogens grown on agar plates, and those isolated directly from urine samples, with high accuracy.  相似文献   

17.
Atmospheric pressure laser desorption/ionization on porous silicon   总被引:3,自引:0,他引:3  
A recently developed commercial atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) source (MassTech, Inc.) was modified to adopt commercially available DIOS plates (Mass Consortium Corp.) for the studies of laser desorption from the surface of porous silicon under atmospheric pressure conditions. The feasibility of atmospheric pressure laser desorption/ionization from the surface of porous silicon (AP-DIOS) was demonstrated. The advantages of this new AP-DIOS technique include reasonably good sensitivity (subpicomole range for standard peptide mixtures), simplicity of sample preparation, uniformity of target spots and the absence of matrix peaks in the spectra. The AP-DIOS source was interfaced with a commercial ion trap (LCQ Classic, Thermo Finnigan) which additionally provides a unique MS(n) capability. The AP-DIOS spectrum of 250 fmol of unseparated tryptic digest of bovine serum albumin (BSA) was compared with that of AP-MALDI for the same compound. AP-DIOS offers significantly better coverage for the digest components in the mass range 200-1000 Da. The combined data of both techniques enabled us to nearly double the number of matched peaks in BSA digest analysis compared with AP-DIOS or AP-MALDI analysis separately.  相似文献   

18.
A sensitive, integrated top-down liquid chromatography/mass spectrometry (LC/MS) approach, suitable for the near complete characterization of specific proteins in complex protein mixtures, such as inclusion bodies of an E. coli lysate, has been successfully developed using a hybrid linear ion trap/Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. In particular, human growth hormone (hGH) (200 fmol) was analyzed with high sequence coverage (>95%), including the sites of disulfide linkages. The high mass accuracy and resolution of the FTICR mass spectrometer was used to reveal high charge state ions of hGH (22 kDa). The highly charged intact protein ions (such as the 17+ species) were captured and fragmented in the linear ion trap cell. The fragment ions from MS/MS spectra were then successfully analyzed in the FTICR cell in an on-line LC/MS run. Peptide fragments from the N-terminal and C-terminal regions, as well as large interior fragments, were captured and identified. The results allowed the unambiguous assignment of disulfide bonds Cys53-Cys165 and Cys182-Cys189, indicative of proper folding of hGH. The disulfide bond assignments were also confirmed by analysis of the tryptic digest of a sample of hGH purified from inclusion bodies. On-line LC/MS with the linear ion trap/FTICR yields high mass accuracy in both the MS and MS/MS modes (within 2 ppm with external calibration). The approach should prove useful in biotechnology applications to characterize correctly folded proteins, both in the early protein expression and the later processed stages, using only a single automated on-line LC/MS top-down method.  相似文献   

19.
In this study, we utilized a multidimensional peptide separation strategy combined with tandem mass spectrometry (MS/MS) for the identification of proteins in human serum. After enzymatically digesting serum with trypsin, the peptides were fractionated using liquid-phase isoelectric focusing (IEF) in a novel ampholyte-free format. Twenty IEF fractions were collected and analyzed by reversed-phase microcapillary liquid chromatography (microLC)-MS/MS. Bioinformatic analysis of the raw MS/MS spectra resulted in the identification of 844 unique peptides, corresponding to 437 proteins. This study demonstrates the efficacy of ampholyte-free peptide autofocusing, which alleviates peptide losses in ampholyte removal strategies. The results show that the separation strategy is effective for high-throughput characterization of proteins from complex proteomic mixtures.  相似文献   

20.
Cyclic peptides have come under scrutiny as potential antimicrobial therapeutic agents. Combinatorial split-and-pool synthesis of cyclic peptides can afford single compound per well libraries for antimicrobial screening, new lead identification, and construction of quantitative structure-activity relationships (QSAR). Here, we report a new sequencing protocol for rapid identification of the members of a cyclic peptide library based on automated computer analysis of mass spectra, obviating the need for library encoding/decoding strategies. Furthermore, the software readily integrates with common spreadsheet and database packages to facilitate data visualization and archiving. The utility of the new MS-sequencing approach is demonstrated using sonic spray ionization ion trap MS and MS/MS spectrometry on a single compound per bead cyclic peptide library and validated with individually synthesized pure cyclic D,L-alpha-peptides.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号