首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The efficiency of microwave-assisted extraction (MAE) was evaluated for the analysis of polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) in fish. An isotope dilution method was used for quantification via analysis of the samples by gas chromatography and mass spectrometry. MAE solvent, temperature, and time were optimized, and observed concentrations were compared. The MAE results were also compared to those of other extraction techniques (Soxhlet extraction, pressurized liquid extraction, saponification, and homogenization). Concentrations of PCBs and OCPs obtained by MAE at 120 degrees C for 10 min were comparable to those by the other techniques. The results suggest that MAE can be used for the analysis of PCBs and OCPs in fish.  相似文献   

2.
The hyphenated technique namely microwave-assisted headspace solid-phase microextraction (MA-HS-SPME) was developed and studied for the simultaneous extraction/enrichment of polychlorinated biphenyls (PCBs) in aqueous samples prior to the quantification by gas chromatography (GC). The PCBs in aqueous media are extracted onto a solid-phase micro fibre via the headspace with the aid of microwave irradiation. The optimum conditions for obtaining extraction efficiency, such as the extraction time, addition of salts, addition of methanol, ratio of sample to headspace volume, and the desorption parameters were investigated. Experimental results indicated that the proposed MA-HS-SPME method attained the best extraction efficiency under the optimized conditions, i.e., irradiation of extraction solution (20 ml aqueous sample in 40 ml headspace vial with no additions of salt and methanol) under 30 W microwave power for 15 cycles (1 min power on and 3 min power off of each cycle). Desorption at 270 degrees C for 3 min provided the best detection results. The detection limit obtained were between 0.27 and 1.34 ng/l. The correlation coefficient for the linear dynamic range from 1 to 80 ng/l exceeded 0.99 for 18 PCBs.  相似文献   

3.
Optimisation of microwave-assisted extraction (MAE) for the extraction of polychlorinated biphenyls (PCBs) from soil samples has been accomplished using an experimental design approach. Variables studied have been: percentage of acetone (v/v) in an acetone:n-hexane mixture, solvent volume, extraction time, microwave power and pressure inside the extraction vessel. Five samples of a certified soil (CRM 481) have been extracted under the optimum conditions of the developed method and the results have been compared to those obtained by Soxhlet extraction. Good recoveries (>95%) have been obtained for all the PCBs studied. All extracts have been analysed by gas chromatography/mass spectrometry (GC/MS) and an optimum determination method for the electron impact mass spectrometric (EIMS) has also been developed.  相似文献   

4.
A procedure focused on microwave-assisted extraction in open vessel (MAE-OV) and gas chromatography with electron capture detection (GC-ECD) was used for the determination of 26 congeners of polychlorinated biphenyls (PCBs) in soil samples. The limit of detection (LOD) and limit of quantification (LOQ) were evaluated for commercial PCBs mixture Aroclor1260. LOD and LOQ were calculated for each PCB congener, in the ranges (0.03–0.27?ng?g?1) and (0.11–0.70?ng?g?1), respectively. After optimization, 26 PCBs congeners were successfully extracted from soil samples with recovery amounts ranging between 84.7% and 117.3% for all PCBs congeners. The evaluated method of MAE-OV showed good separation and extraction of all PCBs congeners from soil samples. Extraction parameters such as solvent choice, power and extraction time were investigated. This study indicated that MAE-OV could be an interesting alternative method to extract PCBs from soils, since it is economical, easy, fast and requires low amounts of solvents.  相似文献   

5.
A procedure for the determination of 17 chlorophenolic compounds in ash samples obtained from the incineration of waste materials is described. Analytes were simultaneously derivatized with acetic anhydride in presence of triethylamine (TEA), and extracted from the sample in a mixture of n-hexane acetone using a microwave system equipped with closed extraction vessels. Influence of five experimental parameters (volume of TEA and acetic anhydride, extraction time and temperature, as well as the volume of n-hexane acetone) on the yield of the derivatization-extraction procedure was systematically studied using a uniform experimental design at four levels, followed by a conventional factorial design at two levels. Under optimal extraction conditions, recoveries from 72 to 94% were obtained for a spiked ash sample with a carbon content of 8.7%. Quantification limits of the proposed procedure ranged from 2 to 5 ng/g using GC-MS as detection technique. The proposed method was applied to the determination of chlorophenols in three ash samples obtained from different incineration plants. Total chlorophenol contents of 423 and 135 ng/g were found in two of these samples.  相似文献   

6.
Three commonly applied extraction techniques for persistent organic chemicals, Soxhlet extraction (SE), accelerated solvent extraction (ASE) and microwave-assisted extraction (MAE), were applied on soil and fish samples in order to evaluate their performances. For both PCBs and PBDEs, the two more recent developed techniques (ASE and MAE) were in general capable of producing comparable extraction results as the classical SE, and even higher extraction recoveries were obtained for some PCB congeners with large octanol-water partitioning coefficients (Kow). This relatively uniform extraction results from ASE and MAE indicated that elevated temperature and pressure are favorable to the efficient extraction of PCBs from the solid matrices. For PBDEs, difference between the results from MAE and ASE (or SE) suggests that the MAE extraction condition needs to be carefully optimized according to the characteristics of the matrix and analyte to avoid degradation of higher brominated BDE congeners and improve the extraction yields.  相似文献   

7.
The application of a new focused microwave-assisted Soxhlet extractor for the extraction of polychlorinated biphenyls from differently aged soils is here presented. The new extractor overcomes the disadvantages of previous devices based on the same principle and enables a fully automated extraction of two samples simultaneously. The variables affecting the extraction step (namely, power of irradiation, irradiation time, extractant volume, extractant composition and number of extraction cycles) have been optimized using experimental design methodology. The optimized method has also been applied to a certified reference material (CRM910-050 "real" contaminated soil) for quality assurance validation. Quantification of the target compounds has been performed by GC with ion-trap MS. The mass spectrometer was operated in the electron-ionization mode, with selected-ion monitoring at m/z 152, 186, 292, 326 and 498. The results obtained have demonstrated that this approach is as efficient as conventional Soxhlet but with a drastic reduction of both extraction time (70 min vs. 24 h for the "real" contaminated soil) and organic solvent disposal, as 75-80% of the extractant is recycled.  相似文献   

8.
A microwave-assisted extraction (MAE) technique for the determination of polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) in marine sediment samples has been investigated. The analytes were extracted under different treatment conditions, such as temperature, time and extraction solvent. They were quantified by an isotope-dilution method, and the observed concentrations and recovery yields obtained under different conditions were compared. The results of a comparison between this MAE and other extraction techniques, such as pressurized fluid extraction, saponification, sonication, and Soxhlet extraction, are also given in this report. The techniques gave comparable results with the values obtained by other extraction techniques and the certified values in the samples. However, the observed concentration values of mono- and dichlorinated biphenyls varied depending on the extraction temperature.  相似文献   

9.
Polychlorinated biphenyls (PCBs) in water were extracted with a rebuilt extraction unit using 47 mm C18 solid-phase extraction (SPE) disks. Three types of disks (SPEC, ENVI and Empore) were investigated for the extraction of seven PCBs from 11 reagent water spiked at two concentration levels (20 and 1000 ng/l). The Empore disks produced the best analyte recoveries (91-107% with R.S.D. of 1-8%) at the low concentration level and displayed no leaking tendency. Empore disks were therefore considered superior to ENVI and SPEC disks for the conditions outlined in this work. The obtained extracts were dried and purified in an additional clean-up step using custom-made columns containing Florisil and Na2SO4. For water containing large amounts of organic matter, a pre-filtration was included. Final analysis was carried out on a dual-column GC-electron-capture detection system with on-column injection. The optimised extraction method, including clean-up, was less time-consuming and used less hazardous organic solvents than conventional liquid-liquid extraction (LLE) methods. Recoveries were 92-102% with R.S.D. of 3-8%.  相似文献   

10.
The extraction and determination of chlorinated biphenyls (CBs) in soils and solid wastes is an ongoing subject of study. This is an overview article that compares the microwave-assisted extraction (MAE) and accelerated solvent extraction (ASE) techniques. The extraction of CBs by ASE has been optimised taking into account the variation of pressure, temperature and extraction time by means of experimental design and the Simplex approach. The recoveries obtained under the optimum conditions are compared and discussed with those obtained from MAE and Soxhlet extractions.  相似文献   

11.
2,3,7,8-Substituted polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDD/Fs) and non-ortho-substituted polychlorinated biphenyls (PCBs) account for almost all of the total toxic equivalents (TEQ) in environmental samples. Activated carbon columns are used to fractionate the samples for GC-MS analysis or bioassay. Micropore-free surface-activated carbon is highly selective for PCDD/Fs and non-ortho-PCBs and can improve the conventional activated carbon column clean-up. Along with sulfuric acid-coated diatomaceous earth columns, micropore-free surface-activated carbon provides a rapid, robust, and high-throughput sample preparation method for PCDD/Fs and non-ortho-PCBs analysis.  相似文献   

12.
Pressurized liquid extraction (PLE) is a relatively new technique applicable for the extraction of persistent organic pollutants from various matrices. The main advantages of this method are short time and low consumption of extraction solvent. The effects of various operational parameters (i.e. temperature of extraction, number of static cycles and extraction solvent mixtures) on the PLE efficiency were investigated in this study. Fish muscle tissue containing 3.2% (w/w) lipids and native polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and other related compounds was used for testing. Purification of crude extracts was carried out by gel permeation chromatography employing Bio-Beads S-X3. Identification and quantitation of target indicator PCBs and OCPs was performed by high-resolution gas chromatography (HRGC) with two parallel electron-capture detectors (ECDs). Results obtained by the optimized PLE procedure were compared with conventional Soxhlet extraction (the same extraction solvent mixtures hexane–dichloromethane (1:1 v/v) and hexane–acetone (4:1 v/v) were used). The recoveries obtained by PLE operated at 90–120 °C were either comparable to “classic” Soxhlet extraction (for higher-chlorinated PCB congeners and DDT group) or even better (for lower chlorinated analytes). The highest recoveries were obtained for three static 5 min extraction cycles.  相似文献   

13.
A fast clean-up procedure for the low level analysis of polychlorinated dibenzo-p-dioxins. polychlorinated dibenzofurans and coplanar polychlorinated biphenyls in highly fatty biological matrices using high capacity disposable multi-layer silica columns is presented. Results were compared with gel permeation chromatography for removal of lipids. Analytical criteria such as recovery rates, repeatability, reproducibility and robustness are evaluated through a broad range of biological matrices and reference materials analysis. The final proposed procedure for the complete analysis, including pressurized liquid extraction, Power-Prep system clean-up and GC-high-resolution MS analysis requires only 48 h, and allows the simultaneous preparation of up to 10 samples.  相似文献   

14.
The adsorptive potential of hexagonal boron nitride nanosheets (h-BNNSs) for solid-phase extraction (SPE) of pollutants was investigated for the first time. Seven indicators of polychlorinated biphenyls (PCBs) were selected as target analytes. The adsorption of PCBs on the surface of the h-BNNSs in water was simulated by the density functional theory and molecular dynamics. The simulation results indicated that the PCBs are adsorbed on the surface by π–π, hydrophobic, and electrostatic interactions. The PCBs were extracted with an h-BNNS-packed SPE cartridge, and eluted by dichloromethane. Gas chromatography–tandem mass spectrometry working in the multiple reaction monitor mode was used for the sample quantification. The effect of extraction parameters, including the flow rate, pH value, breakthrough volume, and the ionic strength, were investigated. Under the optimal working conditions, the developed method showed low limits of detection (0.24–0.50 ng L−1; signal-to-noise ratio = 3:1), low limits of quantification (0.79–1.56 ng L−1; signal-to-noise ratio = 10:1), satisfactory linearity (r > 0.99) within the concentration range of 2–1000 ng L−1, and good precision (relative standard deviation < 12%). The PCBs concentration in environmental water samples was determined by the developed method. This results demonstrate that h-BNNSs have high analytical potential in the enrichment of pollutants.  相似文献   

15.
Criado MR  Pereiro IR  Torrijos RC 《Talanta》2004,63(3):533-540
A procedure for the determination of several coplanar and non coplanar PCBs in ash samples is described. Analytes were extracted from the samples using dimethylsulfoxide (DMSO) under the action of a microwave field, and then they were concentrated on a PDMS-DVB solid-phase microextraction (SPME) fibre using the headspace mode, after water dilution of the DMSO extract. Determinations were carried out using GC-ECD and GC-MS detection. Influences of microwave extraction (solvent volume, temperature and time) and SPME conditions (stirring, kind of SPME fibre, salt and water addition, sampling time and temperature) on the performance of the whole analytical procedure were systematically investigated. Working under optimal conditions quantification limits from 0.2 to 1.5 ng g−1 were obtained for all the compounds, except for PCB 209, which could not be consistently extracted from the sample using the proposed conditions.  相似文献   

16.
In order to reduce time and cost of analysis, a new pressurised liquid extraction method that automatically and rapidly achieves quantitative and selective (i.e., lipid-free) extraction of polychlorinated biphenyls (PCBs) in biota tissues was optimized. It consists of on-line clean-up by inclusion of sorbents in the extraction cell. The freeze-dried sample is dispersed with Florisil and loaded in the extraction cell containing an extra amount of Florisil. The extraction is performed under mild conditions using 55 ml of a dichloromethane-pentane (15:85) mixture, a temperature of 40 degrees C, a static extraction time of 10 min and two extraction cycles. The Florisil retains coextracted lipids from the matrix, and the extract, after pre-concentration, is clean enough for direct injection into GC-MS and GC-electron-capture detection (ECD). Quantitative recoveries (from 90 to 106%) are obtained for both native and spiked PCB congeners in samples with a high lipidic content (up to 42% dry mass, in spoonbill eggs). The reproducibility of replicate extractions was better than 11% relative standard deviation. Method detection limits were in the ranges of 0.001-0.004 and 0.002-0.07 ng g(-1) dry mass for GC-ECD and GC-MS-MS, respectively. The method was validated using the standard reference material SRM 2974 (a mussel tissue) from the US National Institute of Standards and Technology, compared to Soxhlet and matrix solid-phase dispersion extraction methods, and used to evaluate the contamination by PCBs in bivalves from South of Spain.  相似文献   

17.
A new method was developed for the simultaneous extraction of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), phthalate esters (PEs), nonylphenols (NPs) and nonylphenol mono- and diethoxylates (NP1EOs and NP2EOs, respectively) in sediment samples by means of a closed microwave system. The extractions were carried out at 21 psi and 80% of microwave power and 15 ml of acetone were used as the common extraction solvent. The filtered extract was further fractionated in two groups using Florisil cartridges: PAHs and PCBs were eluted with n-hexane:toluene (4:1) and the PEs, NPs and ethoxylates were eluted with ethyl acetate. All the compounds were analysed by gas chromatography-mass spectrometry (GC-MS). In case of PAHs and PCBs, the developed method was validated by comparison of the results obtained for the certified reference material NIST 1944 with the certified values. In the absence of a reference material for phthalate esters and nonylphenols, one sediment sample was extracted twice under the optimal conditions in order to check than an exhaustive extraction of the analytes occurred. This method is currently used in the study of the distribution of those organic contaminants in the estuaries of the Bay of Biscay (Spain).  相似文献   

18.
This paper reports on the first use of supercritical fluid extraction (SFE) of polychlorinated biphenyls (PCBs) from pine needles. Supercritical carbon dioxide was used as extraction fluid, and exhibited good extraction efficiencies and recoveries (>90%). GC-MS (selected ion monitoring mode) achieved both accurate identification and quantification of the PCBs. Compared with traditional time consuming multi-step sample preparation methods, SFE with carbon dioxide is easier to perform, and is a feasible alternative extraction procedure for the monitoring of PCBs in pine needle samples.  相似文献   

19.
A direct competitive ELISA for determination of polychlorinated biphenyls (PCB) in soil samples was described. The standard calibration curve based on Delor 103 (Aroclor 1242) was constructed in the dynamic range of 10-1000 micro g L(-1) and a detection limit of 5.0-12.9 micro g L(-1) (or 0.5-1.29 micro g g(-1) soil) was achieved. When spiked soil samples were extracted with methanol recoveries were 90.6-106.3 %. The effect of methanol and DMSO on assay signal and sensitivity was established. Eight PCB-contaminated soil samples were analyzed by ELISA and gas chromatography (GC). The ELISA results from Soxhlet extraction were in a good agreement with those of GC (correlation coefficient 0.9866; n=8). Except for one soil sample the results from ELISA with methanol extraction were not significantly different from those from GC.  相似文献   

20.
Selective pressurized liquid extraction (PLE) of polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (dl-PCBs) from various food and feed samples was performed with a selective PLE method previously developed for bulk PCBs. The method utilizes sulfuric acid impregnated silica inside the extraction cell to oxidize coextracted fat. Extractions were performed at 100 degrees C with n-heptane for 5 min in two cycles. Data obtained by selective PLE combined with gas chromatography/high-resolution mass spectrometry (GC-HRMS) were compared to concentrations derived from reference laboratories applying conventional sample preparation and GC-HRMS. Experiments performed on spiked vegetable oil, naturally contaminated crude fish oil and oil containing compound feed samples showed good results for these relatively simple matrices. The accuracy was generally +/-20% as compared to spiked levels or to values obtained by the reference laboratories. The precision, measured as the relative standard deviation (RSD) for 2,3,7,8-tetrachlorodibenzo-p-dioxin toxic equivalency values (TEQs), was below 10% in all cases. The method was also tested on naturally contaminated herring tissue, chicken tissue, pork tissue and sepiolitic clay, which all caused some trouble. It was observed that sufficient amounts of sodium sulfate should be used for dehydration of tissue samples and additionally, the cells should not be packed too dense in order to avoid suppressed extraction efficiency. Once this was attended to, satisfactory data could be obtained, except for sepiolithic clay. This study demonstrates that selective PLE can be applied with success to a number of food and feed matrices in analysis of PCDD/Fs and dl-PCBs. Since the fat removal step is on-line, the selective PLE method will reduce time and solvent consumption for sample preparation as compared to traditional clean-up.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号