首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
A method to extract and analyze organic compounds from water is presented. A solid phase micro-trap (micro-SPE) directly connected to the micro-analytical column is used. Sensibility and specificity needed for trace analysis are guaranteed by mass spectrometric electron ionization (EI) detection. A new micro-HPLC/EI-MS interface called Capillary-EI (Cap-EI) is described. The ultimate evolution of this interface is also presented: in this extremely simplified interface the analytes are nebulized, vaporized and ionized in the small volume of the ion source. This interface, called Direct-EI, exploits nano- and micro-HPLC columns with a mobile phase flow rates ranging from 0.3 to 1.5 microL/min. Contemporary use of micro SPE, Cap-EI or Direct-EI gives us a powerful technique to identify and quantify organic pollutants at part per billion level (ppb).  相似文献   

2.
A 252Cf plasma desorption mass spectrometer has been set up to analyse thin layers of non-volatile organic samples. Molecular and fragment ions were produced and their mass was determined by a time-of-flight measurement. A novel interface combines a high-performance liquid chromatograph with the 252Cf plasma desorption mass spectrometer in a twofold way: introducing the effluent continuously through a capillary inlet in the on-line liquid chromatography mass spectrometry mode or transferring already prepared samples through a vacuum lock into the mass spectrometer in the off-line liquid chromatography+mass spectrometry mode. The off-line mode has been applied for the quantitative analysis of pharmaceuticals in blood using stable isotope labelled standards.  相似文献   

3.
The widely different LC-MS response observed for many structurally different compounds limits the use of LC-MS in full scan detection mode for quantitative determination of drugs and metabolites without using reference standard. The recently introduced nanospray ionization (NSI) technique shows comparable MS response for some compounds under non-LC-MS conditions. However, in the presence of numerous endogenous compounds commonly associated with biological samples such as urine, plasma, and bile, LC-MS is required to separate, detect, identify, and measure individual analytes. An LC-NSI-MS system was devised and the MS response obtained in this system for a variety of pharmaceutical drugs and their metabolites. The set-up involves two high-performance liquid chromatography (HPLC) systems, a chip-based NSI source and a quadrupole-time-of-flight (Q-TOF) mass spectrometer. Herein this is referred to as the response normalized-liquid chromatography NSI-MS (RNLC-NSI-MS) system. One HPLC unit performs the analytical separation, while the other unit adds solvent post-column with an exact reverse of the mobile phase composition such that the final composition entering the NSI source is isocratic throughout the entire HPLC run. The data obtained from four different structural classes of compounds [vicriviroc (VCV), desloratadine (DL), tolbutamide, and cocaine] and their metabolites indicate that by maintaining the solvent composition unchanged across the HPLC run, the influence of the solvent environment on the ionization efficiency is minimized. In comparison to responses obtained from radiochromatograms, responses from conventional LC-ESI-MS overestimated the VCV and DL responses, respectively, by 6- and 20-fold. Although VCV and DL responses obtained using LC-NSI-MS are within 2- to 6-fold from the respective radiochromatographic responses, the response normalization modification results in nearly uniform LC-NSI-MS response for all compounds evaluated.  相似文献   

4.
5.
Mass spectrometry (MS) is one of the most powerful instrumental techniques for protein analysis. The electrospray ionization (ESI) approach is known to be very gentle and at the same time compatible with liquid separation techniques such as HPLC and CE. However, ESI is known to be susceptible to salts and impurities, which often cause a dramatic decrease in sensitivity due to the suppression of the ionization of the product of interest. For this reason, LC-ESI-MS coupling has so far been largely limited to reversed-phase chromatography with its hydro-organic mobile phases. Other chromatographic techniques are typically "linked" to ESI-MS by time consuming, off-line desalting steps. On-line microdialysis has been proposed as a solution to this dilemma. In this paper, we introduce an improved microdialysis system, which enlarges the number of putative applications, thus allowing chromatographic separations of biological compounds to be directly coupled to MS detection with little to no loss in time or chromatographic resolution. Examples include separations by affinity, ion-exchange and size-exclusion chromatography, all of which were connected successfully to the ESI-MS detector via the on-line microdialyzer. We propose that, using this system, any kind of chromatography technique can be coupled to ESI-MS, thus enabling for example application in quality control or process monitoring of many bioproduction and downstream processes.  相似文献   

6.
Sorbic acid (SA: CH(3)-CH=CH-CH=CH-COOH) and its salts are widely used as preservatives in foodstuff because of their growth inhibitory effects on mold, yeast and a wide range of bacteria. However, it is still unclear whether SA and its salts are actually incorporated in these organisms and a higher organisms like mammalian cells. Acidic compounds such as SA are usually analyzed by HPLC with eluents containing acetic acid, formic acid and their ammonium acetates, but such acidic buffers may suppress the ionization efficiency of the acidic compounds in negative-mode electrospray ionization (ESI). In this study, we present a sensitive and simple method for analysis of SA by HPLC with non-acidic solvents such as CH(3)CN/CH(3)OH-H(2)O by negative ion mode ESI-LC/MS. As a result, SA at less as 30 fmol was selectively determined by the selected reaction monitoring (SRM) mode. It was defined as the peak area with a signal-to-noise ratio (S/N) of 3. Good linearity was obtained in the range from 55 fmol (S/N 3) to 500 fmol (r(2)=0.9968) for SA by using LC/MS with the SRM mode. We also show that the method is useful to analyze SA level in the cytosol of mastocytoma cells, which were pretreated with SA. These results suggest the applicability of this method for the highly sensitive determination of SA in the mammalian tissues and cells.  相似文献   

7.
Flow splitting to a mass spectrometer is a common way of coupling a highly specific detector to preparative or semi-preparative high-performance liquid chromatography (HPLC) purification of combinatorial libraries, drug metabolites, and characterizable impurities. The sensitive mass spectrometer consumes only a small fraction of the analyte while providing online structure-specific detection, and its output can thus be used to trigger collection of the desired fraction. Coupling mass spectrometry to preparative HPLC is difficult due to the susceptibility of the detector to fouling under conditions of high analyte concentration or solute amount, or to changes in solvent composition. We report here on a device, the mass rate attenuator (MRA), which automatically produces split ratios over a range of 100:1 to 100 000:1 under programmable user control. The MRA is a flow-control device that periodically gates a small aliquot from one liquid stream into another. The design allows the user to set the frequency of the gating without interruption of the HPLC flow stream. The MRA also allows control of the volume of the aliquot that is transferred between the flow streams. This additional control, compared to passive splitting devices, facilitates optimization of the tubing connecting the separation, detection and collection events. We demonstrate that such optimization can reduce the volume of the collected fraction without compromising recovery, thus reducing the time spent in evaporating solvents to reclaim purified products.  相似文献   

8.
We report on the development of a new laser-ionization (LI) source operating at atmospheric pressure (AP) for liquid chromatography/mass spectrometry (LC/MS) applications. APLI is introduced as a powerful addition to existing AP ionization techniques, in particular atmospheric-pressure chemical ionization (APCI), electrospray ionization (ESI), and atmospheric pressure photoionization (APPI). Replacing the one-step VUV approach in APPI with step-wise two-photon ionization strongly enhances the selectivity of the ionization process. Furthermore, the photon flux during an ionization event is drastically increased over that of APPI, leading to very low detection limits. In addition, the APLI mechanism generally operates primarily directly on the analyte. This allows for very efficient ionization even of non-polar compounds such as polycyclic aromatic hydrocarbons (PAHs). The APLI source was characterized with a MicroMass Q-Tof Ultima II analyzer. Both the effluent of an HPLC column containing a number of PAHs (benzo[a]pyrene, fluoranthene, anthracene, fluorene) and samples from direct syringe injection were analyzed with respect to selectivity and sensitivity of the overall system. The liquid phase was vaporized by a conventional APCI inlet (AP probe) with the corona needle removed. Ionization was performed through selective resonance-enhanced multi-photon ionization schemes using a high-repetition-rate fixed-frequency excimer laser operating at 248 nm. Detection limits well within the low-fmol regime are readily obtained for various aromatic hydrocarbons that exhibit long-lived electronic states at the energy level of the first photon. Only molecular ions are generated at the low laser fluxes employed ( approximately 1 MW/cm(2)). The design and performance of the laser-ionization source are presented along with results of the analysis of aromatic hydrocarbons.  相似文献   

9.
The feasibility and advantages of using sophisticated chemometric tools in combination with the execution of thoroughly planned experiments to determine experimental conditions for optimal performance of an LC-ESI-MS/MS analysis is demonstrated. A stepwise strategy is proposed, which provides a controlled optimization procedure of the chromatographic quality (in terms of separation among the sample constituents) and maximizes the mass spectrometric signal of the selected product ions. Design of experiments (DOE) and response surface methodology are applied throughout the procedure. The stepwise approach has the advantage of dealing with the different optimization criteria separately, i.e. first ensuring sufficient chromatographic separation, then maximizing the amount of precursor ion entering the mass spectrometer, and finally generating high amounts of selected product ions. The experiments are performed on a linear ion trap mass spectrometer. Retention mapping using the band-tracking model is applied during LC development, which facilitates the optimization of segmented gradients. A set of different siderophores, strong iron chelates, is used as the model substances.  相似文献   

10.
Some people look at the particle-beam interface as an object of the past in a changing world of promising new instrumentation. We believe that generating EI spectra, when possible, is a short cut to the solution of many analytical problems. We are convinced that this approach is valid, but the hardware can surely benefit of new ideas in order to follow adequately the rapid technical evolution of mass spectrometry. In the last 5 years, our research group has deeply investigated the functioning of the particle-beam interface and has proposed a few improvements for its performance. In the following pages, this research effort is described with a particular emphasis on the future evolution of the use of the electron ionization of a liquid effluent.  相似文献   

11.
12.
The results of copolymer characterization by coupling of chromatography and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) techniques and subsequent calculation of copolymer composition using a novel software tool 'MassChrom2D' are presented. For high-resolution mass analysis copolymer samples were fractionated by means of liquid adsorption chromatography (LAC). These fractions were investigated off-line by MALDI-TOF MS. Various mono-n-butyl ethers of polyethylene oxide-polypropylene oxide copolymers (PEO-co-PPO) were investigated. As well as the copolymer composition presented in two-dimensional plots, the applied approach can give additional hints on specific structure-dependent separation conditions in chromatography.  相似文献   

13.
Analytical techniques for the detection of small amounts of explosives (in the picogram range) are now involved in various application. Some of them concern soil, water and air monitoring in order to face environmental problems related to improper handling procedures either in stocking or in wasting of the explosive products. Other areas are strictly related to forensic analysis of samples coming either from explosion areas where the matrix is various (metal, glass, wood, scraps), or from explosives transportation related to international terrorism. Generally speaking, for these applications the bulk of the matrix seriously interferes in the detection of the explosive analyte, which is usually present at trace levels. Unfortunately, despite some improvements, analytical techniques developed up today in this domain are still faced to two main constraints: the introduction of new products with unanticipated chemico-physical properties and the requirement of a routine and fast analytical method which can handle any matrix with a minimal clean-up and performing a sensitivity compatible either with the ever-decreasing demanded detection limit and with the ever-decreasing available specimen amount. These requirements can be fulfilled now by the new LC-MS and LC-MSMS techniques: mass spectrometry (MS) is likely an universal detector but even specific, especially when implemented in tandem MS (MSMS); LC is by far the most suitable technique to handle such a kind of compounds. Moreover, of a particular concern are some explosives which are reported to be thermally stable but difficult to dissolve. Some of the experiments on characterization of explosives [Octagen (HMX), Ethyleneglycol dinitrate (EGDN), Exogen (RDX), Propanetriol trinitrate (NG), Trinitrotoluene (TNT), N-Methyl-N-tetranitrobenzenamine (TETRYL), Dintrotoluene (DNT), Bis-(nitrooxy-methyl) propanediol dinitrate (PETN), Hexanitrostilbene (HNS), Triazido-trinitrobenzene (TNTAB), Tetranitro-acridone (TENAC), Hexa-nitrodiphenylamine (HEXYL), Nitroguanidine (NQ)] by LC-MS and LC-MSMS with the API-IonSpray source and using the Parent-Scan technique are presented.  相似文献   

14.
Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds.  相似文献   

15.
Tomato (Lycopersicon esculentum Mill.) is the second most important fruit crop worldwide. Tomatoes are a key component in the Mediterranean diet, which is strongly associated with a reduced risk of chronic degenerative diseases. In this work, we use a combination of mass spectrometry (MS) techniques with negative ion detection, liquid chromatography/electrospray ionization linear ion trap quadrupole‐Orbitrap‐mass spectrometry (LC/ESI‐LTQ‐Orbitrap‐MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) on a triple quadrupole, for the identification of the constituents of tomato samples. First, we tested for the presence of polyphenolic compounds through generic MS/MS experiments such as neutral loss and precursor ion scans on the triple quadrupole system. Confirmation of the compounds previously identified was accomplished by injection into the high‐resolution system (LTQ‐Orbitrap) using accurate mass measurements in MS, MS2 and MS3 modes. In this way, 38 compounds were identified in tomato samples with very good mass accuracy (<2 mDa), three of them, as far as we know, not previously reported in tomato samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
The quantitative determination of nucleotides from DNA modified by styrene oxide is described using a combination of inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) and electrospray ionization mass spectrometry (ESI-MS), both interfaced to reversed-phase high-performance liquid chromatography (HPLC). LC/ICP-MS (resolution > 1500 to discriminate against 15N16O+ and 14N16OH+) was employed to determine quantitatively the content of modified nucleotides in standard solutions based on the signal of phosphorus; phosphoric acid served as an internal standard. By means of the standard addition technique the sensitivity of the LC/ESI-MS approach was subsequently determined. Since a comparison of UV, ICP and ESI-MS data suggested that in ESI-MS the ionization efficiency of the adducts is identical within the error limits, quantitative determination of all adducts is possible. For LC/ESI-MS with single ion monitoring, the detection limit for styrene oxide adducts of nucleotides was determined to be 20 pg absolute or 14 modified in 10(8) unmodified nucleotides in a 5 micrograms DNA sample, which comes close to the best methods available for the detection of chemical modifications in DNA.  相似文献   

17.
Grape antioxidant dietary fiber (GADF) is a dietary supplement that combines the benefits of both fiber and antioxidants that help prevent cancer and cardiovascular diseases. The antioxidant polyphenolic components in GADF probably help prevent cancer in the digestive tract, where they are bioavailable. Mass spectrometry coupled to liquid chromatography is a powerful tool for the analysis of complex plant derivatives such as GADF. We use a combination of MS techniques, namely liquid chromatography/electrospray ionization time-of-flight mass spectrometry (LC/ESI-TOF-MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) on a triple quadrupole, for the identification of the polyphenolic constituents of the soluble fraction of GADF. First, we separated the mixture into four fractions which were tested for phenolic constituents using the TOF system in the full scan mode. The high sensitivity and resolution of the TOF detector over the triple quadrupole facilitate the preliminary characterization of the fractions. Then we used LC/ESI-MS/MS to identify the individual phenols through MS/MS experiments (product ion scan, neutral loss scan, precursor ion scan). Finally, most of the identities were unequivocally confirmed by accurate mass measurements on the TOF spectrometer. LC/ESI-TOF-MS combined with MS/MS correctly identifies the bioactive polyphenolic components from the soluble fraction of GADF. High-resolution TOF-MS is particularly useful for identifying the structure of compounds with the same LC/ESI-MS/MS fragmentation patterns.  相似文献   

18.
Native cyclodextrin-based columns are particularly useful for the analysis of oligosaccharides because the retention of these carbohydrates is based mainly on the hydrogen bonding interactions of oligosaccharide hydroxyl groups with the stationary phase. Thus, the retention time predictably increases with the number of analyte hydroxyl groups, which corresponds to the elongation of the oligosaccharide chain. High-performance liquid chromatography (HPLC) coupled to electrospray ionization (ESI) mass spectrometry (MS) was used for the separation and characterization of underivatized oligosaccharide mixtures. With the limits of detection as low as 50 pg, all individual components of oligosaccharide mixtures (up to 11 glucose units long) were baseline resolved on a Cyclobond I 2000 column and detected using ESI-MS. Low flow rates and narrow I.D. columns increase the ESI-MS sensitivity significantly. The method showed potential usefulness for the sensitive and quick analysis of hydrolysis products of polysaccharides, and for trace levels of individual oligosaccharide or oligosaccharide isomers from biological systems.  相似文献   

19.
The explosive triacetone triperoxide (TATP) has been analyzed by gas chromatography/mass spectrometry (GC/MS) and sub-nanogram detection limits are reported by ammonia positive ion chemical ionization (PICI), electron ionization (EI) and methane negative ion chemical ionization (NICI). Analysis by methane PICI and ammonia NICI gave detection limits in the low nanogram range. Analyses were carried out on (linear) quadrupole and ion trap instruments. Analysis of TATP by PICI using ammonia reagent gas is the preferred analytical method, producing low limits of detection as well as an abundant (greater than 60% of base peak) diagnostic adduct ion at m/z 240 corresponding to [TATP + NH4]+. Isolation of the [TATP + NH4]+ ion with subsequent collision-induced dissociation (CID) produces extremely low abundance product ions at m/z values greater than 60, and the m/z 223 ion corresponding to [TATP + H]+ was not observed. Density functional theory (DFT) calculations at the B88LYP/DVZP level indicate that dissociation of the complex to form NH4+ and TATP occurs at energies lower than peroxide bond dissociation, while protonation of TATP leads to cleavage of the ring structure. These results provide a method for pico-gram detection levels of TATP using commercial instrumentation commonly available in forensic laboratories. As a point of comparison, a detection limit of 15 ng was obtained by flame ionization detection.  相似文献   

20.
The evolution of atmospheric pressure ionization techniques which are now routinely applied as liquid chromatograph/mass spectrometer (LC/MS) interfaces is described. Electrospray and related methods, as well as atmospheric pressure chemical ionization combined with the heated nebulizer interface, both began as specialized ionization techniques which became much more widely accepted when combined with tandem mass spectrometry. Today, both are widely used for quantitative and qualitative LC/MS and LC/MS/MS analyses. Important events in the development of these methods are described, along with key elements in the evolution of the ion source-to-vacuum interface techniques that contributed to their success.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号