1.
A two-step methodology has been developed for the prediction of protein retention time in linear-gradient HIC systems. Isocratic retention parameters were determined from ln(k')-salt concentration plots for a number of commercially available proteins with a range of properties. Quantitative structure property relationship (QSPR) models based on a support vector machine (SVM) approach were generated for predicting isocratic retention parameters for proteins not included in the model generation. The predicted parameters were then used to calculate protein gradient retention times and the results indicate that this approach is well suited for predicting experimental gradient retention data. The approach presented in this paper may have implications for HIC methods development at both the bench and process scales.  相似文献   

2.
3.
Alcohols were derivatised to their carbazole-9-N-acetic acid (CRA) esters with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDC.HCl) as the dehydrating agent. Studies on derivatisation conditions indicated that the coupling reaction proceeded rapidly and smoothly in the presence of a base catalyst in acetonitrile to give the corresponding sensitively fluorescent derivatives. The retention behaviour of alcohol derivatives was investigated by varying mobile phase compositions (ACN-water and MeOH-water). The parameters from the equation log k'=A-BX were evaluated by retention data of derivatives using an isocratic elution with different mobile phases. The results indicated that the parameters derived allowed computation of retention factors in good agreement with experiments. At the same time, a general equation was derived that makes possible predictions of partition coefficient in binary mobile phases with different proportions of organic solvent to water based on some simple regression analysis. The LC separation for the derivatised alcohols containing higher carbon alcohols showed good reproducibility on a reversed-phase C18 column with gradient elution. The detection limits (excitation at 335 nm, emission at 360 nm) for derivatised alcohols (signal-to-noise ratio=3:1) were in the range of 0.1-0.4 pg per injection.  相似文献   

4.
The isocratic and gradient elution behaviour of beta-endorphin and glucagon, two polypeptides known to exist in amphipathic alpha-helical conformations in lipophilic environments, have been examined under reversed-phase high-performance liquid chromatographic (RP-HPLC) conditions with low pH, aquo-acetonitrile mobile phases. The effects of changes in the volume fraction, psi, of the organic solvent modifier and temperature, T, on the magnitudes of the S and log k(o) values of these two polypeptides, obtained from the plots of logarithmic capacity factor (log k') vs. psi using isocratic elution conditions have been determined. These data have then been compared to the corresponding S and log k(o) values, obtained from the plots of logarithmic median capacity factor (log k) versus the median volume fraction of the organic solvent modifier (psi) derived from the linear gradient elution data, using the same n-butyl silica sorbent and related aquo-acetonitrile mobile phase conditions. As apparent from these studies, substantial differences occur in the temperature-dependent trends and magnitudes of the corresponding S and S values, or the log k(o) and log k(o) values, when these parameters are derived from experimental data acquired by these two different elution methods. Moreover, when gradient elution data for beta-endorphin and glucagon are utilised, the extrapolated values of the intercept and slope of the plots of log k vs. 1/T (corresponding to an apparent change in the median enthalpy of association, deltaH(o)assoc, or an apparent change in the median entropy of association, deltaS(o)assoc) substantially deviated from the values obtained for the thermodynamic parameters, deltaH(o)assoc and deltaS(o)assoc, derived from the log k' vs. 1/T plots using the corresponding isocratic data. These findings thus have important implications for biophysical and thermodynamic investigations when gradient elution data are employed to assess the molecular basis of the interaction of polypeptides with non-polar ligates.  相似文献   

5.
Chromatographers are cautioned to avoid gradient elution when isocratic elution will do. In this work, we compared the analytical properties of gradient and isocratic separations of a sample which can be done quite readily under isocratic conditions. We found that gradient elution gave a shorter overall analysis with similar resolution of the critical pair compared to isocratic elution without sacrificing repeatability in retention time, peak area and peak height or linearity of the calibration curve. We also obtained acceptable repeatability in peak area/height and linearity of calibrations curves for a sample that required gradient elution using a practical baseline subtraction technique. Based on these results and related work which show that columns can be reequilibrated by flushing with less than two column volumes of the initial eluent, we conclude that many of the reasons given to avoid gradient elution deserve serious reconsideration, especially for those samples which are easily separated isocratically. However, we believe isocratic elution will remain preferable when: (1) the sample contains less than 10 weakly retained components (i.e. the last peak elutes with k' < 5) or (2) the gradient baseline impedes trace analysis.  相似文献   

6.
Several procedures are available for simulating and optimising separations in ion chromatography (IC), based on the application of retention models to an extensive database of analyte retention times on a wide range of columns. These procedures are subject to errors arising from batch-to-batch variability in the synthesis of stationary phases, or when using a column having a different diameter to that used when the database was acquired originally. Approaches are described in which the retention database can be recalibrated to accommodate changes in the stationary phase (ion-exchange selectivity coefficient and ion-exchange capacity) or in the column diameter which lead to changes in phase ratio. The entire database can be recalibrated for all analytes on a particular column by performing three isocratic separations with two analyte ions. The retention data so obtained are then used to derive a "porting" equation which is employed to generate the required simulated separation. Accurate prediction of retention times is demonstrated for both anions and cations on 2mm and 0.4mm diameter columns under elution conditions which consist of up to five sequential isocratic or linear gradient elution steps. The proposed approach gives average errors in retention time prediction of less than 3% and the correlation coefficient was 0.9849 between predicted and observed retention times for 344 data points comprising 33 anionic or cationic analytes, 5 column internal diameters and 8 complex elution profiles.  相似文献   

7.
8.
Isocratic hydrophobic interaction chromatography of five proteins has been carried out using mobile phases containing the surfactant 3-(3-cholamidopropyl)-dimethylammoniopropane sulfonate (CHAPS). Linear relationships were found between log k' and ammonium sulfate concentrations for all the proteins with CHAPS in the submicellar concentration range. The slope of such a plot decreases monotonically as CHAPS concentration is increased. To a first approximation, the effect of CHAPS on protein retention can be explained in terms of a competitive binding model. However, CHAPS does show differential effects on the elution of proteins, substantially altering selectivity. The use of a normalized capacity factor, k'/k'o, proves useful for comparing retention times of different proteins as a function of CHAPS concentration. The magnitudes of k'/k'o were found to be inversely correlated with the slopes of plots of log k' vs. ammonium sulfate concentration in the absence of CHAPS. Adsorption isotherms for CHAPS were determined over the working range of ammonium sulfate. The binding of CHAPS to the SynChropak Propyl stationary phase and its effects on retention were found to be readily reversible. For each protein, plots of k'/k'o vs. surface concentration of CHAPS were superposable for data obtained at different salt concentrations. These findings support a competitive binding model. A simple geometric argument for stationary phase occupancy provides a qualitative explanation for the observed surfactant selectivity.  相似文献   

9.
This paper describes the results of the evaluation of retention dependence on the physicochemical properties of solutes in linear gradient elution by reversed-phase liquid chromatography (RPLC) based on linear solvation energy relationships (LSERs). Retention time data on Inertsil ODS(3) column by linear gradient elution were collected for both acetonitrile-water and methanol-water binary mobile phases under various gradient steepness. Based on the LSERs, the retention times were linearly correlated with the physicochemical properties (size, dipolarity, and hydrogen bond donor-acceptor acidity and basicity) of solutes. As predicted by LSERs, very acceptable linear relationships are observed for both mobile phases. While the magnitudes of the coefficients are modified by the gradient steepness, their signs are consistent with those obtained by isocratic elution. As obtained for isocratic elution, the dominant factors to retention in linear gradient elution of RPLC are the solutes' size and hydrogen bond acceptor basicity. The conclusions of the study allow us to predict retention in chromatographic method development by gradient elution.  相似文献   

10.
The anion-exchange elution behaviour of alpha-lactalbumin was studied on cross-linked and quaternized polyvinylimidazole, deposited on various high-performance liquid chromatographic supports (porous silica and diol silica). The influence of the nature and thickness of the coating layer on the retention and band-width properties of the protein elution peak was examined by isocratic elution. The retention properties of alpha-lactalbumin were studied from the plot of log k' vs. log([NaCl]), where k' is the capacity factor and [NaCl] the displacer salt concentration in the aqueous phase. The retention depends on the amount of stationary phase deposited on the support, but an increased hydrophobic effect is found when the polymer films do not coat the chromatographic support uniformly. Band broadening of the elution peaks was studied in terms of plots of plate height vs. mobile phase velocity. An important mass-transfer contribution is found, which decreases with increasing k' and increases with the thickness of the coating layer. These effects reveal that the diffusion into the polymer layer is the controlling step of the ion-exchange process with non-uniform polymer layers of large mean thickness.  相似文献   

11.
One- and multi-variable retention models proposed for isocratic and/or gradient elution in reversed-phase liquid chromatography are critically reviewed. The thermodynamic, exo-thermodynamic or empirical arguments adopted for their derivation are presented and discussed. Their connection to the retention mechanism is also indicated and the assumptions and approximations involved in their derivation are stressed. Special attention is devoted to the fitting performance of the various models and its impact on the final predicted error between experimental and calculated retention times. The possibility of using exo-thermodynamic retention models for prediction under gradient elution is considered from a practical point of view. Finally, the use of statistical weights in the fitting procedure of a retention model and its effect on the calculated elution times as well as the transferability of retention data among isocratic and gradient elution modes are also examined and discussed.  相似文献   

12.
Summary A method of reserved-phase HPLC analysis for mixtures of triglycerides (TG's) that provides good resolution at acceptable analysis times for high-ECN TG's has been developed. An elution gradient of methyltert-butyl-ether (MTBE) in acetonitrile (ACN) was used with an ultraviolet detector operated at 215nm. The effect of the proportion of MTBE in the mobile phase, gradient time, temperature and sample solvent on TG retention and resolution was studied. Linear relationships were derived between the logarithm of the capacity factor (log k'), and the logarithm of selectivity (log α) and the above-mentioned chromatographic factors. The conditions selected were: an elution gradient of from 23 to 30% MTBE, an elution gradient time of 25 minutes, and a temperature of 30°C, which provided good resolution of soybean oil TG's in less than 30 minutes.  相似文献   

13.
14.
Monodisperse poly(glycidyl methacrylate-divinylbenzene) microspheres were functionalized with propyl sulfonic acid moieties to obtain beads negatively charged in a wide pH range. They were packed into fused-silica capillary of 50 micro, I.D. in order to separate proteins by capillary electrochromatography (CEC). Baseline separation of four basic proteins as well as three cytochrome c variants with an average column efficiency of 60,000 theoretical plates was obtained under isocratic elution conditions. The high efficiency is attributed to the uniformity of the column packing and the hydrophilic surface coverage of the polymer beads derived from the functionalization process. The effect of pH and salt concentration on protein separations was investigated and the results showed that the CEC separation mechanism is the combination of chromatographic retention and electrophoretic migration. Moreover, the column packed with the strongly acidic poly(glycidyl methacrylate-divinylbenzene) beads was also suitable for protein separations by micro-HPLC with a salt gradient. The comparison between the two kinds of elution modes shows that the column described here exhibited higher peak efficiency with isocratic elution in CEC than with gradient elution in micro-HPLC.  相似文献   

15.
The applicability and predictive properties of the linear solvent strength model and two nonlinear retention‐time models, i.e., the quadratic model and the Neue model, were assessed for the separation of small molecules (phenol derivatives), peptides, and intact proteins. Retention‐time measurements were conducted in isocratic mode and gradient mode applying different gradient times and elution‐strength combinations. The quadratic model provided the most accurate retention‐factor predictions for small molecules (average absolute prediction error of 1.5%) and peptides separations (with a prediction error of 2.3%). An advantage of the Neue model is that it can provide accurate predictions based on only three gradient scouting runs, making tedious isocratic retention‐time measurements obsolete. For peptides, the use of gradient scouting runs in combination with the Neue model resulted in better prediction errors (<2.2%) compared to the use of isocratic runs. The applicability of the quadratic model is limited due to a complex combination of error and exponential functions. For protein separations, only a small elution window could be applied, which is due to the strong effect of the content of organic modifier on retention. Hence, the linear retention‐time behavior of intact proteins is well described by the linear solvent strength model. Prediction errors using gradient scouting runs were significantly lower (2.2%) than when using isocratic scouting runs (3.2%).  相似文献   

16.
pISep is a major new advance in low ionic strength ion exchange chromatography. It enables the formation of externally controlled pH gradients over the very broad pH range from 2 to 12. The gradients can be generated on either cationic or anionic exchangers over arbitrary pH ranges wherein the stationary phases remain totally charged. Associated pISep software makes possible the calculation of either linear, nonlinear or combined, multi-step, multi-slope pH gradients. These highly reproducible pH gradients, while separating proteins and glycoproteins in the order of their electrophoretic pIs, provide superior chromatographic resolution compared to salt. This paper also presents a statistical mechanical model for protein binding to ion exchange stationary phases enhancing the electrostatic interaction theory for the general dependence of retention factor k, on both salt and pH simultaneously. It is shown that the retention factors computed from short time isocratic salt elution data of a model protein can be used to accurately predict its salt elution concentration in varying slope salt elution gradients formed at varying isocratic pH as well as the pH at which it will be eluted from an anionic exchange column by a pISep pH gradient in the absence of salt.  相似文献   

17.
18.
Previous studies of peptide separation by normal-phase liquid chromatography have shown a linear relationship between the logarithm of the capacity factor and the logarithm of the volume fraction of modifier in the mobile phase. This permitted the use of a model to predict isocratic and gradient retention times based on data obtained by two initial gradient runs. In the present study, chromatographic behavior of 25 peptides in normal-phase liquid chromatography with isocratic elution have been studied and a linear relationship between the slope (S) and intercept [log k(0)] was obtained. This relationship was combined with the algorithm of prediction reported in the previous paper. The prediction of peptide retention times with only a single experimental gradient retention data was investigated.  相似文献   

19.
Summary The paper describes by simple experiments in a pragmatical way by easy rules of thumbs gradient optimization. Besides selection of the stationary phase and initial and final conditions the two other important variables are program time and eluent flow rate. It is demonstrated, that when the product of both, the gradient volume, is kept constant, the solutes are always eluted with the same eluent composition at column outlet. At constant gradient volume, peak broadening depends on flow rate and on the eluent properties (viscosity) at which the solutes elute, and on the time the solutes spend in the column. Because peak broadening increases with increasing gradient volume, the peak capacity in gradient elution shows an optimum at gradient volumes around 15 empty column volumes (program times 45 to 60 min at flow rates of 1 ml/min with standard columns).Gradient elution can also be used for fast evaluation of optimum eluent composition for isocratic analysis. This procedure requires a calibration of the equipment for determination of eluent composition at column outlet. The sample is chromatographed in a standard gradient run of 10 to 15 empty column volumes. The eluent composition at which the solute of interest elutes during the gradient is used for isocratic analysis, where the k' value of this solute will then be around 2.Part of Ph. D. Thesis H. Elgass, Saarbrücken, 1978, present address Hewlett-Packard, Waldbronn, FRG. In part presented at Eastern Analytical Symposium, New York, 1982.  相似文献   

20.
The effects of urea on the high-performance cation-exchange chromatography of hen egg lysozyme are reported. The capacity factor, k', has been determined as a function of cation concentration with a polyaspartate column using the acetates of Na+, K+, Ca2+ and Mg2+. Urea decreases lysozyme retention. Plots of log k' vs. log ionic strength show linear relationships. The slope of the plot describing the Ca2+ elution of lysozyme was the same in the presence of 5 M urea as in its absence. In strong urea solutions and at elevated temperatures, lysozyme denaturation is evidenced by a marked decrease in k'. The temperature range for denaturation corresponded closely to that observed in intrinsic fluorescence and circular dichroism measurements. The potential utility and limitations of high-performance ion-exchange chromatography for studying protein denaturation are discussed.  相似文献   