首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A novel method for mapping the longitudinal relaxation time in a clinically acceptable time is developed based on a recent proposal [J.-J. Hsu, I.J. Lowe, Spin-lattice relaxation and a fast T1-map acquisition method in MRI with transient-state magnetization, J. Magn. Reson. 169 (2004) 270-278] and the speed of the spiral pulse sequence. The method acquires multiple curve-fitting samples with one RF pulse train. It does not require RF pulses of specific flip angles (e.g., 90 degrees or 180 degrees ), nor are the long recovery waiting time and the measurement of the magnetization at thermal equilibrium needed. Given the value of the flip angle, the curve fitting is semi-logarithmic and not computationally intensive. On a heterogeneous phantom, the average percentage difference between measurements of the present method and those of an inversion-recovery method is below 2.7%. In mapping the human brain, the present method, for example, can obtain four curve-fitting samples for five 128 x 128 slices in less than 3.2s and the results are in agreement with other studies in the literature.  相似文献   

2.
3.
核磁共振弛豫时间测量数据处理方法的讨论   总被引:1,自引:1,他引:1  
分析和讨论了在超小型核磁共振成像仪测量弛豫时间T1的数据处理方法中存在的问题,并提出了测量方法和数据拟合的改进方案.  相似文献   

4.
A novel method for the simultaneous, high-resolution measurement of the specific heat c and the thermal conductivity κ is presented. A new experimental setup has been developed with special emphasis on the elimination of systematic errors arising from radiative heat loss. A self-consistent data evaluation method is implemented which takes the effects of the sample geometry on c and κ properly into account. The measurements were performed over a broad temperature regime from 3 K up to room temperature on three compounds from the family of strongly correlated electron systems. The differences in their thermal properties and their highly sample-dependent sizes and shapes demonstrate the extended scope of the proposed method.  相似文献   

5.
The purpose of this communication is to describe a method for rapid and simultaneous determination of longitudinal (T1) and transversel (T2) relaxation times, based on a single continuous wave free precession (CWFP) experiment which employs RF pulses with a pi/2 flip angle. We analyze several examples, involving nuclei such as 1H, 31P, and 19F, where good agreement with T1 and T2 measurements obtained by traditional methods is apparent. We also compare with the more time-consuming steady-state free precession (SSFP) method of Kronenbitter and Schwenk where several experiments are needed to determine the optimum flip angle. The role of an inhomogeneous magnetic field on the observed decays and its effect upon the accuracy of relaxation times obtained by these methods is examined by comparing numerical simulations with experimental data. Possible sources of error and conditions to minimize its effects are described.  相似文献   

6.
Changes in longitudinal relaxation time (T1) and proton density (PD) are sensitive indicators of microstructural alterations associated with various central nervous system diseases as well as brain maturation and aging. In this work, we introduce a new approach for rapid and accurate high-resolution (HR) or ultra HR (UHR) mapping of T1 and apparent PD (APD) of the brain with correction of radiofrequency field, B1, inhomogeneities. The four-angle method (FAM) uses four spoiled-gradient recalled-echo (SPGR) images acquired at different flip angles (FA) and short repetition times (TRs). The first two SPGR images are acquired at low-spatial resolution and used to accurately map the active B1+ field with the recently introduced steady-state double angle method (SS-DAM). The estimated B1+ map is used in conjunction with the two other SPGR images, acquired at HR or UHR, to map T1 and APD. The method is evaluated with numerical, phantom, and in-vivo imaging measurements. Furthermore, we investigated imaging acceleration methods to further shorten the acquisition time. Our results indicate that FAM provides an accurate method for simultaneous HR or UHR mapping of T1 and APD in human brain in clinical high-field MRI. Derived parameter maps without B1+correction suffer from large inaccuracies, but this issue is well-corrected through use of the SS-DAM. Furthermore, the use of SPGR imaging with short TR and phased-array coil acquisition permits substantial imaging acceleration and enables robust HR or UHR T1 and APD mapping in a clinically acceptable time frame, with whole brain coverage obtained in less than 2 min or 5 min, respectively. The method exhibits high reproducibility and benefits from the use of the conventional SPGR sequence, available in all preclinical and clinical MRI machines, and very simple modeling to address a critical outstanding issue in neuroimaging.  相似文献   

7.
The effect of nitrogen-15 proton-driven spin diffusion on quantitative (15)N T(1) measurements in solid proteins is investigated, and the impact on the measurement of dynamic parameters is assessed. A simple model of exchange between neighboring nitrogens is used to reproduce the evolution of (15)N spin systems whose longitudinal relaxation rates and exchange rates are compatible with experimental measurements. We show that the induced error in the measured T(1) and its effect on the determination of dynamics parameters is likely to be less than the current experimental error. The use of deuterated protein samples is shown to have a small but sometimes visible effect, and may also considerably slow down or even suppress the exchange of magnetization due to spin diffusion.  相似文献   

8.
The use of chemical shift imaging for fat and water quantitation and differential measurement of relaxation times for the fat and water component is demonstrated using a hybrid technique. The efficacy of the imaging technique for fat and water quantitation has been tested by comparing the results of imaging to the results of volumetric measurements in phantoms with oil and water homogeneously mixed, fat extraction in ground meat of different grades, and biopsy in preliminary clinical studies. Good correlation is found between the fat and water content measured by imaging and that measured by other means except for the inability to differentiate unsaturated fat protons from water protons. Longitudinal (T1) and transverse (T2) relaxation times for water and fat are also shown to be measurable independently when fat and water signal are suppressed accordingly. The independently measured relaxation times correspond closely to those of the pure samples except that unsaturated protons give decreased water relaxation estimates.  相似文献   

9.
This paper describes an NMR method capable of determining the diffusion constant of a material within a few milliseconds and without the need of multiple scans. The method can be used with static or pulsed magnetic field gradients. It may be used to detect time-dependent processes, such as in chemical reactions, production monitoring, and medical MRI.  相似文献   

10.
Correlation of proton MR spectroscopy and diffusion tensor imaging   总被引:3,自引:0,他引:3  
Proton magnetic resonance spectroscopy ((1)H-MRS) provides indices of neuronal damage. Diffusion tensor imaging (DTI) relates to water diffusivity and fiber tract orientation. A method to compare (1)H-MRS and DTI findings was developed, tested on phantom and applied on normal brain. Point-resolved spectroscopy (T(R)/T(E)=1500/135) was used for chemical shift imaging of a supraventricular volume of interest of 8 x 8 x 2 cm(3) (64 voxels). In DTI, a segmental spin-echo sequence (T(R)/T(E)=5500/91) was used and slices were stacked to reproduce the slab used in MRS. The spatial distributions of choline and N-acetylaspartate (NAA) correlated to mean fractional anisotropy and apparent diffusion coefficient (ADC) for the inner 6 x 6=36 voxels defined in MRS, most notably NAA and ADC value (r=-.70, P<.00001; correlation across four subjects, 144 data pairs). This is the first association of neuron metabolite contents in volunteers with structure as indicated by DTI.  相似文献   

11.

Purpose

To present proton magnetic resonance spectroscopy and diffusion-weighted imaging (DWI) findings of central neurocytoma (CN).

Methods and Materials

Imaging findings of seven patients with the histopathological diagnosis of CN (five male and two female; age range, 21–28 years of age) were evaluated retrospectively. In addition to conventional magnetic resonance imaging features, we also assessed the metabolite ratios and tumor normalized apparent diffusion coefficient (NADC), which was calculated by dividing the tumor apparent diffusion coefficient (ADC) values by normal ADC. Approval from our institutional review board was obtained for this review.

Results

The tumor choline/creatine ratios were 5.17±2.38, while N-acetyl aspartate/choline and N-acetyl aspartate/creatine ratios were 0.33±0.15 and 1.84±1.38, respectively. On DWI, tumors had heterogeneous hyperintense appearances when compared with the contralateral parietal lobe white matter and tumor NADC values were 0.63±0.05.

Conclusion

Significantly increased choline/creatine and decreased N-acetyl aspartate/choline ratios with lower NADC values in CN resemble high-grade gliomas and complicate the diagnosis. Familarity its physiologic features would help to presurgical diagnosis of ventricular and exraventricular CNs.  相似文献   

12.
The multicomponent T2 relaxation in bovine nasal cartilage (BNC) was investigated by nuclear magnetic resonance spectroscopy using the Carr-Purcell-Meiboom-Gill (CPMG) sequence and microscopic magnetic resonance imaging (μMRI) method using a CPMG-SE imaging sequence. All experimental data were analyzed by the non-negative least square (NNLS) procedure. Only one T2 component was found in BNC by both experimental methods (about 113 and 170 ms before and after being enzymatically digested by trypsin). Several experimental and specimen-related factors were investigated in this study, and it was found that some of them could produce artificial multi-component T2, including the use of the standard MSME imaging sequence at certain imaging gradients.  相似文献   

13.
《Magnetic resonance imaging》1998,16(9):1049-1055
Spin-lattice (T1) relaxation times were measured by an inversion-recovery magnetic resonance imaging method with a slice-selective inversion pulse (SIP), a non-selective rectangular inversion pulse (RIP), or a B1-insensitive adiabatic inversion pulse (AIP). Data analysis either assumed perfect inversion (two-parameter fit) or allowed for imperfect inversion (three-parameter fit). Imperfect inversion pulses caused low T1 values in phantoms with a two-parameter fit, while three-parameter T1 estimates were accurate over the range 430–2670 ms. A difference of ∼10% between two-parameter and three-parameter T1 values in normal human brain tissue was attributed to B1 inhomogeneity with the slice-selective inversion pulse and rectangular inversion pulse, to the slice profile with the slice-selective inversion pulse, and to T2 effects for the adiabatic inversion pulse. Any T1 method that relies on accurate flip angles may have a significant systematic error in vivo. Phantom accuracy does not ensure accuracy in vivo, because phantoms may have a more homogeneous B1 field and a longer T2 than do biological samples.  相似文献   

14.
Phase-encoding to the longitudinal magnetization is implemented by adding encoding gradient pulses in the evolution period tau of the NMR pulse sequence 90 degrees+x-tau-90 degrees-x. This work focuses on the effect of the spin-lattice relaxation and its removal and on the constraint that the 90 degrees-x pulse can only transform the phase of the transverse magnetization partially to the longitudinal magnetization. Theoretical analysis shows that the encoded phase information and the spin-lattice relaxation effect are separable and the latter is identical in each repetition in collecting phase-encoding data. Thus the relaxation effect can be eliminated by subtracting a second data set whose phase information is inverted or by alternating the polarity of the relaxation contribution. From data with partial phase information, Fourier-transform image reconstruction results in mirror aliasing in which the two halves of the Fourier spectrum of positive and negative coordinates overlap. Removal of mirror aliasing requires imaging data of the orthogonal component. Nevertheless mirror aliasing is not necessarily a problem, depending on the subject of study. Phase-encoding to the longitudinal magnetization for spatial MRI and flow velocity mapping are demonstrated using the rotating ultra-fast imaging sequence (RUFIS).  相似文献   

15.
《Solid State Ionics》1988,31(3):215-220
A new experimental arrangement is presented which allows the simultaneous determination of the tracer diffusion coefficient and the mobility of alkali ions in glasses from a single sample. The basic idea is the study of tracer diffusion than electric field under special boundary conditions. The experimental procedure is described in detail and a mathematical analysis is given. As an example the experiment is applied to a commercial optical glass with high Na2O content.  相似文献   

16.
The vibrational relaxation time constant for theB v=0 vibrational level of XeCl* has been investigated by observing the coupling between theB v=1 andB v=0 vibrational levels under saturated lasing conditions. Based on this observation, estimates of the expected extraction efficiency from theB-state have been made.  相似文献   

17.
Measurements of proton T1 and T2 were performed on GdCl3 solutions (20 less than T2 less than 500 msec, 90 less than T1 less than 1000 msec) on large-bore NMR imaging systems operating at 1.0T and 1.5T. CPMG multi-echo (ME), multiple saturation recovery (MSR) and modified fast inversion recovery (MFIR) pulse sequences as well as a sequence that combines and interleaves T1 and T2 weighted data acquisition (which we call "multiple saturation-recovery multiple-echo" (MSRME) were used. The relaxation data are compared to those obtained on a small bore NMR spectrometer operated at 1.5T. T1 and T2 values for the solutions were found to be the same within 10% for the two fields. Reproducibility of measurements of T1, T2 and the unnormalized spin density of the solutions was better than 5%. Systematic errors, amenable to correction through calibration, are noted in the imager T1 and T2 values. T1 and T2 values for some typical neural tissues at 1.5T and body tissue at 1.0T for human volunteers were obtained and are tabulated.  相似文献   

18.
The accuracy of relaxation time measurements of spectroscopic inversion recovery and CPMG multi-echo pulse sequences together with ISIS and stimulated echo-pulse methods have been tested on a reference phantom (test object no. 5, of the EEC Concerted Research Project). For the measurements a Siemens Magnetom wholebody magnetic resonance scanner operating at 1.5 Tesla was used. For comparison six imaging pulse sequences for relaxation time measurements were tested on the same phantom. The spectroscopic pulse sequences all had an accuracy better than 10% of the reference values.  相似文献   

19.
A method for the automatic measurement of reverberation time is described. In order to reduce the influence of flutter a curve fitting method, based on integration of the decay curve, is applied. The method allows the reverberation time to be measured without subjective interactions, both in the field and in the laboratory. A comparison between various methods shows that the described method exhibits a high degree of reliability.  相似文献   

20.
A method is presented that allows real-time three-dimensional displacement maps to be obtained for deformable objects using a single color camera and a color fringe projector. The acquired images have speckle and fringe information embedded in them, which are separated using the R, G, and B color signals from a color CCD camera to permit the independent use of a two-dimensional digital image correlation to obtain the x- and y-direction displacements and fringe projection to obtain the displacement in the z direction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号