首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 546 毫秒
1.
A cloud-point extraction (CPE) process using the nonionic surfactant Triton X-114 to simultaneous extraction and spectrophotometric determination of Zn(II), Co(II) and Ni(II) from aqueous solution using partial least squares (PLS) regression is investigated. The method is based on the color reaction of these cations with 1-(2-pyridylazo)2-naphthol and subsequent micelle-mediated extraction of products. The optimum extraction and reaction conditions such as pH, reagents concentration and effect of time have been studied. Linearity was obeyed in the range 2–150, 5–250 and 2–150 ng mL−1 of Zn(II), Co(II) and Ni(II) respectively. The relative standard error (RSE) for the simultaneous determination of 15 test samples of different concentrations of Zn(II), Co(II) and Ni(II) was 4.38%;, 1.18% and 2.42%, respectively. The total relative standard error (RSEt) for applying the PLS method to 15 synthetic samples in the linear ranges of these metals was 2.36%. The interference effect of some anions and cations was also tested. The method was applied to the simultaneous determination of Zn(II), Co(II) and Ni(II) in water and human urine samples.  相似文献   

2.
The possibility was investigated of using 2-mercaptobenzothiazole (MBT) for Ag(I) concentration by micellar extraction at cloud point (CP) temperature and subsequent determination by flame atomic absorption spectrometry (FAAS). The method is based on the complexation of Ag(I) with 2-mercaptobenzothiazole (MBT) in the presence of non-ionic micelles of Triton X-114. The effect of experimental conditions such as pH, concentration of chelating agent and surfactant, equilibration temperature and time on cloud point extraction was studied. Under the optimum conditions, the preconcentration of 10 mL of water sample in the presence of 0.1% Triton X-114 and 2 × 10−4 mol L−1 2-mercaptobenzothiazole permitted the detection of 2.2 ng mL−1 silver. The calibration graph was linear in the range of 10–200 ng mL−1, and the recovery of more than 99% was achieved. The proposed method was used in FAAS determination of Ag(I) in water samples.  相似文献   

3.
 A complexometric method for the determination of mercury in presence of other metal ions based on the selective masking ability of potassium bromide towards mercury is described. Mercury(II) present in a given sample solution is first complexed with a known excess of EDTA and the surplus EDTA is titrated against zinc sulfate solution at pH 5–6 using xylenol orange as the indicator. A known excess of 10% solution of potassium bromide is then added and the EDTA released from Hg-EDTA complex is titrated against standard zinc sulfate solution. Reproducible and accurate results are obtained for 8 mg to 250 mg of mercury(II) with a relative error ± 0.28% and standard deviations ≤0.5 mg. The interference of various ions is studied. This method was applied to the determination of mercury(II) in its alloys. Received April 18, 2001 Revision October 10, 2001  相似文献   

4.
4-Ethyl-1-(pyridin-2-yl)thiosemicarbazide (HEPTS) has been used as a new complexing agent in cloud point extraction (CPE) for preconcentration and determination of trace amounts of copper in saturated saline medium. The chemical variables affecting the separation and determination processes were optimized. Copper(II) is preconcentrated using 0.05% (w/v) Triton X-114 and 10−4 M HEPTS at pH 6. The surfactant rich phase containing the complex was dissolved in 2 mL MeOH and determined spectrophotometrically. The calibration curve is linear in the 0.1–25 ng/mL copper range. The proposed method was applied successfully in the determination of copper in water and saturated saline samples. The reaction between CuSO4 and HEPTS yields a deep-blue solid complex which is characterized by analytical and spectroscopic analyses.  相似文献   

5.
A sensitive and selective method has been developed for the determination of chromium in water samples based on using cloud point extraction (CPE) preconcentration and determination by flame atomic absorption spectrometry (FAAS). The method is based on the complexation of Cr(III) ions with Brilliant Cresyl Blue (BCB) in the presence of non-ionic surfactant Triton X-114. Under the optimum conditions, the preconcentration of 50 mL of water sample in the presence of 0.5 g/L Triton X-114 and 1.2 × 10−5 M BCB permitted the detection of 0.42 μg/L chromium(III). The calibration graph was linear in the range of 1.5–70 μg/L, and the recovery of more than 99% was achieved. The proposed method was used in FAAS determination of Cr(III) in water samples and certified water samples. In addition, the developed CPE-FAAS method was also used for speciation of the inorganic chromium species after reduction of Cr(VI) to Cr(III) using a thiosulphate solution of 120 mg/L in the presence of Hg(II) ion as a stabilizer.  相似文献   

6.
A simple and sensitive spectrophotometric method for determination of copper(II) is based on the formation of a blue coloured complex of Cu(II) with 9-phenyl-2,3,7-trihydroxy-6-fluorone (PF) in the presence of cetylpyridinium chloride (CP) and Triton X-100, has been developed. Optimum concentrations of PF, CP, Triton X-100 and pH ensuring maximum absorbance were defined. The complex Cu(II)-PF-CP-Triton X-100 shows maximum absorbance at 595 nm with a molar absorptivity value of 9.67x10(4) l mol(-1) cm(-1). The detection limit of the method is 0.028 mug ml(-1). Beer's law is obeyed for copper concentrations in the range 0.04-0.4 mug ml(-1). The studies of the effect of foreign ions on determination of copper, show that the selectivity of the method is poor. The cations of alkali metals and anions Br(-), Cl(-), I(-), F(-), NO(2)(-), NO(3)(-), CH(3)COO(-), SO(4)(2-), S(2)O(3)(2-), PO(4)(3-), citrates (examined in 1000-fold molar excess over copper) do not affect the determination. All cations forming complexes with PF have an interfering effect. The statistical evaluation of the method was carried out for six determinations using 10 mug of Cu and the following results were obtained: the standard deviation, SD=0.042, the confidence interval mu(95)=10.1+/-0.1 mug Cu. The method has been applied for determination of copper in blood serum.  相似文献   

7.
The application of the cloud point extraction (CPE) technique for capillary electrophoresis (CE) determination of metal ions was demonstrated using Cu(II) and Co(II) as model metal ions. The preconcentration of Cu(II) and Co(II) in aqueous solution was achieved by CPE with 1-(2-pyridylazo)-2-naphthol (PAN) as the chelating agent and Triton X-114 as the extractant. Baseline separation of the PAN chelates of Cu(II) and Co(II) was realized by CE with a photodiaode array detector in a  μm i.d. fused-silica capillary at 17 kV. A 50 mM NH4Ac buffer solution (pH 8.0) containing 0.2 mM of PAN in 80% (v/v) of acetonitrile and 20% (v/v) doubly deionized water (DDW) was used as the separation medium to avoid the adsorption of hydrophobic substances and nonionic surfactant Triton X-114 onto the inner surface of the separation capillary, ensuring the separation efficiency and reproducibility. The precision (relative standard deviation (R.S.D.), n=5) for five replicate injections of a mixture of 20 μg/l of Co(II) and Cu(II) were 0.74 and 1.8% for the migration time, 3.1 and 0.64% for the peak area measurement, respectively. The apparent concentration factor, which is defined as the concentration ratio of the analyte in the final diluted surfactant-rich extract ready for CE separation and in the initial solution, was 15.9 for Co(II) and 16.3 for Cu(II). The linear concentration range was from 3 to 100 μg/l for both Co(II) and Cu(II). The detection limits of Co(II) and Cu(II) were 0.12 and 0.26 μg/l, respectively. The developed method was successfully applied to the determination of Co(II) and Cu(II) in tap water, snow water, and flavor wines.  相似文献   

8.
 Sorption of copper on filter-paper with chemically attached hexamethylenediamino-groups (HMDA-filter) allows to obtain the sorbent (Cu/HMDA-filter) stable in respect to desorption of copper. A nitrogen-containing herbicide imazapyr (imaz) is retained on Cu/HMDA-filters at pH 5.5–7.0 forming a relatively stable complex. Imazapyr is determined directly on the sorbent by its activating effect in the oxidation of hydroquinone with H2O2 catalyzed by Cu(II) with the formation of a product absorbing at 490 nm. The copper ions serve both to preconcentrate imazapyr and to catalyze the indicator reaction. The use of 1-μL sample aliquots pipetted onto the Cu/HMDA-filters allows to determine 1 × 10−3–0.03 μmol of imazapyr, whereas preconcentration of the analyte by pumping of its solution through the same sorbent expands the linear range to 1 × 10−4–1 × 10−1 μmol of imazapyr. When the indicator reaction is carried out in solution, the range of activating action of imazapyr is narrower (0.06–0.1 μmol a for a solution volume of 10 mL). The determination is selective: 5–100-fold amounts of amines, aminoacids, carboxylic acid derivatives and other model compounds do not interfere. Soil extracts and carrot juice samples spiked with imazapyr have been analyzed. Received January 10, 2000. Revision July 28, 2000.  相似文献   

9.
An anodic stripping voltammetric procedure for the determination of Cu(II) at an in situ-plated stannum film electrode (SnFE) was described. The results indicated that the SnFE had an attractive electroanalytical performance, with two distinct voltammetric stripping signals for copper and stannum, and showed the superior advantage for the determination of copper compared with the bismuth film electrode. Several experimental parameters were optimized. The SnFE exhibited highly linear behavior in the concentration range from 1.0 to 100.0 μg L−1 of Cu(II) (r = 0.994) with the detection limit of 0.61 μg L−1 (S/N = 3), and the relative standard deviation for a solution containing 40.0 μg L−1 Cu(II) was 2.2% (n = 8). The procedure has been successfully applied for the determination of Cu(II) in lake water sample.  相似文献   

10.
 A fluorescence quenching method for the determination of vanadium (V) based on the vanadium- catalyzed oxidation of rhodamine 6G (R6G) with periodate in the presence of ethylenediaminetetraacetic acid disodium salt (EDTA) in sulfuric acid medium is described. The fluorescence was measured with excitation and emission wavelengths of 525 and 555 nm, respectively. The calibration graph for vanadium (V) had linear ranges of 3.0 × 10−9–1.5 × 10−8 mol/l and 1.5 × 10−8–4.0 × 10−8 mol/l, respectively. The detection limit was 1.7 × 10−9 mol/l. The proposed method was successfully applied to the determination of vanadium (V) in river water, rain water and cast iron samples. Received June 29, 2001 Revision October 9, 2001  相似文献   

11.
 A simple and direct spectrophotometric method has been developed for the determination of cobalt(II) using N,N′-Bis(2-aminobenzoyl)ethylenediamine (Baben). The method is based on the colour reaction between Baben and cobalt(II) in borax buffer (pH 9.2). The studies are carried out at 470 nm at which the calculated value of molar absorptivity is found to be 1.102 × 104 L mol−1 cm−1. The system obeys Beer’s law over a wide range of concentration (2–20 μg/ml). The effect of interfering ions has been studied and the method was applied to the determination of cobalt in water, industrial effluents and in alloys and the results were highly satisfactory. Received May 8, 2000. Revision January 30, 2001.  相似文献   

12.
The electrochemical behaviour of a Cu/CuSe electrode was studied in order to define its selectivity towards cupric ions, Nerstian response, limit of detection and response time. The chalcogenide electrode was prepared by cathodic deposition of Se and subsequent formation of a thin layer of CuSe on a copper substrate. A Cu/CuSe microelectrode was prepared using copper wire 75 μm in diameter. The dimensions and response time (<0.5 s) allowed use of this electrode in the “vibrating probe method” with the aim of measuring net influxes as well as effluxes of copper(II) ions in Olea europaea roots. The electrode potential was measured along the root at a distance of 5 μm from the surface for 5 s, and then again for 5 s at a distance of 55 μm, moving the microelectrode with respect to the root surface by steps with a frequency of 0.1 Hz. The potentials measured at the two extremes of vibration were then converted to copper(II) concentrations. Substitution of these values in Fick's law yields the flux, assuming the diffusion constant D for copper ions in aqueous solutions. The results enabled us to detect copper(II) fluxes as small as 0.05 pmol cm−2 s−1. Copper(II) influx showed marked spatial and temporal features: it was highest at about 1.5 mm from the root apex and exhibited an oscillatory pattern in time. Received: 29 September 1999 / Accepted: 11 January 2000  相似文献   

13.
A sensitive and simple method for flame atomic absorption spectrometry (FAAS) determination of antimony species after separation/preconcentration by cloud point extraction (CPE) has been developed. When the system temperature is higher than the cloud point extraction temperature, the complex of antimony (III) with N-benzoyl-N-phenyhydroxylamine (BPHA) can enter the surfactant-rich phase, whereas the antimony (V) remains in the aqueous phase. Antimony (III) in surfactant-rich phase was analyzed by FAAS and antimony (V) was calculated by subtracting of antimony (III) from the total antimony after reducing antimony (V) to antimony (III) by L-cysteine. The main factors affecting the cloud point extraction, such as pH, concentration of BPHA and Triton X-114, equilibration temperature and time, were investigated systematically. Under optimized conditions, the detection limits (3σ) were 1.82 ng mL−1 for Sb(III) and 2.08 ng mL−1 for Sb(total), and the relative standard deviations (RSDs) were 2.6% for Sb(III) and 2.2% for Sb(total). The proposed method was applied to the speciation of antimony species in artificial seawater and wastewater, and recoveries in the range of 95.3–106% were obtained by spiking real samples. This technique was validated by means of reference water materials and gave good agreement with certified values.  相似文献   

14.
A device has been developed for the measurement of copper(II) ions (Cu2+) in aqueous medium. The device reported here is an electrochemical transistor which consists of two platinum electrodes separated by 100 μm spacing and bridged with an anodically grown film of polycarbazole. Polycarbazole film (undoped form) is observed to be highly selective for the Cu(II) ions. In a completed device, the conductivity of the polycarbazole film changes on addition of Cu(II) ions. The change in conductivity is attributed to the conformational changes in the polymer phase on occupation of the Cu(II) ions, without affecting electron/proton transfer. The device turns on by adding 2.5 × 10−6 M Cu(II) ions and reaches a saturation region beyond 10−4 M Cu(II) ion concentrations. In the above concentration range, the device response [I D vs. log Cu(II) ion concentration] is linear. The selectivity of the device for other metal ions such as Cu(I), Ni(II), Co(II), Fe(II), Fe(III), Zn(II) and Pb(II) is also studied. Received: 6 April 1999 / Accepted: 20 August 1999  相似文献   

15.
 The construction and electrochemical response characteristics of poly(vinyl) chloride matrix membrane sensors for menadione (vitamin K3) are described. Membranes incorporating the ion association complexes of menadione anion with bathophenanthroline nickel(II) and iron(II) as electroactive materials show linear response for menadione over the range 10−1–10−5M with anionic slopes of 58.2–51.4 mV per concentration decade. Both sensors exhibit fast response time (20–30 s), low detection limit (2 × 10−5M), good stability (4–6 weeks) and selectivity coefficient (10−1–10−3). Direct potentiometric determination of menadione under static and hydrodynamic mode of operations shows average accuracies of 98.8 and 98.5% with relative standard deviations of 0.6% and 1.3%, respectively. Application of the method for the determination of menadione in human plasma gives favourable results compared with those obtained by the standard spectrophotometric method. Received February 26, 2001. Revision October 1, 2001.  相似文献   

16.
In this article, a sensitive cloud point extraction procedure for the preconcentration of trace amounts of palladium, gold and nickel prior to their determination by flame atomic absorption spectrometry has been developed. The cloud point extraction method is based on the complexation of Pd(II), Au(II), and Ni(II) ions with 1-(2-pyridylazo)-2-naphthol and entrapping in non-ionic surfactant Triton X-114. The main factors affecting cloud point extraction efficiency, such as pH of sample solution, concentration of 1-(2-pyridylazo)-2-naphthol and Triton X-114, equilibration temperature and time, were investigated in detail. Under the optimized conditions, calibration curves were constructed for the determination of palladium, gold and nickel according to the general procedure. Linearity was maintained from 0.01 to 1.0 μg/mL for palladium, 10.0 μg/mL to 1.5 μg/mL for gold, and 10.0 μg/mL to 0.5 μg/mL for nickel. Detection limits based on three times the standard deviation of the blank divided by the slope of analytical curve (3Sb/m) for Pd(II), Au(III), and Ni(11) ions were 3.4, 3.9, and 2.4 μg/mL, respectively. Seven replicate determination of a mixture of 0.5 μg/mL palladium and gold and 0.2 μg/mL nickel gave a mean absorbance of 0.174, 0.150, and 0.201 with relative standard deviation ±1.5, ±1.3, and ±1.8%, respectively. The high efficiency of cloud point extraction to carry out the determination of analytes in complex matrices was demonstrated. The proposed method has been applied for determination of trace amount of palladium, gold and nickel in certified reference material and water samples with satisfactory results.  相似文献   

17.
A cloud-point extraction (CPE) method using Triton X-114 non-ionic surfactant was developed for the extraction and preconcentration of carbamate insecticide residues (i.e., methomyl, propoxur, carbofuran, carbaryl, isoprocarb, and promecarb) in fruit samples. The optimum conditions of CPE were 1.5% (w/v) Triton X-114, 7.0% (w/v) NaCl and 20 min equilibrated at 45 °C. The surfactant-rich phase was then analyzed by reversed-phase high-performance liquid chromatography with ultraviolet detection at 270 nm, under gradient separation using methanol and 0.1% (v/v) acetic acid. Under the study conditions, six carbamate insecticides were successfully separated within 27 min. Good reproducibility was obtained with the relative standard deviation of <3% for retention time and <9% for peak area. Limits of detection in the studied fruit samples were in the range of 0.1–1.0 mg kg−1. No carbamate insecticides were detected in the studied fruit samples. The high recoveries of the spiked fruit samples were obtained in the range 80.0–107%. The CPE method has been shown to be a potential useful methodology for the preconcentration of the target analytes, with a preconcentration factor of 14. Moreover, the method is simple, has high sensitivity, consumes much less solvent than traditional methods, and is environmental friendly.  相似文献   

18.
Four new complexes of 2,3,4-trimethoxybenzoic acid anion with manganese(II), cobalt(II), nickel(II) and copper(II) cations were synthesized, analysed and characterized by standard chemical and physical methods. 2,3,4-Trimethoxybenzoates of Mn(II), Co(II), Ni(II) and Cu(II) are polycrystalline compounds with colours typical for M(II) ions. The carboxylate group in the anhydrous complexes of Mn(II), Co(II) and Ni(II) is monodentate and in that of Cu(II) monohydrate is bidentate bridging one. The anhydrous complexes of Mn(II), Co(II) and Ni(II) heated in air to 1273 K are stable up to 505–517 K. Next in the range of 505–1205 K they decompose to the following oxides: Mn3O4, CoO, NiO. The complex of Cu(II) is stable up to 390 K, and next in the range of 390–443 K it loses one molecule of water. The final product of its decomposition is CuO. The solubility in water at 293 K is of the order of 10–3 mol dm–3 for the Mn(II) complex and 10–4 mol dm–3 for Co(II), Ni(II) and Cu(II) complexes. The magnetic moment values of Mn2+, Co2+, Ni2+ and Cu2+ ions in 2,3,4-trimethoxybenzoates experimentally determined in the range of 77–300 K change from 5.64–6.57 μB (for Mn2+), 4.73–5.17 μB (for Co2+), 3.26–3.35 μB (for Ni2+) and 0.27–1.42 μB (for Cu2+). 2,3,4-Trimethoxybenzoates of Mn(II), Co(II) and Ni(II) follow the Curie–Weiss law, whereas that of Cu(II) forms a dimer.  相似文献   

19.
Molecular wires containing copper(II) (CuMW), in the form of the coordination polymer (Cu(II)4(bpp)4(maa)8(H2O)2).2H2O (bpp=1,3-bis(4-pyridyl)propane, maa=2-methylacrylic acid), and multiwalled carbon nanotubes (CNT) have been combined to prepare a paste electrode (CuMW/CNT/PE). The voltammetric response of the CuMW/CNT/PE to metformin (MET) was significantly greater than that of electrodes prepared from other materials, because of both the surface effect of CuMW and CNT and coordination of MET with the Cu(II) ion in the CuMW. A novel voltammetric method for determination of MET is proposed. In pH 7.2 Britton–Robinson buffer, using single sweep voltammetry, the second-order derivative peak current for oxidation of MET at 0.97 V (relative to SCE) increased linearly with MET concentration in the range 9.0 × 10−7–5.0 × 10−5 mol L−1 and the detection limit was 6.5 × 10−7 mol L−1. Figure When a combination of molecular wires containing copper(II) (CuMW) and multiwalled carbon nanotubes (CNT) was used to prepare a paste electrode (CuMW/CNT/PE) the voltammetric response to metformin (curve c) was significantly higher than that at a carbon/PE (curve a) or a CNT/PE (curve b), because of the amplification effect of CNT and CuMW. A novel voltammetric method is proposed for determination of MET  相似文献   

20.
 A novel sensitive and simple method for rapid and selective extraction, preconcentration and determination of iron (as its bathophenanthroline complex) and copper (as its neocuproine complex) using octadecyl silica cartridges and dual wavelength spectrophotometry is presented. The dual wavelength method (533 nm for the iron-bathophenanthroline and 454 nm for the copper-neocuproine as the analytical wavelength) is used to eliminate spectral interferences. Extraction efficiency and the influence of flow rates of sample solution and eluent, pH, amount of neocuproine, bathophenanthroline and hydroxylamine hydrochloride, type and least amount of eluent for elution of iron and copper complexes from cartridge, break-through volume and limit of detection are evaluated. The effects of various cationic and anionic interferences on percent recovery of iron and copper are also studied. Extraction efficiencies >95% are obtained by elution of cartridges with minimal amount of organic solvent. Iron and copper were determined in the range of 3–100 ng mL−1. The limits of detection are 0.98 and 1.13 ng mL−1 for iron and copper, respectively. The proposed method is applied successfully to the determination of both analytes in river, tap and well water samples. Author for correspondence. E-mail: yyamini@modares.ac.ir Received September 18, 2002; accepted December 12, 2002 Published online May 5, 2003  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号