首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A liquid chromatography tandem mass spectrometry method for buprenorphine (BUP), norbuprenorphine (NBUP), methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), cocaine, benzoylecgonine, ecgonine methyl ester (EME), morphine, codeine, 6-acetylmorphine, heroin, 6-acetylcodeine, cotinine, and trans-3′-hydroxycotinine quantification in sweat was developed and comprehensively validated. Sweat patches were mixed with 6 mL acetate buffer at pH 4.5, and supernatant extracted with Strata-XC-cartridges. Reverse-phase separation was achieved with a gradient mobile phase of 0.1% formic acid and acetonitrile in 15 min. Quantification was achieved by multiple reaction monitoring of two transitions per compound. The assay was a linear 1–1,000 ng/patch, except EME 5–1,000 ng/patch. Intra-, inter-day and total imprecision were <10.1%CV, analytical recovery 87.2–107.7%, extraction efficiency 35.3–160.9%, and process efficiency 25.5–91.7%. Ion suppression was detected for EME (−63.3%) and EDDP (−60.4%), and enhancement for NBUP (42.6%). Deuterated internal standards compensated for these effects. No carryover was detected, and all analytes were stable for 24 h at 22 °C, 72 h at 4 °C, and after three freeze/thaw cycles. The method was applied to weekly sweat patches from an opioid-dependent BUP-maintained pregnant woman; 75.0% of sweat patches were positive for BUP, 93.8% for cocaine, 37.5% for opiates, 6.3% for methadone and all for tobacco biomarkers. This method permits a fast and simultaneous quantification of 14 drugs and metabolites in sweat patches, with good selectivity and sensitivity.  相似文献   

2.
A validated method for simultaneous LCMSMS quantification of nicotine, cocaine, 6-acetylmorphine (6AM), codeine, and metabolites in 100 mg fetal human brain was developed and validated. After homogenization and solid-phase extraction, analytes were resolved on a Hydro-RP analytical column with gradient elution. Empirically determined linearity was from 5–5,000 pg/mg for cocaine and benzoylecgonine (BE), 25–5,000 pg/mg for cotinine, ecgonine methyl ester (EME) and 6AM, 50-5000 pg/mg for trans-3-hydroxycotinine (OH-cotinine) and codeine, and 250–5,000 pg/mg for nicotine. Potential endogenous and exogenous interferences were resolved. Intra- and inter-assay analytical recoveries were ≥92%, intra- and inter-day and total assay imprecision were ≤14% RSD and extraction efficiencies were ≥67.2% with ≤83% matrix effect. Method applicability was demonstrated with a postmortem fetal brain containing 40 pg/mg cotinine, 65 pg/mg OH-cotinine, 13 pg/mg cocaine, 34 pg/mg EME, and 525 pg/mg BE. This validated method is useful for determination of nicotine, opioid, and cocaine biomarkers in brain.  相似文献   

3.
High-throughput chiral liquid chromatography/tandem mass spectrometry   总被引:3,自引:0,他引:3  
Chiral liquid chromatography is a well-established area of bioanalytical chemistry and is often used during the processes of drug discovery and development. The development and use of a chiral drug require the understanding of the pharmacokinetic characteristics of each of the enantiomers, including potential differences in their absorption, distribution, metabolism, and excretion. Chromatographic techniques coupled to atmospheric pressure ionization-tandem mass spectrometry have shown potential as sensitive and robust tools in the quantitative and qualitative determination of enantiomers in biologic fluids and tissue extracts. However, development of a chiral liquid chromatography method requires time-consuming procedures that are devised empirically. Clearly, there is an incentive to design chromatographic approaches that are easy to use, compatible with mass spectrometry ionization interface conditions, exhibit relatively short run times without compromising sensitivity, and offer a broad analyte specificity. For these reasons, the present paper explores the feasibility of the bonded macrocyclic glycopeptide phases (teicoplanin and vancomycin) for analysis by chiral liquid chromatography/tandem mass spectrometry. Ritalinic acid, pindolol, fluoxetine, oxazepam, propranolol, terbutaline, metoprolol, and nicardipine were tested in this study. Furthermore, an example of a simultaneous chiral LC/MS/MS detection (chromatographic run time approximately 10 min) of four pharmaceutical products resulting in baseline resolutions of all four pairs of enantiomers is presented. Methanol, an MS-compatible mobile phase, was utilized in all the experiments.  相似文献   

4.
A sensitive and specific liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the simultaneous quantification of opioids, cocaine, and metabolites in urine was developed and validated. A 10-microL aliquot of urine was injected directly onto the LC/MS/MS system. The lack of sample preparation substantially reduced total analysis time. Separation was performed by reversed-phase chromatography with gradient elution for all analytes in 26 min. Atmospheric pressure chemical ionization (APCI) was a rugged and efficient ionization technique for basic drugs. Identification and quantification was based on selected reaction monitoring (SRM). Calibration, with deuterated internal standards, was performed by linear regression analysis (weighting factor 1/x). Limits of quantitation (LOQ) were established between 10-100 ng/mL and linearity was obtained up to a maximum of 10 000 ng/mL with an average correlation coefficient (R(2)) > 0.99. Analytical validation criteria for specificity, precision, accuracy, dilution integrity, matrix effect, and stability were fulfilled. The method proved to be simple and time efficient, and was applicable for illicit drug use monitoring and methadone treatment compliance in clinical research projects at the National Institute on Drug Abuse (NIDA).  相似文献   

5.
A fast and highly sensitive electrospray ionization tandem mass spectrometry (ESI-MS/MS) method has been developed for the simultaneous determination of morphine, 6-methylacetylmorphine (6-MAM), codeine, cocaine and benzoylecgonine (BZE) in hair from drug abusers. Pulverized hair samples were subjected to an optimized matrix solid phase dispersion (MSPD) procedure with alumina, followed by diluted hydrochloric acid elution on column solid-phase extraction (SPE) clean-up/pre-concentration. Alternatively, samples were also subjected to an optimized ultrasound assisted enzymatic hydrolysis (USEH) with Pronase E, followed by an off-line SPE clean up/pre-concentration procedure. Positive electrospray ionization and multiple reaction monitoring (MRM) with one precursor ion/product ion transition were used for the identification and quantification (deuterated analogues of each target as internal standards) of each analyte. The chromatographic pump and the autosampler were used for injecting the standards and the hair extracts (20 μL) as a flow injection analysis mode. The highest sensitivity was achieved when delivering the targets with an acetonitrile/water/formic acid (80/19.875/0.125) mixture. The limits of detection of the method were 39.2, 4.4, 6.8, 7.0 and 7.4 ng g(-1) for morphine, 6-MAM, codeine, cocaine and BZE, respectively. Relative standard deviations of intra- and inter-day precision were lower than 9 and 12%, respectively; whereas, analytical recoveries ranged from 96±5 to 106±4%. The developed method (MSPD-ESI-MS/MS) was applied to different hair samples from polydrug abusers, and results were statistically compared to those obtained after a conventional gas chromatography-mass spectrometry (GC-MS) analysis and also after USEH and ESI-MS/MS or GC-MS determinations.  相似文献   

6.
7.
A high-performance liquid chromatographic method with triple-quadrupole mass spectrometry detection (LC-MS-MS) was developed and validated for the first time for the simultaneous quantification of zopiclone and its metabolites in rat plasma samples. The analytes were isolated from rat plasma by liquid–liquid extraction and separated using a chiral stationary phase based on an amylose derivative, Chiralpak ADR-H column, and ethanol–methanol–acetonitrile (50:45:5, v/v/v) plus 0.025% diethylamine as the mobile phase, at a flow-rate of 1.0 mL min−1. Moclobemide was used as the internal standard. The developed method was linear over the concentration range of 7.5–500 ng mL−1. The mean absolute recoveries were 74.6 and 75.7; 61.6 and 56.9; 72.5, and 70.7 for zopiclone enantiomers, for N-desmethyl zopiclone enantiomers and for zopiclone-N-oxide enantiomers, respectively, and 75.9 for the internal standard. Precision and accuracy were within acceptable levels of confidence (<15%). The method application in a pilot study of zopiclone kinetic disposition in rats showed that the levels of (+)-(S)-zopiclone were always higher than those of (−)-R-zopiclone. Higher concentrations were also observed for (+)-(S)-N-desmethyl zopiclone and (+)-(S)-N-oxide zopiclone, confirming the stereoselective disposition of zopiclone.  相似文献   

8.
Ye S  Yao Z  Na G  Wang J  Ma D 《Journal of separation science》2007,30(15):2360-2369
This paper describes a rapid method for the determination of 14 kinds of sulfonamides (SAs) in wastewater using SPE, and LC-MS/MS with positive ESI (ESI(+)) and selected reaction monitoring (SRM) mode. The SPE was performed on an Oasis hydrophilic-lipophilic-balanced (HLB) cartridge. Chromatographic separation on a C18 column was achieved using a binary eluent containing methanol and water with 0.2% formic acid. Typical recoveries of the analytes ranged from 22.3 to 87.0% at a fortification level of 100 ng/L. The LODs in wastewater except sulfathiazole (3 ng/L) could be detected and quantified at levels as low as 1 ng/L. Finally, the method was applied to water from the municipal outlet and the aquaculture wastewater effluent. Sulfamethazine (SM(2)), sulfamethoxypyridazine (SMP), and sulfamethoxazole (SMZ) were most frequently found in wastewater in a concentration range between 1.2 and 31.7 ng/L.  相似文献   

9.
The metabolism of the anti-inflammatory drug Celecoxib in rabbits was characterized using liquid chromatography (LC)/tandem mass spectrometry (MS/MS) with precursor ion and constant neutral loss scans followed by product ion scans. After separation by on-line liquid chromatography, the crude urine samples and plasma and fecal extracts were analyzed with turbo-ionspray ionization in negative ion mode using a precursor ion scan of m/z 69 (CF(3)) and a neutral loss scan of 176 (dehydroglucuronic acid). The subsequent product ion scans of the [M - H] ions of these metabolites yielded the identification of three phase I and four phase II metabolites. The phase I metabolites had hydroxylations at the methyl group or on the phenyl ring of Celecoxib, and the subsequent oxidation product of the hydroxymethyl metabolite formed the carboxylic acid metabolite. The phase II metabolites included four positional isomers of acyl glucuronide conjugates of the carboxylic acid metabolite. These positional isomers were caused by the alkaline pH of the rabbit urine and were not found in rabbit plasma. The chemical structures of the metabolites were characterized by interpretation of their product ion spectra and comparison of their LC retention times and the product ion spectra with those of the authentic synthesized standards.  相似文献   

10.
Midazolam (MDZ), a short-acting benzodiazepine, is a widely accepted probe drug for CYP3A phenotyping. Published methods for its analysis have used either therapeutic doses of MDZ, or, if employing lower doses, were mostly unable to quantify the two hydroxy metabolites. In the present study, a sensitive and specific liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the quantitative determination of MDZ and two of its metabolites (1'-hydroxymidazolam (1'-OHMDZ) and 4-hydroxymidazolam (4-OHMDZ)) in human plasma and oral fluid. After liquid-liquid extraction with hexane/dichloromethane (73:27, v/v), the analytes were separated on a Luna C18(2) (100 x 2.1 mm) analytical column using gradient elution. Detection was achieved using tandem mass spectrometry on an ion trap mass spectrometer. Midazolam-d6 was used as internal standard for quantification. The calibration curves were linear (R2 >0.998) between 0.05 and 20 ng/mL for MDZ and both metabolites in both matrices. Using 1 mL samples, the limit of detection was 0.025 ng/mL and the limit of quantification was 0.05 ng/mL for MDZ and the hydroxy metabolites in both matrices. Intra- and inter-day accuracies, determined at three different concentrations, were between 92.1 and 102.3% and the corresponding coefficients of variation were <7.3%. The average recoveries were 90.6%, 86.7% and 79.0% for MDZ, 1'-OHMDZ and 4-OHMDZ in plasma and 95.3%, 96.6% and 86.8% for MDZ, 1'-OHMDZ and 4-OHMDZ, respectively, in oral fluid. The method was successfully applied to a pharmacokinetic study, showing that MDZ and its hydroxy metabolites can be determined precisely in in vivo samples obtained following a single oral or intravenous dose of 2 mg MDZ. The method appears to be useful for CYP3A phenotyping in plasma using sub-therapeutic MDZ doses, but larger studies are needed to test this assumption.  相似文献   

11.
A rapid and sensitive LC–MS/MS method was developed and validated for the simultaneous determination of buprenorphine and its three metabolites (buprenorphine glucuronide, norbuprenorphine and norbuprenorphine glucuronide) as well as naloxone and its metabolite naloxone glucuronide in the rat plasma. A hydrophilic interaction chromatography column and a mobile phase containing acetonitrile and ammonium formate buffer (pH 3.5) were used for the chromatographic separation. Mass spectrometric detection was achieved by an electrospray ionization source in the positive mode coupled to a triple quadrupole mass analyzer. The calibration curves for the six analytes displayed good linearity over the concentration range 1.0 or 5.0–1000 ng/mL. The intra and inter‐day precision (CV) ranged from 2.68 to 16.4% and from 9.02 to 14.5%, respectively. The intra‐ and inter‐day accuracy (bias) ranged from −14.2 to 15.2% and from −9.00 to 4.80%, respectively. The extraction recoveries for all the analytes ranged from 55 to 86.9%. The LC–MS/MS method was successfully applied to a pharmacokinetic study of buprenorphine–naloxone combination in rats.  相似文献   

12.
Gu Q  Shi X  Yin P  Gao P  Lu X  Xu G 《Analytica chimica acta》2008,609(2):192-200
Two simple, rapid and specific analytical methods for 13 catecholamines and their metabolites have been developed based on liquid chromatography tandem mass spectrometry in a multiple reaction monitoring mode. Tyrosine, dopamine, dihydroxyphenylalanine, epinephrine, norepinephrine, 3-methoxytyramine, normetanephrine, metanephrine and isoproterenol (internal standard) were separated on a Kromasil™ Cyano analytical column by a mobile phase consisting of 60% (v/v) acetonitrile and 40% (v/v) water adjusted with formic acid to pH 3.0, and detected by positive ionization electrospray tandem mass spectrometry. While vanillymandelic acid, 3,4-dihydroxymandelic acid, homovanillic acid, 3,4-dihydroxyphenylacetic acid, 4-hydroxy-3-methoxyphenylglycol and 5-hydroxy-2-indolecarboxylic acid (internal standard) were separated on a reversed-phase Shim-Pak VP-ODS column with the mobile phase of 60% (v/v) acetonitrile, and 40% (v/v) water adjusted with formic acid to pH 4.5 and detected in the negative ionization electrospray tandem mass spectrometry. The influence of various parameters such as column type and mobile phase composition on separation and sensitivity were investigated. The limits of detection were in the range of 0.5-20 ng mL−1. The mean recoveries determined from three different concentrations of each analyte were above 85.4%. The precision of the method calculated as relative standard deviation was lower than 5.3%. Deduced from the results of real sample analysis, adrenal gland synthesizes and stores the catecholamine hormones norepinephrine and epinephrine.  相似文献   

13.
14.
15.
In this study, the simultaneous extraction of estrone (E1), 17β-estradiol (E2), estriol (E3), ethinylestradiol (EE2), and their glucuronated and sulfated metabolites in milk was optimized using solid-phase extraction (SPE). The aim of this research was to analyze estrogens and their conjugated metabolites by liquid chromatography with tandem mass spectrometry (LC–MS/MS) in a single run, without the need to perform enzymatic cleavage and derivatization. Two SPE cartridges in tandem were used, consisting of sorbents based on the hydrophilic–lipophilic balance and amine-functionalized packing materials. To monitor analyte loss at every step of the SPE procedure 14C-labeled E2 was spiked into the milk sample and the radioactivity was monitored at all stages of the SPE. In addition, non-radiolabeled standards of estrogens and metabolites were used to optimize solvent systems for the SPE and LC–MS/MS. The optimized method described in this paper can achieve recoveries ranging from 72% to 117% for the free estrogens (E1, E2, E3, and EE2), and 62% to 112% for seven conjugated metabolites. The three doubly conjugated, highly polar metabolites included in this study gave lower recoveries (≤43%) due to poor retention in SPE. Finally, commercial milk samples were analyzed for the presence of estrogens and their conjugated metabolites. Estrone (concentration range: 23–67 ng/L) was found to be the major free estrogen present in all milk samples. Estradiol was consistently observed in milk, but the concentrations were below the limit of detection (LOD of 10 ng/L), and no estriol and ethinylestradiol were detected. Several conjugated estrogen metabolites were identified, 17β-estradiol-3-glucuronide (71–289 ng/L), estrone-3-sulfate (60–240 ng/L), 17β-estradiol-3,17β-sulfate (<LOD to 30 ng/L), and estrone-3-glucuronide (<LOQ of 25 ng/L). This method proved efficient in the simultaneous analysis of estrogens and their metabolites in milk.  相似文献   

16.
A micro-analytical method based on spotting urine samples (20 μL) onto blood/urine spot collection cards followed by air-drying and extraction (dried urine spot, DUS) was developed and validated for the screening/confirmation assay of morphine, 6-methylacetylmorphine (6-MAM), codeine, cocaine and benzoylecgonine (BZE). Acetonitrile (3 mL) was found to be a useful solvent for target extraction from DUSs under an orbital-horizontal stirring at 180 rpm for 10 min. Determinations were performed by direct electrospray ionization tandem mass spectrometry (ESI-MS/MS) under positive electrospray ionization conditions, and by using multiple reaction monitoring (MRM) with one precursor ion/product ion transition for the identification and quantification (deuterated analogs of each target as internal standards) of each analyte. The limits of detection of the method were 0.26, 0.94, 1.5, 1.1, and 2.0 ng mL−1, for cocaine, BZE, codeine, morphine and 6-MAM, respectively; whereas, relative standard deviations of intra- and inter-day precision were lower than 8 and 11%, respectively, and intra- and inter-day analytical recoveries ranged from 94 ± 4 to 105 ± 3%. The small volume of urine required (20 μL), combined with the simplicity of the analytical technique makes it a useful procedure for screening/quantifying drugs of abuse. The method was successfully applied to the analysis of urine from polydrug abusers.  相似文献   

17.
A quantitative Ultra Performance liquid chromatography/tandem mass spectrometry (UPL/MS/MS) protocol was developed for a five-compound mixture in rat plasma. A similar high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) quantification protocol was developed for comparison purposes. Among the five test compounds, three preferred positive electrospray ionization (ESI) and two preferred negative ESI. As a result, both UPLC/MS/MS and HPLC/MS/MS analyses were performed by having the mass spectrometer collecting ESI multiple reaction monitoring (MRM) data in both positive and negative ion modes during a single injection. Peak widths for most standards were 4.8 s for the HPLC analysis and 2.4 s for the UPLC analysis. There were 17 to 20 data points obtained for each of the LC peaks. Compared with the HPLC/MS/MS method, the UPLC/MS/MS method offered 3-fold decrease in retention time, up to 10-fold increase in detected peak height, with 2-fold decrease in peak width. Limits of quantification (LOQs) for both HPLC and UPLC methods were evaluated. For UPLC/MS/MS analysis, a linear range up to four orders of magnitude was obtained with r2 values ranging from 0.991 to 0.998. The LOQs for the five analytes ranged from 0.08 to 9.85 ng/mL. Three levels of quality control (QC) samples were analyzed. For the UPLC/MS/MS protocol, the percent relative standard deviation (RSD%) for low QC (2 ng/mL) ranged from 3.42 to 8.67% (N = 18). The carryover of the UPLC/MS/MS protocol was negligible and the robustness of the UPLC/MS/MS system was evaluated with up to 963 QC injections.  相似文献   

18.
This paper describes the development of a high performance liquid chromatography/tandem mass spectrometric (MS/MS) procedure for the specific qualitative and quantitative analysis of lipid aldehydes in biological matrices. A derivatisation method, which results in molecules that exhibit a common product ion on MS/MS, permits informative precursor ion scans, at high sensitivity. This has been applied to the examination of plasma in order to examine the production of aldehydes consequent on in vitro lipid oxidation. Quantitative analysis of target molecules using multiple reaction monitoring has been developed to permit quantitation in the same matrices.  相似文献   

19.
The metabolism of tanshinone IIA was studied in rats after a single-dose intravenous administration. In the present study, 12 metabolites of tanshinone IIA were identified in rat bile, urine and feces with two LC gradients using LC-MS/MS. Seven phase I metabolites and five phase II metabolites of tanshinone IIA were characterized and their molecular structures proposed on the basis of the characteristics of their precursor ions, product ions and chromatographic retention time. The seven phase I metabolites were formed, through two main metabolic routes, which were hydroxylation and dehydrogenation metabolism. M1, M4, M5 and M6 were supposedly tanshinone IIB, hydroxytanshinone IIA, przewaquinone A and dehydrotanshinone IIA, respectively, by comparing their HPLC retention times and mass spectral patterns with those of the standard compounds. The five phase II metabolites identified in this research were all glucuronide conjugates, all of which showed a neutral loss of 176 Da. M9 and M12 were more abundant than other identified metabolites in the bile, which was the main excretion path of tanshinone IIA and the metabolites. M12 was the main metabolite of tanshinone IIA. M9 and M12 were proposed to be the glucuronide conjugates of two different semiquinones and these semiquinones were the hydrogenation products of dehydrotanshinone IIA and tanshinone IIA, respectively. This hydrogenized reaction may be catalyzed by the NAD(P)H: quinone acceptor oxidoreductase (NQO). The biotransformation pathways of tanshinone IIA were proposed on the basis of this research.  相似文献   

20.
The determination of nicotine and its major metabolites (cotinine and anabasine) in fish tissue was performed using liquid chromatography and tandem mass spectrometry. Marine and freshwater fish were purchased from local grocery stores and were prepared based on a quick, easy, cheap, effective, rugged, and safe sample preparation protocol. To determine the highly polar compounds, hydrophilic interaction liquid chromatography was also used. There were modest suppressions on measured nicotine signals (10%) due to the matrix effects from marine fish but no obvious effects on freshwater fish signals. Method validation was incorporated with internal standards and carried out with matrix‐matched calibration. The detection limits for nicotine, cotinine, and anabasine were 9.4, 3.0, and 1.5 ng/g in fish, respectively. Precision was quite acceptable returning less than 8% RSD at low, medium, and high concentrations. Acceptable and reproducible extraction recoveries (70–120%) of all three compounds were achieved, except for anabasine at low concentration (61%). The method was then applied to define nicotine bioaccumulation in a fathead minnow model, which resulted in rapid uptake with steady state internal tissue levels, reached within 12 h. This developed method offers a fast, easy, and sensitive way to evaluate nicotine and its metabolite residues in fish tissues.  相似文献   