首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
The assignment of the mass (m) value from the m/z value for ions with a multiple number of charges (z) in electrospray mass spectra usually utilizes multiple peaks of the same m but different z values, or unit-mass—separated isotopic peaks of the same z value from high resolution spectra. The latter approach is also feasible with much less resolving power using adduct ions of much higher mass separation. The application of this to mixture spectra containing many masses, such as spectra from tandem mass spectrometry (MS/MS) ion dissociation, does not appear to have been pointed out previously. Thus, replacing two protons by one Cu2+ ion increases the mass by 61.5 Da, with this shift providing a mass scale for assignment of m and z from this pair of m/z values. The more common Na+ adduct peaks provide a 22.0 Da separation, of utility for 1000 resolving power only below approximately 10 kDa. Further, collisional dissociation lowers the degree of Cu2+ adduction in the resulting sequence-specific fragment ions much less than that of the corresponding Na+ adducts, making the Cu2+ adducts far more useful for m and z determination in MS/MS studies.  相似文献   

2.
A copoly (DL-lactic/glycolic acid) (PLGA), with a weight-average molecular weight of about 8400, has been characterized using fast atom bombardment (FAB)-tandem mass spectrometry in order to determine the sequence. Because of the large molecular size, PLGA was partially hydrolyzed and the terminal hydroxyl groups in the resulting oligomer mixture acetylated as the indicator. The FAB spectrum of this sample showed a complex ion signal pattern containing monomer to octamer. Diagnostic product ions containing useful information for sequence determination were observed in collision-induced dissociation-MS/MS and MS/MS/MS of these oligomer ions. The results of analysis for dimers through pentamers showed that they have random sequences of lactic and glycolic acid, suggesting that the whole structure of PLGA also has a random sequence.  相似文献   

3.
Ultra-performance liquid chromatography-quadrupole-time-of-flight mass spectrometry (UPLC-Q-TOF-MS) is an effective technique for analysis of complex samples with offering rapid, efficient separation in combination with accurate mass measurement and tandem mass spectrometry (MS/MS). This paper exploits this technique to identify the alkaloids in corydalis yanhusuo, an important antalgic Traditional Chinese Medicine (TCM). The mass spectral fragmentation behavior of one tertiary alkaloid and two quaternary alkaloids was studied in detail. Low-abundance product ions of tertiary and quaternary alkaloids were investigated and compared between each other. Sixteen alkaloids were screened out by using a systematic screening method developed in our laboratory; structures of eight therein were identified by characteristic UV absorption spectrum and positive ion mode of Q-TOF-MS/MS; and two of them were discovered for the first time in corydalis yanhusuo to our knowledge. This research demonstrates the potential of UPLC-Q-TOF-MS in structural characterization and identification of components in traditional Chinese herbal medicines.  相似文献   

4.
Dramatically different fragmentation patterns are obtained for 4-ethyl-2,6,7-trioxa-1-phosphabicyclo-[2.2.2]octane-1-oxide upon electron ionization (EI) and for the corresponding molecular ion on collision-induced dissociation (CID). Two reasons for this behaviour have been discovered. (i) Irreversible multistep isomerization of the molecular ions occurs prior to collisional activation in mass spectrometry/mass spectrometry (MS/MS). Isomerization reactions have been characterized by isotopic labelling and by examining structures of relevant unlabelled and labelled fragment ions by MS/MS. The extent of isomerization can be controlled by varying the amount of internal energy of the molecular ions. This has been done by changing the number of thermalizing collisions which the ions undergo with neutral molecules in the ion source. (ii) When multiple collisions are used to dissociate the molecular ions, the initially stable fragmentation products undergo extensive further decomposition. As a result, abundant phosphorus-containing fragment ions are obtained for the bicyclic phosphate in high-pressure CID, whereas electron ionization leads to predominant hydrocarbon ions. A minor change in the structure of this molecule has major effects on the fragmentation behaviour: high- and low-energy collisional activation spectra of the molecular ion of the corresponding phosphite are identical with the 12 e V EI mass spectrum of the neutral.  相似文献   

5.
Findings of illegal hormone preparations such as syringes, bottles, cocktails, and so on, are an important information source for the nature of the current abuse of anabolic steroids and related compounds as growth-promoting agents in cattle. A new screening method for steroids in cocktails is presented based on liquid chromatography (LC) with diode-array UV-absorbance detection and electrospray ionization time-of-flight mass spectrometry (ESI-TOFMS). Accurate mass measurements were performed at a mass resolution of 4000 using continuous introduction of a lock mass through a second (electro)sprayer. Similar experiments were carried out using dual-sprayer quadrupole time-of-flight mass spectrometry (ESI-QTOFMS/MS) at a mass resolution of 10 000 with data-dependent MS/MS acquisition; i.e. beyond an intensity threshold for the [M + H](+) ions, MS/MS spectra were automatically acquired at three different collision energies. Elemental compositions were calculated for precursor and product ions and it is shown that the combined information from LC retention behavior, UV spectra, elemental compositions, and accurate mass MS/MS spectra yield a fast impression of the steroids present in the complex mixture. Using a new software tool for structure elucidation of MS/MS spectra, an additional non-steroidal additive was identified as well.  相似文献   

6.
We have acquired multi-stage mass spectra (MSn) of four branched N-glycans derived from human serum IgG by matrix-assisted laser desorption/ionization quadrupole ion trap time-of-flight mass spectrometry (MALDI-QIT-TOF-MS) in order to demonstrate high sensitivity structural analysis. [M+H]+ and [M+Na]+ ions were detected in the positive mode. The detection limit of [M+Na]+ in MS/MS and MS3 measurements for structural analysis was found to be 100 fmol, better than that for [M+H]+. The [M+H]+ ions subsequently fragmented to produce predominantly a Y series of fragments, whereas [M+Na]+ ions fragmented to give a complex mixture of B and Y ions together with some cross-ring fragments. Three features of MALDI-QIT-CID fragmentation of [M+Na]+ were cleared by the analysis of MS/MS, MS3 and MS4 spectra: (1) the fragment ions resulting from the breaking of a bond are more easily generated than that from multi-bond dissociation; (2) the trimannosyl-chitobiose core is either hardly dissociated, easily ionized or it is easy to break a bond between N-acetylglucosamine and mannose; (3) the fragmentation by loss of only galactose from the non-reducing terminus is not observed. We could determine the existence ratios of candidates for each fragment ion in the MS/MS spectrum of [M+Na]+ by considering these features. These results indicate that MSn analysis of [M+Na]+ ions is more useful for the analysis of complicated oligosaccharide structures than MS/MS analysis of [M+H]+, owing to the higher sensitivity and enhanced structural information. Furthermore, two kinds of glycans, with differing branch structures, could be distinguished by comparing the relative fragment ion abundances in the MS3 spectrum of [M+Na]+. These analyses demonstrate that the MSn technology incorporated in MALDI-QIT-TOF-MS can facilitate the elucidation of structure of complex branched oligosaccharides.  相似文献   

7.
Isobaric product ions cannot be differentiated by exact mass determinations, although in some cases deuterium labeling can provide useful structural information for identifying isobaric ions. Proposed fragmentation pathways of fentanyl were investigated by electrospray ionization ion trap mass spectrometry coupled with deuterium labeling experiments and spectra of regiospecific deuterium labeled analogs. The major product ion of fentanyl under tandem mass spectrometry (MS/MS) conditions (m/z 188) was accounted for by a neutral loss of N‐phenylpropanamide. 1‐(2‐Phenylethyl)‐1,2,3,6‐tetrahydropyridine (1) was proposed as the structure of the product ion. However, further fragmentation (MS3) of the fentanyl m/z 188 ion gave product ions that were different from the product ion in the MS/MS fragmentation of synthesized 1, suggesting that the m/z 188 product ion from fentanyl includes an isobaric structure different from the structure of 1. MS/MS fragmentation of fentanyl in deuterium oxide moved one of the isobars to 1 Da higher mass, and left the other isobar unchanged in mass. Multistage mass spectral data from deuterium‐labeled proposed isobaric structures provided support for two fragmentation pathways. The results illustrate the utility of multistage mass spectrometry and deuterium labeling in structural assignment of isobaric product ions. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

8.
A new method has been developed to study the dissociation patterns of singly protonated peptides by using a quadrupole ion trap mass spectrometer. The new approach involves using boundary-activated dissociation to characterize the ease of dissociation of peptide ions. Insight can be gained into the effect of specific peptide sequences on the dissociation energetics of protonated peptides. Increased knowledge of the effects of specific sequences on the dissociation patterns of peptide ions should improve the ability to interpret complex spectra from tandem mass spectrometry (MS/MS) experiments. This method has confirmed the previously observed increase in the energy needed for the dissociation of peptide ions containing basic residues. In addition, this technique has revealed the effect of the location of proline residues on the dissociation energetics of peptides with this amino acid.  相似文献   

9.
Recently discovered ionization methods for use in mass spectrometry (MS), are widely applicable to biological materials, robust, and easy to automate. Among these, matrix assisted ionization vacuum (MAIV) is astonishing in that ionization of low and high-mass compounds are converted to gas-phase ions with charge states similar to electrospray ionization simply by exposing a matrix:analyte mixture to the vacuum of a mass spectrometer. Using the matrix compound, 3-nitrobenzonitrile, abundant ions are produced at room temperature without the need of high voltage or a laser. Here we discuss chemical analyses advances using MAIV combined with ion mobility spectrometry (IMS) real time separation, high resolution MS, and mass selected and non-mass selected MS/MS providing rapid analyte characterization. Drugs, their metabolites, lipids, peptides, and proteins can be ionized simultaneously from a variety of different biological matrixes such as urine, plasma, whole blood, and tissue. These complex mixtures are best characterized using a separation step, which is obtained nearly instantaneously with IMS, and together with direct ionization and MS or MS/MS provides a fast analysis method that has considerable potential for non-targeted clinical analyses.  相似文献   

10.
High field asymmetric waveform ion mobility spectrometry (FAIMS) provides atmospheric pressure, room temperature, low-resolution separation of gas-phase ions. The FAIMS analyzer acts as an ion filter that can continuously transmit one type of ion, independent of m/z. The combination of FAIMS with electrospray ionization and mass spectrometry (ESI-FAIMS-MS) is a powerful technique and is used in this study to investigate the cluster ions of leucine enkephalin (YGGFL). Separation by FAIMS of leucine enkephalin ions having the same m/z (m/z 556.5), [M + H]+ and [2M + 2H]2+, was observed. In addition, four complex ions of leucine enkephalin, [2M + H]+, [4M + 2H]2+, [6M + 3H]3+, and [8M + 4H]4+, all having m/z 1112, were shown to be separated in FAIMS. Fragmentation of ions as the result of harsh conditions within the mass spectrometer interface (FAIMS-MS) was shown to provide similar information to that obtained from MS/MS experiments in conventional ESI-MS.  相似文献   

11.
Tandem mass spectrometry (MS/MS) of peptides plays a key role in the field of proteomics, and an understanding of the fragmentation mechanisms involved is vital for data interpretation. Not all the fragment ions observed by low-energy collision-induced dissociation of protonated peptides are readily explained by the generally accepted structures for a- and b-ions. The possibility of a macrocyclic structure for b-type ions has been recently proposed. In this study, we have undertaken investigations of linear protonated YAGFL-NH(2), N-acetylated-YAGFL-NH(2), and cyclo-(YAGFL) peptides and their fragments using a combination of ion mobility (IM) separation and mass spectrometry. The use of IM in this work both gives insight into relative structural forms of the ion species and crucial separation of isobaric species. Our study provides compelling evidence for the formation of a stable macrocyclic structure for the b(5) ion generated by fragmentation of protonated linear YAGFL-NH(2). Additionally we demonstrate that the a(4) ion fragment of protonated YAGFL-NH(2) has at least two structures; one of which is attributable to a macrocyclic structure on the basis of its subsequent fragmentation. More generally, this work emphasizes the value of combined IM-MS/MS in probing the detailed fragmentation mechanisms of peptide ions, and illustrates the use of combined ion mobility/collisional activation/mass spectrometry analysis in achieving an effective enhancement of the resolution of the mobility separator.  相似文献   

12.
The fragmentation reactions of protonated oligoalanines (trialanine, tetraalanine and pentaalanine) and the fragments present in the electrospray ionization (ESI) mass spectrum of polyalanine have been studied by collisionally activated dissociation (CAD) mass spectrometry (MS(2) and MS(3) experiments). The MS(n) experiments provided strong evidence that the m/z 71n+1 ion series in the ESI mass spectrum of polyalanine is a b(n) series. These ions are formed via the b(n) -y(m) pathway of amide bond cleavage, which results in the formation of a proton-bound complex of an oxazolone and a peptide/amino acid. Also, the MS(2) spectra of the b(n) series from polyalanine revealed that the chain length of b(n) ions influences significantly the dissociations taking place. For example, b(n) ions start losing H(2)O at n ≥5 and the losses of CO and CO+NH(3) decrease in intensity from b(2) to b(15). The elimination of H(2)O+NH(3) and the elimination of 61 mass (HN=C=O+H(2)O) commence with b(6); their abundances initially increase up to ~ b(8)-b(9) and then gradually decrease until b(15) (largest fragment studied). The tandem mass spectrometry experiments help to elucidate the dissociation mechanisms of the observed structures of biopolymer fragments.  相似文献   

13.
High‐field asymmetric waveform ion mobility spectrometry (FAIMS) is an ion‐filtering technique recently adapted for use with liquid chromatography/mass spectrometry (LC/MS) to remove interferences during analysis of complex matrices. This is the first systematic study of a series of singly charged tetraalkylammonium ions by FAIMS‐MS. The compensation voltage (CV) is the DC offset of the waveform which permits the ion to emerge from FAIMS and it was determined for each member of the series under various conditions. The electrospray ionization conditions explored included spray voltage, vaporizer temperature, and sheath and auxiliary gas pressure. The FAIMS conditions explored included carrier gas flow rate, electrode temperature and composition of the carrier gas. Optimum desolvation was achieved using sufficient carrier gas (flow rate ≥2 L/min) to ensure stable response. Low‐mass ions (m/z 100–200) are more susceptible to changes in electrode temperature and gas composition than high mass ions (m/z 200–700). As a result of this study, ions are reliably analyzed using standard FAIMS conditions (dispersion voltage ?5000 V, carrier gas flow rate 3 L/min, 50% helium/50%nitrogen, inner electrode temperature 70°C and outer electrode temperature 90°C). Variation of FAIMS conditions may be of great use for the separation of very low mass tetraalkylammonium (TAA) ions from other TAA ions. The FAIMS conditions do not appear to have a major effect on higher mass ions. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
The chemical structure of lipid A, isolated by mild acid hydrolysis from a rough mutant and a wild strain of Aeromonas salmonicida lipopolysaccharide, was investigated using electrospray ionization quadrupole time-of-flight (QqToF) hybrid tandem mass spectrometry and showed a great degree of microheterogeneity. The chemical structure of the main constituent of this heterogeneous mixture was identified as a beta-D-(1 --> 6) linked D-glucosamine disaccharide substituted by two phosphate groups, one being bound to the non-reducing end at position O-4' and the other to the position O-1 of the reducing end of the D-glucosamine disaccharide. The location of the fatty acids linked to the disaccharide backbone was established by identifying diagnostic ions in the conventional QqToF-MS scan. Low-energy collision tandem mass spectrometry analysis of the selected precursor diagnostic ions confirmed, unambiguously, their proposed molecular structures. We have established that myristyloxylauric (C14:0(3-O(12:0))) acid residues were both N-2' and O-3' linked to the non-reducing end of the D-GlcN residue, and that two 3-hydroxymyristic (C14:0(3-OH)) acid chains acylated the remaining positions of the reducing end. The MS and MS/MS data obtained allowed us to determine the complex molecular structure of lipid A. The QqToF-MS/MS instrument has shown excellent superiority over a conventional quadrupole-hexapole-quadrupole tandem instrument which failed to fragment the selected precursor ion.  相似文献   

15.
Mass spectrometric analysis of a banyan endophyte, Bacillus subtilis K1, extract showing broad spectrum antifungal activity revealed a complex mixture of lipopeptides, iturins, surfactins, and fengycins. Fractionation by reversed-phase high performance liquid chromatography (HPLC) facilitated a detailed analysis of fengycin microheterogeneity. Matrix assisted laser desorption ionization (MALDI) and electrospray ionization (ESI) mass spectrometric studies permitted the identification of several new fengycin variants. Four major sites of heterogeneity are identified: (1) N-terminus ??-hydroxy fatty acid moiety, where chain length variation and the presence of unsaturation occur, (2) position 6 (Ala/Val/Ile/Leu), (3) position 10 (Val/Ile) within the macrocyclic ring, and (4) Gln to Glu replacement at position 8, resulting in fengycin variants that differ in mass by 1?Da. Diagnostic fragment ions provide a quick method for localizing the sites of variation in the macrocycle or the linear segment. Subsequent establishment of the sequences is achieved by MS/MS analysis of linear fengycin species produced by hydrolysis of the macrocyclic lactone. Unsaturation in the fatty acid chain and the presence of linear precursors in the B. subtilis K1 extract are also established by mass spectrometry. The anomalous distribution of intensities within isotopic multiplets is a diagnostic for Gln/Glu replacements. High resolution mass spectrometry facilitates the identification of fengycin species differing by 1?Da by localizing the variable position (Gln8/Glu8) in the fengycin variants.  相似文献   

16.
Procedures that allow the realization of resonance electron capture (REC) mode on a commercial triple-quadrupole mass spectrometer, after some simple modifications, are described. REC mass spectrometry (MS) and tandem mass spectrometry (MS/MS) experiments were performed and spectra for some compounds were recorded. In particular, the charge-remote fragmentation (CRF) spectra of [M - H](-) ions of docosanoic and docosenoic acids under low-energy collisionally activated dissociation (CAD) conditions were obtained, and showed that there were no significant differences for [M - H](-) ions produced at different resonances (i.e. for [M - H](-) ions with different structures). This observation was explained on the basis of results obtained from deuterium-labeled fatty acids, which showed that different CRF ions (but with the same m/z value in the absence of labels) could be produced by different mechanisms, and all of them were obviously realized under CAD conditions that made spectra practically indistinguishable. The other example, which compared the REC-MS/MS spectrum of [M - H](-) ions and EI-MS/MS spectrum of M(+.) ions of daidzein, demonstrated the potential of the REC-MS/MS technique for more complex structure elucidation.  相似文献   

17.
An integrated differential approach to the characterization of complex mixtures is presented which includes the targeting of liquid chromatography (LC) peaks for identification using characteristic UV adsorption of the LC peak, subsequent molecular weight and formula determination using accurate mass LC mass spectrometry (MS), and structure characterization using accurate mass LC-tandem mass spectrometry. The use of differential UV adsorption aids in narrowing the scope of the study to only specific peaks of interest. Accurate mass measurement of the molecular ion species provides molecular weight information as well as atomic composition information. The tandem MS (MS/MS) spectra provide fragmentation information which allows for structural characterization of each component. Accurate mass assignment of each of the fragment ions in the MS/MS spectrum provides atomic composition for each of the fragment ions and thus further aids in the structural characterization. These experiments are facilitated through the use of on-line LC-MS and LC-MS/MS with in-line UV detection. A synthetic toxic oil (STO) related to Toxic Oil Syndrome is studied with a focus on possible contaminants resulting from the interaction of aniline, used as a denaturant, with the normal components of the oil. A differential analysis between the STO and a control oil is performed. LC peaks were targeted using UV absorbance to indicate the possible presence of the aniline moiety. Further differential analysis was performed through the determination of the MS signals associated with each component separated on the LC. Finally, the MS/MS data was also used to determine if the fragmentation of the targeted components indicated the presence of aniline. The MS/MS and accurate mass data were used to assign the structures for the targeted components.  相似文献   

18.
Highly complex protein mixtures can be analyzed after proteolysis using liquid chromatography/mass spectrometry (LC/MS). In an LC/MS run, intense peptide ions originating from high-abundance proteins are preferentially analyzed using tandem mass spectrometry (MS(2)), so obtaining the MS(2) spectra of peptide ions from low-abundance proteins is difficult even if such ions are detected. Furthermore, the MS(2) spectra may produce insufficient information to identify the peptides or proteins. To solve these problems, we have developed a real-time optimization technique for MS(2), called the Information-Based-Acquisition (IBA) system. In a preliminary LC/MS run, a few of the most intense ions detected in every MS spectrum are selected as precursors for MS(2) and their masses, charge states and retention times are automatically registered in an internal database. In the next run, a sample similar to that used in the first run is analyzed using database searching. Then, the ions registered in the database are excluded from the precursor ion selection to avoid duplicate MS(2) analyses. Furthermore, real-time de novo sequencing is performed just after obtaining the MS(2) spectrum, and an MS(3) spectrum is obtained for accurate peptide identification when the number of interpreted amino acids in the MS(2) spectrum is less than five. We applied the IBA system to a yeast cell lysate which is a typical crude sample, using a nanoLC/ion-trap time-of flight (IT/TOF) mass spectrometer, repeating the same LC/MS run five times. The obtained MS(2) and MS(3) spectra were analyzed by applying the Mascot (Matrix Science, Boston, MA, USA) search engine to identify proteins from the sequence database. The total number of identified proteins in five LC/MS runs was three times higher than that in the first run and the ion scores for peptide identification also significantly increased, by about 70%, when the MS(3) spectra were used, combined with the MS(2) spectra, before being subjected to Mascot analysis.  相似文献   

19.
The rate of successful identification of peptide sequences by tandem mass spectrometry (MS/MS) is adversely affected by the common occurrence of co-isolation and co-fragmentation of two or more isobaric or isomeric parent ions. This results in so-called `chimera spectra’, which feature peaks of the fragment ions from more than a single precursor ion. The totality of the fragment ion peaks in chimera spectra cannot be assigned to a single peptide sequence, which contradicts a fundamental assumption of the standard automated MS/MS spectra analysis tools, such as protein database search engines. This calls for a diagnostic method able to identify chimera spectra to single out the cases where this assumption is not valid. Here, we demonstrate that, within the recently developed two-dimensional partial covariance mass spectrometry (2D-PC-MS), it is possible to reliably identify chimera spectra directly from the two-dimensional fragment ion spectrum, irrespective of whether the co-isolated peptide ions are isobaric up to a finite mass accuracy or isomeric. We introduce ‘3-57 chimera tag’ technique for chimera spectrum diagnostics based on 2D-PC-MS and perform numerical simulations to examine its efficiency. We experimentally demonstrate the detection of a mixture of two isomeric parent ions, even under conditions when one isomeric peptide is at one five-hundredth of the molar concentration of the second isomer.  相似文献   

20.
A novel method for peptide sequencing by matrix-assisted laser desorption/ionization mass spectrometry with a time-of-flight/time-of-flight analyzer (MALDI-TOF/TOF) is presented. A stable isotope label introduced in the peptide N-terminus by derivatization, using a 1:1 mixture of acetic anhydride and deuterated acetic anhydride, allows for easy and unambiguous identification of ions belonging either to the N- or the C-terminal ion series in the product ion spectrum, making sequence assignment significantly simplified. The good performance of this technique was shown by successful sequencing of the contents of several peptide maps. A similar approach was recently applied to nanoelectrospray ionization (nanoESI) and nano-liquid chromatography/tandem mass spectrometry (LC/MS/MS). The MALDI-TOF/TOF technique allows for fast, direct sequencing of modified peptides in proteomics samples, and is complementary to the nanoESI and nanoLC/MS/MS approaches.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号