首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Nanoscale separation techniques, nanoscale packed capillary columns (75 μm id), and capillary zone electrophoresis (CZE), on-line with electrospray mass spectrometry (ESI/MS), were applied to the separation of a series of ten macrolide antibiotics. Both techniques use sub-microliter-per-minute flow rates through the analytical column and therefore require an electrospray probe that incorporates coaxial sheath flow. Positive ion electrospray mass spectra of these compounds yielded mainly protonated molecules. Fragmentation to yield structurally significant fragment ions was achieved by collision-induced dissociation (CID) at increased skimmer voltages. Separations were achieved using both techniques, with CZE/ESI/MS showing improved peak shapes and detection limits combined with faster analysis times. Nanoscale packed capillary columns provided better chromatographic resolution and was less susceptible to peak broadening caused by overloading of the analytes.  相似文献   

2.
The use of capillary zone electrophoresis (CZE) and capillary zone electrophoresis/mass spectrometry (CZE/MS) has been demonstrated, in principle, for the separation of nicotine and nicotine metabolites. The buffer system developed for separation and detection by CZE/UV was modified for use in CZE/MS analysis. Several of the metabolites are isobaric and tandem mass spectrometric (MS/MS) techniques have been used to differentiate such analytes.  相似文献   

3.
Sixteen synthetic chemical drugs, often found in adulterated Chinese medicines, were studied by capillary electrophoresis/UV absorbance (CE/UV) and capillary electrophoresis/electrospray ionization mass spectrometry (CE/ESI-MS). Only nine peaks were detected with CZE/UV, but on-line CZE/MS provided clear identification for most compounds. For a real sample of a Chinese medicinal preparation, a few adulterants were identified by their migration times and protonated molecular ions. For coeluting compounds, more reliable identification was achieved by MS/MS in selected reaction monitoring mode. Micellar electrokinetic chromatography (MEKC) using sodium dodecyl sulfate (SDS) provided better separation than capillary zone electrophoresis (CZE), and, under optimal conditions, fourteen peaks were detected using UV detection. In ESI, the interference of SDS was less severe in positive ion mode than in negative ion mode. Up to 20 mM SDS could be used in direct coupling of MEKC with ESI-MS if the mass spectrometer was operated in positive ion mode. Because of better resolution in MEKC, adulterants can be identified without the use of MS/MS.  相似文献   

4.
Amino acids residues are commonly submitted to various physicochemical modifications occurring at physiological pH and temperature. Post‐translational modifications (PTMs) require comprehensive characterization because of their major influence on protein structure and involvement in numerous in vivo process or signaling. Mass spectrometry (MS) has gradually become an analytical tool of choice to characterize PTMs; however, some modifications are still challenging because of sample faint modification levels or difficulty to separate an intact peptide from modified counterparts before their transfer to the ionization source. Here, we report the implementation of capillary zone electrophoresis coupled to electrospray ionization tandem mass spectrometry (CZE‐ESI‐MS/MS) by the intermediate of a sheathless interfacing for independent and highly sensitive characterization of asparagine deamidation (deaN) and aspartic acid isomerization (isoD). CZE selectivity regarding deaN and isoD was studied extensively using different sets of synthetic peptides based on actual tryptic peptides. Results demonstrated CZE ability to separate the unmodified peptide from modified homologous exhibiting deaN, isoD or both independently with a resolution systematically superior to 1.29. Developed CZE‐ESI‐MS/MS method was applied for the characterization of monoclonal antibodies and complex protein mixture. Conserved CZE selectivity could be demonstrated even for complex samples, and foremost results obtained showed that CZE selectivity is similar regardless of the composition of the peptide. Separation of modified peptides prior to the MS analysis allowed to characterize and estimate modification levels of the sample independently for deaN and isoD even for peptides affected by both modifications and, as a consequence, enables to distinguish the formation of l ‐aspartic acid or d ‐aspartic acid generated from deaN. Separation based on peptide modification allowed, as supported by the ESI efficiency provided by CZE‐ESI‐MS/MS properties, and enabled to characterize and estimate studied PTMs with an unprecedented sensitivity and proved the relevance of implementing an electrophoretic driven separation for MS‐based peptide analysis. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

5.
Low-impact ionization sources like electrospray ionization (ESI) and matrix-assisted, laser desorption/ionization (MALDI) equipped with time-of-flight (TOF) mass analyzers provide intact protein analysis over a very wide molar mass range. ESI/TOFMS provides also indications on the higher-order structure of intact proteins and non-covalent protein complexes. However, direct analysis of intact proteins mixtures in real samples shows limited success, mainly because spectra become very complex to interpret. This is also due to sample contaminants, and to the mechanism of competitive ionization in ESI or MALDI. Rapid and efficient sample clean-up and separation methods can significantly enhance the power of TOFMS for intact protein analysis. However, if protein native conditions want to be maintained, the methods should affect neither the three-dimensional structure nor the non-covalent chemistry of the proteins. Reversed-phase (RP) HPLC, size-exclusion chromatography (SEC), and capillary zone electrophoresis (CZE) are on-line or off-line coupled to ESI/TOFMS or MALDI/TOFMS. In fact, these separation methods often show limitations when applied to the analysis of native proteins. Organic modifiers and saline buffers are required in the case of RP HPLC or CZE. They can induce protein degradation or affect ionization when MS is performed after separation. High voltages used in CZE can contribute to alter proteins from their native form. In the case of high molar mass proteins, SEC is scarcely selective, and barely able to detect protein aggregates. Sample entanglement/adsorption on the stationary phase can also occur.  相似文献   

6.
Amon S  Plematl A  Rizzi A 《Electrophoresis》2006,27(5-6):1209-1219
Defined conditions of EOF along with different pH values of the BGE were compared for the purpose of analyzing glycopetides by CZE coupled to MS (CZE-MS). Hyphenation to MS involved ESI as well as MALDI, and single-stage and multistage MS were applied. Variation of the EOF was accomplished by selecting appropriate coatings for the capillary, namely hexadimethrine bromide (HDMB) and HDMB/dextran sulfate. A high and reproducible anodic and cathodic EOF, respectively, was obtained in both approaches, allowing the detection of analytes with net positive as well as negative charge in one single run. Thus, a fast and sensitive determination of the glycopeptides in a tryptic digest of antithrombin, chosen as a test sample, was achieved. Ionization suppression effects, a phenomenon typically observed with glycopeptides in MS analysis, were minimized thanks to separation from other peptides present. The high stability of the coatings permitted the generation of mass spectra without interfering peaks originating from the coating polymers. The high EOF generated by the coatings facilitated the maintenance of a stable spray when coupling to ESI-MS, and a stable CZE current when working with a sheath flow-assisted analyte deposition onto MALDI targets, respectively. In conclusion, CZE-MS could be demonstrated as a robust complementary method to capillary RP-HPLC-MS in combination with both soft-ionization techniques, ESI and MALDI, generally, and particularly in the context of glycopeptide analysis.  相似文献   

7.
Different approaches for the separation of a set of nucleosides and nucleobases using capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC) are described. Several electrolyte compositions have been tested for this purpose. The addition of appropriate amounts of borate to the carrier electrolyte allowed manipulating migration orders in CZE and MEKC by selective complexation of the nucleosides. For detection either UV or two different modes of mass spectrometric (MS) detection were employed. The latter approach included a comparison of two ion sources namely electrospray ionization (ESI) and atmospheric pressure photoionization (APPI) with respect to their potential in the detection of the selected compounds. Thereby it could be demonstrated that, in particular when it comes to the analysis of real samples, APPI-MS is the better choice if MS detection of purines and pyrimidines after separation by CZE is required.  相似文献   

8.
Pelzing M  Neusüss C 《Electrophoresis》2005,26(14):2717-2728
Liquid chromatography (LC) nanoelectrospray-tandem mass spectrometry (MS/MS) is a key technology for the study of proteomics, with the main benefit to the characterization of sensitive peptides from complex mixtures. Capillary electrophoresis coupled to mass spectrometry (MS) has been taken into consideration sporadically due to the highly efficient separation and ability to handle low sample amount, yet classified as being less sensitive with respect to analyte concentration. The limitation in capillary zone electrophoresis (CZE) injection volumes can be overcome by on-line solid-phase extraction (SPE). Such an on-line SPE-CZE system was explored in combination with an ion trap (IT) mass spectrometer. Thus, it was possible to inject more than 100 microL sample solution on to the CZE capillary. Concentration limits of detection as low as 100 amol/microL were demonstrated for a peptide standard. This SPE-CZE-microelectrospray ionization (ESI)-MS/MS setup was compared directly to nanoLC/nanoESI using the same sample of a tryptic digest of bovine serum albumin (BSA) as a reference standard. Measurements were made on one IT mass spectrometer with identical acquisition parameters. Both chromatography systems enabled the separation and detection of low levels of peptides from a mixture of moderate complexity, with most peptides identified using both techniques; however, specific differences were obvious. The nanoLC-MS is about five times more sensitive than the CZE-MS, yet the difference was less pronounced than expected. The CZE-MS technique showed reduced loss of peptides, especially for larger peptides (missed cleavages) and is about four times faster than the nanoLC-MS approach.  相似文献   

9.
A new technique for coupling capillary isotachophoresis (CITP) to Inductive coupled plasmas atomic emission spectrometry (ICP-AES) using flow injection (FI) is developed. Great attention to CITP have been paid owing to its broad application prospect in biochemistry, clinic, pharmacy, food,environment detection and conventional ionic analysis. Its zone-boundary sharpening, large size capillary and self-concentrating effects are different from those of other electrophoretic techniques. Recently, ICP-AES/MS, as a special metal detector, has been combined with the capillary zone electrophoresis (CZE). However, in CZE system, typical sample volume and flow rate are only in the range of 0.02 - 1 μl/min and 0.2-2μl, which results in the difficult for the coupling of CZE and ICP with conventional sampling system and the obtaining enough sensitivity.  相似文献   

10.
We have evaluated CZE‐ESI‐MS/MS for detection of trace amounts of host cell protein impurities in recombinant therapeutics. Compared to previously published procedures, we have optimized the buffer pH used in the formation of a pH junction to increase injection volume. We also prepared a 5‐point calibration curve by spiking 12 standard proteins into a solution of a human mAb. A custom CZE‐MS/MS system was used to analyze the tryptic digest of this mixture without depletion of the antibody. CZE generated a ~70‐min separation window (~90‐min total analysis duration) and ~300‐peak capacity. We also analyzed the sample using ultra‐performance LC‐MS/MS. CZE‐MS/MS generated approximately five times higher base peak intensity and more peptide identifications for low‐level spiked proteins. Both methods detected all proteins spiked at ~100 ppm level with respect to the antibody.  相似文献   

11.
Capillary electrophoresis (CE) offers fast and high‐resolution separation of charged analytes from small injection volumes. Coupled to mass spectrometry (MS), it represents a powerful analytical technique providing (exact) mass information and enables molecular characterization based on fragmentation. Although hyphenation of CE and MS is not straightforward, much emphasis has been placed on enabling efficient ionization and user‐friendly coupling. Though several interfaces are now commercially available, research on more efficient and robust interfacing with nano‐electrospray ionization (ESI), matrix‐assisted laser desorption/ionization (MALDI) and inductively coupled plasma mass spectrometry (ICP) continues with considerable results. At the same time, CE‐MS has been used in many fields, predominantly for the analysis of proteins, peptides and metabolites. This review belongs to a series of regularly published articles, summarizing 248 articles covering the time between June 2016 and May 2018. Latest developments on hyphenation of CE with MS as well as instrumental developments such as two‐dimensional separation systems with MS detection are mentioned. Furthermore, applications of various CE‐modes including capillary zone electrophoresis (CZE), nonaqueous capillary electrophoresis (NACE), capillary gel electrophoresis (CGE) and capillary isoelectric focusing (CIEF) coupled to MS in biological, pharmaceutical and environmental research are summarized.  相似文献   

12.
Simpson DC  Smith RD 《Electrophoresis》2005,26(7-8):1291-1305
Mass spectrometry (MS)-based proteomics is currently dominated by the analysis of peptides originating either from digestion of proteins separated by two-dimensional gel electrophoresis (2-DE) or from global digestion; the simple peptide mixtures obtained from digestion of gel-separated proteins do not usually require further separation, while the complex peptide mixtures obtained by global digestion are most frequently separated by chromatographic techniques. Capillary electrophoresis (CE) provides alternatives to 2-DE for protein separation and alternatives to chromatography for peptide separation. This review attempts to elucidate how the most promising CE modes, capillary zone electrophoresis (CZE) and capillary isoelectric focusing (CIEF), might best be applied to MS-based proteomics. CE-MS interfacing, mass analyzer performance, column coating to minimize analyte adsorption, and sample stacking for CZE are considered prior to examining numerous applications. Finally, multidimensional systems that incorporate CE techniques are examined; CZE often finds use as a fast, final dimension before ionization for MS, while CIEF, being an equilibrium technique, is well-suited to being the first dimension in automated fractionation systems.  相似文献   

13.
《Electrophoresis》2017,38(6):914-921
CIEF represents an elegant technique especially for the separation of structural similar analytes, whereas MS is a state‐of‐the‐art instrumentation for the identification and characterization of biomolecules. The combination of both techniques can be realized by hyphenating CIEF with CZE‐ESI‐MS applying a mechanical valve. During the CZE step, the remaining ESI‐interfering components of the CIEF electrolyte are separated from the analytes prior to MS detection. In this work, a multiple heart‐cut approach is presented expanding our previous single heart‐cut concept resulting in a dramatical reduction of analysis time. Moreover, different sample transfer loop volumes are systematically compared and discussed in regard to peak width and transfer efficiency. With this major enhancement, model proteins (1.63–9.75 mg/L), covering a wide pI range (5–10), and charge variants from a deglycosylated model antibody were analyzed on intact level. The promising CIEF‐CZE‐MS setup is expected to be applicable in different bioanalytical fields, e.g. for the fast and information rich characterization of therapeutic antibodies.  相似文献   

14.
毛细管电泳质谱联用技术及其应用   总被引:9,自引:0,他引:9  
本文介绍了用于毛细管电泳质谱联用仪器的多种接口技术,描述了CZE,CIEF,CGE,MEKC和CITP等毛细管电泳技术和四极质谱,离子阱质谱,傅 叶变换离子回旋共振质谱,飞行时间质谱,磁质谱,解吸质谱等联用的现状及发展前景,对近年来CE-MS在酶解产物。蛋白质和肽,核苷酸,药物及代谢产物等领域中的应用作了详细述评。  相似文献   

15.
Increases in the study of protein‐metal complexes, as well as in metal displacement in protein‐metal complexes under native conditions for optimum catalytic properties in drug research and catalyst design, demands a separation/detection technology that can accurately measure metal displacement and stoichiometry in protein‐metal complexes. Both nuclear magnetic resonance (NMR) and X‐ray diffraction techniques have been used for this purpose; however, these techniques lack sensitivity. Electrospray ionization mass spectrometry (ESI‐MS) using direct infusion offers higher sensitivity than the former techniques and provides molecular distribution of various protein‐metal complexes. However, since protein‐metal complexes under native conditions usually are dissolved in salt solutions, their direct ESI‐MS analysis requires off‐line sample clean‐up prior to MS analysis to avoid sample suppression during ESI. Moreover, direct infusion of the salty solution promotes non‐specific salt adduct formation by the protein‐metal complexes under ESI‐MS, which complicates the identification and stoichiometry measurements of the protein‐metal complexes. Because of the high mass of protein‐metal complexes and lack of sufficient resolution by most mass spectrometers to separate non‐specific from specific metal‐protein complexes, accurate protein‐metal stoichiometry measurements require some form of sample clean up prior to ESI‐MS analysis. In this study, we demonstrate that capillary electrophoresis/electrospray ionization in conjunction with a medium‐resolution (~10 000) mass spectrometer is an efficient and fast method for the measurement of the stoichiometry of the protein‐metal complexes under physiological conditions (pH ~7). The metal displacement of Co2+ to Cd2+, two metal ions necessary for activation in the monomeric AHL lactonase produced by B. thuringiensis, has been used as a proof of concept. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
High-efficiency separations of peptide mixtures, tryptic digest and other biological compounds have been achieved using nanoscale packed capillaries and capillary zone electrophoresis (CZE). The coaxial continuous-flow fast atom bombardment design is an excellent interface for coupling these separation techniques with mass spectrometry (MS). In addition, this interface is very useful for the acquisition of MS-MS data from compounds separated by nanoscale packed capillary liquid chromatography and CZE. Structurally informative daughter-ion spectra can be obtained at the low picomole to femtomole level.  相似文献   

17.
Disaccharides tagged with p-aminobenzoic acid (ABA) were separated by capillary electrophoresis (CE) and analyzed on-line with negative ion electrospray ionization tandem mass spectrometry (ESI/MS/MS). The formation of glycosylamine instead of reductive amination was selected as the derivatization reaction. In negative ion ESI, the glycosylamine approach provides more information on linkage and anomeric configuration than reductive amination. In CE analysis of ABA-labeled disaccharides, alpha-cyclodextrin (CD) was found to play a crucial role in the separation of linkage isomers. Although ammonium acetate/alpha-CD provided the best resolution of linkage isomers, the borate buffer was superior to alpha-CD in the separation of disaccharides with the same linkage but different anomeric configuration and/or monosaccharide composition. Both alpha-CD and borate suppressed the ion signal in ESI, and operational conditions were successfully obtained using 10 mM alpha-CD or 10 mM borate.  相似文献   

18.
The analysis of low-abundant compounds with capillary zone electrophoresis–drift-tube ion mobility spectrometry–mass spectrometry (CZE–DTIMS–MS) is compromised due to the low injectable sample volumes in CZE and low duty cycle in DTIMS. Fritless packed in-line trap columns, using solid-phase extraction sorbent particles, have been used to increase injection volumes in CZE, but these columns are difficult to prepare and exhibit rapidly increasing back pressures. To provide smooth and complete filling of trap columns as well as to ensure higher and sustained flow rates though the columns, blends of cation and anion exchange particles with diatomite were used. The application of diatomite blends ensured the use of trap columns for at least 100 injections, with maximum injection volumes over 10 µl, which corresponds to an enrichment factor of more than 1000 over conventional injections in CZE–MS, enabling the detection of low nM concentrations of N-glycans with CZE–IMS–MS.  相似文献   

19.
Micellar liquid chromatography (MLC) and capillary zone electrophoresis (CZE) have been evaluated for the analysis of twelve banned drugs in sport including diuretics and -blockers. In MLC, a sodium dodecylsulphate aqueous solution has been used as mobile phase using an octadecylsilica column. In CZE, a pH 8 buffer solution and a silica capillary have been employed. Parameters of retention and efficiency have been compared. Limits of detection with UV detection at 254 nm and relative standard deviations for atenolol, furosemide, nadolol, spironolactone and triamterene were established and compared in both techniques. Examples of direct urine injection into the separation systems are presented. Drugs overlapping in MLC are well resolved in CZE, while the opposite is true for a limited number of drugs. Some interferences from urine may arise in CZE. The selectivity of analysis would be greatly enhanced by using both techniques, which require only filtration as pre-treatment.  相似文献   

20.
Electrospray ionization (ESI) in combination with Fourier transform ion cyclotron resonance (FTICR) mass spectrometry provides for mass analysis of biological molecules with unrivaled mass accuracy, resolving power and sensitivity. However, ESI FTICR MS performance with on-line separation techniques such as liquid chromatography (LC) and capillary electrophoresis has to date been limited primarily by pulsed gas assisted accumulation and the incompatibility of the associated pump-down time with the frequent ion beam sampling requirement of on-line chromatographic separation. Here we describe numerous analytical advantages that accrue by trapping ions at high pressure in the first rf-only octupole of a dual octupole ion injection system before ion transfer to the ion trap in the center of the magnet for high performance mass analysis at low pressure. The new configuration improves the duty cycle for analysis of continuously generated ions, and is thus ideally suited for on-line chromatographic applications. LC/ESI FTICR MS is demonstrated on a mixture of 500 fmol of each of three peptides. Additional improvements include a fivefold increase in signal-to-noise ratio and resolving power compared to prior methods on our instrument.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号