首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
High performance liquid chromatography (HPLC) with photodiode array (PDA) UV and fluorescence (FL) detection, and capillary electrochromatography (CEC) with laser-induced fluorescence (LIF) detection were investigated for the analysis of acidic extracts derived from illicit methamphetamine. These compounds include major impurities from the hydriodic acid/red phosphorous reduction method, i.e., 1,3-dimethyl-2-phenylnaphthalene and 1-benzyl-3-methylnaphthalene, and other trace-level, structurally related impurities. For certain of these solutes, HPLC with conventional FL detection gave at least a 60× increase in sensitivity over UV detection. In addition, other highly fluorescent impurities were detected in methamphetamine produced via four other synthetic routes. The use of a rapid scanning FL detector (with acquisition of “on the fly” excitation or emission) provided structural information and gave “optimum” excitation and emission detection wavelengths. CEC with LIF detection using UV laser excitation provided greatly improved chromatography over HPLC, with good detection limits in the low ng/ml range. Both methodologies provide good run-to-run repeatability, and have the capability to distinguish between samples.  相似文献   

2.
An automated high-performance liquid chromatographic assay for the determination of an aldosterone antagonist (I) is described using column switching for direct injection of urine samples. After dilution with buffered internal standard solution, the sample was injected onto a clean-up column (17 X 4.6 mm I.D.), dry-packed with C18 reversed-phase material (particle size 30 micron). Polar urine components were removed by flushing the clean-up column with water. Retained substances, including I and the internal standard, were desorbed by backflush elution onto a 5-micron ODS-silica analytical column (125 X 4 mm I.D.), separated with water-methanol-tetrahydrofuran, and detected at 295 nm. After backflushing the analytical column and re-equilibrating the clean-up column, the system was ready for the next injection. The limit of quantification was ca. 100 ng/ml, using a 100-microliter specimen of diluted urine. The mean inter-assay precision of the method up to 25.6 micrograms/ml was 2%. Practicability and accuracy of the new method were demonstrated by the application to excretion studies performed with human volunteers.  相似文献   

3.
A fully automated high-performance liquid chromatographic column-switching system is presented for the determination of cyclosporin A in whole blood. After blood proteins were precipitated with acetonitrile, the supernatant was automatically loaded on to a cyanopropyl column for initial separation, and then the fraction containing cyclosporin A was loaded on to a trimethylsilica column for final separation and quantitation. Cyclosporin A was detected by ultraviolet absorption at 205 nm. The minimum detectable concentration of cyclosporin A was 5 ng/ml in 100 microliter of blood. The coefficient of variation of the method was 1.755, 1.748 and 0.655% in whole blood when spiked at the 170, 425 and 850 ng/ml levels, respectively. One assay was completed in 15 min.  相似文献   

4.
Summary Retention characteristics of metoprolol have been studied in reversed phase mode on RP2, RP8 and CN columns. The plots of retention time as a function of the acetonitrile content and of the ionic strength of the mobile phase permitted the choice of the best conditions to separate metoprolol from plasma components by switching of these three types of columns.Human plasma (0.5–1 ml) diluted with water is first injected on a RP2 column (25–40 m particle diameter, prepared by dry packing) and rinsed with water. The sample is then back eluted with acetonitrile-0.022 M acetate buffer (7525, v:v) and switched to a CN column (10 cm long, 5 m particle diameter). The heart cut of the eluate is selected and loaded on a RP8 analytical column (25 cm long, 5 m particle diameter) with acetonitrile-0.088 M acetate buffer (7525, v:v) as mobile phase.Auto-sampler and switching valves are actuated automatically by a computing integrator based on a fixed time schedule. The duration of one cycle is about 30 min, but the last analytical step is about 15 min and represents the time interval between two injections. Metoprolol, its alpha-hydroxy metabolite and the internal standard are detected by fluorescence (ex= 225 nm; em > 320 nm).Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

5.
The urinary catecholamine metabolites, vanimandelic acid, homovanillic acid, 3,4-dihydroxyphenylacetic acid and 5-hydroxyindoleacetic acid, were extracted on a silica-bonded strong-anion-exchanger cartridge (SAX) and then injected into an high-performance liquid chromatographic (HPLC) system by column switching. Chromatography was performed on a reversed-phase analytical column with electrochemical detection. Full automation was obtained by coupling two devices: a solid-phase automatic sampler and intelligent autosampler. For each substance the recovery was greater than 95% and the coefficient of variation was ca. 3%; the analysis takes 11 min. Substance instability problems are overcome, because the samples are extracted and injected in rapid succession. The normal values and correlation with manual HPLC were established for a large number of samples.  相似文献   

6.
The chromatographic behaviour of ofloxacin on various sorbents, including ODS, C8, C1, nitril, phenyl and tert,-butyl, as stationary phases was investigated and a high-performance liquid chromatography (HPLC) assay was developed for the determination of ofloxacin in serum. The serum samples were directly introduced onto an HPLC column after filtering through a Morcut II membrane filter to remove proteins. The filtrate was concentrated on a pre-column using a phenyl stationary phase and was then introduced to an analytical column with an ODS stationary phase by column switching. Ofloxacin and enoxacin as an internal standard were detected by ultraviolet absorbance at 300 nm. Determination was possible for ofloxacin over the concentration range 50-2000 ng/ml; the limit of detection was 20 ng/ml. The recovery of ofloxacin added to serum was 88.8-101.7% with a coefficient of variation of less than 5.2%. This method is applicable to pharmacokinetic studies of patients after treatment with ofloxacin.  相似文献   

7.
Melagatran is an active thrombin inhibitor showing oral and parenteral bioavailability for antithrombotic therapy. A simple and convenient liquid chromatographic method has been developed and applied to the analysis of melagatran in rabbit plasma. The clean-up and separation of the sample solutions were performed by automated on-line column switching HPLC. The method validation shows the suitability of the column switching liquid chromatographic system for the quantitation of melagatran in biological fluids.  相似文献   

8.
Summary The paper describes the separation of the mixture of alkynaphthalenes from distillation cuts of a pyrolysis oil, by preparative liquid chromatography on silica. The design of the system permits the connection of the columns to form multicolumn systems.The samples were first separated on a single column. The mixtures were further separated using two-column chromatography systems.The obtained fractions were analyzed by capillary gas chromatography. In most cases a substantial increase in the concentrations of the individual components was achieved. In several cases, pure compounds have been obtained. Separation efficiency increases in the following order: single column, two directly coupled collumns, two-step switching chromatography, heartcutting.  相似文献   

9.
Ramoplanin is a novel glycolipodepsipeptide antibiotic, currently undergoing clinical trials. This method describes the determination of ramoplanin by direct injection of human urine into a coupled-column liquid chromatographic system. An internal-surface reversed-phase column has been used for on-line sample clean-up and enrichment. Analytical separation of ramoplanin and MDL 62,456 used as internal standard, has been achieved on a ABZ+ reversed-phase column with ammonium acetate buffer-acetonitrile-methanol according to a gradient profile. Analytes were detected by their UV absorbance at 270 nm. The limit of quantitation was 0.1 microgram/ml urine and the limit of detection was found to be 0.035 microgram/ml, corresponding to 13.7 pmol/ml. Linearity was determined in the range 0.1-2 micrograms/ml. Precision (relative standard deviation) ranged from 0.71 to 8.75% and the accuracy from -9.9 to 11.6%. Different human sources were tested and no interference between analytes and urine constituents was observed. The method is simple and rapid, requiring a total analysis time of 35 min per sample and reaching greater selectivity and accuracy than microbiological assays.  相似文献   

10.
11.
Fast determination of tetrafluoroborate by high-performance liquid chromatography using a silica-based monolithic column and direct conductivity detection was carried out. Chromatographic separation was performed on a Chromolith Speed ROD RP-18e column (50 mm x 4.6 mm i.d.) with tetrabutylammonium hydroxide (TBA-OH)+ phthalic acid as eluent. The effects of eluent concentration, eluent pH, column temperature and flow rate on retention time of tetrafluoroborate were investigated. The optimized chromatographic conditions for determination of tetrafluoroborate were using 0.5mM TBA-OH + 0.31 mM phthalic acid (pH 5.5) as eluent, column temperature of 30 degrees C and flow rate of 6.0 mL/min. Retention time of tetrafluoroborate was less than 1min under the conditions. Common anions (Cl(-), Br(-), NO3(-) and SO4(2-)) did not interfere with the determination of tetrafluoroborate. Detection limit (S/N = 2) for tetrafluoroborate was 1.4 mg/L. The linear range of calibration curve between peak area and the concentration of tetrafluoroborate was from 1.4 to 100.0 mg/L. The reproducibility was 0.09% and 1.8% (n = 5) relative standard deviation (RSD) for retention time and peak area, respectively. The method has been applied to the determination of tetrafluoroborate in ionic liquids. Recoveries of tetrafluoroborate after spiking were 98.2-101.5%.  相似文献   

12.
During method development for the determination of either isotretinoin, tretinoin and their 4-oxo-metabolites, or etretinate, acitretin and 13-cis-acitretin in plasma using high-performance liquid chromatography and column switching, recovery problems arose, when undiluted plasma samples were injected directly onto the precolumn. These recovery problems may be due to the strong binding of the retinoids to different plasma proteins. Measures to overcome this strong protein binding, such as variation of the injection solution composition and the purge mobile phase, were systematically investigated. Best recoveries were obtained by diluting of plasma with 9 mM sodium hydroxide-acetonitrile (8:2, v/v) and protein precipitation with ethanol for the isotretinoin and etretinate series, respectively, in combination with the use of a purge mobile phase containing ammonium acetate and 10-20% acetonitrile. Less effective was the use of a longer precolumn or heating of the precolumn.  相似文献   

13.
Analytical procedures have been investigated for the separation, detection, identification and quantitation of some metabolites of N-benzyl-4-substituted anilines. Techniques based on gas-liquid chromatography were investigated and found to be unsatisfactory. By the use of reversed-phase high-performance liquid chromatography with gradient and ion-pairing techniques, methods were devised for the simultaneous analyses of a variety of metabolites. The method involves minimum sample work-up (acetonitrile precipitation) and allows easy and prompt analysis in biological media avoiding undue decomposition of unstable metabolites.  相似文献   

14.
An impurity-profiling method for 3,4-methylenedioxymethamphetamine (MDMA) is presented. The impurities of interest were extracted by solid-phase extraction (SPE) on Bakerbond C18 spe columns from a weakly alkaline solution (pH 8.5). Development of the extraction conditions covered selection of the buffer for dissolution of the sample and the volume of the eluent used to elute the impurities. An important part of the studies was to optimise the separation conditions, and the simplex method was used for this purpose. Cluster analysis was applied for comparison of samples and its grouping. The developed method was based on the areas of 33 selected peaks corresponding to MDMA impurities. All examined samples were correctly classified into clusters corresponding to the synthetic route.   相似文献   

15.
Summary Glass capillary gas chromatographic methods for profile analysis of trace impurities of illicit heroin samples have been developed. The procedure consists of extracting the impurities by toluene from acidic solution and examination by capillary GC. Derivatized and nonderivatized extracts of illicit heroin from different sources are reported. The reproducibility of the procedure and the detection with FID and N-FID are studied. Results obtained by application of the profiling procedure, as an additional pattern for comparison of samples in forensic casework, have shown the distinct advantage of this method.Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

16.
Minor impurities in the antibacterial agent temafloxacin hydrochloride were determined using high-performance liquid chromatography. Manufacturing impurities and degradation products were separated using a reversed-phase system with gradient elution. Detector response was linear for the individual impurities to approximately 50 micrograms/ml which represents 2.5% of the drug concentration. The procedure provides quantitation of impurities to approximately the 0.05% level with precision (relative standard deviations) of 4.7% to 29% in typical bulk drug lots. A variety of reversed-phase columns were evaluated for the assay method with optimum resolution achieved using a 5-microns Nucleosil C18 packing.  相似文献   

17.
A polyacrylamide gel crosslinked with allyl-β-cyclodextrin can be used repeatedly for several weeks for the separation of DNA fragments, since bubbles are not generated during a run. Allyl-β-cyclodextrin can easily be synthesized in one step from allylglycidylether and β-cyclodextrin. The plate numbers for DNA fragments, up to about 1500 bp, are high: for the separation of pBR322/HaeIII fragments they were in the range 450 000–1 600 000 m−1. The resolution was almost independent of the concentration of the crosslinker (allyl-β-cyclodextrin) — in sharp contrast to gels crosslinked with N,N′-methylenebisacrylamide.  相似文献   

18.
The automated determination of amifloxacin and two of its principal metabolites in human plasma and urine by column-switching high-performance liquid chromatography is described. Plasma or urine samples, diluted 1:1 with 0.5 M sodium citrate buffer pH 2.5, were directly injected onto a cation-exchange pre-column. Following a 2.0-min wash of the pre-column with water at a flow-rate of 1.1 ml/min, the effluent from the pre-column was directed to the analytical column by a column-switching device. The precision of the plasma and urine methods ranged from a +/- 1.9 to +/- 3.6% for all compounds. The accuracies of the methods were within a range of -3.3% to 6.4% of the nominal values for all compounds. Linear responses were observed for all the standards in the range 0.10-5.0 micrograms/ml for plasma and 0.50-100 micrograms/ml for urine for all three compounds. The minimum quantifiable levels were 0.10 and 0.50 micrograms/ml for plasma and urine, respectively. The analytical methods may be used to quantify amifloxacin and the piperazinyl-N-desmethyl and piperazinyl-N-oxide metabolites in plasma and urine samples obtained from humans, monkeys, dogs and rats.  相似文献   

19.
A relatively simple and cost-effective method utilizing HPLC with UV detection was developed to detect and quantify hydrazine in sludge samples. The method was developed primarily for sludge samples, but it can also be applicable to soil and other environmental samples. The hydrazines in the matrices were derivatized to hydrazones with benzaldehyde. The hydrazones were separated using HPLC with an RP C-18 column in an isocratic mode with methanol-water (95:5 v/v) and detected with UV detection at 313 nm. The detection limit (25 microL injection) for the method is 0.02 microg/mL of hydrazine.  相似文献   

20.
An accurate and precise RP-HPLC method was developed and validated for the determination of carbamazepine and its impurities iminostilbene and iminodibenzyl in a tablet formulation with fluphenazine as an internal standard. Buffer-methanol (50 + 50, v/v) was used as the mobile phase. During validation, specificity, linearity, precision, accuracy, LOD, LOQ, and robustness of the method were tested. The method was proven to be specific against placebo interference. Linearity was evaluated over the concentration range of 100-500, 0.05-0.25, and 0.1-0.5 microg/mL, and the r values were 0.9994, 0.9997, and 0.9979 for carbamazepine, iminostilbene, and iminodibenzyl, respectively. Intraday precision of the method was good, and RSD was below 2% for all analytes. The accuracy of the method ranged from 100.69 to 102.10, 99.76 to 102.66, and 99.26 to 100.08% for carbamazepine, iminostilbene, and iminodibenzyl, respectively. LOD was 0.0125, 0.025, and 0.05 microg/mL and LOQ was 0.05, 0.05, and 0.1 microg/mL for carbamazepine, iminostilbene, and iminodibenzyl, respectiviely. Robustness of the method was proven by using a chemometric approach. The method was successfully applied to the analysis of commercially available carbamazepine tablets and showed good repeatability, with RSD below 2%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号