首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A specific, sensitive and accurate quantitative analysis of testosterone propionate in human plasma was developed using gas chromatography-mass spectrometry-selected-ion monitoring. For the calculation of testosterone propionate in plasma, peak height ratios were measured by selected-ion monitoring performed on the molecular ions of the trifluoroacetyl derivative of testosterone propionate (m/z 440) and testosterone propionate-19,19,19-d3 (m/z 443). The sensitivity of the method was judged from the lower limit of the detection of the mass spectrometer which was at 20 pg. The inter-assay coefficients of variation and relative error at a concentration of 1.31 ng/ml of plasma were 5.47% and -2.3%, respectively. The method described was applied to the determination of plasma concentrations of testosterone propionate-19,19,19-d3 following an intramuscular dose of testosterone propionate-19,19,19-d3 in a healthy male volunteer.  相似文献   

2.
3.
建立了金属标记结合高效液相色谱-选择性离子监测质谱(SIM)的蛋白质绝对定量新方法。实验考察了金属标记效率、金属标记的稳定性、标记后肽段的色谱保留和质谱行为、新定量方法的线性范围和准确度。实验结果表明金属标记具有标记效率高,稳定性好,色谱保留行为一致等优点。另外,金属标记-选择离子监测质谱绝对定量方法灵敏度高,其定量限低至1 fmol,线性范围为1~500 fmol,线性范围内R2值大于0.99,具有良好的线性关系;经过测量,标准肽段的回收率为117.01%,说明该方法具有较高的准确度。将该方法应用于腾冲嗜热菌中烯醇酶蛋白的定量分析,相对标准偏差为5.47%,表明该方法的精密度高。以上结果表明该方法可以用于生物样本中的蛋白质的绝对定量分析,为比较简单的生物样本中蛋白质的绝对定量方法提供了一种新的选择。  相似文献   

4.
A rapid analytical method has been developed for the determination of polybrominated diphenyl ethers (PBDEs) in human hair. PBDEs were determined by gas chromatography with electron ionization mass spectrometric detection in the selected ion monitoring mode (GC-MS-SIM). A 200 mg amount of hair samples was overnight digested in 3N HCl and then PBDEs extracted with n-hexane. After clean up of extracts in a Florisil column, PBDEs were analyzed by GC-MS. The method has been validated by spiking human hair at five concentration levels, in the range from 5 to 25 ng/g for most compounds, and PBDEs were quantified using labelled compounds as internal standards. Recoveries of PBDEs were higher than 90%, repeatability was equal or lower than 12.5%, and reproducibility lower than 14%, expressed as relative standard deviation (RSD). Limits of detection (LOD) were in the range 0.08-0.9 ng/g and limits of quantification (LOQ) were between 0.27 and 3.0 ng/g. This method was applied to the determination of PBDEs in hair samples from 16 individuals and 5 PBDE congeners were detected in most of the samples. BDE-209 was the dominant compound found, followed by BDE-47, BDE-99, BDE-100, and BDE-190. BDE-209 was found in 12 out of 16 hair samples, and the total levels of PBDEs ranged from 1.4 to 19.9 ng/g.  相似文献   

5.
Testosterone undecanoate (T‐C11) can be used by athletes in order to improve performance. After oral intake, T‐C11 is rapidly metabolized, hampering discrimination between exogenous and endogenous testosterone. A possible alternative is to detect the intact ester in hair. A method based on liquid chromatography–tandem mass spectrometry was developed for the determination of T‐C11 in hair. The sample procedure consisted of digestion of 200 mg of pulverized hair with tris(2‐carboxyethyl)phosphine hydrochloride and liquid–liquid extraction with n‐pentane. Several parameters such as the mobile phase, the ionization source and the washing step were optimized. The method was validated at different spiked levels obtaining satisfactory values for accuracy (between 92 and 102%) with relative standard deviations lower than 7% and a limit of detection of 0.2 ng/g. The applicability of the method was checked by the analysis of three samples from patients using T‐C11. A peak for the analyte was detected in all samples with concentrations between 0.4 and 8.4 ng/g. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
This work describes a sensitive method for determining cholesterol in human hair using GC-MS. In this study, we used a very small amount of hair, only 1 mg, to quantify cholesterol. We also can achieve more effective purification and a good recovery over 92% with solid-phase extraction using an Oasis HLB cartridge. The intra-day and inter-day precision and accuracy values were less than 7.08%. Cholesterol was determined to be in the range of 355-1693 microg/g in healthy human hair. We tested the concentration correlation between the serum and hair to examine the feasibility of using the hair cholesterol level as an index of the serum cholesterol level. The correlation between the serum cholesterol was 0.86 (r-value) in patients with hypercholesterolemia. This finding indicates that, in the clinical field, hair could replace serum in cholesterol level measurement.  相似文献   

7.
V Ferchaud  B Le Bizec  F Monteau  F André 《The Analyst》1998,123(12):2617-2620
A new approach was developed in order to control testosterone abuse in animal production. A gas chromatographic-combustion-isotope ratio mass spectrometric (GC-C-IRMS) method was used to distinguish the exogenous character from the endogenous character of the main metabolites of testosterone (epitestosterone and etiocholanolone) in cattle urine. This method is based on a comparison between the carbon isotope ratio (13C/12C) of testosterone metabolites and those of testosterone endogenous precursors. After urinary steroid purification, extracts were acetylated with acetic anhydride and injected into the GC-C-IRMS system. In order to validate the method, testosterone enanthate was administered to a 4 year old cow. The 13C/12C isotope ratios of testosterone exogenous metabolites appeared to be significantly different to the 13C/12C precursor ratios and were detected until 3 weeks after the anabolic administration. These preliminary results appear to be promising for the difficult control of natural hormones in livestock.  相似文献   

8.
A procedure for the analysis of 112 halogenated pesticides that do not contain phosphorus has been developed. The procedure uses gas chromatography with a mass selective detector (GC-MSD), electron impact ionization, and selected-ion monitoring. This GC-MSD procedure provided lower limits of quantitation and provided increased confirmational data compared to the traditional element-selective GC procedures that are commonly used for the detection of this class of pesticides. These analytical improvements were demonstrated by the 25 pesticides that were detected at < or =50 ng/g levels in a variety of fruit and vegetable matrixes using this procedure that were missed by the traditional element selective GC procedures. Validation of the procedure was performed using 20 representative target pesticides with an acetone extraction and a solid-phase extraction cleanup. These target pesticides were used to demonstrate repeatability and linearity of the chromatographic response and recovery from fruit and vegetable matrixes.  相似文献   

9.
Choi MH  Kim KR  Chung BC 《The Analyst》2000,125(4):711-714
An efficient procedure is described for the determination of estrone and 17 beta-estradiol in hair by gas chromatography-mass spectrometry (GC-MS). The method involves alkyloxycarbonylation with isobutyl chloroformate (isoBCF) of phenolic hydroxy groups after alkaline digestion of hair samples. The resulting isobutyloxycarbonyl derivatives of estrone and 17 beta-estradiol are extracted with hexane and subjected to chlorodifluoroacetyl derivatization in order to protect the remaining alcoholic hydroxy groups. When GC-MS with selected ion monitoring (SIM) was used, the quantitative ions were at m/z 270 and 384 in the electron ionization mass spectra for estrone and 17 beta-estradiol, respectively. The detection limits for SIM of the steroids were 1 and 2 pg, respectively, and the SIM responses were linear with correlation coefficients varying from 0.991 to 0.994 in the concentration range 0.2-4.0 ng g-1 for the estrogens studied. The detection of estrone and 17 beta-estradiol in hair samples was possible in the concentration range of 0.24-1.30 ng g-1. The concentrations of the two estrogens detected were different in male and female hair samples.  相似文献   

10.
头发中内源性类固醇激素的气相色谱-串联质谱分析   总被引:2,自引:1,他引:2  
沈敏  向平  沈保华  王萌烨 《色谱》2008,26(4):454-459
建立了建康人头发中内源性类固醇兴奋剂睾酮、表睾酮、雄酮、苯胆烷醇酮和脱氢表雄酮的气相色谱-串联质谱(GC-MS/MS)分析方法。头发经碱水解后,以乙醚提取,经衍生化后采用GC-MS/MS的多反应监测模式(MRM)分析。方法的线性关系良好,检出限达0.1~0.2 pg/mg;提取回收率为74.6%~104.5%;日内测定的准确度为90.1%~113.7%,日内及日间测定的精密度均小于17.5%。应用所建立的方法测定了80例中国健康人头发中睾酮、表睾酮、雄酮、苯胆烷醇酮和脱氢表雄酮的生理水平,为内源性类固醇兴奋剂滥用的判断提供了方法和基础数据。  相似文献   

11.
12.
13.
A gas chromatography/mass spectrometric (GC/MS) method was developed and validated for the determination of thirteen psychotropic phenylalkylamine derivatives (amphetamine; AP, phentermine; PT, methamphamine; MA, cathinone; Khat, methcathinone; MCAT, fenfluramine; FFA, desmethylselegiline; DSEL, 3,4-methylenedioxyamphetamine; MDA, 3,4-methylenedioxymethamphetamine; MDMA, 3,4-methylenedioxyethylamphetamine; MDEA, norketamine; NKT, mescaline; MES, 4-bromo-2,5-dimethoxyphenethylamine; 2CB) in human hair. Hair samples (20 mg) were washed with distilled water and acetone, cut into small fragments (<1 mm), and incubated in 0.25 M methanolic HCl under ultrasonication at 50 degrees C for 1 h. The resulting solutions were evaporated to dryness, derivatized using trifluoroacetic anhydride (TFAA) at 70 degrees C for 30 min, and analyzed by GC/MS. The linear ranges were 0.02-25.0 ng/mg for AP, PT, Khat, FFA, DSEL, MDMA, and 2CB; 0.05-25.0 ng/mg for MA, MCAT, and MES; 0.05-12.5 ng/mg for MDA; and 0.1-25.0 ng/mg for MDEA and NKT, with good correlation coefficients (r(2) > 0.9985). The intra-day, inter-day, and inter-person precisions were within 12.7%, 14.8%, and 16.8%, respectively. The intra-day, inter-day, and inter-person accuracies were between -10.7 and 13.4%, -12.7 and 11.6%, and -15.3 and 11.9%, respectively. The limits of quantifications (LOQs) for each compound were lower than 0.08 ng/mg. The recoveries were in the range of 76.7-95.6%. The method proved to be suitable for the simultaneous qualification and quantification of phenylalkylamine derivatives in hair specimens.  相似文献   

14.
15.
The determination of tetra- to octachlorodibenzo-p-dioxins and tetra- to octachlorodibenzofurans (PCCD/Fs) by high-resolution gas chromatography/tandem mass spectrometry (HRGC/MS/MS) and high-resolution gas chromatography/triple mass spectrometry (HRGC/MS(3)) in a quadrupole ion trap, equipped with an external ion source, is presented. MS/MS involves a typical four-step process, namely ionization, parent ion isolation, collision-induced dissociation (CID) and mass analysis of the daughter ions. For the MS(3) experiment, the MS/MS scan function is used with the addition of selected daughter ion isolation, their CID and the mass analysis of second-generation product ions called 'grand-daughter ions.' For both methods, the energies necessary for the CID of the 17 PCDD/Fs were determined and optimized using multiple scan functions with different CID amplitudes. The CID efficiency, defined as the signal ratio of fragment ions detected from the major dissociation channels to molecular ions isolated, was 1.15-2.40 V for parent ion dissociation (MS/MS) and 1.05-1.50 V for daughter ion dissociation (MS(3)) and for all the chloro congeners. The same sensitivity (1 pg microl(-1)) can be reached with both the MS/MS and MS(3) methods and linear responses were obtained between 1 and 100 pg microl(-1) injected.  相似文献   

16.
Miyaguchi H  Inoue H 《The Analyst》2011,136(17):3503-3511
An LTQ Orbitrap XL hybrid mass spectrometry method was developed for the determination of illicit drugs and their metabolites, including amphetamine (AP), methamphetamine (MA), dimethylamphetamine (DMA), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), ketamine (KET), norketamine (NK), cocaine (COC) and benzoylecgonine (BE), in hair. Micropulverized extraction was employed for sample preparation using a small hair sample (2 cm piece or 0.2 mg). Recoveries of the analytes during sample preparation were estimated using fortified hair samples and ranged from 35.5% for COC to 71.7% for AP. High resolution full-scan mass spectra and unit resolution product-ion spectra were obtained with the Orbitrap analyzer and the linear ion-trap analyzer, respectively. High-resolution extracted ion chromatograms at a tolerance of 3 ppm were utilized for quantification. The analytes were identified using the product-ion spectra in combination with the accurate masses of the corresponding protonated molecules observed in the high-resolution mass spectra. Lower limits of quantification obtained from a 0.2 mg hair sample were 0.050 ng mg(-1) (MDMA, KET and BE), 0.10 ng mg(-1) (AP, MA, DMA, NK and COC) and 0.50 ng mg(-1) (MDA). Two reference materials were analyzed for verification, and segmental analysis of single strands of hair specimens from actual cases was performed.  相似文献   

17.
An analytical method was developed for quantitating low concentrations of the isomers cis- and trans-1,3-dichloropropene in whole rat blood by gas chromatography and gas chromatography-chemical ionization mass spectrometry with selected ion monitoring.  相似文献   

18.
A new method is described for the qualitative and quantitative analysis of midazolam, a short-acting 1,4-imidazole benzodiazepine, in human plasma. It involves a plasma deproteinization step, solid-phase microextraction (SPME) of midazolam using an 85-microm polyacrylate fiber, and its detection by gas chromatography/mass spectrometry (GC/MS) in selected ion monitoring (SIM) mode, using pinazepam as internal standard. The assay is linear over a midazolam plasma range of 1.5-300 ng/mL, relative intra- and inter-assay standard deviations at 5 ng/mL are below 7%, and the limit of detection is 1 ng/mL. The method is simple, fast and sufficiently sensitive to be applied in clinical and forensic toxicology as well as for purposes of therapeutic drug monitoring.  相似文献   

19.
Hydroxylated polychlorinated biphenyls also known as biphenylols, are suspected estrogen mimics found in the environment. Various derivatization schemes were evaluated and a gas chromatography–ion trap mass spectrometry method was developed for the trifluoroacetyl derivative using MS–MS techniques for the analysis of eleven biphenylols. A time-segmented chromatographic method was developed using the respective MS–MS parameters to analyze all the eleven biphenylols in a single chromatographic run. Isomers were differentiated based on the MS–MS data of the trofluoroacetyl-biphenylol derivatives. The method was applied to detect 40 pg on-column of these compounds in a spiked egg sample which simulates a real world sample.  相似文献   

20.
In this paper we describe an analytical method for the determination of p-phenylenediamine (PPDA) in hair dyes. In the adopted methodology the analyte is transformed into the corresponding imine derivative by treatment with benzaldehyde, and then analyzed by gas chromatography (GC) combined to mass spectrometry (MS), operating in SIM conditions. The direct and simultaneous chemical derivatization of the two amino functions of the analyte with benzaldehyde enhances the instrumental responses enabling the use of a sensitive and accurate method. Concentrations of PPDA in a set of commercial hair coloring creams are determined making use of N-benzylidene-4-methylbenzene-amine as a very stable internal standard which is easily prepared by condensation of 4-methylbenzene-amine with benzaldehyde. The regression calibration curves for PPDA in hair dyes are linear within 0.1 +/- 25 mg/ml with 0.99 as a typical correlation coefficient.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号