1.
A strategy for expanding the linear working range in bioanalysis using quantitative high performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) is presented. The strategy involves monitoring multiple product ions. Herein we demonstrate the strategy on a rat plasma assay for a proprietary experimental drug where the linear range is expanded from 2 to 4 orders of magnitude. A primary sensitive ion was monitored to obtain a high sensitivity range calibration curve (0.400 to 100 ng/mL) while a less sensitive secondary ion was monitored to obtain a low sensitivity range calibration curve (90.0 to 4000 ng/mL). Each calibration curve gave acceptable linearity (r >0.990). Quality control samples at low, mid and high levels within each calibration curve demonstrated acceptable precision and accuracy (within 20% for all levels). The technique was successfully applied to rat pre-clinical sample analysis.  相似文献   

2.
Three methods of operating an ion trap mass spectrometer (ITMS) were investigated for the determination of quantitative information by combined capillary GC/MS and GC/MS/MS. Separate regression Lines for a hexynone drug were examined by using bath unlabeled and stable-isotope-labeled internal standards. The ITMS modes of operation examined were (1) the full-scan, rf-voltage-only mode, useful on ion trap detectors as well as on the ITMS, (2) a scan using combined rf and dc voltages (rf/dc) for mass-selective storage analyses, and (3) rf/dc followed by collision-induced dissociation, Results of over 200 analyses in the 0.1–10 ng on-column range, with 5 ng of internal standard, showed that the unlabeled internal standard, separated by retention time on the capillary GC column, gave the best relative standard deviatiod (less than 5% over the range) and linear correlations (r 2 typically > 0.9992).  相似文献   

3.
Miniature toroidal radio frequency ion trap mass analyzer   总被引:1,自引:0,他引:1  
A miniature ion trap mass analyzer is reported. The described analyzer is a 1/5-scale version of a previously reported toroidal radio frequency (rf) ion trap mass analyzer. The toroidal ion trap operates with maximum rf trapping voltages about 1 kVp-p or less; however despite the reduced dimensions, it retains roughly the same ion trapping capacity as conventional 3D quadrupole ion traps. The curved geometry provides for a compact mass analyzer. Unit-mass resolved mass spectra for n-butylbenzene, xenon, and naphthalene are reported and preliminary sensitivity data are shown for naphthalene. The expected linear mass scale with rf amplitude scan is obtained when scanned using a conventional mass-selective instability scan mode combined with resonance ejection.  相似文献   

4.
A fast liquid chromatography-electrospray tandem mass spectrometric (LC-ESI-MS-MS) method by using a monolithic column, gradient elution and ion trap mass spectrometer was developed for 14 forensically interesting and chemically different compounds. All compounds were eluted within 2.5 min and the total analysis time was 5 min including stabilisation time required for the next injection. All the compounds, basics, neutrals and acids were efficiently ionised by positive ion ESI. A laboratory library including MS-MS spectra and retention times was developed and tested. Results with 476 standard samples and 50 authentic samples showed that the compounds studied can be unambiguously identified with the library. A quantitative method was developed for the compounds using external calibration. The evaluation process showed good linearity of the method and reasonable repeatability. Limits of detection ranged from 10.0 to 50.0 ng/ml.  相似文献   

5.
Midazolam (MDZ), a short-acting benzodiazepine, is a widely accepted probe drug for CYP3A phenotyping. Published methods for its analysis have used either therapeutic doses of MDZ, or, if employing lower doses, were mostly unable to quantify the two hydroxy metabolites. In the present study, a sensitive and specific liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the quantitative determination of MDZ and two of its metabolites (1'-hydroxymidazolam (1'-OHMDZ) and 4-hydroxymidazolam (4-OHMDZ)) in human plasma and oral fluid. After liquid-liquid extraction with hexane/dichloromethane (73:27, v/v), the analytes were separated on a Luna C18(2) (100 x 2.1 mm) analytical column using gradient elution. Detection was achieved using tandem mass spectrometry on an ion trap mass spectrometer. Midazolam-d6 was used as internal standard for quantification. The calibration curves were linear (R2 >0.998) between 0.05 and 20 ng/mL for MDZ and both metabolites in both matrices. Using 1 mL samples, the limit of detection was 0.025 ng/mL and the limit of quantification was 0.05 ng/mL for MDZ and the hydroxy metabolites in both matrices. Intra- and inter-day accuracies, determined at three different concentrations, were between 92.1 and 102.3% and the corresponding coefficients of variation were <7.3%. The average recoveries were 90.6%, 86.7% and 79.0% for MDZ, 1'-OHMDZ and 4-OHMDZ in plasma and 95.3%, 96.6% and 86.8% for MDZ, 1'-OHMDZ and 4-OHMDZ, respectively, in oral fluid. The method was successfully applied to a pharmacokinetic study, showing that MDZ and its hydroxy metabolites can be determined precisely in in vivo samples obtained following a single oral or intravenous dose of 2 mg MDZ. The method appears to be useful for CYP3A phenotyping in plasma using sub-therapeutic MDZ doses, but larger studies are needed to test this assumption.  相似文献   

6.
Collision induced dissociation (CID) in a quadrupole ion trap mass spectrometer using the conventional 30 ms activation time is compared with high amplitude short time excitation (HASTE) CID using 2 ms and 1 ms activation times. As a result of the shorter activation times, dissociation of the parent ions using the HASTE CID technique requires resonance excitation voltages greater than conventional CID. After activation, the rf trapping voltage is lowered to allow product ions below the low mass cut-off to be trapped. The HASTE CID spectra are notably different from those obtained using conventional CID and can include product ions below the low mass cut-off for the parent ions of interest. The MS/MS efficiencies of HASTE CID are not significantly different when compared with the conventional 30 ms CID. Similar results were obtained with a two-dimensional (linear) ion trap and a three-dimensional ion trap.  相似文献   

7.
Optimisation of the activation parameters for ion trap mass spectrometric analysis of the chlormequat cation using simplex optimisation enabled the product ion (m/z 58) response to be improved 1000-fold. A comparison of the sensitivity of the optimised ion trap mass spectrometer with that of a triple quadrupole mass spectrometer for liquid chromatography/tandem mass spectrometry (LC/MS/MS) showed that similar limits of detection (LODs) could be achieved. For the MS/MS transition of the (35)Cl precursor to the most abundant product, LODs were 0.8 ng cation mL(-1) (0.004 mg cation kg(-1) pear equivalent) and 1.0 ng cation mL(-1) (0.005 mg cation kg(-1) pear equivalent) on the triple quadrupole and ion trap instrument, respectively.  相似文献   

8.
A very highly sensitive and highly selective liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method was developed to evaluate and quantify a new drug candidate in different biological matrices. Following a simple plasma protein precipitation using acetonitrile, the post-treatment samples were analyzed on a C18 column interfaced with a new generation of triple-quadrupole mass spectrometer. The recently introduced triple-quadrupole mass spectrometer, the TSQ Quantum Ultra, with enhanced mass-resolution capability, demonstrated improved sensitivity (0.05 ng/mL), coupled with suitable accuracy and precision, over a broad linear dynamic range (0.05-1000 ng/mL). A comparison of the assay performance data (dynamic range, calibration curve equation, precision and accuracy) of the enhanced resolution method against a unit resolution method under optimized conditions showed the performance improvement of the enhanced mass resolution method for bioanalytical high-throughput applications. The enhanced mass resolution method herein described was successfully applied to the evaluation of the pharmacokinetic profile of a new drug candidate in rat, rabbit and dog plasma samples.  相似文献   

9.
A new approach to qualitative analysis of ginsenosides in challenging matrices was developed on the basis of high‐performance liquid chromatography/tandem mass spectrometry. Using the extracts from samples of ginseng tea, the approach was validated. Analysis of extracts was carried out using a reversed‐phase chromatography with SB‐C18 sorbent. For compound identification, electrospray ionization and a quadrupole/linear ion trap mass‐spectrometer in different modes were used. A meticulous study of the fragmentation of ginsenosides in the linear ion trap and its application for analysis of these compounds was performed in this work. The accuracy of the identification was proven with standards of ginsenosides Rb1, Rg1, Re, Rf, Rd, Rb2, Rb3 and Rc. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

10.
A hybrid linear ion trap/triple quadrupole mass spectrometer was used to demonstrate the value of collecting full scan qualitative data during quantitative analysis of target compounds. We present examples of the additional information that can be obtained from plasma samples analyzed primarily for target compound concentrations. This information includes detection of circulating metabolites, dosing vehicle, interfering matrix components, and potential interfering drug conjugates. Additionally, the quantitative results from selected reaction monitoring (SRM) analysis and from combined full scan and SRM analysis (SRM/EMS) were compared. The quantitative data in both scan modes are acceptable in terms of sensitivity, accuracy and precision. One can conclude from this work that the hybrid linear ion trap/triple quadrupole mass analyzer can provide in a single analysis both useful qualitative data, and accurate and precise quantitative data from the samples routinely prepared and analyzed for target drug concentrations.  相似文献   

11.
In this paper the transfer of an existing method for the quantitative determination of the anticancer agent ES-285 in human plasma using liquid chromatography tandem mass spectrometry on an API 365 to an API 3000 mass spectrometer is described. The transfer appeared not to be straightforward. Problems arose resulting from carry-over and interferences. In addition, due to the expansion of the calibration range, data ought to be weighted with a different factor to increase the accuracy of the lower concentrations. After finding appropriate solutions for these problems, the lower limit of quantitation could be lowered from 10 to 1 ng/mL for ES-285 in human plasma. The usefulness and necessity of the modified assay was demonstrated by analysis of plasma samples from a patient receiving a low dosage of the drug.  相似文献   

12.
两种微波等离子体炬质谱测定水中铅的对比研究   总被引:1,自引:0,他引:1  
建立了一种新型的能够灵敏分析水中痕量铅的质谱方法,以微波等离子体炬(MPT)为离子源,可无需样品预处理而直接分析水样。样品经雾化和去溶后由MPT的中心管道引入等离子体,离子由国产的四极杆质谱仪(Q-MS)检测,得到铅的MPT特征质谱。定量结果表明,该方法的检出限为20 ng/L,线性范围为200~1 000 ng/L,相对标准偏差(RSD)为5.3%;所得定量指标优于相同条件下商用的线性离子阱质谱(LTQ-MS)测试结果,且四极杆质谱仪上所得的铅离子特征质谱信号更简单、易归属,无需复杂的多级串联质谱加以确认。这种MPT可与国产质谱仪器相结合发展成为一种低成本的现场检测铅的质谱仪器,在环境监控、饮用水检验等方面具有一定的应用价值。  相似文献   

13.
A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for determining the type B fumonisin mycotoxins in corn-based foodstuffs is described. Fumonisins FB1 and FB2 were extracted from a 1 g sample by homogenization with acetonitrile/water (75:25, v/v, 50 mmol/L formic acid, 25 mL final volume) and the extract was defatted on C18 phase. Volumes of 5 mL of crude extracts were cleaned up on Carbograph-4 cartridges. The final solution was analyzed by HPLC with electrospray ionization mass spectrometry in positive ion mode using multiple reaction monitoring with a QqQ linear ion trap mass spectrometer. Recoveries for spiked corn-based foodstuffs ranged from 91-105% (RSD% < or =8%), and method detection limits were < or =2 ng/g for FB1 and < or =1 ng/g for FB2. Two different spiking levels were tested (5000 and 100 ng/g for FB1, 1000 and 20 ng/g for FB2). Quantitation was achieved by an external calibration procedure using matrix-matched standards, with diclofenac added post-cleanup as internal standard for the LC/MS/MS analyses. Calibration curves showed linearity in the concentration range 0.005-5 ng/microL of final extract (0.992 < or = R2< or =0.995). Two other fumonisins, FB3 and FB4, were identified in naturally contaminated samples of corn meal using an information-dependent acquisition protocol that looped three experiments, including neutral loss scan, enhanced resolution scan, and enhanced product ion scan. FB3 and FB4 quantitation was estimated as peak area ratios relative to the FB2 response in view of the lack of both standards. This work also includes an application of the present LC/MS/MS method to some maize and maize-based product samples (corn meal, cornflakes and popcorn) collected from Italian stores. FB1 and FB2 contamination levels exceeding the European Union recommendation were found in 8 out of 15 corn meal samples.  相似文献   

14.
An electrospray ionization tandem mass spectrometry (ESI-MS/MS) library which contains over 5,600 spectra of 1,253 compounds relevant in clinical and forensic toxicology has been developed using a hybrid tandem mass spectrometer with a linear ion trap. Pure compound solutions—in some cases solutions made of tablets—were prepared and 1 to 2,000 ng of each compound were injected into the system using standard reversed-phase analytical columns with gradient elution. To obtain maximum mass spectral information enhanced product ion spectra were acquired with positive and/or negative ionization at low, medium, and high collision energies and additionally applying collision energy spread. In this mode, all product ions generated by the different collision energies are trapped in the linear ion trap prior to their detection. The applicability of the library for other types of hybrid tandem mass spectrometers with a linear ion trap of the same manufacturer as well as a standard triple-quadrupole tandem mass spectrometer has been investigated with a selection of compounds. The spectra of the developed library can be used to create methods for target analysis, either screening methods or quantitative procedures by generating transitions for multiple reaction monitoring. For those procedures, suitable transitions and convenient collision energies are selected from the library. It also has been utilized to identify compounds with a multi target screening approach for clinical and forensic toxicology with a standardized and automated system. The novel aspects compared to our former library produced with a standard triple-quadrupole mass spectrometer are the enlargement of the ESI-MS/MS library and the additional acquisition of spectra with collision energy spread.  相似文献   

15.
各种野外环境的现场检测、现场诊断、流程监控、排放物检测与控制、突发事件的处理、尤其是化学和生物武器的检测等诸多需要现场使用质谱仪的场合都对质谱仪的小型化提出了迫切的要求。小型离子阱具有较高的灵敏度,可进行MS/MS实验,可利用离子-分子反应来识别特殊的化学基团,因而是小型质谱仪的重要质量分析器。本研究对小型离子阱的工作原理作了简要介绍,并以此为依据提出了进行小型离子阱质量校正的方法,推导了相关的公式,还成功地将其应用于自制的小型矩形离子阱质谱仪进行了质量校正,并指出该方法还可用于仪器RF等电学系统性能的检验。  相似文献   

16.
An ion trap source has been designed for use with time-of-flight (TOF) mass analysis. Two thin diaphragms make up a segmented ring electrode; the end cap electrodes are planar wire mesh. The potential field produced by the rf voltage applied between the ring and end cap electrodes resembles that of the cylindrical ion trap. The trapped ion population for ions created by electron impact exhibits linear growth against a first-order loss that has a time constant of about 50 µs; no ion loss occurs when the electron beam is off. The observed value of q z at low-mass cutoff for rf ion storage is ?0.84. Pulsed extraction of all ions is accomplished by switching the trap electrodes from rf to voltages required to provide a linear dc extraction field. The TOF flight path includes a wide energy range reflectron. Better than unit mass resolution is achieved through m/z 500 without collisional ion cooling. With an extraction rate of 1 kHz and a recording rate of 4 spectra per second, a linear working curve is obtained between 36 pg and 18 ng of chlorobenzene delivered chromatographically. The system has demonstrated the potential to achieve a very high sample utilization efficiency at high spectral generation rates.  相似文献   

17.
A capillary electrophoresis apparatus was used as sampler for flow injection analysis (FIA) in tandem mass spectrometry of L-carnitine and its acetyl- and propionyl-metabolites in human plasma. The capillary electrophoresis instrument was coupled to the ion trap mass spectrometer by an electrospray ionization coaxial sheath liquid interface. The electrophoresis capillary introduced the sample directly into the source by applying a prolonged sample injection. The use of the capillary electrophoresis apparatus miniaturised the FIA procedure, substantially reducing the quantities of solvents and samples used, and allowed rapid automated sequential analyses. The method was optimised and validated using a dialyzed human plasma matrix. The plasma samples were analysed after a simple, rapid deproteinisation procedure with acetonitrile and diluted 70 times before direct injection into the mass spectrometer for product ion scan MS/MS analysis in positive ionisation. The total analysis time was 5 min, including capillary preconditioning and acquisition time (3 min). The method was sensitive, allowing the determination of L-, L-acetyl- and L-propionyl-carnitines at 140, 14 and 3.6 nM concentrations (injected values) corresponding to lower limit of quantitation values in plasma of 10, 1 and 0.25 microM, respectively. The method was processed for full validation and applied to the analysis of L-carnitine and its short chain derivatives in human plasma samples.  相似文献   

18.
The effects of applied voltages and reaction times on negative ion chemical ionization in the quadrupole ion trap are investigated. Mass-selected ejection of undesired reagent ions and selective mass storage of only negative ions are required for practical negative ion chemical ionization. This is achieved by application of rf and dc voltages to the ring electrode to control the mass-to-charge ratios one polarity) of ions stored, as well as by application of a supplemental rf voltage applied across the endcap electrodes to selectively eject ions of a particular mass-to-charge ratio. Even with careful control of these parameters, negative chemical ionization is not as sensitive as electron ionization and positive chemical ionization because of the lack of thermal electrons in the ion trap. Mass selection of the hydroxide anion as a reagent ion and exclusion of all positive ions provide [M ? H]? ions with little or no fragmentation for a wide variety of compounds.  相似文献   

19.
Capillary liquid chromatography (LC) using a 320 microns column and a flow rate of 10 microL/min has been coupled to an ion trap mass spectrometer using electrospray ionisation (ESI) to enable the rapid and effective identification of metabolites in urine, following oral administration of a novel human neutrophil elastase inhibitor, GW311616. Metabolites were identified from their mass (MS) spectra and tandem (MS/MS) mass spectra using minimal sample (1 microL of urine) and no sample pretreatment. Sensitivity assessment has shown that both molecular weight and structural information is obtainable on as little as 5 pg of compound, making the capillary LC/ion trap system as described an ideal analytical tool for the detection and characterisation of low level metabolites in biofluids (particularly when sample volume is limited). This level of detection was unattainable using a triple quadrupole mass spectrometer operating in full-scan mode, although 200 fg on column was detected using selected reaction monitoring target analysis.  相似文献   

20.
There is a continuing need for increased throughput in the evaluation of new drug entities in terms of their pharmacokinetic (PK) parameters. This report describes an alternative procedure for increasing the throughput of plasma samples assayed in one overnight analysis: the use of parallel high performance liquid chromatography (HPLC) combined with tandem mass spectrometry (parallel LC/MS/MS). For this work, two HPLC systems were linked so that their combined effluent flowed into one tandem MS system. The parallel HPLC/APCI-MS/MS system consisted of two Waters 2690 Alliance systems (each one included an HPLC pump and an autosampler) and one Finnigan TSQ 7000 triple quadrupole mass spectrometer. Therefore, the simultaneous chromatographic separation of the plasma samples was carried out in parallel on two HPLC systems. The MS data system was able to deconvolute the data to calculate the results for the samples. Using this system, 20 compounds were tested in one overnight assay using the rapid rat PK screening model which includes a total of 10 standards plus samples and two solvent blanks per compound tested. This application provides an additional means of increasing throughput in the drug discovery PK assay arena; using this approach a two-fold increase in throughput can be achieved in the assay part of the drug discovery rat PK screening step.  相似文献   