首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Coronary magnetic resonance angiography (MRA) acquired using steady-state free precession (SSFP) sequences tends to suffer from image artifacts caused by local magnetic field inhomogeneities. Flow- and gradient-switching-induced eddy currents are important sources of such phase errors, especially under off-resonant conditions. In this study, we propose to reduce these image artifacts by using a linear centric-encoding (LCE) scheme in the phase-encoding (PE) direction. Abrupt change in gradients, including magnitude and polarity between consecutive radiofrequency cycles, is minimized using the LCE scheme. Results from numeric simulations and phantom studies demonstrated that signal oscillation can be markedly reduced using LCE as compared to conventional alternating centric-encoding (ACE) scheme. The image quality of coronary arteries was improved at both 1.5 and 3.0 T using LCE compared to those acquired using ACE PE scheme (1.5 T: ACE/LCE=2.2+/-0.8/3.0+/-0.6, P=.02; 3.0 T: ACE/LCE=2.1+/-1.1/3.0+/-0.8, P=.01). In conclusion, flow- and eddy-currents-induced imaging artifacts in coronary MRA using SSFP sequence can be markedly reduced with LCE acquisition of PE lines.  相似文献   

2.
A new “bright blood” strategy, outflow refreshment imaging, is introduced in which a number of overlapping slices are excited in rapid succession. Flowing spins that refresh each overlapped slice portion contribute a bright signal. Additionally, static tissue in each non-overlapped slice portion also yields a bright signal. However, the flow/static contrast is comparable to that produced in inflow refreshment images, and angiograms can be generated by conventional maximum intensity projection processing. The dual ability to visualize angiograms and static tissue images is a major benefit of the strategy. Computer simulations of flow sensitivities and in vivo results are presented which compare the outflow and inflow refreshment imaging strategies.  相似文献   

3.
MRI techniques have been used to describe velum opening of French vowels. Data based on 18 joined axial slices of 4 mm thickness were recorded with four subjects. Differences in velum opening are calculated from areas measured in the tract between the lowered velum and the back pharynx wall. Results show that for all subjects, the back vowel / / has the smallest opening, while some variations are observed for the other vowels.  相似文献   

4.
A new pulse sequence designed for magnetic resonance imaging of the entire thoracic cavity is described. This sequence, called 3DPAUSE, is a rapid three-dimensional Fourier transform (3DFT) sequence with periodic pauses for breathing and additional rf pulses after each pause to restore the magnetization to steady-state before data acquisition resumes. Cardiac motion artifacts are effectively removed by signal averaging. Respiratory motion artifacts are removed by breath hold. Image artifacts caused by an inadequate number of pauses or by inappropriate placement of the pauses within a scan are shown, and ways to avoid these artifacts are discussed. 3DPAUSE provides the ability to acquire three-dimensional arrays in the thoracic cavity with minimal artifacts from respiratory and cardiac motions in a clinically reasonable time.  相似文献   

5.
We present a case report of a urethral diverticulum where magnetic resonance imaging suggested infected contents of the urethral diverticulum besides providing superb detail of periurethral anatomy. The critical clinical question was answered.  相似文献   

6.
Renal cortical and medullary spin-lattice (T1) relaxation times were measured at various time points over a period of 56 days following the administration of a single i.p. injection of 100 mg/kg 2-bromoethanamine hydrobromide (BEA), 200 mg/kg hexachloro-1,3-butadiene (HCBD) or 100 mg/kg puromycin aminonucleoside (PAN) to male Wistar rats. Administration of a single injection of HCBD caused a dramatic, immediate rise in the cortical T1 values above control values, and these levels remained elevated until, by Day 28 postinjection the levels were back to control values. Administration of BEA also caused an elevation in cortical T1 values, but in this case these values remained above control values for the rest of the study. The administration of PAN did not produce any significant increases in cortical T1 values until 14 days postinjection. The elevated T1 values remained above control values for the rest of the study. These increases observed in cortical T1 values appeared to be mirrored by decreases in medullary T1 values. Increases in cortical T1 values were accompanied by visual changes in the NMR images and enlargement of the kidneys. The histological findings were consistent with the NMR data, confirming that morphologically the tissues did show a full recovery by Day 28 in the HCBD-treated animals. This was not the case following injection of both BEA and PAN, where necrosis was not reversible and there was no recovery of the tissues.  相似文献   

7.
Longitudinal and transverse proton relaxation times were measured on pig tendon. For T1, dispersion curves and more accurate measurements at 20 MHz are presented. Values of T2 were obtained from CPMG pulse sequences, at 20 MHz. The dependence of relaxation times against the fiber-to-field angle was particularly investigated. Longitudinal relaxation rate was found to be almost orientation independent, and presented quadrupolar peaks between 1 and 4 MHz. On the contrary, transverse relaxation, that was well fitted by the sum of four exponentials, was highly orientation dependent. Deconvolution showed that the exponentials decaying most quickly are most orientation dependent. For those two fractions, a cross-relaxation model allowed explaining the fiber-to-field angle dependence, and the specially low rate corresponding to the magic angle of 55°. Finally, each decaying mode was assigned to a fraction of protons localized in the macromolecular structure and characterized by particular dynamics.  相似文献   

8.
9.

Purpose

Time-of-flight (ToF) and phase contrast (PC) magnetic resonance angiographies (MRAs) are noninvasive applications to depict the cerebral arteries. Both approaches can image the cerebral vasculature without the administration of intravenous contrast. Therefore, it is used in routine clinical evaluation of cerebrovascular diseases, e.g., aneurysm and arteriovenous malformations. However, subtle microvascular disease usually cannot be resolved with standard, clinical-field-strength MRA. The purpose of this study was to compare the ability of ToF and PC MRA to visualize the cerebral arteries at increasing field strengths.

Materials and Methods

The Institutional Review Board-approved study included eight healthy volunteers (age: 36±10 years; three female, five male). All subjects provided written informed consent. ToF and PC MRAs were obtained at 1.5, 3 and 7 T. Signal intensities of the large, primary vessels of the Circle of Willis were measured, and signal-to-noise ratios were calculated. Visualization of smaller first- and second-order branch arteries of the Circle of Willis was also evaluated.

Results

The results show that both ToF and PC MRAs allow the depiction of the large primary vessels of the Circle of Willis at all field strengths. Ultrahigh field (7 T) provides only small increases in the signal-to-noise ratio in these primary vessels due to the smaller voxel size acquired. However, ultrahigh-field MRA provides better visualization of the first- and second-order branch arteries with both ToF and PC approaches. Therefore, ultrahigh-field MRA may become an important tool in future neuroradiology research and clinical care.  相似文献   

10.
Sodium-23 magnetic resonance imaging can be used to detect and assess experimental cerebral ischemia in the rat. An imaging technique utilizing a surface coil is described to produce sodium magnetic resonance images of good quality and resolution within 10 min. A novel method of hemispheric occlusion showed edema in the right brain of the rat head within 3 hr after injury. The edema was especially pronounced by 12 hr with effects in the right brain, eye and surrounding muscle evident.  相似文献   

11.
The purposes of this study were to compare the conspicuity and lesion volume of contrast-enhancing macroscopic malignant glioma determined by postcontrast magnetic resonance (MR) imaging with and without magnetization transfer (MT) saturation, and to discuss possible implications for radiotherapy planning. Nineteen patients (age 24–60 years) with histologically proven malignant glioma were prospectively examined by MR imaging. After the administration of gadolinium dimeglumine (0.1 mmol/kg body weight), the lesions were imaged with an MT-weighted FLASH (fast, low-angle shot) pulse sequence and with a conventional T1-weighted spin-echo (SE) sequence without MT saturation. The mean tumor volumes of gliomas measured on MT-weighted FLASH images were significantly (p < .01) larger than those obtained from T1-weighted SE images (45 ± 15 cm3 vs. 33 ± 10 cm3). The mean contrast-to-noise ratio of enhancing lesions on MT-weighted FLASH was 48 ± 14 compared with 30 ± 14 on SE images, representing a significant (p < .01) improvement. We conclude that the volume of contrast enhancement of malignant glioma identified on MT-weighted FLASH images represents the area of disrupted blood-brain barrier. If this volume of subtle contrast enhancement is caused by tumor infiltration and represents the boost target volume for stereotactic radiosurgery or brachytherapy, MT-weighted FLASH images would be better than T1-weighted SE images to define these volumes. These improved delineation of areas at highest risk for recurrence following radiation therapy should enhance the efficacy of treatment planning for high-boost therapy.  相似文献   

12.
A rotating phantom for the study of flow effects in MR imaging   总被引:2,自引:0,他引:2  
A common type of phantom used for the study of flow effects in MR imaging is the tube phantom, where a liquid passes through a set of tubes placed in the main magnetic field of an MR scanner. Among the disadvantages with this type of phantom are that a distribution of velocities is present in each tube, and that quantifications of flow effects using tube phantoms may be very time-consuming. In this work, we describe the design and the properties of a rotating wheel flow phantom used for quantification of the effects of flow through the imaging plane as well as in the imaging plane. The proposed phantom is constructed as a rotating gel-filled wheel, surrounded by static volumes filled with the same gel, and the evaluation of the information from rotating and static parts is made with a specially designed computer program. The phantom can be used as a plug flow phantom covering simultaneously an interchangeable velocity interval, which at present has the range −52 mm/s, +52 mm/s. It is shown that the phantom gives adequate information on the dependence of pixel content on first-order motion in MR modulus and phase images. Among the fields of application are rapid calibration of MR imaging units for flow determination using phase information, as well as testing of pulse sequence characteristics and verification of theoretical predictions concerning the flow dependence in MR images.  相似文献   

13.
Mn+2 (as MnCl2) was administered to rabbits intravenously and orally (a route of administration which based upon our previous experiments in rats7 promises to give selective hepatobiliary enhancement with less systemic toxicity). Nuclear magnetic relaxation dispersion or T1 (NMRD) was performed on selected tissues (heart, liver, kidney, serum, and bile) in both animal groups to examine possible qualitative and semiquantitative differences in T1 relaxation at equivalent sacrifice times. One animal was given an oral dose of MnCl2 (620 micromoles/kg) and imaged sequentially (T1 weighted sequence, .12T) for 30 minutes. The NMRD curves for organ tissues show an increase in relaxation efficacy in the 10–20MHz range characteristic of Mn-macromolecular complexes and are similar irrespective of the route of administration. The lack of increased relaxation enhancement for bile in this frequency range reflects cleavage of this complex upon excretion. Decreased overall relaxation in the liver is observed when oral Mn+2 is compared to IV Mn+2 due to the small fraction of administered dose that is absorbed. However, the images document a significant increase in the intensity of liver signal after the oral dose. We suspect this dose may ultimately be adjusted downward to give selective hepatobiliary effects.  相似文献   

14.
Spin echo images of the carotid arteries in longitudinal view have been obtained by selection of oblique imaging planes. Blood flow within the lumen in the region of the carotid bifurcation has been visualized through the use of cardiac gating during end diastole. Using a surface coil placed about the mandible, high resolution images [(0.75 mm)2 per pixel) were obtained with scan times typically equal to 9 min and image data matrix equal to 256 × 256. Images obtained with this technique of MRI carotid angiography demonstrate blood flow phenomenon as well as vascular anatomy.  相似文献   

15.
We developed a dynamic magnetic resonance (MR) angiographic imaging protocol that can aide the diagnosis of subclavian steal syndrome (SSS). Our protocol combines a new pulse sequence: time-resolved echo-shared angiographic technique (TREAT) with parallel imaging: generalized autocalibrating partially parallel acquisition (GRAPPA). Our pulse sequence, like traditional catheter angiography exams, provides anatomic and dynamic flow pattern information in one scan. If included in comprehensive SSS MR imaging examinations, this sequence can potentially reduce the need for diagnostic X-ray angiography.  相似文献   

16.
Evaluation of the muscular system with magnetic resonance (MR) was conducted: (1) to assess the capability of MR to depict muscular abnormalities; (2) to evaluate the ability of MR to discriminate between various types of muscular pathologies based on relaxation parameters; and (3) to determine the optimal spin echo (SE) sequence that produced optimal contrast. Retrospective analysis was performed on 59 consecutive patients with a variety of muscular abnormalities. MR muscle analysis included visual inspection of contour and size; muscle intensity changes in relation to various TR/TE combinations; measurement of T1 and T2 relaxation and spin density; and calculation of percent contrast variation with different SE imaging combinations. Contour and size abnormalities were not reliable for detection of muscular pathology. For each individual subject intensity and relaxation times of all muscles involved by pathology differed from normal muscle. Although all pathologies caused increase in signal intensity of muscle, the alterations in relaxation times were variable. Fatty atrophy caused a decrease in T1 and increase in T2; while post-surgical changes, infection, acute intramuscular hemorrhage, and tumor invasion caused an increase in both T1 and T2. Percent contrast indicated that the optimum sequence for evaluation of fatty atrophy was a short (0.5 sec) repetition time (TR) and echo delay time (TE) of 56 msec, while for demonstration of the remaining muscular abnormalities, including post-surgical changes, infection, acute intramuscular hemorrhage, and tumor invasion, a long TR (TR = 2.0 sec) and TE (56 msec) was optimal. Differentiation between various benign and malignant muscular abnormalities (excluding fatty atrophy) was not possible using either quantitative intensity values or relaxation times.  相似文献   

17.
The cerebral involvement of a 13-yr-old boy with Wilson's disease was serially evaluated during the first 18 mo of D-penicillamine treatment. An ultra-low-field magnetic resonance imaging (ULF MRI) system, operating at 0.02 T, with computerized image processing was used. The half-yr period prior to the clinical diagnosis was set, the patient had showed poor school performance, emotional lability, deteriorating handwriting, progressively slow, gross, and fine motor functions, and a fixed rigid smile. No overt signs of liver disease were found. With D-penicillamine treatment (1–1.5 g/d) a continuous improvement was seen. The pretreatment MRI investigation showed pronounced pathological transformation in the basal ganglia. However, changes were seen also in most other parts of the brain indicating diffuse involvement. During treatment the computerized MR images became gradually more normal. The current magnetic resonance imaging system with computerized image processing is a sensitive and simple method for evaluation of subtle parenchymal changes of the brain.  相似文献   

18.
Nonspecific extracellular gadolinium chelate (NEGd) was prospectively compared with manganese (Mn)-DPDP (Mn) for the detection and characterization of focal liver lesions of various histology. Seventeen patients with known or suspected focal liver lesions underwent NEGd and Mn-enhanced studies at 1.5 T. Study findings were correlated with histology (five patients), computed tomography (CT) examinations (17 patients), and 4- to 13-month imaging follow-up by CT and/or MR (five patients). NEGd studies were performed as serial postcontrast spoiled gradient echo (SGE) sequences, and Mn studies were performed as SGE sequences 15 and 30 min postcontrast and T1-weighted, fat-suppressed spin echo at 16 min. NEGd and Mn images were prospectively interpreted in a separate blinded fashion. Lesion detection and characterization were determined. NEGd and Mn-enhanced images demonstrated 61 and 49 lesions, respectively (p = .1, NS). A total of 60 and 33 lesions were characterized on NEGd and Mn images, respectively, which was significantly different (p = .008). No differences were observed for the detection and characterization of liver metastases; whereas there was a trend for superior detection and characterization for hepatocellular carcinoma with NEGA.  相似文献   

19.
The development of phase-contrast magnetic resonance imaging (P-C MRI) provides a noninvasive method for measurement of volumetric blood flow (VFR). We performed P-C MRI to study the effects of physical characteristics on cerebral blood flow. VFR of the left and right internal carotid arteries and basilar artery were measured using P-C MRI and total cerebral blood flow (tCBF) was calculated by summing up the VFR values in the three vessels. Moreover, we investigated the changes in these blood flows as influenced by age, head size, height, weight, body surface area, and handedness. The blood flows were 142 ± 58 ml/min (mean ± standard deviation) in the basilar artery; and 229 ± 86 ml/min in the left, and 223 ± 58 ml/min in the right internal carotid artery; and tCBF was 617 ± 128 ml/min. Significant increases were observed in head size-related change of VFR in the basilar artery (p = .028) and height-related change of tCBF (p = .045). The other characteristics did not significantly influence any VFR. The results suggest that head size and height may reflect CBF, and that these effects should be considered when changes of CBF are diagnosed. Phase-contrast MRI is useful for a noninvasive and rapid analysis of cerebral VFR and has potential for clinical use.  相似文献   

20.
Fifty-four independent scans were performed in two volunteers covering one anatomic region in each (the brain and knee) with the purpose of ascertaining the agreement between predicted and measured signal-to-noise ratios (SNR). Systematically varied parameters were number of excitations (NEX), field of view (FOV), section thickness (dz), and the number of phase-encoding steps (Ny). Correlation coefficients of measured versus predicted SNR were 0.82 and 0.86, respectively, in the anatomies studied. Significantly improved correlations were found for data subpopulations in which NEX was held constant. To assess the criteria guiding reader preference, a blinded study was performed in which radiologists were asked to rate images from least to most desirable. In order to quantitatively determine the criteria for reader preference, plots of mean rating versus SNR, voxel volume, and an image quality index [IQI = SNR/(voxel volume)] were performed. The latter was found to be a better predictor of reader preference than either SNR or spatial resolution alone. The data suggests T1-weighted scan protocols yielding SNR of approximately 20 are preferable with any excess SNR being traded for smaller voxel size or shorter scan times.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号