首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new fluorescein-based fluorescent derivatizating reagent, 6-oxy-(acetyl piperazine) fluorescein (APF), has been designed, synthesized and developed for carboxylic acid labeling. It was used as a pre-column derivatizing reagent for the determination of seven free fatty acids (lauric acid, myristic acid, arachidonic acid, linoleic acid, palmitic acid, oleic acid, and stearic acid) with high-performance liquid chromatography (HPLC). The derivatization reaction of APF with seven fatty acids was completed at 60 degrees C for 1 h using 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC) as the condensing reagent. On a C18 column, the derivatives of APF with seven free fatty acids could be separated completely in 22 min using a mobile phase of methanol-water (88:12, v/v) containing 7 mmol L(-1) pH 6.5 Na2HPO4-H3Cit3 buffer with fluorescence detection at lambdaex/lambdaem=467/512 nm. The detection limits could reach 0.1-6.4 nmol L(-1) (signal-to-noise=3). This reagent was applied to the determination of the free fatty acids in human serum samples with satisfying recovery efficiencies varying from 93 to 105%.  相似文献   

2.
Cao L  Wang H  Ma M  Zhang H 《Electrophoresis》2006,27(4):827-836
An MEKC-LIF method using 6-oxy-(N-succinimidyl acetate)-9-(2'-methoxy-carbonyl) fluorescein (SAMF) newly synthesized in our lab as a labeling reagent for the separation and determination of eight typical biogenic amines was proposed. After careful study of the derivatization condition such as pH value, reagent concentration, temperature, and reaction time, derivatization reaction was accomplished as quickly as 10 min with stable yield. Optimal separation of SAMF-labeled amines was achieved with a running buffer (pH 9.3) containing 30 mM boric acid, 25 mM SDS, and 20% v/v ACN. The proposed method allowed biogenic amines to be determined with LODs as low as 0.25-2.5 nmol/L and RSD values from 0.4 to 4.5%. The present method has been successfully used to monitor biogenic amines in HeLa cells and fish samples. This study exploits the potential of MEKC-LIF with SAMF labeling as a tool for monitoring biogenic amines involved in complex physiological and behavioral processes in various matrices.  相似文献   

3.
The fluorescent reagent 6-oxy-(N-succinimidyl acetate)-9-(2′-methoxycarbonyl)fluorescein (SAMF), has been newly synthesized for use as a label for characterization of phosphoamino acids by micellar electrokinetic capillary electrophoresis (MEKC) with laser-induced fluorescence (LIF) detection. The conditions for derivatization and separation of the phosphoamino acids, including pH, concentration of electrolyte, and Brij-35 concentration were optimized in detail. Derivatization was performed at 35 °C for 10min in borate buffer (pH 8.0). The derivatives were separated to baseline by use of running buffer containing 50 mM borate and 20 mM Brij-35 at pH 9.3. Detection limits ranged from 5 × 10?11 to 1 × 10?9 mol L?1 (signal to noise ratio = 3). The method was used for characterization of the phosphoamino acids in a sample from hydrolysis of a novel protein kinase from tobacco cells.  相似文献   

4.
A simple, selective and sensitive approach was developed for the quantitation of aliphatic amines in lake water applying a new reagent (N-succinimidyl benzoate, SIBA), synthesized in the laboratory of the authors. Derivatization of the n-C1-C6 aliphatic monoamines and dimethylamine in aqueous solution with SIBA was followed by headspace solid-phase microextraction (SPME). Derivatives were identified by gas chromatography-mass spectrometry and determined by gas chromatography-flame ionization detection. Both derivatization and SPME conditions have been optimized. Derivatizations were performed in borate buffer (pH 8.8), at 60 degrees C for 22 min. SPME was carried out from saturated sodium chloride solution, at 80 degrees C for 60 min, desorption at 250 degrees C for 2 min. Detection limit of derivatized amines proved to be 0.13-7.2 nmol/l, while recovery of amines from lake water samples, in the concentration range of 100-200 microg/l, varied from 94.1 to 102.7%.  相似文献   

5.
Cao LW  Wang H  Liu X  Zhang HS 《Talanta》2003,59(5):973-979
A new amino fluorescence probe, 2,6-dimethylquinoline-4-(N-succinimidyl) formate (DMQF-OSu) has been synthesized. Based on the selective reaction of DMQF-OSu with primary and secondary aliphatic amines to yield strong fluorescence, a new spectrofluorimetric method for the determination of total aliphatic amines has been developed. At λex/λem=324.4/416 nm, the linear calibration range was 6×10−8-6×10−6 mol l−1 with the detection limit (3σ) of 1.94×10−10 mol l−1 for the determination of aliphatic amines in weak basic media. The proposed method has been applied to the determination of aliphatic amines in tap water and lake water with the recoveries of 99-104%. Compared with the reported methods, the method presented here is rapid, simple, sensitive and feasible.  相似文献   

6.
Cao L  Wang H  Zhang H 《Electrophoresis》2005,26(10):1954-1962
The analytical potential of a fluorescein analogue, 6-oxy-(N-succinimidyl acetate)-9-(2'-methoxycarbonyl) fluorescein (SAMF), for the first time synthesized in our laboratory, as a labeling reagent for the labeling and determination of amino compounds by capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection was investigated. Biogenic monoamines and amino acids were chosen as model analytes to evaluate the analytical possibilities of this approach. The derivatization conditions and separation parameters for the biogenic amines were optimized in detail. The derivatization was performed at 30 degrees C for 6 min in boric acid buffer (pH 8.0). The derivatives were baseline-separated in 15 min with 25 mM boric acid running buffer (pH 9.0), containing 24 mM SDS and 12.5% v/v acetonitrile. The concentration detection limit for biogenic amines reaches 8 x 10(-11) mol.L(-1) (signal-to-noise ratio = 3). The application of CE in the analysis of the SAMF-derivatized amino acids was also exploited. The optimal running buffer for amino acids suggested that weak acidic background electrolyte offered better separation than the basic one. The proposed method was applied to the determination of biogenic amines in three different beer samples with satisfying recoveries varying from 92.8% to 104.8%. Finally, comparison of several fluorescein-based probes for amino compounds was discussed. With good labeling reaction, excellent photostability, pH-independent fluorescence (pH 4-9), and the resultant widely suited running buffer pH, SAMF has a great prospect in the determination of amino compounds in CE.  相似文献   

7.
A highly sensitive method for the determination of bisphenol-A in water with semi-micro column high-performance liquid chromatography using 2-methoxy-4-(2-phthalimidinyl)phenylsulfonyl chloride as a fluorescent labeling reagent has been developed. The labeling reaction was carried out at 70 degrees C for 20 min in borate buffer (pH 9.5). The derivative eluted at 11.6 min on a reversed-phase column with methanol-water (78:22, v/v) at a flow-rate of 0.2 ml/min. The fluorescence was monitored at 308 nm for excitation and 410 nm for emission. The detection limit (S/N = 3) was 10 fmol per injection. The labeling yield was about 95%.  相似文献   

8.
Summary The use of 1,2-naphthoylenebenzimidazole-6-sulphochloride has been proposed as the reagent for derivatization of aliphatic amines prior to their separation, identification and quantitation both in HPLC and in TLC. The reaction of amines with this compound is quantitative and highly fluorescent derivatives are formed that provide favourable detection limits and sensitivity as compared to Dansyl derivatives of aliphatic amines. Actual detection limits achieved correspond to ca. 10–10 mol of the amine in a spot after elution from the thin-layer plate and to ca. 5·10–14 mol of the amine in a sample volume of 10 l injected into the liquid chromatograph. The use of this derivatization reagent offers good potential for the analysis of trace amounts of amines in environmental samples and in biological material.Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

9.
A new fluorogenic reagent 3-(4-fluorinebenzoyl)-2-quinoline carboxaldehyde (FBQCA) has been synthesized and used as a derivatizing reagent for the determination of aliphatic amines with HPLC. The reagent is nonfluorescent, but forms highly fluorescent isoindole upon the reaction with primary amines in alkaline medium. Eleven amine derivatives were baseline separated in 8 min using a gradient elution on a C(8) column and detected with fluorescence detection at lambda(ex)/lambda(em) = 480/546 nm. The detection limits were in the range of 0.5-2 nM (S/N = 3). The proposed method has been successfully applied to the analysis of aliphatic amines in food and environmental samples, including white wine, soybean oil, soil, and tap water with satisfactory recoveries in the range of 94-106%.  相似文献   

10.
A novel fluorescent derivatization reagent for carboxylic acids, 6-oxy-(acetyl ethylenediamine) fluorescein (AEF), was well designed, synthesized, and applied to HPLC. The derivatization reaction with 12 fatty acids, including n-valeric acid (C5), n-hexanoic acid (C6), n-heptanoic acid (C7), n-octanoic acid (C8), n-nonanoic acid (C9), n-decanoic acid (C10), lauric acid (C12), myristic acid (C14), palmitic acid (C16), stearic acid (C18), oleic acid (C18:1), and linoleic acid (C18:2), was completed at 55 degrees C within 40 min. The derivatives of fatty acids were separated on a C18 RP column and detected by fluorescence detection. The LODs attained were 0.4-1.2 nM (S/N of 3). It has been demonstrated that AEF is a prominent derivatization reagent for carboxylic acids which is suitable for HPLC.  相似文献   

11.
Li JS  Wang H  Cao LW  Zhang HS 《Talanta》2006,69(5):1190-1199
A novel fluorescent-activated ester, 8-phenyl-(4-oxy-acetic acid N-hydroxysuccinimidyl ester)-4,4-difluoro-1,3,5,7-tetramethyl-4-bora-3a,4a-diaza-s-indacene (TMPAB-OSu) has been designed and synthesized for amine labeling in HPLC. Being used 11 aliphatic amines as the models, the derivatization conditions were optimized. In 0.2 mol/l borate buffer (pH 8.8), amines reacted with TMPAB-OSu at 30 °C to form the derivatives in 10 min. The fluorescent quantum yield of TMPAB-OSu and its amine derivatives are high even compared with fluorescein. The separation of these amine derivatives was achieved with a C8 column and gradient elution by using 0.1 mol/l sodium acetate buffer (pH 5.0) and methanol. With fluorescence detection at an emission wavelength of 509 nm and an excitation wavelength of 497 nm, the detection limits of aliphatic amines were 2–18 fmol, at a signal-to-noise ratio of 3:1. The proposed TMPAB-OSu-based HPLC method has been applied to the analysis of urine samples of health, hepatic and renal patients and lake water. Recoveries from different matrices are from 96 to 104%, depending on the sample investigated.  相似文献   

12.
A simple and highly sensitive high-performance liquid chromatography (HPLC) for the determination of pipecolic acid (PA) in serum was developed. Pipecolic acid and nipecotic acid (internal standard (IS)) were derivatised with 4-(5,6-dimethoxy-2-phthalimidinyl)-2-methoxyphenylsulfonyl chloride (DMS-Cl) to produce fluorescent sulfonamides. The labelling reaction was carried out at 70 °C for 15 min at pH 9.0. The fluorescent derivatives were separated on a reversed-phase column (45 °C) with a stepwise elution using methanol/acetonitrile/10 mmol l−1 acetic acid (42:5:53) and methanol at a flow rate of 1.0 ml/min and detected at excitation and emission wavelengths of 316 and 403 nm, respectively. The labelling yield was 100.8%. The detection limit of pipecolic acid was 4 fmol at signal-to-noise ratio of 3. The within-day and day-to-day relative standard deviations were 3.3-8.1 and 1.4-6.4%, respectively. The concentration of pipecolic acid in normal human serum was 1.09±0.37 μmol l−1.  相似文献   

13.
A new thiol-reactive derivatizing reagent, 3-iodoacetylaminobenzanthrone (IAB) has been developed for thiol analysis in liquid chromatography. In aqueous methanol containing 15 mM pH 8.3 H3BO3-KCl-Na2CO3 buffer, IAB reacted with thiols at 35 °C for 15 min. The derivatives of IAB with glutathione (GSH), cysteine (Cys), homocysteine (Hcy) and N-acetylcysteine (Nac) were well separated on a C18 column with the mobile phase of methanol-water (50:50, v/v) containing 15 mM pH 2.7 H3cit-Na2HPO4 buffer. At λex/λem=420/540 nm, the detection limits were 20, 20, 55 and 40 fmol (1, 1, 2.3 and 2 nM), respectively, with a signal-to-noise ratio of 3. Owing to the preferential selectivity of iodoacetamidyl moiety to SH group, amino acids, aliphatic amines, phenol and alcohols had no obvious interference with the determination. The proposed method has been applied to the determination of thiols in human blood with recoveries of 98.5-105.3%.  相似文献   

14.
A BODIPY-based fluorescent derivatization reagent with a hydrazine moiety, 1,3,5,7-tetramethyl-8-aminozide-difluoroboradiaza-s-indacene (BODIPY-aminozide), has been designed for aldehyde labeling. An increased fluorescence quantum yield was observed from 0.38 to 0.94 in acetonitrile when it reacted with aldehydes. Twelve aliphatic aldehydes from formaldehyde to lauraldehyde were used to evaluate the analytical potential of this reagent by high performance liquid chromatography (HPLC) on C18 column with fluorescence detection. The derivatization reaction of BODIPY-aminozide with aldehydes proceeded at 60 °C for 30 min to form stable corresponding BODIPY hydrazone derivatives in the presence of phosphoric acid as a catalyst. The maximum excitation (495 nm) and emission (505 nm) wavelengths were almost the same for all the aldehyde derivatives. A baseline separation of all the 12 aliphatic aldehydes (except formaldehyde and acetaldehyde) is achieved in 20 min with acetonitrile–tetrahydrofuran (THF)–water as mobile phase. The detection limits were obtained in the range from 0.43 to 0.69 nM (signal-to-noise = 3), which are better than or comparable with those obtained by the existing methods based on aldehyde labeling. This reagent has been applied to the precolumn derivatization followed with HPLC determination of trace aliphatic aldehydes in human serum samples without complex pretreatment or enrichment method.  相似文献   

15.
Summary Tagging techniques with reagents used for fluorescent detection for short and long-chain fatty acids using high-performance liquid chromatography are evaluated in terms of the tagging reactions, handing, flexibility, stability of the reagents. Emphasis is given to the applications of the tagging techniques to relatively high molecular mass fatty acids. The fatty acids or carboxylic compounds were derivatized to their corresponding esters with 9-(2-hydroxy ethyl)-carbazole (HEC) in acetonitrile at 60°C with N, N′-carbonyldiimidazole (CDI) as a coupling agent in the presence of 4-dimethylaminopyridine (DMAP). A mixture of esters of C1−C20 fatty acids was completely separated with 45 min using gradient elution on a reversed-phase C18 column. The maximum fluorescence emission for the derivatized fatty acids is at 365 nm (λex 293 nm). Studies on derivatization conditions indicated that fatty acids react rapidly and smoothly with HEC in the presence of CDI and DMAP in acetonitrile to give the corresponding sensitively fluorescent derivatives. The application of this method to the analysis of long chain fatty acids in plasma is also investigated. The LC separation shows good selectivity and reproducibility for fatty acids derivatives. The relative standard deviations (n=6) for each fatty acid derivative are <5.0%. The detection limits are at 38–57 fmol levels for C14−C20 fatty acids and lower levels for <C14 fatty acids.  相似文献   

16.
17.
Lippolis V  Pascale M  Maragos CM  Visconti A 《Talanta》2008,74(5):1476-1483
T-2 and HT-2 toxins are Fusarium mycotoxins that can occur in cereals and cereal-based products. Three fluorescent labeling reagents, i.e. 1-naphthoyl chloride (1-NC), 2-naphthoyl chloride (2-NC) and pyrene-1-carbonyl cyanide (PCC), were used for the determination of T-2 and HT-2 toxins by high-performance liquid chromatography (HPLC) with fluorescence detection (FD). Pre-column derivatization of T-2 and HT-2 toxins was carried out under mild conditions (50 °C, 10 min) in toluene with 4-dimethylaminopyridine (DMAP) as catalyst. All fluorescent derivatives were identified and characterized by HPLC-tandem mass spectrometry (HPLC-MS/MS). Optimal stoichiometric ratios (toxin:derivatizing reagent:catalyst), linear range and repeatability of the reaction, stability and sensitivity of the derivatives were determined. A wide linear range (10–1000 ng of either derivatized T-2 or HT-2 toxin), good stability (up to 2 weeks at −20 °C or 5 days at room temperature) of the fluorescent derivatives and good repeatability of the reaction (RSD ≤ 8%) were observed. Detection limits (based on a signal-to-noise ratio of 3:1) were 10.0, 6.3 and 2.0 ng for derivatized T-2 toxin and 6.3, 2.3 and 2.8 ng for derivatized HT-2 toxin with 1-NC, 2-NC and PCC, respectively. In terms of sensitivity and repeatability, PCC and 2-NC reagents showed better performance than 1-anthroylnitrile (1-AN), a previously reported labeling reagent for T-2- and HT-2 toxins. Preliminary studies also showed the applicability of PCC and 2-NC as fluorescent labeling reagents for the simultaneous determination of T-2 and HT-2 toxins in cereal grains by HPLC/FD following immunoaffinity column clean-up.  相似文献   

18.
A sensitive and selective high-performance liquid chromatographic method has been developed and validated for the determination of nateglinide in human plasma. Nateglinide and the internal standard, undecylenic acid, were extracted from plasma by liquid-liquid extraction using a mixture of ethyl acetate-diethyl ether, 50:50 (v/v). Pre-column derivatization reaction was performed using a coumarin-type fluorescent reagent, N-(7-methoxy-4-methyl-2-oxo-2H-6-chromenyl)-2-bromoacetamide. The derivatization proceeded in acetone in the presence of potassium carbonate and catalyzed by 18-crown-6 ether. The fluorescent derivatives were separated under isocratic conditions on a Hypersil BDS-C8 analytical column (250.0 mm × 2.1 mm i.d., particle size 5 μm) with a mobile phase that consisted of 65% acetonitrile in water and pumped at a flow rate of 0.50 mL min−1. The excitation and emission wavelengths were set at 345 and 435 nm, respectively. The assay was linear over a concentration range of 0.05-16.00 μg mL−1 for nateglinide with a limit of quantitation of 0.05 μg mL−1. Quality control samples (0.05, 4.50 and 16.00 μg mL−1) in five replicates from five different runs of analysis demonstrated intra-assay precision (%coefficient of variation <6.8%), inter-assay precision (%coefficient of variation <1.6%) and an overall accuracy (%relative error) less than −3.4%. The method can be used to quantify nateglinide in human plasma covering a variety of pharmacokinetic or bioequivalence studies.  相似文献   

19.
A new and fast hollow fiber based liquid phase microextraction (HF-LPME) method using volatile organic solvents coupled with high-performance liquid chromatography (HPLC) was developed for determination of aromatic amines in the environmental water samples. Analytes including 3-nitroaniline, 3-chloroaniline and 4-bromoaniline were extracted from 6 mL basic aqueous sample solution (donor phase, NaOH 1 mol L−1) into the thin film of organic solvent that surrounded and impregnated the pores of the polypropylene hollow fiber wall (toluene, 20 μL), then back-extracted into the 6 μL acidified aqueous solution (acceptor phase, HCl 0.5 mol L−1) in the lumen of the two-end sealed hollow fiber. After the extraction, 5 μL of the acceptor phase was withdrawn into the syringe and injected directly into the HPLC system for the analysis. The parameters influencing the extraction efficiency including the kind of organic solvent and its volume, composition of donor and acceptor phases and the volume ratio between them, extraction time, stirring rate, salt addition and the effect of the analyte complexation with 18-crown-6 ether were investigated and optimized. Under the optimal conditions (donor phase: 6 mL of 1 mol L−1 NaOH with 10% NaCl; organic phase: 20 μL of toluene; acceptor phase: 6 μL of 0.5 mol L−1 HCl and 600 m mol L−1 18-crown-6 ether; pre-extraction and back-extraction times: 75 s and 10 min, respectively; stirring rate: 800 rpm), the obtained EFs were between 259 and 674, dynamic linear ranges were 0.1-1000 μg L−1 (R > 0.9991), and also the limits of detection were in the range of 0.01-0.1 μg L−1. The proposed procedure worked very well for real environmental water samples with microgram per liter level of the analytes, and good relative recoveries (91-102%) were obtained for the spiked sample solutions.  相似文献   

20.
Summary A fluorescent high-performance liquid chromatography (HPLC) analysis of folic acid (pteroylglutamic acid) and its derivatives using permanganate as a fluorogenic reagent has been developed. In the present work, the various analytical conditions in which the fluorogenic reaction with permanganate could be applied to the HPLC of folic acid in human serum, have been studied. The present method may be employed for the rapid clinical analysis of small amounts of folic acid (150 ppb), without interference from coexisting natural fluorophors; the precision of the present method for folic acid was 6.6% (n=6) (coefficient of variation).Dedicated to Professor Dr. Wilhelm Fresenius on the occasion of his 80th birthdayA part of this paper was presented at the 12th International Symposium on Microchemical Techniques, Cordoba (Spain), September 1992  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号