首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The studies on reaction of newly obtained aminophosphonic acid diethyl ester derivatives of fluorene with Cr2O7 2–, CrO4 2–, CrO3Cl and CrO3 have been investigated using electronic, infrared,Raman and NMR spectral methods. It has been found that the resulting compounds are of the type (AH)2Cr2O7, whereA stands for the organic part of the molecule. The organic cation and solvent effects on the electronic states of pseudotetrahedrally arranged Cr(VI) anions are discussed.
Spektroskopische Untersuchungen über Reaktionen von Chrom(VI)-Verbindungen mit Aminophosphonsäure-Estern
Zusammenfassung Es wurden Elektronen-, Ultrarot-,Raman- und NMR-spektroskopische Untersuchungen beschrieben, die an neuen Verbindungen durchgeführt wurden, welche als Reaktionsprodukte von Cr2O7 2–, CrO4 2–, CrO3Cl und CrO3 mit Aminophosphonsäurediethylesterderivaten von Fluorene synthetisiert worden waren. Es wurde festgestellt, daß diese Verbindungen mit einer allgemeinen Formel (AH)2Cr2O7 beschrieben können werden, in derA den organischen Teil der Verbindungen bedeutet. Der Einfluß des organischen Kations wie auch der von Lösungsmitteln auf die Elektronenzustände des pseudotetraedrischen Cr(VI)-Anions wurde gleichfalls untersucht.
  相似文献   

2.
Summary Electrophoresis followed by neutron activation analysis was utilized to determine chromium(III) and (VI) in mixed solutions. These solutions proceeded from Cr(VI) adsorbed hydrotalcites heated at 800 °C to partially immobilize Cr in the Mg-Al oxide solid solution. Immobilization was studied by Cr lixiviation with NaCl solutions through the heated hydrotalcites. The results have shown that Cr lixiviated was in the form of CrO42- ions, mainly because some Cr(VI) was not completely reduced to Cr(III) during heating. Chromium lixiviated from HT-Cr sample, heated at 800 °C and γ-irradiated at 1000 kGys, was found, as well, in the form of CrO42- ions. Although γ-irradiation increases Cr immobilization in the solid, it does not reduce completely all CrO42- ions present in the solid and, therefore, some Cr is lixiviated through the solid in the form of CrO42- ion.  相似文献   

3.
Summary Uranium(VI) can be extracted as its 8-quinolinolate into acetonitrile by means of salting-out with ammonium and sodium acetates, respectively; the metal oxinates extracted give a well-defined dc polarogram with E 1/2=–0.80V and a sharp square wave (sw) polarogram with E p=–0.96V in the extract. The dc wave height and the sw peak current are directly proportional to the uranium(VI) concentration in the range of 6.0×10–6 to 4.0×10–4M at pH 6.7–10.0 and 8.0×10–7 to 2.8×10–5M at pH 10.5–11.0, respectively. A number of ions do not interfere in the presence of EDTA.
Polarographische Bestimmung von Uran(VI) nach Aussalz-Extraktion als 8-Hydroxychinolat mit Acetonitril
Zusammenfassung Uran(VI) kann durch Aussalzen mit Ammonium- bzw. Natriumacetat als Oxinat mit Acetonitril extrahiert werden. Das extrahierte Oxinat ergibt ein gut ausgebildetes Gleichstrompolarogramm mit E 1/2=–0,80 V bzw. ein scharfes square-wave-Polarogramm mit E p=–0,96 V. Die Gleichstrom-Stufenhöhe bzw. der square-wave-Peakstrom sind der U(VI)-Konzentration im Bereich 6,0·10–6-4,0· 10–4M (pH 6,7–10,0) bzw. 8,0·10–7-2,8·10 –5M (pH 10,5–11,0) direkt proportional. Durch Zusatz von EDTA kann eine Reihe von Störungen ausgeschaltet werden.
  相似文献   

4.
The interaction of Cr(VI) and Nitrotetrazolium Blue has been examined. A 12 NTB (CrO3Cl)2 ion-associate is formed and is extractable into 1,2-dichloroethane. The optimum conditions have been established. The molar absorptivity at 260 nm was (8.2 ± 0.06) × 104L mol–1cm–1. Beer's law was obeyed in the range 0.01–0.4 g ml–1 Cr(VI). A sensitive and selective method for determination of micro-quantities of Cr(VI) in soils and steels is suggested.  相似文献   

5.
Summary The HPLC behaviours of Cr(VI), Mo(VI) and V(V) peroxo complexes in a H2O2-8-hydroxyquinolinebipyridine system were studied by using pre-column in combination with on-column derivatisation. The chromatograms of Cr(VI), Mo(VI) and V(V) show them to be CrO2– 4, oxine-Mo peroxo and oxine-V-bipyridine peroxo complexes, respectively, and were used for the separation, identification and determination of Cr(VI), Mo(VI) and V(V) using acetonitrile-water as mobile phase. The calibration curves obtained for 20 l injections were linear for 1.4–7.0 mg/l Cr, 1.3–6.5 mg/l Mo and 0.7–3.4 mg/l V. The relative standard deviations were between 6 and 10%.
HPLC-Analyse von Cr, V und Mo unter Verwendung von Vorsäulen- in Kombination mit Säulenderivatisierung durch Oxin, Bipyridin und H2O2
  相似文献   

6.
This study describes the use of banana peel, a commonly produced fruit waste, for the removal of Cr(VI) from industrial wastewater. The parameters pH, contact time, initial metal ion concentration, and temperature were investigated and the conditions resulting in rapid and efficient adsorption (95% within 10 min) were determined. The binding of metal ions was found to be pH dependent with the optimal sorption occurring at pH 2. The retained species were eluted with 5 mL of 2 M H2SO4. To elucidate the mechanism of the process, total amounts of chromium and Cr(VI) were analyzed using flame atomic absorption and ultraviolet–visible (UV–vis) spectroscopic techniques, respectively. The Langmuir and Dubinin–Radushkevich (D–R) isotherms were used to describe the partitioning behavior for the system at different temperatures. Kinetics and thermodynamics of Cr(VI) removal by banana peel were also studied. The influence of diverse ions on the sorption behavior revealed that only Fe(II) ions (of those tested) suppressed the sorption of Cr(VI) ions to some extent. The method was applied for the removal of Cr(VI) from industrial wastewater.  相似文献   

7.
Summary The pyrolysed graphite L'vov platform of a tube furnace is considered as an electrode for the electrodeposition and speciation of chromium by electrothermal atomisation atomic absorption spectrometry (ETA-AAS). Firstly, a preliminary study of the Cr(VI)/Cr(III) voltammetric behavior at pH 4.70 on a glassy-carbon electrode is carried out. Secondly, the L'vov platform is used as a cathodic macro-electrode for the selective preconcentration of Cr(VI)/Cr(III) on a mercury film. Speciation of Cr(VI)/Cr(III) is carried out on the basis of the electrolysis potential (Ee): at pH 4.70 and Ee=–0.30 V, only Cr(VI) is reduced to Cr(III) and accumulated as Cr(OH)3 by adsorption on a mercury film; at Ee=–1.80 V both Cr(VI) and Cr(III) are accumulated forming an amalgam with added mercury(II) ions. Once the film has been formed, the platform is transferred to a graphite tube to atomise the element. The reliability of the method was tested for the speciation of chromium in natural waters and it proves to be highly sensitive thanks to the electroanalytical step. In all samples, the Cr(VI) concentration was less than the detection limit (0.15 ng ml–1), and the concentration of Cr(III) agrees with those of total chromium. The analytical recovery of Cr(VI) added to water samples [3.50 ng ml–1 of Cr(VI)] was 105±6.2%.  相似文献   

8.
The simultaneous determination of U(VI), Pu(VI), Pu(V) in 0.5–4.0 M NaOH has been elaborated by means of classical and differential pulse voltamperometry. U(VI) is determined with a dropping mercury electrode (DME) at the half-wave potential of E1/2=–0.89 V vs. Ag/AgCl reference electrode due to reduction to U(V). The limiting current or peak heights are proportional to uranium(VI) concentration in the range of 1.3.10–7–3·10–4 M U(VI). Deviation from proportionality is observed for higher concentrations due to polymerization of uranates. Pu(VI) and Pu(V) are determined with a platinum rotating electrode at E1/2=–0.02 V due to the reaction Pu(VI)+e»Pu(V) and with DME at E1/2=–1.1 V due to the reduction to Pu(III). The limiting currents of both Pu(VI) and Pu(V) are proportional to their concentrations in the range of 4·10–6–1.2·10–3 M Pu. The determination of U(VI), Pu(VI), Pu(V) is not interfered by the presence of the following salts: 2M NaNO3, 2M NaNO2, 1.5M NaAlO2, 0.5M NaF and ions of Mo(VI), W(VI), V(V), Cu(II). The presence of CrO 4 2– and FeO 2 ions disturbs the determination of U(VI) in 1–4M NaOH, however, contribution of the reaction Fe(III)+e»Fe(II) to uranium reduction peak can be calculated from the height of the second peak Fe(II)+2 e»Fe(0).  相似文献   

9.
Salicylaldehyde rhodamine B hydrazone (SRBH) was developed as a new spectrofluorimetric probe for the selective and sensitive detection of CrO42− in acidic conditions. The proposed method was based on the special oxidation reaction between non-fluorescent SRBH by potassium dichromate to produce a highly fluorescent rhodamine B, as a product. Under the optimum conditions described, the fluorescence enhancement at 591 nm was good linearly related to the concentration of CrO42− from 1.0 × 10−8 to 3.0 × 10−7 M (0.42–12.6 ng mL−1) with a correlation coefficient of R2 = 0.9989 (n = 10) and a detection limit of 1.5 × 10−9 M (0.063 ng mL−1). The relative standard deviation (R.S.D.) was 2.0% (n = 6). The proposed method was also successfully applied to the determination of chromium (VI) in drinking water, river water and synthetic samples.  相似文献   

10.
Factors that influence the sorption of Cr(VI) and Cr(III) on aluminium hydroxide were investigated. The sorption of chromates decreases as the pH of the suspension increases. The mechanism of CrO 4 2– sorption was interpreted in terms of reactions between chromates and –OH and/or H2O groups at the hydroxide/liquid interface. It has been shown that chromates are more tightly sorbed on aluminium hydroxide compared to other anions, e.g. chlorides. On the other hand, specifically absorbed anions, such as molybdates, compete strongly with chromates for the sorption sites. The sorption of chromium(III) increases with the pH of the suspension. Also, the sorption of chromium(III) is suppressed in the presence of citrate ions. The best conditions for the fixation of Cr(VI) and Cr(III) by aluminium hydroxide are presented.  相似文献   

11.
Summary. A new selective, sensitive, and simple kinetic method is developed for the determination of trace amounts of chromium (VI). The method is based on the catalytic effect of Cr(VI) on the reaction of sodium pyrogallol-5-sulphonate (PS) with hydrogen peroxide. The reaction is followed spectrophotometrically by tracing the oxidation product at 437nm within 1min after addition of H2O2. The optimum reaction conditions are PS (1.32·10–3mol·dm–3), H2O2 (0.32mol·dm–3), HClO4 (2.6·10–3mol·dm–3) at 25°C. Following this procedure, chromium (VI) can be determined with a linear calibration graph up to 0.25ng·cm–3 and a detection limit of 0.024ng·cm–3, based on the 3 criterion. The interference effect of several species was also investigated and it was found that the most common cations and anions do not interfere with the determination. The developed procedure was successfully applied to the determination of Cr(VI) and total Cr in river waters and total Cr in herbal samples.  相似文献   

12.
It was demonstrated that Cl, SO4 2-, NO3 -, N3 -, ClO3 , and ClO4 ions can be simultaneously and selectively determined by capillary electrophoresis using 2,4-ionene as a capillary modifier. The effect of n-butanol additives to the buffer electrolyte on the migration times of ions was shown. The optimum buffer electrolyte contained 0.5 mM Na2CrO4, 0.05% 2,4-ionene, 10%n-butanol, and 7% methanol. It was shown that azide can be identified in wash solutions obtained at the place of lead azide explosion. The detection limit for azide was 1–3 mg/L.  相似文献   

13.
A novel in-capillary reduction and capillary electrophoretic (CE)-chemiluminescence (CL) method was developed for the sensitive and selective determination of chromium(III) and chromium(VI). The proposed method was based on the in-capillary reduction of Cr(VI) with acidic H2O2 to form Cr(III) using the zone-passing technique and chemiluminescence detection of Cr(III). The sample [Cr3+ and CrO42−], hydrochloric acid, and H2O2 (reductant) solution segments were injected for specified periods of time in this order from the anodic end of a capillary, followed by application of an appropriate running voltage between both ends. As both chromium species have opposite charges, Cr3+ migrates to the cathode while CrO42− ion, moving oppositely to the anode, reacts with acidic H2O2, resulted in formation of Cr3+. Based on the migration time difference of both Cr3+ ions, they were separated by zone electrophoresis. Running buffer was composed of 0.02 mol l−1 HAc-NaAc (pH 4.7) with 1×10−3 mol l−1 EDTA. Parameters affecting CE-CL separation and detection, such as reductant concentration, mixing mode of the analytes with CL reagent, CL reaction reagent pH and concentration, stability of luminol-hydrogen peroxide mixed solution were optimized. The limits of detection for chromium(III) and chromium(VI) (3σ) were 6×10−13 mol l−1 (mass concentration 12 zmol) and 8×10−12 mol l−1 (160 zmol), respectively. This method offered potential advantages of simplicity, sensitivity, selectivity and applicability to the determination of Cr(III) and Cr(VI) in environmental water.  相似文献   

14.
In acetate buffer medium palladium(II) ions form with promazine hydrochloride (PM) two complexes: an orange one of a formula [Pd(C17H20N2S)]2+max = 460 nm, ε = 4.5 × 103, at 20 °C and pH = 2) and a violet one of a formula [Pd(C17H20N2S)2]2+max = 540 nm, ε = 8.8 × 103 at 20 °C and pH = 2).The values for instability constants determined by Bjerrum's method amount to pK1 = 3.95; pK2 = 3.07; pβ1 = 3.95; pβ2 = 7.02, respectively.A colorimetric method of the determination of palladium(II) has been elaborated. The method consists in a measurement of the absorbance of the violet complex of palladium(II) with promazine hydrochloride at λ = 540 nm. The method permits the determination of 2–17 μg Pd/ml with an error of ±2%. The time of the determination is 20 min. Iron(III), Ce(IV), Pt(IV), V(V), Cr(VI), and HNO3 interfere with the determination.  相似文献   

15.
A new selective, sensitive, and simple kinetic method is developed for the determination of trace amounts of chromium (VI). The method is based on the catalytic effect of Cr(VI) on the reaction of sodium pyrogallol-5-sulphonate (PS) with hydrogen peroxide. The reaction is followed spectrophotometrically by tracing the oxidation product at 437nm within 1min after addition of H2O2. The optimum reaction conditions are PS (1.32·10–3mol·dm–3), H2O2 (0.32mol·dm–3), HClO4 (2.6·10–3mol·dm–3) at 25°C. Following this procedure, chromium (VI) can be determined with a linear calibration graph up to 0.25ng·cm–3 and a detection limit of 0.024ng·cm–3, based on the 3 criterion. The interference effect of several species was also investigated and it was found that the most common cations and anions do not interfere with the determination. The developed procedure was successfully applied to the determination of Cr(VI) and total Cr in river waters and total Cr in herbal samples.  相似文献   

16.
A novel adsorbent was developed from mature leaves of the Neem tree (Azadirachta Indica) for removing metal ions from water. The adsorbent, in the form of fine powder, was found to be very effective in removing chromium (VI) from aqueous solution. The adsorption was carried out in a batch process taking different concentrations of the metal ion in aqueous solution with variation in adsorbent amount, pH, agitation time and temperature. The suitability of the adsorbent was tested with Langmuir and Freundlich isotherms and with various equilibrium kinetic data. A small amount of the Neem Leaf Powder (NLP) (1.6 g dm–3) could remove as much as 87% of Cr (VI) in 300 min from a solution of concentration 14.1 mg dm–3 at 300 K. The optimum range of pH for the adsorption process was 4.5–7.5 and since the natural pH of the Cr (VI) solution was 5.5, no addition of acid or alkali was necessary for achieving maximum adsorption. The adsorption coefficients indicated a high potentiality for the NLP to be used as an adsorbent for removing Cr (VI) from water.  相似文献   

17.
Summary 2-Oximinodimedone dithiosemicarbazone reacts with Cr(VI) in strongly acid medium. The orange colour obtained has been used to propose a spectrophotometric method of Cr(VI) determination in the concentration range 0.40–9.5g ml–1 (=5600 mole–1-cm–1 at 485 nm). The stoichiometry of the reaction is 32 (reagentCr(VI)) which is in accordance with the oxidation reaction of the reagent by Cr(VI). The method has been applied to the determination of Cr(VI) and Fe(III) in ceramic materials.
Eine Studie zur Cr(VI)-2-oximinodimedondithiosemicarbazon-Reaktion und die simultane Bestimmung von Cr(VI) und Fe(III)
Zusammenfassung 2-Oximinodimedonedithiosemicarbazon reagiert in stark saurem Milieu mit Cr(VI). Die orange Farbe kann im Konzentrationsbereich von 0.4–9,5g/ml zur spektrophotometrischen Cr(VI)-Bestimmung verwendet werden (=5600 1 mol–1cm–1bei 485 nm). Die Stöchiometrie der Reaktion ist 32 (Reagens: Cr(VI)) und entspricht der Oxidation des Reagens durch Cr(VI). Die Methode wurde zur Bestimmung von Cr(VI) und Fe(III) in keramischen Materialien eingesetzt.
  相似文献   

18.
Competitive alkali metal cation transport across polymer inclusion membranes (PIMs) containing sym-(alkyl)dibenzo-16-crown-5-oxyacetic acid carriers provides excellent selectivity for Na+ transport with the total fluxes being strongly influenced by the length of the alkyl chain that is attached geminal to the functional side arm in the lariat ether. Removal of chromium(VI) anions by PIMs from acidic aqueous phases was also investigated. Using tri-n-octylamine (TOA) as the ion carrier, Cr(VI) was removed by a PIM to decrease the source phase metal concentration from 1.0 to 0.010 ppm after 30 hours of transport. Competitive transport of Cr(VI) and Cr(III) ions from acidic source phases through PIMs and supported liquid membranes (SLMs) containing TOA and tri-n-octylphosphine oxide (TOPO) as carriers was evaluated and a very high Cr(VI)/Cr(III) separation ratio of 4800 was achieved with a PIM containing TOA. Competitive transport of Zn(II), Cd(II), and Cr(VI) from acidic aqueous solutions through PIMs containing TOA was investigated. The selectivity order for metal ion transport was: HCrO4 >CdCl4 2–+CdCl3 >ZnCl4 2–+ ZnCl3 . Non-contact atomic force microscopy was used to obtain images of the pores in cellulose triacetate membranes containing a plasticizer.  相似文献   

19.
The ESR and EDRS methods were used to study the effect of adsorption of water and oxygen molecules at room temperature on the valence transformations and coordination transformations of Cr(III) and Cr(V) ions in a tetrahedral ligand environment and Cr(V) ions in square-pyramid coordination, ions that were formed on the surface of SiO2 after vacuum heat treatment of CrO3/SiO2 samples at 1173 K.Translated from Teoreticheskaya i Éksperimental'naya Khimiya, Vol. 28, No. 4, pp. 372–377, July–August, 1992.  相似文献   

20.
Liquid-liquid extraction of Th(IV) and U(VI) has been investigated by commercial extractant PC-88A in toluene. The optimum conditions for extraction of these metals have been established by studying the various parameters like acid concentration/pH, reagent concentration, diluents and shaking time. The extraction of Th(IV) was found to be quantitative with 0.1–1.0M HNO3 acid and in the pH range 1.0–4.0 while U(VI) was completely extracted in the pH range 1.0–3.5 with 2.5·10–2M and 2.·10–2M PC-88A in toluene, respectively. The probable extracted species have been ascertained by log D-log C plot as ThR4·4HR and UO2R2·2HR, respectively. The method permits separation of Th(IV) and U(VI) from associated metals with a recovery of 99.0%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号