首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
Methanol diffusion in two polymer electrolyte membranes, Nafion 117 and BPSH 40 (a 40% disulfonated wholly aromatic polyarylene ether sulfone), was measured using a modified pulsed field gradient NMR method. This method allowed for the diffusion coefficient of methanol within the membrane to be determined while immersed in a methanol solution of known concentration. A second set of gradient pulses suppressed the signal from the solvent in solution, thus allowing the methanol within the membrane to be monitored unambiguously. Over a methanol concentration range of 0.5–8 M, methanol diffusion coefficients in Nafion 117 were found to increase from 2.9 × 10−6 to 4.0 × 10−6 cm2 s−1. For BPSH 40, the diffusion coefficient dropped significantly over the same concentration range, from 7.7 × 10−6 to 2.5 × 10−6cm2 s−1. The difference in diffusion behavior is largely related to the amount of solvent sorbed by the membranes. Increasing the methanol concentration results in an increase in solvent uptake for Nafion 117, while BPSH 40 actually excludes the solvent at higher concentrations. In contrast, diffusion of methanol measured via permeability measurements (assuming a partition coefficient of 1) was lower (1.3 × 10−6 and 6.4 × 10−7 cm2 s−1 for Nafion 117 and BPSH 40 respectively) and showed no concentration dependence. The differences observed between the two techniques are related to the length scale over which diffusion is monitored and the partition coefficient, or solubility, of methanol in the membranes as a function of concentration. For the permeability measurements, this length is equal to the thickness of the membrane (178 and 132 μm for Nafion 117 and BPSH 40 respectively) whereas the NMR method observes diffusion over a length of approximately 4–8 μm. Regardless of the measurement technique, BPSH 40 is a greater barrier to methanol permeability at high methanol concentrations.  相似文献   

2.
Fenoterol and salbutamol were determined by electrogenerated chemiluminescence (ECL) coupled with flow injection analysis (FIA), using Ru(bpy)32+ as the luminescent substance. Fenoterol and salbutamol oxidize together with the ruthenium 2,2-bipyridyl at a platinum electrode, which leads to an increase in the luminescent intensity, and this increase is proportional to the analyte concentration. For fenoterol a linear calibration curve within the range from 1.0 × 10−5 to 1.0 × 10−4 mol l−1 was obtained with a correlation coefficient of 0.998 (n = 5) and for salbutamol the linear analytical curve was also obtained in this range with a correlation coefficient of 0.995 (n = 5). The relative standard deviation was estimated as ≤2.5% for 3 × 10−5 mol l−1 for fenoterol solution and as ≤1.3% for 5.0 × 10−5 mol l−1 salbutamol solution for 15 successive injections. The limit of detection for fenoterol was 2.4 × 10−7 mol l−1 and for salbutamol was 4.0 × 10−7 mol l−1. Fenoterol and salbutamol were successfully determined in drug tablets and the soluble components of the matrix did not interfere in the luminescent emission. The results obtained using the luminescent methodology were not statistically different from those obtained by UV-spectrophotometry at 95% confidence level.  相似文献   

3.
Rate coefficients for the reactions of cyclohexadienyl (c-C6H7) radicals with O2 and NO were measured at 296 ± 2 K. The c-C6H7 radicals were detected selectively by laser-induced fluorescence. The rate coefficient for the reaction of c-C6H7 with O2, (4.4 ± 0.5) × 10−14 cm3 molecule−1 s−1, was independent of the bath-gas (He) pressure (13–80 Torr). In the reaction of c-C6H7 with NO, thermal equilibrium among c-C6H7, NO, and C6H7NO was observed. The forward and reverse reactions were in the falloff region, and the equilibrium constant was (1.5 ± 0.6) × 10−15 cm3 molecule−1.  相似文献   

4.
Trace amounts of nickel(II) can function as a trigger (=reaction initiator) in an autocatalytic reaction with the sodium sulfite/hydrogen peroxide system. Based on this finding, sub-μg L−1 levels of nickel(II) were determined by a time measurement using the autocatalytic reaction. The detection range using the above method was 10−9–10−5 M, the detection limit (3σ) was 8.1 × 10−10 M (0.047 μg L−1), and the relative standard deviation was 2.66% at nickel(II) concentration of 10−7 M (n = 7). This method was applied to length detection-flow injection analysis. The detection range for the flow injection analysis was 2 × 10−9–2 × 10−3 M. The detection limit (3σ) was 1.4 × 10−9 M (0.082 μg L−1), and the relative standard deviation was 1.86 at initial nickel(II) concentration of 10−6 M (n = 7).  相似文献   

5.
A series of hydroxyl-conducting anion-exchange membranes were prepared by blending chloroacetylated poly(2,6-dimethyl-1,4-phenylene oxide) (CPPO) with bromomethylated poly(2,6-dimethyl-1,4-phenylene oxide) (BPPO), and their fuel cell-related performances were evaluated. The resulting membranes exhibited high hydroxyl conductivities (0.022–0.032 S cm−1 at 25 °C) and low methanol permeability (1.35 × 10−7 to 1.46 × 10−7 cm2 s−1). All the blend membranes proved to be miscible or partially miscible under the investigations of scanning electron microscopy (SEM) and differential scanning calorimeters (DSC). By condition optimization, the blend membranes with 30–40 wt% CPPO are recommended for application in direct methanol alkaline fuel cells because they showed low methanol permeability, excellent mechanical properties and comparatively high hydroxyl conductivity.  相似文献   

6.
Pentaerythrityl tetraethylenediamine (PETEDA) dendrimer was synthesized from pentaerythrityl tetrabromide and ethylenediamine. Its molecular structure was characterized by elemental analysis, Fourier transform infrared resonance (FT-IR) and hydrogen nuclear magnetic resonance (1H NMR) spectroscopy. The composite membranes for selectively permeating CO2 were prepared by using PETEDA-PVA blend polymer as the active layer and polyethersulfone (PES) ultrafiltration membrane as the support layer and their permselectivity was tested by pure CO2 and CH4 gases and the gas mixture containing 10 vol.% CO2 and 90 vol.% CH4, respectively. For pure gases, the membrane containing 78.6 wt% PETEDA and 21.4 wt% PVA in the blend has a CO2 permeance of 8.14 × 10−5 cm3 (STP) cm−2 s−1 cmHg−1 and CO2/CH4 selectivity of 52 at 143.5 cmHg feed gas pressure. While feed gas pressure is 991.2 cmHg, CO2 permeance reaches 3.56 × 10−5 cm3 (STP) cm−2 s−1 cmHg−1 and CO2/CH4 selectivity is 19. For the gas mixture, the membrane has a CO2 permeance of 6.94 × 10−5 cm3 (STP) cm−2 s−1 cmHg−1 with a CO2/CH4 selectivity of 33 at 188.5 cmHg feed gas pressure, and a CO2 permeance of 3.29 × 10−5 cm3 (STP) cm−2 s−1 cmHg−1 with a CO2/CH4 selectivity of 7.5 at a higher feed gas pressure of 1164 cmHg. A possible gas transport mechanism in the composite membranes is proposed by investigating the permeating behavior of pure gases and the gas mixture and analyzing possible reactions between CO2/CH4 gases and the PETEDA-PVA blend polymer. The effect of PETEDA content in the blend polymer on permselectivity of the composite membranes was investigated, presenting that CO2 permeance and CO2/CH4 selectivity increase and CH4 permeance decreases, respectively with PETEDA content. This is explained by that with increasing PETEDA content, the carrier content increases, and the crystallinity and free volume of the PETEDA-PVA blend decrease that were confirmed by the experimental results of X-ray diffraction spectra (XRD) and positron annihilation lifetime spectroscopy (PALS).  相似文献   

7.
Flow injection visible diffuse reflectance quantitative analysis of nickel   总被引:1,自引:0,他引:1  
Flow injection (FI) methodology, using diffuse reflectance in the visible region of the spectrum, for the analysis of nickel, precipitated in the form of dimethylglyoximate, is presented. A reflectance cell, constructed in polytetrafluoroethylene, using a LED (light emitting diode) as light source and a LDR (light dependent resistor) as detector, is described. The analytical signal (S) correlates with nickel concentration (C) between 1.6 × 10−4 and 6.6 × 10−4 mol L−1. This correlation is described by the equation S = −1.108 + 3.314 × 104C − 2.081 × 107C2 (r = 0.9996). The experimentally observed limit of detection is about 1.3 × 10−4 mol L−1, as in lower concentrations the formation of precipitate is not observed. The experimental quantitation limit is about 1.6 × 10−4 mol L−1. The mean R.S.D. (relative standard deviation) is about 2.7%. Samples containing nickel were analyzed and the results obtained in this method were compared with those of other methods using the statistical Student's t-test.  相似文献   

8.
Various amino acid derivatives of monascus pigments were synthesized. The effects of pigment derivatives on the pigment adsorption ratio, electrophoretic mobility (EPM) of bacterial cells, and antibacterial activity were investigated under varying conditions of pigment type, pigment concentration, pH, and ionic strength. Two hydrophobic and two hydrophilic derivatives were selected as model pigments. There was a close relationship between the antimicrobial activity and the pigment adsorption ratio. Against Escherichia coli, the hydrophobic l-Tyr and l-Phe derivatives (log P = 3.18 and 3.57) exhibited high antimicrobial activities (MIC = 8 and 16 mg/L) and high cellular adsorption ratios (9.6 and 10.9 mg/L). The hydrophilic l-Glu and l-Asn derivatives (log P = 1.40 and 0.47) exhibited low activities (MIC = 64 and 128 mg/L) and low adsorption ratios (4.7 and 4.0 mg/L). The electrophoretic mobility of 11 different bacteria varied between −1.93 × 10−8 and −1.19 × 10−8 m2 V−1 s−1 regardless of Gram+ or Gram. The l-Phe derivative showed low MIC values (high antimicrobial activities) against bacteria with a high electrophoretic mobility. A positive linearity between the pigment adsorption ratio and the electrophoretic mobility was established. When the four pigment derivatives were added to E. coli solutions, the electrophoretic mobility of cells in all cases sharply increased with an increasing pigment concentration. The mobility value was high for hydrophobic pigment derivatives in descending order of l-Phe (0.8 × 10−8 m2 V−1 s−1), l-Tyr (0.68 × 10−8 m2 V−1 s−1), l-Glu (0.46 × 10−8 m2 V−1 s−1), and l-Asn (0.44 × 10−8 m2 V−1 s−1). Additional adsorption of the hydrophobic derivatives probably occurred due to a hydrophobic interaction between the pigment and the pigment-coated cells. The electrophoretic mobility decreased gradually with an increasing pH and/or ionic strength with both addition and no addition of the pigment derivatives. The pattern of change of the pigment adsorption ratio under varying pH and/or ionic strength values was similar to the pattern for electrophoretic mobility.  相似文献   

9.
Li Liu  Jun-feng Song  Peng-fei Yu  Bin Cui 《Talanta》2007,71(5):1842-1848
A novel voltammetric method for the determination of β-d-glucose (GO) is proposed based on the reduction of Cu(II) ion in Cu(II)(NH3)42+–GO complex at lanthanum(III) hydroxide nanowires (LNWs) modified carbon paste electrode (LNWs/CPE). In 0.1 mol L−1 NH3·H2O–NH4Cl (pH 9.8) buffer containing 5.0 × 10−5 mol L−1 Cu(II) ion, the sensitive reduction peak of Cu(II)(NH3)42+–GO complex was observed at −0.17 V (versus, SCE), which was mainly ascribed to both the increase of efficient electrode surface and the selective coordination of La(III) in LNW to GO. The increment of peak current obtained by deducting the reduction peak current of the Cu(II) ion from that of the Cu(II)(NH3)42+–GO complex was rectilinear with GO concentration in the range of 8.0 × 10−7 to 2.0 × 10−5 mol L−1, with a detection limit of 3.5 × 10−7 mol L−1. A 500-fold of sucrose and amylam, 100-fold of ascorbic acid, 120-fold of uric acid as well as gluconic acid did not interfere with 1.0 × 10−5 mol L−1 GO determination.  相似文献   

10.
Wang Y  Yin X  Shi M  Li W  Zhang L  Kong J 《Talanta》2006,69(5):1240-1245
A novel electrochemical sensor with capability of probing chiral amino acids with gold nanoparticle (n-Au) labels using bovine serum albumin (BSA) as a chiral selector and subsequent signal amplification step by silver enhancement is introduced. The assay relies on the stereoselectivity of BSA embedded in ultrathin γ-alumina sol–gel film coated on the surface of the glassy carbon electrode (GCE). The recognition to the n-Au-labeled l- or d-amino acids for BSA-GCE could be monitored by the differential pulse voltammetry (DPV), while the DPV signal was greatly amplified by the anchored silver atoms on the n-Au, leading to a new way of quantitatively analysis of chiral amino acids electrochemically at sub-picomolar level. With l-tryptophan as the probe solute, the linear concentration range was from 1.33 × 10−12 to 1 × 10−9 mol L−1 and detection limit was 5 × 10−13 mol L−1. For tryptophan enantiomers, the enantioselectivity coefficient 2.3 was obtained.  相似文献   

11.
A lithium phthalocyanine radical and the analogous aluminum phthalocyanine radical were synthesized as part of an investigation of isostructural dopants. An improved synthesis of the free base of octa(pentoxy)phthalocyanine (H2Pc*) involves the reduction of 1,2-dicyano-4,5-dipentoxybenzene with hydroquinone. Deprotonation with lithium bis(trimethylsilyl)amide leads to the dilithium derivative Li2Pc* and subsequent oxidation with ferrocenium yields the radical LiPc*. Treatment of H2Pc* with Et2AlCl gives ClAlPc* and reduction with sodium amalgam yields AlPc*, the first reported aluminum phthalocyanine radical. In the solid state LiPc* and AlPc* are electrical conductors with pressed-pellet conductivities of 8 × 10−11 Ω−1 cm−1 and 5 × 10−7 Ω−1 cm−1, respectively.  相似文献   

12.
Electrochemical studies of famotidine were carried out using voltammetric techniques: cyclic voltammetry, linear sweep and square wave adsorptive stripping voltammetry. The dependence of the current on pH, buffer concentration, nature of the buffer, and scan rate was investigated. The best results for the determination of famotidine were obtained in MOPS buffer solution at pH 6.7. This electroanalytical procedure enabled to determine famotidine in the concentration range 1 × 10−9–4 × 10−8 mol L−1 by linear sweep adsorptive stripping voltammetry (LS AdSV) and 5 × 10−10–6 × 10−8 mol L−1 by square wave adsorptive stripping voltammetry (SW AdSV). Repeatability, precision and accuracy of the developed methods were checked. The detection and quantification limits were found to be 1.8 × 10−10 and 6.2 × 10−10 mol L−1 for LS AdSV and 4.9 × 10−11 and 1.6 × 10−10 mol L−1 for SW AdSV, respectively. The method was applied for the determination of famotidine in urine.  相似文献   

13.
Antigen I/II can be found on streptococcal cell surfaces and is involved in their interaction with salivary proteins. In this paper, we determine the adsorption enthalpies of salivary proteins to Streptococcus mutans LT11 and S. mutans IB03987 with and without antigen I/II, respectively, using isothermal titration calorimetry. In addition, protein adsorption to the cell surfaces was determined spectrophotometrically. S. mutans LT11 with antigen I/II, yielded a much higher, exothermic adsorption enthalpy at pH 6.8 (ranging from −2073 × 10−9 to −31707 × 10−9 μJ per bacterium) when mixed with saliva than did S. mutans IB03987 (−165 × 10−9 to −1107 × 10−9 μJ per bacterium) at all bacterial concentrations studied (5 × 109, 5 × 108, and 5 × 107 ml−1), largest effects per bacterium being observed for the lowest concentration. However, the enthalpy of salivary protein adsorption to S. mutans LT11 became smaller at pH 5.8. Adsorption isotherms for the S. mutans LT11 showed considerable protein adsorption at pH 6.8 (1.2–2.1 mg/m2), that decreased only slightly at pH 5.8 (1.1–1.6 mg/m2), with the largest amount adsorbed at the lowest bacterial concentration. This suggests that the protein(s) in the saliva with the strongest affinity for antigen I/II is (are) readily depleted from saliva. In conclusion, antigen I/II surface proteins on S. mutans play a determinant role in adsorption of salivary proteins through the creation of enthalpically favorable adsorption sites.  相似文献   

14.
The rate constants, k1 and k2 for the reactions of C2F5OC(O)H and n-C3F7OC(O)H with OH radicals were measured using an FT-IR technique at 253–328 K. k1 and k2 were determined as (9.24 ± 1.33) × 10−13 exp[−(1230 ± 40)/T] and (1.41 ± 0.26) × 10−12 exp[−(1260 ± 50)/T] cm3 molecule−1 s−1. The random errors reported are ±2 σ, and potential systematic errors of 10% could add to the k1 and k2. The atmospheric lifetimes of C2F5OC(O)H and n-C3F7OC(O)H with respect to reaction with OH radicals were estimated at 3.6 and 2.6 years, respectively.  相似文献   

15.
In this work, nickel hexacyanoferrate-modified electrode was developed to determine potassium ions in biodiesel by potentiometry. The modified electrodes exhibit a linear response to potassium ions in the concentration range of 4.0 × 10−5 to 1.0 × 10−2 mol L−1, with a detection limit of 1.9 × 10−5 mol L−1, and a near-Nernstian slope (53–55 mV per decade) at 25 °C. The method developed in this work was compared with flame photometry and the potassium concentration found in biodiesel showed that the modified electrode method gives results similar to those obtained by flame photometry.  相似文献   

16.
Amperometric enzyme biosensors for the determination of acetylcholine (ACh) and choline (Ch) have been described. For the fabrication of the biosensors, N-acetylaniline (nAN) was first electropolymerized on a Pt electrode surface to be served as a permselective layer to reject interferences. Bovine serum albumin (BSA) and choline oxidase (CHOD) were co-immobilized in a zinc oxide (ZnO) sol–gel membrane on the above modified Pt electrode for a Ch sensor, or CHOD, acetylcholinesterase (AChE) and BSA immobilized together for an ACh/Ch sensor. The poly (N-acetylaniline) (pnAN) film was the first time used for an ACh/Ch sensor and found to have excellent anti-interference ability, and the BSA in the sol–gel can improve the stability and activity of the enzymes. Amperometric detection of ACh and Ch were realized at an applied potential of +0.6 V versus SCE. The resulting sensors were characterized by fast response, expanded linear range and low interference from endogenous electroactive species. Temperature and pH dependence and stability of the sensor were investigated. The optimal ACh/Ch sensor gave a linear response range of 1.0 × 10−6 to 1.5 × 10−3 M to ACh with a detection limit (S/N = 3) of 6.0 × 10−7 M and a linear response range up to 1.6 × 10−3 M to Ch with a detection limit of 5.0 × 10−7 M. The biosensor demonstrated a 95% response within less than 10 s.  相似文献   

17.
Campuzano S  Pedrero M  Pingarrón JM 《Talanta》2005,66(5):1310-1319
The construction and performance under flow-injection conditions of an integrated amperometric biosensor for hydrogen peroxide is reported. The design of the bioelectrode is based on a mercaptopropionic acid (MPA) self-assembled monolayer (SAM) modified gold disk electrode on which horseradish peroxidase (HRP, 24.3 U) was immobilized by cross-linking with glutaraldehyde together with the mediator tetrathiafulvalene (TTF, 1 μmol), which was entrapped in the three-dimensional aggregate formed.

The amperometric biosensor allows the obtention of reproducible flow injection amperometric responses at an applied potential of 0.00 V in 0.05 mol L−1 phosphate buffer, pH 7.0 (flow rate: 1.40 mL min−1, injection volume: 150 μL), with a range of linearity for hydrogen peroxide within the 2.0 × 10−7–1.0 × 10−4 mol L−1 concentration range (slope: (2.33 ± 0.02) × 10−2 A mol−1 L, r = 0.999). A detection limit of 6.9 × 10−8 mol L−1 was obtained together with a R.S.D. (n = 50) of 2.7% for a hydrogen peroxide concentration level of 5.0 × 10−5 mol L−1. The immobilization method showed a good reproducibility with a R.S.D. of 5.3% for five different electrodes. Moreover, the useful lifetime of one single biosensor was estimated in 13 days.

The SAM-based biosensor was applied for the determination of hydrogen peroxide in rainwater and in a hair dye. The results obtained were validated by comparison with those obtained with a spectrophotometric reference method. In addition, the recovery of hydrogen peroxide in sterilised milk was tested.  相似文献   


18.
This paper presents a study about moderation and collimation of a neutron radiography system using 252Cf. A Monte Carlo Code, MCNP4B, has been used to obtain a maximum and more homogeneous thermal neutron flux in the collimator outlet next to the image plane. Among the various moderator materials investigated, high density polyethylene proved to be the most efficient, with a thermalization factor of 56 cm2. Using a collimator design assembly it was possible to obtain a normalized thermal neutron flux, at the image plane of 6×10−6 n cm−2 s−1 at an effective collimator ratio of 7.5, or 3.2×10−7 n cm−2 s−1 at an effective collimator ratio of 50.  相似文献   

19.
By designing a novel flow-through electrolytic cell (FEC), bromine was produced near to the surface of the platinum electrode by electrochemical oxidation of acidic KBr. The fast and weak chemiluminescence signal produced by the chemical reaction of the electrogenerated bromine with H2O2 was greatly enhanced by tetracyclines Based on these observations, a new, sensitive and simple electrogenerated chemiluminescence (ECL) method for the determination of tetracyclines was developed. Under the optimum experimental conditions, the calibration graphs are linear over the range 3.0×10−8 to 5.0×10−5 g ml−1 for tetracycline, 2.0×10−7 to 2.4×10−5 g ml−1 for oxytetracycline and 1.0×10−7 to 5.0×10−5 g ml−1 for chlortetracycline. The limits of detection (S/N=3) are 1.0×10−8 g ml−1 for tetracycline, 7.0×10−8 g ml−1 for oxytetracycline and 1.5×10−7 g ml−1 for chlortetracycline. For the determination 5.0×10−7 g ml−1 tetracycline, the relative standard deviation was <5%. The proposed method was used to determine tetracyclines in pharmaceutical formulations.  相似文献   

20.
Pertraction of dimethylcyclopropanecarboxylic acid (DMCCA) and phenol in a new hollow-fiber (HF) contactor of three liquid phases with distributed U-shaped bundles of microporous HF was studied. Trioctylamine (TOA), Hostarex A327 and Cyanex 471X have been used as carriers. The performance of this contactor is similar to other HF contactors. Its advantage is that both bundles of fibers can elongate without deformation of fibers and maldistribution of fibers in the bundles. Pulsation of the membrane phase increases the transport rate by 35–61% and it reaches a plateau value at the pulsation velocity of about 1.1 mm s−1. With increasing velocity of the feed in the fiber lumen the value of the overall mass-transfer coefficient increases, but soon a steady value is approached at the velocity of about 5.5 cm s−1. The diffusion resistances in a series model do not describe the pertraction of DMCCA well. The suggested new diffusion-reaction model, considering the resistance based on the kinetics of the stripping reaction, fits experimental data well. Not only the rate of the acid–carrier complex decomposition, but also that of the DMCCA dimer decomposition have to be considered. The estimated values of the apparent reaction rate constant were for the membrane with TOA 1.91×10−6 m s−1 and for pure n-alkanes 5.78×10−6 m s−1. The kinetic resistance on the stripping interface represents 20–60% of the overall mass-transfer resistance and its value is comparable to the diffusion resistance of the both walls.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号