首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A method is described for the simultaneous analysis of 14 non-steroidal anti-inflammatory drugs (NSAIDS) in human serum using negative electrospray ionization-tandem mass spectrometry (ESI-MS/MS). After addition of internal standard and protein precipitation using acetonitrile, samples were transferred to autosampler vials for direct analysis without chromatography. Injection of an air bubble with the sample and a multiple reaction monitoring (MRM) method using argon collision-induced dissociation (CID) of analyte (M-H)? ions permitted integration of the product ion peak areas to produce reproducible quantitative data over the range of concentrations expected in serum during routine use of these drugs. The method permitted the analysis of 30 samples per hour. Two hundred fifty consecutive analyses did not adversely affect instrument sensitivity.  相似文献   

2.
A rapid method has been developed to analyse carprofen (CPF), diclofenac (DCF), mefenamic acid (MFN), niflumic acid (NIFLU), naproxen (NAP), oxyphenylbutazone (OXYPHEN), phenylbutazone (PBZ) and suxibuzone (SUXI) residues in bovine milk. Milk samples are extracted with acetonitrile and sample extracts were purified on Evolute™ ABN solid phase extraction cartridges. Aliquots were analysed by rapid resolution liquid chromatography tandem mass spectrometry (RRLC-MS/MS) with a runtime of 6.5 min. The method was validated in bovine milk, according to the criteria defined in Commission Decision 2002/657/EC. CCα values of 0.46, 1.08, 0.92, 1.26, 1.29, 2.12, 0.55 and 2.86 ng mL−1 were determined for CPF, DCF, MFN, NIFLU, NAP, OXYPHEN, PBZ and SUXI, respectively. CCβ values of 0.79, 1.85, 1.56, 2.15, 2.19, 3.62, 0.94 and 4.87 ng mL−1 were determined for CPF, DCF, MFN, NIFLU, NAP, OXYPHEN, PBZ and SUXI, respectively. The measurement uncertainty of the method was estimated at 9, 28, 28, 45, 46, 45, 10 and 39% for CPF, DCF, MFN, NIFLU, NAP, OXYPHEN, PBZ and SUXI. Fortifying bovine milk samples (n = 18) in three separate assays, show the accuracy of the method to be between 82 and 108%. The precision of the method, expressed as RSD values for the within-lab reproducibility at the three levels of fortification (5, 7.5 and 10 ng mL−1) was less than 16%, respectively. The advantage of the method is that low ng mL−1 levels can be detected and quantitatively confirmed rapidly in milk and that 3 batches of samples can be analysed within a single day using RRLC-MS/MS with a runtime of 6.5 min.  相似文献   

3.
Summary A high performance liquid chromatographic system has been developed for the resolution of ten anti-inflammatory drugs. Isocratic separation was achieved using a Spherisorb 5m ODS column with an eluent consisting of water-orthophosphoric acid to pH 3.2: acetonitrile: methanol (523513). A comparison was made between chloroform/acetonitrile (32) and hexane/ether (11) as solvents for the extraction of these drugs from serum.  相似文献   

4.
A method was developed for the extraction of stanozolol, taleranol, zeranol, hexestrol, dienestrol, ethynylestradiol, diethylstilbestrol, and trenbolone from animal urine. The analytes were extracted from the matrix by enzymatic hydrolysis, solid-phase extraction, and liquid-liquid extraction. Detection and quantitation were performed on a high-performance liquid chromatography system coupled to a triple quadrupole mass spectrometer. The identification criteria met the European Union regulations. Validation of this method established a decision limit between 0.2 and 0.9 microg/L and a detection capability between 0.3 and 1.0 microg/L, depending on the analyte.  相似文献   

5.
A rapid and sensitive method for the determination of miglitol in human plasma using voglibose as internal standard has been developed and validated. Samples of plasma were deproteinated with acetonitrile and washed with dichloromethane before being analyzed by reversed-phase high-performance liquid chromatography (HPLC). Separation was carried out on a short Nucleosil C(18) column (5 microm, 50 x 4.6 mm i.d.) using 10 mmol/L ammonium acetate at 1.0 mL/min as mobile phase. The detector was an Applied Biosystems Sciex API 4000 mass spectrometer using atmospheric pressure chemical ionization (APCI) for ion production. The instrument was operated at unit resolution in the multiple reaction monitoring mode. The assay was linear over the range 5.00-2000 ng/mL with a limit of detection of 1.00 ng/mL. Intra- and inter-day precision were <2.82% and <2.92%, respectively, with accuracy of 93.3-106%. The assay was successfully applied to a clinical pharmacokinetic study of miglitol given as a single oral dose (50 mg) to healthy volunteers.  相似文献   

6.
A sensitive and selective high-performance analytical method based on liquid chromatography with tandem mass spectrometric detection (LC/MS/MS) was developed for the quantification of glufosfamide in rat plasma. Zidovudine was employed as internal standard. Glufosfamide was determined after methanol-mediated plasma protein precipitation using LC/MS/MS with an electrospray ionization interface in negative ion mode. Two sets of standard curves were developed, from 0.005 to 1.0 microg/mL and from 1.0 to 50.0 microg/mL. The assay was accurate (% deviations from nominal concentrations < 5%), precise and reproducible (intra- and inter-day coefficients of variation < 10%). Glufosfamide in rat plasma was stable over three freeze/thaw cycles, and at ambient temperatures, for at least 2 h. The validated method was successfully applied to the determination of glufosfamide plasma concentrations in rats for 24 h following an intravenous administration of 25 mg/kg.  相似文献   

7.
A method for the quantification of clindamycin in animal plasma using high-performance liquid chromatography combined with electrospray ionization mass spectrometry (LC/ESI-MS/MS) is presented. Lincomycin is used as the internal standard. The sample preparation includes a simple deproteinization step with trichloroacetic acid. Chromatographic separation is achieved on an RP-18 Hypersil column using gradient elution with 0.01 M ammonium acetate and acetonitrile as mobile phase. Good linearity was observed in the range 0-10 microg ml(-1). The limit of quantification of the method is 50 ng ml(-1) and the limit of detection is 1.3 ng ml(-1). The method was shown out to be of use for pharmacokinetic studies of clindamycin formulations in dogs.  相似文献   

8.
A sensitive and selective liquid chromatography mass spectrometry method for determination of curdione in rabbit plasma was developed. After addition of tramadol as internal standard (IS), protein precipitation by acetonitrile was used for sample preparation. Chromatographic separation was achieved on a Zorbax SB‐C18 (2.1 × 50 mm, 3.5 µm) column with acetonitrile–0.1% formic acid as mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive‐ion mode; selective ion monitoring was used for quantification using target fragment ions m/z 237 for curdione and m/z 264 for the IS. Calibration plots were linear over the range of 20–4000 ng/mL for curdione in plasma. The lower limit of quantification for curdione was 20 ng/mL. Mean recovery of curdione from plasma was in the range 94.3–98.4%. The RSD of intra‐day and inter‐day precision were both less than 9%. This method is simple and sensitive enough to be used in pharmacokinetic research for the determination of curdione in rabbit plasma. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

9.
A novel, sensitive and specific method for the quantitative determination of diclazuril in animal plasma using liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) with negative ion detection is presented. Extraction of the samples was performed with a rapid deproteinization step using acetonitrile. Chromatography of diclazuril and the internal standard was achieved on a Nucleosil ODS 5-microm column, using a gradient elution with 0.01 M ammonium acetate and acetonitrile. To obtain the highest sensitivity and specificity possible, the mass spectrometer was operated in the multiple reaction monitoring (MRM) mode. The method was validated according to the requirements defined by the European Community. Calibration curves using plasma fortified between 1-100 ng/mL and 100-2000 ng/mL showed good linear correlation (r >or= 0.9991, goodness-of-fit coefficient 相似文献   

10.
On-line atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) liquid chromatography/mass spectrometry (LC/MS) were evaluated for the analysis of a variety of steroids. Steroids were classified into three major groups based on the spectra and the sensitivities observed: (I) those containing a 3-one, 4-ene functional group, (II) those containing at least one ketone group without conjugation, and (III) those containing hydroxy group(s) only. In the APCI mode, the best sensitivity and the lowest detection limit for all three groups were obtained by using a mobile phase consisting of methanol and 1%–2% acetic acid in water. The APCI spectra were characterized by MH+, MH+-H2O, MH+-2H2O, etc., with the degree of H2O loss being compound dependent: group I steroids produced stable MH+ and group III steroids showed extensive water loss. In the electrospray mode the best sensitivity and the lowest detection limit for the first two groups were obtained when pure methanol and water were used as the mobile phase. This condition produced abundant stable MNa+ due to ubiquitous sodium. Detection limits in the 5–15 pg range can be easily achieved using ESI LC/MS. Addition of ammonium acetate or use of acetonitrile in the mobile phase, common in the LC/MS analysis of steroids, decreased the sensitivity for the group I and II steroids and thus should be avoided. For group III steroids, the detection limit can be improved by the addition of acetic acid to the mobile phase.  相似文献   

11.
Gatifloxacin is an advanced-generation, 8-methoxyfluoroquinolone that is active against a broad spectrum of pathogens, including antiobiotic resistant Streptococcus pneumoniae. Development of a rapid, sensitive and selective method for the determination of gatifloxacin in human plasma is essential for understanding the pharmacokinetics of the drug when administered orally or intravenously. Solid phase extraction (SPE) using Oasis HLB was used to extract gatifloxacin and the internal standard ciprofloxacin from plasma. A method based on liquid chromatography/electrospray tandem mass spectrometry (LC/ESI-MS/MS) was developed and validated to quantitate gatifloxacin in human plasma. The precursor and major product ions of the analyte were monitored on a triple quadrupole mass spectrometer with positive ion electrospray ionization (ESI) in the multiple reaction monitoring (MRM) mode. Mechanisms for the formation of collision-induced dissociation products of gatifloxacin are proposed. Linear calibration curves were generated from 10--1000 ng/mL with coefficients of determination greater than 0.99. The interday and intraday precision (%RSD) was less than 6.0% and accuracy (%error) was less than 5.4% for gatifloxacin. The limit of detection (LOD) for the method was 500 pg/mL based on a signal-to-noise ratio of 3.  相似文献   

12.
A method is described for the evaluation of drug concentrations in plasma and brain from treated rats. The analyte is recovered from plasma or brain homogenate by liquid-liquid extraction and subsequently analyzed by liquid chromatography/tandem mass spectrometry (LC/MS/MS). A simple experimental protocol renders the procedure valuable for obtaining information rapidly on brain penetration and plasma exposure of specific classes of compounds. This methodology has been applied to evaluate brain penetration with 30 different compounds from the same discovery program. In an attempt to increase throughput in our screening efforts, mixture dosing was evaluated. Results from single compound administration were compared with results following administration of a mixture of four compounds. Preliminary results, with specific classes of compounds, show no major differences (ranking order) in brain or plasma concentrations between mixture dosing and single compound administration, suggesting that mixture dosing could be applicable to brain penetration studies in the drug discovery phase.  相似文献   

13.
A triple-quadrupole instrument and a hybrid quadrupole/time-of-flight (TOF) mass spectrometer were compared for the determination of pharmaceutical compounds in water samples. The drugs investigated were the analgesics Ibuprofen, Fenoprofen, Ketoprofen, Naproxen, and Diclofenac. The recently introduced Q2-pulsing function, which enhances the transmission of fragment ions of a selected m/z window from the collision cell into the TOF analyzer, improved the sensitivity of product ion scans on the quadrupole/TOF instrument. The selectivity is much better on quadrupole/TOF systems than on triple quadrupoles because the high resolving power of the reflectron-TOF mass analyzer permits high-accuracy fragment ion selection. This minimizes interferences from environmental matrices and allows acquisition of full spectra for selected analytes with better signal-to-noise characteristics than comparable spectra obtained with a scanned quadrupole. The qualitative information obtained (mass accuracy, resolution and full-scan spectra) by hybrid quadrupole/TOF mass spectrometry allows a more certain identification of analytes in environmental matrices at trace levels. Sample enrichment of water samples was achieved by a solid-phase extraction procedure. Average recoveries for loading 1 L of samples varied from 88 to 110%, and the quantification limits were less than 1.2 ng/L for the triple-quadrupole instrument (in MRM mode) and less than 3 ng/L for the quadrupole/TOF instrument.  相似文献   

14.
Cefuroxime is a second-generation cephalosporin used against different kinds of bacterial infections. To be able to optimize the dosing it is necessary to characterize the pharmacokinetics of cefuroxime which requires a selective and sensitive analytical method for cefuroxime in plasma or serum. A new rapid liquid chromatography/electrospray tandem mass spectrometry (LC/MS/MS) method, using cefotaxime as internal standard, was developed for analysis of cefuroxime in human serum. The work-up procedure consisted of protein precipitation with acetonitrile/cefotaxime, and after centrifugation the supernatant was dissolved in mobile phase. The sample was injected on a SB-CN column and the detection was performed using tandem mass spectrometry (MS/MS). The limit of quantification was determined to 0.025 microg/mL. The method was linear in the range 0.025-50 microg/mL with a coefficient of correlation >0.999. The limit of quantification and intra-day variability were found to be the same for plasma samples, which indicates that the method is valid for serum as well as plasma samples.  相似文献   

15.
16.
17.
The objective of the present study is to develop a simple, fast method for detection of aflatoxins in animal feeds. Simultaneous quantitation of four aflatoxins (AFB(1), AFB(2), AFG(1) and AFG(2)) in animal feeds was achieved in a single liquid chromatography/tandem mass spectrometry (LC/MS/MS) run. The solid-phase extraction cleanup step is eliminated with the stable isotope dilution method. Matrix effects were observed and overcome by isotope dilution. The method was tested in a variety of animal feed matrices and proved to be accurate and reliable. Method ruggedness tests resulted in recoveries of 78% to 122% with an intra-day assay precision of 2% to 15% and an inter-day assay precision of 3% to 17%. These results indicate that this method is suitable for quantitation of aflatoxins in animal feeds.  相似文献   

18.
Isotope dilution liquid chromatography/tandem mass spectrometry (ID-LC/MS/MS) has been developed as a candidate reference method to determine the level of phenylalanine in human serum. The advantages of this method include a simple sample preparation without derivatization, selective detection of analytes, and the use of an isotopic analogue as an internal standard. Phenylalanine and its isotopic analogue, phenylalanine-ring-(13)C(6), were monitored at the transitions m/z 166.2/120.2 and 172.2/126.2 in the multiple-reaction monitoring (MRM) mode, respectively. The expanded uncertainty of the measurement result of phenylalanine in the serum was approximately 1.2% within a 95% confidence level. A standard reference material, with a certified value of phenylalanine, was analyzed in order to verify this method. The result obtained by the ID-LC/MS/MS method differed somewhat from the certified value, but agreed well with the gravimetric value. The measurement result of phenylalanine in serum by ID-LC/MS/MS was compared with the results from the commercial HPLC method, which was carried out in clinics. The results from the commercial HPLC method showed inconsistent results with each other. The busted results from the commercial HPLC method suggest that it should be possible to trace the results of the commercial fields to well-characterized reference materials or methods.  相似文献   

19.
A specific, sensitive, rapid and reproducible method for the determination of flomoxef in human plasma using high‐performance liquid chromatography–tandem mass spectrometry was developed and validated. Flomoxef was detected using an electrospay ionization method operated in negative‐ion mode. Chromatographic separation was performed in gradient elution mode on a Luna® C18(2) column (3 μm , 20 × 4.0 mm) at a flow rate of 1 mL/min and runtime 3.5 min. The mobile phase consisted of acetonitrile and water containing 0.1% formic acid as additive. Extraction of flomoxef from plasma and precipitation of plasma proteins was performed with acetonitrile with an absolute recovery of 86.4 ± 1.6%. The calibration curve was linear with a correlation coefficient of 0.999 over the concentration range 10–5000 ng/mL and the lower limit of quantification was 10 ng/mL. The intra‐ and inter‐day precisions were <11.8%, while the accuracy ranged from 99.6 to 109.0%. A stability study of flomoxef revealed that it could be successfully analyzed at 4ºС over 24 h, but it was unstable in solutions at room temperature during short‐term storage (4 h) and several freeze–thaw cycles. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

20.
A rapid, sensitive and robust assay procedure using liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS) for the determination of famotidine in human plasma and urine is described. Famotidine and the internal standard were isolated from plasma samples by cation-exchange solid-phase extraction with benzenesulfonic acid (SCX) cartridges. The urine assay used direct injection of a diluted urine sample. The chromatographic separation was accomplished by using a BDS Hypersil silica column with a mobile phase of acetonitrile-water containing trifluoroacetic acid. The MS/MS detection of the analytes was set in the positive ionization mode using electrospray ionization for sample introduction. The analyte and internal standard precursor-product ion combinations were monitored in the multiple-reaction monitoring mode. Assay calibration curves were linear in the concentration range 0.5--500 ng ml(-1) and 0.05--50 microg ml(-1) in plasma and urine, respectively. For the plasma assay, a 100 microl sample aliquot was subjected to extraction. To perform the urine assay, a 50 microl sample aliquot was used. The intra-day relative standard deviations at all concentration levels were <10%. The inter-day consistency was assessed by running quality control samples during each daily run. The limit of quantification was 0.5 ng ml(-1) in plasma and 0.05 microg ml(-1) in urine. The methods were utilized to support clinical pharmacokinetic studies in infants aged 0-12 months.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号