首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A robust CE method for the simultaneous determination of the enantiomers of ketamine and norketamine in equine plasma is described. It is based upon liquid-liquid extraction of ketamine and norketamine at alkaline pH from 1 mL plasma followed by analysis of the reconstituted extract by CE in the presence of a pH 2.5 Tris-phosphate buffer containing 10 mg/mL highly sulfated beta-CD as chiral selector. Enantiomer plasma levels between 0.04 and 2.5 microg/mL are shown to provide linear calibration graphs. Intraday and interday precisions evaluated from peak area ratios (n = 5) at the lowest calibrator concentration are < 8 and < 14%, respectively. The LOD for all enantiomers is 0.01 microg/mL. After i.v. bolus administration of 2.2 mg/kg racemic ketamine, the assay is demonstrated to provide reliable data for plasma samples of ponies under isoflurane anesthesia, of ponies premedicated with xylazine, and of one horse that received romifidine, L-methadone, guaifenisine, and isoflurane. In animals not premedicated with xylazine, the ketamine N-demethylation is demonstrated to be enantioselective. The concentrations of the two ketamine enantiomers in plasma are equal whereas S-norketamine is found in a larger amount than R-norketamine. In the group receiving xylazine, data obtained do not reveal this stereoselectivity.  相似文献   

2.
The analysis is described for separating seven beta-adrenergic blocking agents (atenolol, celiprolol, clorprenaline, fenoterol, metoprolol, propranolol, terbutaline) and clenbuterol (sympathomimetic beta-2 receptor stimulating agonist, decongestant and bronchodilator, illicit anabolic used in athletics) by CE with UV detection. In order to simultaneously separate all analytes, Tris-H3PO4 solution was applied containing titanium dioxide nanoparticles (TiO2 NPs) as BGEs. The effects of important factors, such as concentration of TiO2 NPs, optimum pH, run buffer concentration, and separation voltage, were investigated so as to achieve best CE separation. The eight analytes could be well separated applying a separation voltage of 15 kV in 75 mM Tris-H3PO4 buffer at a pH of 2.40, containing 6.0 x 10(-6) g/mL TiO2 NPs. Under these optimal conditions, the RSDs for peak areas and for migration times were less than 2.7 and 2.3%, respectively. The detection limits were 0.1 microg/mL for celiprolol, 0.1 microg/mL for propranolol, 0.2 microg/mL for fenoterol, 1.0 microg/mL for atenolol, 1.0 microg/mL for clenbuterol, 1.0 microg/mL for clorprenaline, 1.0 microg/mL for metoprolol, and 1.0 microg/mL for terbutaline. The proposed method was successfully applied for the rapid CE determination of the frequently applied antihypertensive beta-blocking compounds atenolol, metoprolol, terbutaline, and propranolol in pharmaceutical tablets.  相似文献   

3.
Mycophenolate mofetil (MMF) is a widely used drug for the maintenance of immunosuppressive therapy in renal-transplant recipients. MMF is rapidly metabolized in vivo to mycophenolic acid (MPA), a reversible, noncompetitive inhibitor of inosine monophosphate dehydrogenase, which represents a limiting enzyme in lymphocyte proliferation. MPA shows large interindividual pharmacokinetic variability: its monitoring is therefore of primary importance to achieve adequate immunosuppression with minimized risk of graft rejection or toxicity. We developed a CE method for the determination of total MPA (tMPA) in plasma, based on easy sample preparation; CE evaluation of tMPA was performed in 30 mmol/L sodium-borate with 10 mmol/L SDS (pH 10.00) at 25 degrees C using a 60 cm (54.5 to window) uncoated capillary with UV detection at 254 nm wavelength. MPA was readily detectable in plasma; the CE method was linear in the range of 0.7-120 microg/mL (r >0.992). Intra- and interassay imprecision was <7% except for the lowest spiked MPA concentration, which had an intra-assay RSD% of 14.7 compared to 18.3 interassay. Data by CE were compared with results obtained by a validated HPLC method. CE assay of tMPA exhibited a very good correlation (r(2) >0.988) with respect to HPLC; Bland-Altman difference versus average showed a mean of -0.18 microg/mL +/- 1.14 SD. CE determination of tMPA is a robust, sensitive and reproducible method with the advantage over HPLC of being fast, simple and unexpensive, also enabling quick assessment of MPA for pharmacokinetic studies.  相似文献   

4.
A high-performance liquid chromatography (HPLC) method with tandem mass spectrometric detection is described for the determination of paroxetine, an antidepressant drug, and its metabolite (3S,4R)-4-(4-fluorophenyl)-3-(4-hydroxy-3-methoxyphenoxymethyl)piperidine (HM paroxetine) in human plasma. Plasma samples were hydrolysed with hydrochloric acid and then analytes were extracted with ethyl acetate at alkaline pH. Extracts were analysed by HPLC coupled to an atmospheric pressure ionisation-electrospray (ESI) interface and an ion trap mass spectrometer. Chromatography was performed on a reversed-phase column using acetonitrile/0.02% formic acid (66:34, v/v) as a mobile phase. The mass spectrometer was operated in the multiple reaction monitoring mode. The method was validated over concentration ranges of 0.75-100 microg/L and 5-100 microg/L for paroxetine and HM paroxetine, respectively. Mean recoveries of 77% for paroxetine and 76% for HM paroxetine were found, with precision always better than 15%. The limits of detection and quantification were 0.20 and 0.70 microg/L for paroxetine, and 0.70 and 2.20 microg/L for its metabolite. The method was applied to the analysis of plasma samples obtained from nine healthy male volunteers administered with a single oral dose of 20 mg paroxetine. After the 20-mg dose, the mean peak plasma concentration was 8.60 microg/L for paroxetine and 92.40 microg/L for HM paroxetine showing a tenfold ratio between the metabolite and the parent drug along the entire time-concentration curve.  相似文献   

5.
A method was validated for the determination of the 2 main components of bee venom, phospholipase A2 and melittin, by capillary electrophesis (CE). Optimum resolution and selectivity were attained with a running electrolyte of 150 mM phosphoric acid, pH 1.8. The repeatability and day-to-day reproducibility of the migration times were better than 0.36 and 2.8%, respectively. The repeatability and day-to-day reproducibility of the normalized peak areas were better than 1.3 and 2.6%, respectively. The response of the UV detector at 190 nm was linear over < 2 concentration decades, from 0.05 to 1.5 mg/mL, with correlation coefficients of 0.9994 for phospholipase A2 and 0.9997 for melittin. The limits of detection and quantitation were 4.5 and 15 microg/mL, respectively, for phospholipase A2 and 1.6 and 6 microg/mL, respectively, for melittin. The reproducibility of the measurements with 2 different CE instruments was satisfactory; the mean concentration and relative standard deviation (RSD) values for phospholipase A2 and melittin were 14.4% (RSD, 1.3%) and 51.4% (RSD, 1.1%), respectively, with instrument I; the corresponding values with instrument II were 14.5% (RSD, 2.8%) and 52.3% (RSD, 2.2%). The accuracy was estimated by comparison with a liquid chromatographic (LC) method. Differences between the CE and LC measurements were attributed to irreversible adsorption of the analytes on the LC column. The recoveries of phospholipase A2 and melittin with the CE method were 98.8 and 101.7%, respectively.  相似文献   

6.
S M Wu  Y H Ho  H L Wu  S H Chen  H S Ko 《Electrophoresis》2001,22(13):2717-2722
In this study, low concentrations of histamine2-receptor (H2-)antagonists were effected across a water plug, with separation taking place in a binary buffer comprising ethylene glycol and NaH2PO4 (pH 5.0), and detection at 214 nm. Liquid-liquid extraction with ethyl acetate- isopropanol is shown to provide extracts that are sufficiently clean. The calibration curves were linear over a concentration range of 0.1-2.00 microg/mL cimetidine, 0.2-5.0 microg/mL ranitidine-HCl, 0.3-5.0 microg/mL nizatidine, and 0.1-3.0 microg/mL famotidine. Mean recoveries were > 82%, while the intra- and interday relative standard deviations (RSDs) and relative errors (REs) were all < 13%. The method is sensitive with a detection limit of 3 ng/mL cimetidine, 30 ng/mL ranitidine HCl, 50 ng/mL nizatidine and 10 ng/mL famotidine (S/N = 3, electric-driven injection 90 s). This newly developed capillary electrophoresis (CE) method was applied for the determination of analytes extracted from plasma taken from a volunteer dosing a cimetidine, ranitidine, and nizatidine tablet simultaneously. These three H2-antagonists can be detected in real samples by this method, excluding the low dosing of famotidine tablet.  相似文献   

7.
A new, simple, and reproducible method for determination of carboxylic acid metabolite of clopidogrel in human plasma has been developed. After liquid-liquid extraction in acidic medium with chloroform, samples were quantified on a Nova-pak C(8), 5 microm column using a mixture of 30 mM K(2)HPO(4)-THF-acetonitrile (pH = 3, 79:2:19, v/v/v) as mobile phase with UV detection at 220 nm. The flow rate was set at 0.9 mL/min. Ticlopidine was used as internal standard and the total run time of analysis was about 12 min. The method was linear over the range of 0.2-10 microg/mL of clopidogrel metabolite in plasma (r(2) > 0.999). The within-day and between-day precision values were in the range 1.0-4.8%. The limit of quantification of the method was 0.2 microg/mL. The method was successfully used to study the pharmacokinetics of clopidogrel in healthy volunteers.  相似文献   

8.
Qi L  Liu M  Guo Z  Xie M  Qiu C  Chen Y 《Electrophoresis》2007,28(22):4150-4155
The aim of this work was to assay seasoning D- or L-aromatic amino acids (AAs) in rice-brewed suspensions, Laozao in Chinese, by chiral ligand-exchange CE with UV detection and Zn(II) complex as a chiral selecting system. Resolution and peak retention were found to be parallel to the basicity of the AA chiral ligands, and basic L-Arg was known to work the best at pH 8.20 compared with L-Lys and other AA ligands. Baseline separation of DL-aromatic AAs and partially separation of some FMOC-labeled nonaromatic AAs have been achieved using a running buffer of 5 mM ammonium acetate, 100 mM boric acid, 3 mM ZnSO(4), and 6 mM L-Arg at pH 8.20. The aromatic amino acids in four brands of Laozao were measured in a range of 0.25-20 microg/mL for Typ, 1.00-120 microg/mL for Phe, and 2.50-200 microg/mL for Tyr, with linear regression coefficient all over 0.999. The LOD (S/N=3) was 0.15 microg/mL for Typ, 0.50 microg/mL for Phe, and 1.25 microg/mL for Tyr. The recovery of the method determined by spiking with the supernates of Laozao as background was 94.0-112.9%. The RSDs of migration time and peak area measured from six injections of tyrosine were 0.2 and 2.7%, respectively, for run-to-run, and 1.6 and 3.2%, respectively for day-to-day. Interestingly, there were only L-Trp, D-Tyr, and L-Tyr found in the assayed four brands of Laozao. They may serve as an index to recognize the brand of Laozao.  相似文献   

9.
A method for the determination of cyclamate in food was developed using solid-phase extraction (SPE) and capillary electrophoresis (CE) with indirect ultraviolet (UV) detection. A 5-10 g sample in 0.1 mol/L hydrochloric acid was homogenized and made up to a volume of 50 mL with 0.1 mol/L hydrochloric acid. After the sample was centrifuged, 25 mL of supernatant was loaded into an Oasis HLB SPE cartridge. The cartridge was washed with 2 mL of demineralized water followed by 2 mL of 50% aqueous methanol, and cyclamate was eluted with 4.5 mL of 50% aqueous methanol. The eluate was added to a solution of sodium propionate (internal standard) for CE analysis. The cyclamate in the eluate was electrophoresed on a fused-silica capillary using 1 mmol/L hexadecyltrimethylammonium bromide and 10 mmol/L potassium sorbate as a running buffer. Detection and reference wavelengths of cyclamate determined with a UV detector were 300 and 254 nm, respectively. The calibration curves for cyclamate showed good linearity in the range of 2-1000 microg/mL and the limits of detection in beverage, fruit in syrup, jam, pickles and confectionary are sample dependent and ranged from 5-10 microg/g. The recovery of cyclamate added at a level of 200 microg/g to various kinds of foods was 93.3-108.3% and the relative standard deviation was less than 4.9% (n=3). A number of commercial samples were analyzed using the proposed method. Cyclamate was detected in one waume, two pickles, and two sunflower seeds. The quantitative values determined with CE correlated to those from high-performance liquid chromatography (HPLC) (the detected values of cyclamate in a sunflower seed measured by CE and HPLC were 3.40 g/kg and 3.51 g/kg, respectively). This analytical method for cyclamate using CE is especially suitable for use in the field.  相似文献   

10.
An enantioselective assay for the determination of methadone and its main metabolite 2‐ethylidene‐1,5‐dimethyl‐3,3‐diphenylpyrrolidine in equine plasma based on capillary electrophoresis with highly sulfated γ‐cyclodextrin as chiral selector and electrokinetic analyte injection is described. The assay is based on liquid/liquid extraction of the analytes at alkaline pH from 0.1 mL plasma followed by electrokinetic sample injection of the analytes from the extract across a buffer plug without chiral selector. Separation occurs cationically at normal polarity in a pH 3 phosphate buffer containing 0.16% (w/v) of highly sulfated γ‐cyclodextrin. The developed assay is precise (intra‐ and interday RSD < 4% and < 7%, respectively), is capable to determine enantiomer levels of methadone and 2‐ethylidene‐1,5‐dimethyl‐3,3‐diphenylpyrrolidine in plasma down to 2.5 ng/mL, and was successfully applied to monitor enantiomer drug and metabolite levels in plasma of a pony that was anesthetized with racemic ketamine and isoflurane and received a bolus of racemic methadone and a bolus followed by constant rate infusion of racemic methadone. The data suggest that the assay is well suited for pharmacokinetic purposes.  相似文献   

11.
This paper reports the development of a rapid method for the enantioselective analysis of the nonsteroidal anti-inflammatory drug ibuprofen in human plasma by capillary electrophoresis employing the anionic cyclodextrin-modified electrokinetic chromatography mode. Sample cleanup was carried out by acidification with HCl followed by liquid-liquid extraction with hexane:isopropanol (99:1 v/v). The complete enantioselective analysis was performed within 10 min, using 100 mmol L(-1) phosphoric acid/triethanolamine buffer, pH 2.6, containing 2.0% w/v sulfated beta-cyclodextrin as chiral selector; fenoprofen, another nonsteroidal anti-inflammatory drug, was used as internal standard. The calibration curves were linear over the concentration range of 0.25-125.0 microg mL(-1) for each enantiomer of ibuprofen. The mean recoveries for ibuprofen enantiomers were up to 85%. The enantiomers studied could be quantified at three different concentrations (0.5, 5.0 and 50.0 microg mL(-1)) with a coefficient of variation and relative error not higher than 15%. The quantitation limit was 0.2 microg mL(-1) for (+)-(S)- and (-)-(R)-ibuprofen using 1 mL of human plasma. The plasma endogenous compounds and other drugs did not interfere with the present assay. The analysis of real plasma samples obtained from a healthy volunteer after administration of 600 mg of racemic ibuprofen showed a maximum plasma level of 29.6 and 39.9 microg mL(-1) of (-)-(R)- and (+)-(S)-ibuprofen, respectively, and the area under plasma concentration-time curve AUC(0-infinity) (+)-(S)/AUC(0-infinity) (-)-(R) ratio was 1.87.  相似文献   

12.
A high-performance liquid chromatographic method for the simultaneous determination of di(2-ethylhexyl)phthalate (DEHP) and its major metabolite mono(2-ethylhexyl)phthalate (MEHP) in seminal plasma was developed and validated. The method involves liquid-liquid extraction followed by isocratic reversed-phase chromatography with diode-array detection. The recovery, selectivity, linearity, precision and accuracy of the method were evaluated from the analysis of spiked seminal plasma samples. The effect of mobile-phase composition and pH on the retention of the target analytes was investigated. The limits of detection were 0.010 and 0.015 microg/mL, for DEHP and MEHP, respectively. This method was used to analyze real samples in support of clinical studies on these potential endocrine disruptors.  相似文献   

13.
A novel capillary zone electrophoresis method is described for the determination of taurine in plasma. The method is rapidly executed and is highly selective for taurine as separation is based on the difference in ionisation of this amino acid from that of other amino acids. Following addition of homotaurine as internal standard, plasma proteins were precipitated with acetonitrile and the supernatant was derivatised with fluorescamine in the presence of a borate buffer. Capillary electrophoresis (CE) separations were carried out in reverse polarity mode at 27.5 kV on a Beckman P/ACE MDQ CE instrument, equipped with a diode array detector (DAD) set at 266 nm. The sample tray was cooled to 5 degrees C and separations were carried out at 20 degrees C. The fused-silica capillary was 50.2 cm in length (40.2 cm to detector) with an internal diameter of 75 microm. A capillary conditioning solution was applied daily in order to suppress the residual electroosmotic flow (EOF). The method, which was validated using feline plasma as the blank matrix, was shown to be linear and reproducible over the concentration range 2.5-100 microg/mL. The coefficients of variation (CVs) of replicate analyses were less than 4.5% at 1 microg/mL taurine in feline plasma and less than 3% for 2.5 microg/mL in human plasma. Recovery was estimated at 99.2% with a CV of 4.85%. It has been demonstrated that quantitation in aqueous solution yields similar results to those obtained by interpolation on a plasma calibration curve provided that subtraction for the taurine peak in unspiked plasma is carried out and that a suitable internal standard is employed.  相似文献   

14.
Gemcitabine (2'2'-difluorodeoxycytidine) is a pyrimidine analog used in the treatment of a variety of solid tumors. After intravenous (i.v.) administration, it is rapidly inactivated to 2'-deoxy-2',2'-difluorouridine (dFdU). A sensitive analytical method for the quantitation of gemcitabine is required for the assessment of alternative dosage and treatment schemes. A rapid and robust RP-HPLC assay for analysis of gemcitabine in human and animal plasma and serum was developed and validated using 2'-deoxyuridine (dU) and 5-fluoro-2'-deoxyuridine (5FdU) as internal standards. It is based on protein precipitation, the use of an Atlantis dC18 column of 100 mm length (inner diameter, 4.6 mm; particle size, 3 microm) and isocratic elution using a 10 mM phosphate buffer, pH 3.0, followed by isocratic elution with the same buffer containing 3% of ACN. For gemcitabine, RSD values for intraday and interday precision were < 4.4 and 5.3%, respectively, the LOQ was 20 ng/mL, and the assay was linear in the range of 0.020-20 microg/mL with an accuracy of > or =89%. The recovery for gemcitabine, dU and 5FdU was 86-98%. The assay was applied to determine gemcitabine levels in plasma samples of patients collected during and shortly after conventional infusion of 25-30 mg/kg body mass (levels: 2.0-18.9 microg/mL) and rats that received lower doses (1.5 mg/kg) via i.v., subcutaneous and oral drug administration (levels: 0.20-2.60 microg/mL). It could also be applied to estimate dFdU levels in human plasma.  相似文献   

15.
A novel capillary electrophoresis (CE) method with contactless conductivity detection suitable for the determination of glucosamine (GlAm) and K(+) in pharmaceuticals was devised. Under the optimum conditions (aqueous 30 mM acetate buffer of pH 5.2 as the background electrolyte; voltage 30 kV; 25 degrees C), GlAm (migrating as glucosaminium cation) was well separated from K(+) that could occur in the dosage forms as excipient. The CE analysis was performed in fused-silica capillaries (50 microm i.d., 75 cm total length, 27 cm to detector) and the separation took <3 min. The calibration graphs were linear for both GlAm (100-300 microg/mL; r(2)=0.997) and K(+) (15-75 microg/mL; r(2)=0.997) when using ethanolamine (100 microg/mL) as the internal standard. The LOD values (S/N=3) were 9.3 microg/mL for GlAm and 2.9 microg/mL for K(+). The method was applied to the assay of GlAm content in various dosage forms. Intermediate precision evaluated by determining the content of GlAm in a single formulation on 3 consecutive days was characterized by RSD 2.35% (n=15). Acceptable accuracy of the CE method was confirmed by the added/found GlAm recovery experiments (recoveries 94.6-103.3%) and by statistical comparison of the results attained by the proposed CE and a reference HPLC method.  相似文献   

16.
A CE method employing capacitively coupled contactless conductivity (C(4)D) compared to indirect UV-detection was developed for the analysis of phytochemically relevant flavonoids, such as 6-hydroxyflavone, biochanin A, hesperetin and naringenin. To ensure fast separation at highest selectivity, sensitivity and peak symmetry, the pH value and the concentration of the running BGE had to be optimized regarding both co- and counter-EOF mode. Optimum conditions were found to be 1.0 and 5.0 mM chromate BGE (pH 9.50) in the counter- and co-EOF mode, respectively. Validation of the established CE-C(4)D method pointed out to be approximately seven times more sensitive compared to indirect UV-detection applying the same conditions. The lower LOD defined at an S/N of 3:1 was found between 0.12 and 0.21 microg/mL for the analytes of interest using C(4)D and between 0.77 and 1.20 microg/mL using indirect UV-detection. Compared to an earlier published CE method employing direct UV-detection, C(4)D was found to be approximately two times more sensitive. Due to the lower baseline noise, C(4)D showed an excellent regression coefficient >0.99 compared to 0.93 when using indirect UV detection calibrating within a concentration range between 1 and 10 microg/mL. The influence of the sugar moiety on the conductivity of a flavonoid was studied upon the analysis of the aglycon hesperetin and the rutinosid hesperidin. The sugar moiety in hesperedin shows a higher conductivity compared to hesperetin. Finally, the optimized established CE-C(4)D method was applied to the determination and quantification of naringenin in Sinupret.  相似文献   

17.
A capillary electrophoresis method was optimized for the stereoselective analysis of the antidepressant drug fluoxetine and its main demethylated metabolite norfluoxetine using a cyclodextrin-modified sodium phosphate buffer at pH 2.5. The combination of a neutral and a negatively charged cyclodextrin, dimethylated-beta- and phosphated-gamma-respectively, provided the baseline enantiomeric separation of the two compounds. The very low concentrations of chiral selectors employed together with the use of a high sensitivity detection cell of special design (zeta-shaped) in a diode array UV detector allowed us to reach a limit of detection of 0.005 and 0.01 microg/mL for fluoxetine and norfluoxetine, respectively. Analysis of fluoxetine and norfluoxetine standard mixtures showed a reproducibility of migration times and peak area and linearity in the concentration range of 0.1-2.0 microg/mL. The optimized method was applied to the analysis of clinical serum and plasma samples of patients under depression therapy. In all the analyzed samples the enantiomeric forms of fluoxetine and norfluoxetine were easily identified. The fluoxetine and metabolite enantiomeric ratio confirmed the stereoselectivity of the metabolic process of the fluoxetine drug in accordance with the literature data.  相似文献   

18.
A sensitive reversed-phase high-performance liquid chromatographic (HPLC) method has been developed and validated for the determination of imatinib, a tyrosine kinase inhibitor, and its main metabolite N-desmethyl-imatinib (CGP74588) in human plasma and relevant murine biological matrices. A simple HPLC assay for the individual quantification of imatinib and CGP74588 in murine specimens has not been reported to date. Sample pre-treatment involved liquid-liquid extraction with tert-butyl-methyl ether. Imatinib, CGP74588 (metabolite) and the internal standard 4-hydroxybenzophenone were separated using a narrow bore (2.1 x 150 mm) stainless steel Symmetry C(18) column and detected by UV at 265 nm. The mobile phase consisted of 28% (v/v) acetonitrile in 50 mM ammonium acetate buffer pH 6.8 containing 0.005 M 1-octane sulfonic acid and was delivered at 0.2 mL/min. The calibration curve was prepared in blank human plasma and was linear over the dynamic range 10 ng/mL to 10 microg/mL). The accuracy was close to 100% and the within-day and between-day precisions were within the generally accepted 15% range. The validation results showed that the assay was selective and reproducible. This method was applied to study the pharmacokinetics of imatinib and its main metabolite in human and mice.  相似文献   

19.
Kriikku P  Grass B  Hokkanen A  Stuns I  Sirén H 《Electrophoresis》2004,25(10-11):1687-1694
Analysis of the beta-blockers oxprenolol, atenolol, timolol, propranolol, metoprolol, and acebutolol in human urine by a combination of isotachophoresis (ITP) and zone electrophoresis (ZE) was investigated. Methods were developed with a conventional capillary electrophoresis (CE) apparatus and a poly(methyl methacrylate) (PMMA) microchip system. With CE the separation of oxprenolol, atenolol, timolol, and acebutolol from a standard solution containing 5 microg/mL of each compound was accomplished by performing ZE with transient ITP. The electrolyte system consisted of 10 mM sodium morpholinoethane sulfonate (pH 5.5) and 0.1% methylhydroxyethylcellulose as the leading electrolyte and 30 mM ortho-phosphoric acid (pH 2.0) as both the terminating and the ZE background electrolyte. With the microchip system the separation of oxprenolol and acebutolol from a standard solution containing 10 microg/mL of each compound was accomplished by a coupled-channel ITP-ZE device using the same leading electrolyte solution as the CE system but 5 mM glutamic acid (pH 3.4) as terminating and background electrolytes. The systems were used for analyses of patient urine samples. Water-soluble hydrophilic matrix compounds were removed from the urine samples by solid-phase extraction (SPE). Limits of quantification below 5 microg/mL could be achieved. The PMMA ITP-ZE chip has not earlier been used for analyses of any drugs from urine samples.  相似文献   

20.
A method has been developed for the analysis of the antidepressant drug sertraline together with its main metabolite N-desmethylsertraline (DMS) in human plasma. It is based on CE with LIF detection (lambda = 488 nm). A SPE procedure is employed for biological sample pretreatment, followed by a derivatization step with FITC; reboxetine was the internal standard. The effect of CD, acetone and N-methyl-D-glucamine (GLC) as constituents of the BGE for analyte separation was investigated. The final BGE consisted of 20 mM carbonate buffer, pH 9.0, with 2.5 mM heptakis(2,6-di-O-methyl)-beta-CD, 50 mM GLC and 20% v/v acetone. With 30 kV applied voltage, the electrophoretic run is completed in 7.5 min. Linearity was observed in the plasma concentration range from 3.0 to 500 ng/mL for sertraline and 4.0 to 500 ng/mL for DMS. Extraction yield was >97.1%, precision - expressed as RSD% - was <3.7, accuracy (recovery) was >95.6%. Due to its sensitivity and selectivity, the method was suited for the analysis of plasma samples from patients undergoing therapy with sertraline.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号