首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple, rapid and sensitive liquid chromatography/electrospray tandem mass spectrometry quantitative detection method, using amantadine as internal standard, was developed for the simultaneous analysis of paracetamol, pseudoephedrine and chlorpheniramine concentrations. Analytes were extracted from plasma samples by liquid–liquid extraction with n-hexane–dichloromethane–2-propanol (2:1:0.1, v/v), separated on a C18 reversed-phase column with 0.1% formic acid–methanol (40:60, v/v) and detected by electrospray ionization mass spectrometry in positive multiple reaction monitoring mode. Calibration curves for plasma were linear over the concentration range 10–10,000 ng mL?1 of paracetamol, 2–2,000 ng mL?1 of pseudoephedrine and 0.2–200 ng mL?1 of chlorpheniramine. The method has a lower limit of quantitation of 10 ng mL?1 for paracetamol, 2.0 ng mL?1 for pseudoephedrine and 0.2 ng mL?1 for chlorpheniramine. Recoveries, precision and accuracy results indicate that the method was reliable within the analytical range, and the use of the internal standard was very effective for reproducibility by LC-MS-MS. This method is feasible for the evaluation of pharmacokinetic profiles of a novel multicomponent sustained release formulation containing 325 mg of paracetamol, 30 mg of pseudoephedrine hydrochloride and 2 mg of chlorpheniramine maleate. It is the first time the pharmacokinetic evaluation of a novel sustained-action formulation containing paracetamol, pseudoephedrine and chlorpheniramine has been elucidated in vivo using LC-MS-MS.  相似文献   

2.
A rapid and specific high-performance liquid chromatographic method coupled with electrospray ionization mass spectrometric detection has been developed and validated for identification and quantification of wogonin and oroxylin A in rat plasma. Wogonin, oroxylin A, and diazepam (internal standard) were extracted from plasma samples by liquid–liquid extraction with ethyl acetate. Chromatographic separation was achieved on a C18 column with acetonitrile–0.6% aqueous formic acid 35:65 (v/v) as mobile phase at a flow rate of 0.2 mL min?1. Detection was performed with a single-quadrupole mass spectrometer in selected-ion-monitoring (SIM) mode. Linearity was good within the concentration range 14.4–360 ng mL?1 for wogonin and 10.8–271 ng mL?1 for oroxylin A; the correlation coefficients (r 2) were 0.9999. The intra-day and inter-day precision, as RSD, was below 12.4%, and accuracy ranged from 81.1 to 111.9%. The lower limit of quantification was 14.4 ng mL?1 for wogonin and 10.8 ng mL?1 for oroxylin A. This method was successfully used in the first pharmacokinetic study of wogonin and oroxylin A in rat plasma after oral administration of the active fraction from Xiao-xu-ming decoction.  相似文献   

3.
A rapid, selective and convenient liquid chromatography–mass spectrometric method for the simultaneous determination of paracetamol and caffeine in human plasma was developed and validated. Analytes and theophylline [internal standard (I.S.)] were extracted from plasma samples with diethyl ether-dichloromethane (3:2, v/v) and separated on a C18 column (150 × 4.6 mm ID, 5 μm particle size, 100 Å pore size). The mobile phase consisted of 0.2% formic acid–methanol (60:40, v/v). The assay was linear in the concentration range between 0.05 and 25 μg mL?1 for paracetamol and 10–5,000 ng mL?1 for caffeine, with the lower limit of quantification of 0.05 μg mL?1 and 10 ng mL?1, respectively. The intra- and inter-day precision for both drugs was less than 8.1%, and the accuracy was within ±6.5%. The single chromatographic analysis of plasma samples was achieved within 4.5 min. This validated method was successfully applied to study the pharmacokinetics of paracetamol and caffeine in human plasma.  相似文献   

4.
A highly sensitive liquid chromatographic-atmospheric pressure chemical ionization-tandem mass spectrometric method is developed to quantitate phenacetin and its metabolite paracetamol in rabbit plasma. The analytes and internal standard oxazepam are extracted from plasma by liquid–liquid extraction using ethyl acetate, and separated on a Zorbax SB-C18 column (2.1 mm × 150 mm, 5 μm) using acetonitrile–0.1% formic acid in water (40:60 v/v) at a flow of 0.4 mL min?1. Detection is carried out by multiple reaction monitoring on a ion-trap LC-MS-MS system with an atmospheric pressure chemical ionization interface. The assay is linear over the range 4–1,600 ng mL?1 for phenacetin and 3–2,000 ng mL?1 for paracetamol, with a lower limit of quantitation of 4 ng mL?1 for phenacetin and 3 ng mL?1 for paracetamol. Intra- and inter-day precision are less than 7.1% and the accuracy are in the range 97.3–103.5%. The validated method is successfully used to analyze the drug in samples of rabbit plasma for pharmacokinetic study.  相似文献   

5.
A liquid chromatography–electrospray ionization tandem mass spectrometry method has been developed to perform the determination of 5-hydroxytryptamine (5-HT), norepinephrine (NE), dopamine (DA) and their metabolites, i.e., 5-hydroxyindole-3-acetic acid (5-HIAA), 4-hydroxy-3-methoxyphenylglycol (MHPG) sulfate, 3,4-dihydroxyphenylacetic acid (DOPAC) and homovanillic acid (HVA) in rat brain tissue. Analytes were separated on a Thermo C18 column (4.6 mm × 250 mm, 5 μm, SN: 1245575T, Thermo electron corporation, USA) with a mobile phase of 0.05% formic acid/acetonitrile (92:8 for ESI+, 82:18 for ESI?, v/v) at the flow-rate of 0.8 mL min?1. The LC system was coupled to a Waters Micromass Quattro Premier XE tandem quadruple mass spectrometer. MS acquisition of 5-HT, NE and DA was performed in positive electrospray ionization multiple reaction monitoring (MRM) mode, while negative electrospray ionization MRM mode was used to monitor their metabolites. The calibration curves were linear within the concentration range of 4–4,450 ng mL?1 for 5-HT, 4–4,110 ng mL?1 for NE and 4–4,100 ng mL?1 for DA (≥ 0.999). The limit of quantitation was 4 ng mL?1. 5-HIAA, MHPG, DOPAC and HVA have good linearity within the range of 12–1,000 ng mL?1(≥ 0.998) and the limit of quantitation was 12 ng mL?1. The intra- and inter-day RSD were lower than 8.45%. The method is sensitive, fast, accurate and usable for quantity determination of monoamine neurotransmitters and their metabolites in neuropsychiatric diseases.  相似文献   

6.
A selective, sensitive, and accurate method has been developed and validated for the quantification of tangeretin in rat plasma. The application of LC-electrospray-ion trap mass spectrometry in full scan and multiple reactions monitoring modes were investigated. Following solid phase extraction using a hydrophilic–lipophilic balance cartridge, the analytes were separated on a C18 column using an isocratic mobile phase composed of acetonitrile/water (50:50, v/v) containing 0.3% formic acid. In full scan mode, the LOQ was 2 ng mL?1. The standard calibration curve was linear (R 2 = 0.9999) over the concentration range 2–200 ng mL?1. The precision over the concentration range was within 15% (RSD) and the accuracy was ranged from 86 to 115%. In multiple reaction monitoring mode, the LOQ was 1 ng mL?1 and the standard calibration curve was linear (R 2 = 0.9976) over the concentration range 1–100 ng mL?1 with a precision of 12% and accuracy rangeing from 91 to 113%.  相似文献   

7.
A sensitive LC–MS–MS method with electrospray ionization has been developed for determination of nikethamide in human plasma. After addition of atropine as internal standard, liquid–liquid extraction was used to produce a protein-free extract. Chromatographic separation was achieved on a 150 mm × 2.1 mm, 5 μm particle, Agilent Zorbax SB-C18 column, with 45:55 (v/v) methanol–water containing 0.1% formic acid as mobile phase. LC–MS–MS was performed in multiple reaction monitoring mode using target fragment ions m/z 178.8 → 107.8 for nikethamide and m/z 289.9 → 123.8 for the internal standard. Calibration plots were linear over the range of 20.0–2,000 ng mL?1. The lower limit of quantification was 20.0 ng mL?1. Intra-day and inter-day precisions were better than 4.2 and 6.1%, respectively. Mean recovery of nikethamide from human plasma was in the range 65.3–71.1%.  相似文献   

8.
A reliable and sensitive liquid chromatographic–tandem mass spectrometric method, with rutin as internal standard, has been developed and validated for simultaneous determination of danshensu, salvianolic acid B (SAB), and hydroxysafflor yellow A (HSYA) in beagle dog plasma. Plasma samples spiked with the analytes were extracted by solid-phase extraction and the analytes were separated on a 250 × 4.6 mm i.d., 5-μm particle, C18 column with methanol–acetonitrile–0.5% formic acid 20:25:55 (v/v) as mobile phase at a flow rate of 1 mL min?1. LC–MS–MS analysis was performed with a Finnigan TSQ triple-quadrupole tandem mass spectrometer operated in negative-ion selected-reaction-monitoring mode, using electrospray ionization. The accuracy and precision of the method were acceptable and linearity was good over the range 20–4,000 ng mL?1 for danshensu, 50–10,000 ng mL?1 for SAB, and 10–2,000 ng mL?1 for HSYA. The method was successfully applied to a pharmacokinetic study of a traditional Chinese medicinal preparation, Danhong lyophilized powder for injection.  相似文献   

9.
A sensitive and specific liquid chromatography-tandem-mass spectrometry method was developed and validated for the simultaneous determination of clopidogrel and its carboxylic acid metabolite (SR26334) in human plasma using nateglinide and pioglitazone as internal standards. Analytes were extracted from 0.50 mL of plasma using diethyl ether–n-hexane (4:1, v/v). Chromatographic separation was performed on a Teknokroma C18 column with a mobile phase of methanol–water (containing 0.1% formic acid) (80:20, v/v) at a flow rate of 0.20 mL min?1 within 5.6 min. Linearity was established over the concentration range of 0.005–5 ng mL?1 for clopidogrel and 20–2,500 ng mL?1 for SR26334. Intra- and inter-batch standard deviations were less than 9.2% and the accuracy of this assay was found to fall within an acceptable range ≤10.0%. The method was successfully applied to the therapeutic drug monitoring of clopidogrel.  相似文献   

10.
A sensitive and rapid LC–MS–MS method was developed for the simultaneous determination of ebastine and carebastine in human plasma. Solid-phase extraction was used to isolate the compounds from the biological matrix followed by separation on a Symmetry C18 column under isocratic conditions. The mobile phase was 10 mM ammonium formate in water/acetonitrile (40:60, v/v). Detection was carried out using a triple-quadrupole mass spectrometer in positive electrospray ionization and multiple reaction monitoring mode. The method was fully validated over the concentration range of 0.1–10 ng mL?1 for ebastine and 0.2–200 ng mL?1 for carebastine in human plasma, respectively. The lower limit of quantification (LLOQ) was 0.1 ng mL?1 for ebastine and 0.2 ng mL?1 for carebastine. For ebastine and carebastine inter- and intra-day precision (CV%) and accuracy values were all within ±15% and 85–115%, respectively. The extraction recovery was on average 60.0% for ebastine and 60.3% for carebastine.  相似文献   

11.
A sensitive, simple, and accurate method for determination and pharmacokinetic study of ferulic acid and isoferulic acid in rat plasma was developed using a reversed-phase column liquid chromatographic (RP-LC) method with UV detection. Sample preparations were carried out by protein precipitation with the addition of methanol, followed by evaporation to dryness. The resultant residue was then reconstituted in mobile phase and injected into a Kromasil C18 column (250 × 4.6 mm i.d. with 5 μm particle size). The mobile phase was methanol-1% formic acid (33:67, v/v). The calibration plots were linear over the range 5.780–5780 ng·mL?1 for ferulic acid and 1.740–348.0 ng·mL?1 for isoferulic acid. Mean recoveries were 85.1% and 91.1%, respectively. The relative standard deviations (RSDs) of within-day and between-day precision were not above 15% for both of the analytes. The limits of quantification were 5.780 ng·mL?1 for ferulic acid and 1.740 ng·mL?1 for isoferulic acid. This RP-LC method was used successfully in pharmacokinetic studies of ferulic acid and isoferulic acid in rat plasma after intravenous injection of Guanxinning Lyophilizer.  相似文献   

12.
A simple, sensitive and specific liquid chromatographic method with UV detection (228 nm) was developed for the simultaneous estimation of rosiglitazone and glimepride in human plasma. Rosiglitazone and glimepride were extracted from plasma using liquid–liquid extraction. Separation was achieved with an RP C18 Column using a mixture of phosphate buffer (50 mM) with octane sulfonic acid (10 mM), methanol and acetonitrile as a mobile phase (55:10:35, v/v). pH was adjusted to 7.0. Amlodipine was used as an internal standard (IS). LOD of the method was found to be 20 ng mL?1 for both drugs. Results were linear over the studied range 40.994–2007.556 ng mL?1 for rosiglitazone (r ≥ 0.99) and 41.066–2094.84 ng mL?1 for glimepride( r ≥ 0.99). The method was found to be simple, selective, precise and reproducible for the estimation of both drugs from spiked human plasma.  相似文献   

13.
A simple, rapid, and sensitive liquid chromatography–mass spectrometric (LC–MS) method was developed and validated for the determination of isoniazid in dog plasma. Plasma samples were deproteined with methanol and separated on a C18 column interfaced with a single quadrupole mass spectrometer, using 0.1% formic acid–acetonitrile (91:9 v/v) as mobile phase. Detection was performed by positive electrospray ionization with selected ion monitoring at m/z 138 for isoniazid and 152 for entecavir maleate internal standard. Linearity was obtained over the range of 25–5,000 ng mL?1, with a lower limit of quantification of 25 ng mL?1. The intra- and inter-day precision was less than 2.7% in terms of relative standard deviation. Accuracy, expressed as relative error, ranged from ?2.0 to 8.0%. Plasma samples were analysed within 5 min. The method was successfully applied to the evaluation of the pharmacokinetics of isoniazid in dog plasma.  相似文献   

14.
A rapid LC method with UV detection was developed for the quantification of carboxylic acid metabolite of clopidogrel in human plasma. Following a simple protein precipitation using a mixture of methanolic solution of ZnSO4, the analyte and commercially available internal standard were separated using a mobile phase of water–acetonitril (85:15, v/v) adjusted to pH 3.5 on a Chromolith C18 column at a flow rate of 2.5 mL min?1 with a total retention time of 4 min. Linearity was verified over the range of 20–3,000 ng mL?1 where the LOQ was 20 ng mL?1. This method was applied in a pharmacokinetic study.  相似文献   

15.
A simple, rapid, sensitive and reliable liquid chromatography–electrospray ionization mass spectrometry method for the quantification of imperatorin in rat plasma after oral administration and total furocoumarins of Radix Angelica dahuricae has been established. The plasma samples were deproteinized by adding internal standard (IS) osthole solution, which was prepared by acetonitrile. The analysis was performed on a Shim-pack C18 column (150 × 2.0 mm i.d., 5 μm) using acetonitrile and 0.5% formic acid solution (70:30, v/v) as a mobile phase. The detection was performed on a quadrupole mass spectrometer detector with an ESI interface operated in the selected ion monitoring mode. The linear quantification range of the method was 2–4000 ng mL?1 in rat plasma with a correlation coefficient greater than 0.99, the limit of detection (LOD) was 0.5 ng mL?1 and the lower limit of quantification (LLOQ) 2 ng mL?1. The intra- and inter-day relative standard deviations (RSD) were less than 2.5 and 3.5%, respectively. The recoveries were above 90%. The validated method was successfully applied to a pharmacokinetic study of imperatorin in rats after oral administration and total furocoumarins of Radix Angelica dahuricae.  相似文献   

16.
A novel sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS-MS) method simultaneously determined buprenorphine (BUP) and its active metabolite, norbuprenorphine (NBUP), and a coformulant, naloxone was developed, validated and applied successfully in humans. Buprenorphine-d 4 and norbuprenorphine-d 3 were used as the internal standard. The analysis was performed on a silica column, and the mobile phase was isocratic and composed of acetonitrile:2 mM ammonium formate in H2O (82:18, v/v). Mass spectrometry employed multiple reaction monitoring modes with transitions of m/z 468.1?C55.2 for BUP, 414.2?C101.2 for NBUP, 328.3?C310.3 for naloxone, 472.1?C59.2 for buprenorphine-d 4 and 417.2?C101.2 for norbuprenorphine-d 3. Lower limit of quantification (LLOQ) of the analytical method was 0.05 ng mL?1 for BUP, 0.1 ng mL?1 for NBUP and 0.025 ng mL?1 for naloxone, respectively. The standard calibration curves of BUP, NBUP and naloxone were linear over the concentration range of 0.05?C20 ng mL?1, 0.1?C20 ng mL?1 and 0.025?C20 ng mL?1, respectively. The precisions (RSD) and accuracies (RE) of LLOQ and other QC samples were in acceptable range, with RSD < 20% and RE ± 20% for LLOQ and RSD < 15% and RE within ±15% for QC samples. The method was accurate, precise and specific, and was applied to the pharmacokinetic study of buprenorphine in healthy volunteers.  相似文献   

17.
A valid and sensitive LC-MS–MS method is adopted for pharmacokinetics study of berberine and palmatine in rabbit plasma. After mixing with internal standard tetrahydroberberine, plasma samples were pretreated with 1.5 mL acetonitrile. Chromatographic separation was on a C18 column using a mixture of water (containing 10 mmol L?1 ammonium acetate, pH 3.5) and acetonitrile (50∶50, v/v) as mobile phase. The detection was performed by selected ion monitoring mode via electrospray ionization source operating in the positive ionization mode. The method was linear over the concentration range of 2.0–200.0 ng mL?1 for berberine and 1.0–100.0 ng mL?1 for palmatine. The lowest limits of quantitation (LLOQ) were 2.0 ng mL?1 for berberine and 1.0 ng mL?1 for palmatine. The intra- and inter-day precision values were less than 14.3% and the deviations were within ±11.0%. The fully validated LC-MS–MS method has been successfully applied to a pharmacokinetic study of berberine, palmatine in rabbit plasma after oral administration of Coptidis and coptidis–gardeniae couple extract. The results indicated that the plasma profiles of the two compounds in rabbit confirmed to one-compartment open model and the combinational utilization with Gardeniae could increase the bioavailability of berberine and palmatine, the two major active components of Coptidis.  相似文献   

18.
A sensitive liquid chromatography-tandem-mass spectrometry method was developed and validated for the determination of perospirone in human plasma, using quetiapine as internal standard. Plasma samples were extracted from 1 mL of plasma using n-hexane. Chromatographic separation was performed on an Agilent Zorbax SB C18 column with a mobile phase of 5 mM ammonium acetate solution-methanol (12:88, v/v, adjusted to pH 3.8 with glacial acetic acid) at a flow rate of 0.2 mL min?1. The chromatographic separation was achieved in less than 4.6 min. The linearity was established over the concentration range of 0.05–20 ng mL?1. Both of the intra- and inter-batch standard deviation was less than 9.8%. The method was successfully applied to study the pharmacokinetic parameters of perospirone hydrochloride tablets in healthy Chinese volunteers.  相似文献   

19.
A sensitive and selective liquid chromatography–tandem mass spectrometry method for the determination of memantine was developed and validated over the linearity range 0.1–25 ng mL?1 with 0.5 mL of plasma using procainamide as the internal standard. This analysis was carried out on a Cosmosil 5C18-MS column and the mobile phase was composed of methanol: 0.5% formic acid (50:50, v/v). Detection was performed on a triple–quadrupole tandem mass spectrometer using positive ion mode electrospray ionization and quantification was performed by multiple reaction monitoring mode. The MS–MS ion transitions monitored were m/z 180 → 107 and 236 → 163 for memantine and procainamide, respectively. The between- and within-day precision was less than 10.9% and accuracy was less than 2.5%. The lower limit of quantification (LLOQ) was 0.1 ng mL?1. The method proved to be accurate and specific, and was applied to the pharmacokinetic study of memantine in healthy Chinese volunteers.  相似文献   

20.
L. Ma  J. Dong  X. J. Chen  G. J. Wang 《Chromatographia》2007,65(11-12):737-741
The aim of this research was to develop a sensitive liquid chromatographic–electrospray ionization–mass spectrometric (LC–MS) method for direct measurement of the concentration of Atorvastatin in human plasma. Plasma samples (1 mL) were extracted with 3 mL ethyl acetate, and by a simple reversed-phase chromatography. Pitavastatin was used as internal standard (IS). The LOQ was 0.25 ng mL?1 (RSD 4.24%). The assay was linear from 0.25–20 ng mL?1. And the correlation coefficient for the calibration regression line was 0.9996 or better. Intra-day and inter-day accuracy were better than 15%. The method has been successfully used for a pharmacokinetic study with human subjects. A two-period crossover designed bioequivalence research was also progressed in healthy Chinese volunteers. Among the pharmacokinetic data obtained, T max was 1.36 ± 0.68 h for reference formulation and 0.81 ± 0.54 h for test formulation. C max was 8.54 ± 5.06 ng mL?1 for reference formulation and 9.54 ± 3.68 ng mL?1 for test formulation. t 1/2 was 8.50 ± 2.74 h for reference formulation and 9.24 ± 3.17 h for test formulation. AUC 0?48h was 54.77 ± 21.82 h ng mL?1 for reference formulation and 55.66 ± 20.91 h ng mL?1 for test formulation. The method was successfully applied to the study of pharmacokinetics of Atorvastatin in healthy Chinese volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号