首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Desorption electrospray ion source (DESI) is widely used as an MS imaging technique. It is a rapid and convenient method of surface analysis, but to date, there are methodological obstacles to its application to the analysis of cell culture. This study reported optimised conditions for the analysis of cell culture samples. Parameters such as the surface, medium removal and sample desiccation techniques were assessed as a function of output data quality. Supercharging agents, surfactants and optimal parameters for the DESI ion source were evaluated for use in cell culture analyses. Data indicated that plastic dishes or sodium glass coated with poly‐l ‐lysine and washing cell cultures with 150 mM ammonium acetate followed by drying with inert gas were superior for DESI analyses. The addition of 1 μM surfactin to the DESI spray solvent significantly improved the results for negative and positive ion modes. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

2.
A desorption electrospray ionization (DESI) source has been coupled to an ion mobility time-of-flight mass spectrometer for the analysis of proteins. Analysis of solid-phase horse heart cytochrome c and chicken egg white lysozyme proteins with different DESI solvents and conditions shows similar mass spectra and charge state distributions to those formed when using electrospray to analyze these proteins in solution. The ion mobility data show evidence for compact ion structures [when the surface is exposed to a spray that favors retention of "nativelike" structures (50:50 water:methanol)] or elongated structures [when the surface is exposed to a spray that favors "denatured" structures (49:49:2 water:methanol:acetic acid)]. The results suggest that the DESI experiment is somewhat gentler than ESI and under appropriate conditions, it is possible to preserve structural information throughout the DESI process. Mechanisms that are consistent with these results are discussed.  相似文献   

3.
A new method for tissue imaging using desorption electrospray ionization (DESI) mass spectrometry is described. The technique utilizes a DESI source with a heated nebulizing gas and high‐resolution accurate mass data acquired with an LTQ‐Orbitrap mass spectrometer. The two‐dimensional (2D) automated DESI ion source creates images using the ions that are collected under high‐resolution conditions. The use of high‐resolution mass detection significantly improves the image quality due to exclusion of interfering ions. The use of a heated nebulizing gas increases the signal intensity observed at lower gas pressure. The technique developed is highly compatible with soft tissue imaging due to the minimal surface destruction. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
Desorption electrospray ionization (DESI) is implemented on an Orbitrap mass spectrometer. The ion source is described and applications which utilize the high-resolution capabilities of the Orbitrap are emphasized, including the characterization of peptides and active ingredients in pharmaceutical tablets. Measurements are made in less than 1 s at a resolution of 60,000. The implications of the data for the mechanisms of DESI are discussed.  相似文献   

5.
Sulfated oligosaccharides derived from glycosaminoglycans (GAGs) are fragile compounds, highly polar and anionic. We report here on the rare but successful application of desorption electrospray ionization (DESI) — LTQ‐Orbitrap mass spectrometry (MS) to the high‐resolution analysis of anionic and sulfated oligosaccharides derived from the GAGs hyaluronic acid and heparin. For that purpose, key parameters affecting DESI performance, comprising the geometric parameters of the DESI source, the probed surface and the spraying conditions, applied spray voltage, flow rates and solvent composition were investigated. Under suitable conditions, the DESI technique allows the preservation of the structural integrity of such fragile compounds. DESI enabled the sensitive detection of anionic hyaluronic acid and heparin oligosaccharides with a limit of detection (LOD) down to 5 fmol (≈10 pg) for the hyaluronic acid decasaccharide. Detection of hyaluronic acid oligosaccharides in urine sample was also successfully achieved with LOD values inferior to the ng range. Multistage tandem mass spectrometry (MSn) through the combination of the DESI source with a hybrid linear ion trap‐orbitrap mass spectrometer allowed the discrimination of isomeric sulfated oligosaccharides and the sequence determination of a hyaluronic acid decasaccharide. These results open promising ways in glycomic and glycobiology fields where structure–activity relationships of bioactive carbohydrates are currently questioned. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
We report high resolution spectra for the medium molecular weight proteins myoglobin and cytochrome-c obtained using a custom desorption electrospray ionisation (DESI) source coupled to a Bruker Daltonics 12 T Apex Qe Fourier transform ion cyclotron resonance mass spectrometer (FTICR-MS). The DESI source was designed for accurate alignment and reproduction of critical geometric variables. A two axis motorised stage was included to enable automated rastering of the sample under the DESI plume. Spectra for the intact proteins have been obtained under single-acquisition conditions and a top-down analysis of cytochrome-c was performed using both collision induced dissociation (CID) and electron capture dissociation (ECD) of the isolated [M+15H]15+ charge state. The sequence coverage is comparable to that obtained using electrospray ionisation, demonstrating the utility of top-down protein analysis by DESI FTICR-MS.  相似文献   

7.
Internal energy distributions in desorption electrospray ionization (DESI)   总被引:3,自引:2,他引:1  
The internal energy distributions of typical ions generated by desorption electrospray ionization (DESI) were measured using the "survival yield" method, and compared with corresponding data for electrospray ionization (ESI) and electrosonic spray ionization (ESSI). The results show that the three ionization methods produce populations of ions having internal energy distributions of similar shapes and mean values (1.7-1.9 eV) suggesting similar phenomena, at least in the later stages of the process leading from solvated droplets to gas-phase ions. These data on energetics are consistent with the view that DESI involves "droplet pick-up" (liquid-liquid extraction) followed by ESI-like desolvation and gas-phase ion formation. The effects of various experimental parameters on the degree of fragmentation of p-methoxy-benzylpyridinium ions were compared between DESI and ESSI. The results show similar trends in the survival yields as a function of the nebulizing gas pressure, solvent flow rate, and distance from the sprayer tip to the MS inlet. These observations are consistent with the mechanism noted above and they also enable the user to exercise control over the energetics of the DESI ionization process, through manipulation of external and internal ion source parameters.  相似文献   

8.
A source that couples the desorption ionization by charge exchange (DICE) and desorption electrospray ionization (DESI) techniques together was demonstrated to broaden the range of compounds that can be analyzed in a single mass spectrometric experiment under ambient conditions. A tee union was used to mix the spray reagents into a partially immiscible blend before this mixture was passed through a conventional electrospray (ES) probe capillary. Using this technique, compounds that are ionized more efficiently by the DICE method and those that are ionized better with the DESI procedure could be analyzed simultaneously. For example, hydroquinone, which is not detected when subjected to DESI-MS in the positive-ion generation mode, or the sodium adduct of guaifenesin, which is not detected when examined by DICE-MS, could both be detected in one experiment when the two techniques were combined. The combined technique was able to generate the molecular ion, proton and metal adduct from the same compound. When coupled to a tandem mass spectrometer, the combined source enabled the generation of product ion spectra from the molecular ion and the [M + H]+ or [M + metal]+ ions of the same compound without the need to physically change the source from DICE to DESI. The ability to record CID spectra of both the molecular ion and adduct ions in a single mass spectrometric experiment adds a new dimension to the array of mass spectrometric methods available for structural studies.  相似文献   

9.
Volný M  Venter A  Smith SA  Pazzi M  Cooks RG 《The Analyst》2008,133(4):525-531
Time resolved measurements show that during a desorption electrospray ionization (DESI) experiment, the current initially rises sharply, followed by an exponential decrease to a relatively steady current. When the high voltage on the spray emitter is switched off, the current drops to negative values, suggesting that the direction of current flow in the equivalent DESI circuit is reversed. These data demonstrate that the DESI source behaves as a dc capacitor and that the addition of a surface between the sprayer and the counter electrode in DESI introduces a new electrically active element into the system. The charging and discharging behavior was observed using different surfaces and it could be seen both by making current measurements on a plate at the entrance to the mass spectrometer as well as by measuring ion current in the linear ion trap within the vacuum system of the mass spectrometer. The magnitude of the steady state current obtained without analyte present on the surface is different for different surface materials, and different capacitor time constants of the equivalent RC circuits were calculated for different DESI surfaces. The PTFE surface has by far the greatest time constant and is also able to produce the highest DESI currents. Surface properties play a crucial role in charge transfer during DESI in addition to the effects of the chemical properties of the analyte. It is suggested that surface energy (wettability) is an important factor controlling droplet behavior on the surface. The experimental data are correlated with critical surface tension values of different materials. It is proposed, based on the results presented, that super-hydrophobic materials with extremely high contact angles have the potential to be excellent DESI substrates. It is also demonstrated, using the example of the neurotransmitter dopamine, that the surface charge that develops during a DESI-MS experiment can cause electrochemical oxidation of the analyte.  相似文献   

10.
Flared inlet capillary tubes have been coupled with a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer to help the ion transmission from the atmospheric pressure to the first vacuum region. We investigated different types of atmospheric pressure ionization methods using flared inlet tubes. For most of the ionization methods, such as ESI and DESI, increased ion current transmitted from the atmospheric pressure ion source to the first stage vacuum system was observed with the use of our enhanced ion inlet designs. The corresponding ion intensity detected on a FT-ICR mass spectrometer was also observed to increase two- to fivefold using ESI or DESI with the flared tube inlet. Moreover, increased spray tip positional tolerance was observed with implementation of the flared inlet tube. We also include our preliminary results obtained by coupling AP-MALDI with flared inlet tube in this paper. For AP-MALDI, the measured ion current transferred through the flared inlet tube was about 2 to 3 times larger than the ion current through the control non-flared inlet tube.  相似文献   

11.
Desorption electrospray ionization-mass spectrometry (DESI-MS) was evaluated for the direct analysis of liquid samples. Several interesting results were found. First, in contrast to the previous DESI analysis of dried solid samples that was limited to proteins with MW ≤25 kDa (Anal. Chem. 2007, 79, 3514), bovine serum albumin (BSA, 66 kDa) was successfully ionized from solutions by DESI with observation of corresponding multiply charged ions. Second, direct DESI analysis of protein tryptic digest solutions without chromatographic separation, sample clean-up, and the sample drying step was demonstrated, providing reasonably good sequence coverage of 52% to 97%. Third, direct analysis of biofluids such as an undiluted urine sample without sample pretreatment is possible, emphasizing the high tolerance of DESI with salt. These results suggest that a charged droplet pick-up mechanism is responsible for desorption and ionization of liquid samples by DESI. Also, unlike in electrospray ionization (ESI), inhibition of electrochemical reduction in the negative ion mode was observed for liquid sample DESI. In addition, reactive DESI can be performed with ion/ion reactions of Zn(II) complexes for the selective binding of phosphoserine in the presence of serine. DESI experiment can also be carried out directly to liquid samples flowing out of a pumped syringe needle tip, allowing rapid analysis. Furthermore, on-line coupling of electrochemical cell with DESI-MS was demonstrated, in which perylene radical cations generated in the cell were successfully transferred to the gas-phase for MS detection by DESI. This study extended the scope of DESI-MS applications, which could have potentials in bioanalytical and forensic analysis.  相似文献   

12.
薛震  邱波  林广欣  赖丛芳  罗海 《化学进展》2008,20(4):594-601
本文介绍了一种新近发展起来的质谱离子化方法——解吸电喷雾电离(desorption electrospray ionization, DESI)及其最新研究进展。该方法首次于2004年提出后,由于其具有样品无需前处理就可以在常压条件下从各种载物表面直接分析固相,或凝固相样品等优势而得到了迅速的发展。本文描述了DESI的基本原理、离子源的结构和相关优化的参数,并对该离子化方法中所用的载物表面进行了总结。在实际应用方面,本文综述了DESI技术在常压气相化学反应产物监测,合成高聚物表征,爆炸物和化学战毒剂检测,以及在药品,生物代谢产物和生物组织表面分析方面的应用成果,同时对DESI的基础应用研究方向进行了分析和展望。  相似文献   

13.
江玮  喻钢 《分析测试学报》2012,31(4):430-435
自建了简易的电喷雾解吸电离源(DESI),优化了DESI源喷口的位置和角度,并将其用于常见多肽和蛋白质的分析。多肽和小质量蛋白质(<20 kDa)可以容易地从表面解吸电离,生成清晰的质谱。而牛血清白蛋白(66.4 kDa)不能产生清晰的多电荷分布的质谱,说明当前DESI源的设计可能存在一个电离的分子量上限。通过比较不同的实验条件并对比ESI-MS,发现溶剂分子的挥发过程对电荷分布以及峰宽均有显著影响,可能是由于ESI更软引起。载样表面的性质对DESI-MS的信号强度有较大影响。金表面的自组装单分子膜(SAM)相对于纯金表面有较好的绝缘性,并有助于产生较强信号,说明来自表面的电子转移(电中和)是电喷雾解吸电离过程中的一个重要因素。该文的研究有助于对DESI-MS的实验条件和载样表面的选择,同时增进了对电喷雾解吸电离机理的了解。  相似文献   

14.
Desorption electrospray ionisation (DESI) has been successfully combined with a hybrid quadrupole time-of-flight mass spectrometer to provide mass spectra and product ion mass spectra of active ingredients formulated in pharmaceutical tablets, gels and ointments. Accurate mass data has been obtained from the DESI mass spectra and of the product ion fragments of selected ions, greatly enhancing the selectivity and information content of the experiment. This accurate mass information only takes seconds to acquire since the DESI technique does not require any sample preparation or extraction prior to mass analysis.  相似文献   

15.
A novel method is reported for rapid protein identification by the analysis of tryptic peptides using desorption electrospray ionisation (DESI) coupled with hyphenated ion mobility spectrometry and quadrupole time-of-flight mass spectrometry (IMS/Q-ToF-MS). Confident protein identification is demonstrated for the analysis of tryptically digested bovine serum albumin (BSA), with no sample pre-treatment or clean-up. Electrophoretic ion mobility separation of ions generated by DESI allowed examination of charge-state and mobility distributions for tryptic peptide mixtures. Selective interrogation of singly charged ions allowed isobaric peptide responses to be distinguished, along with a reduction in spectral noise. The mobility-selected singly charged peptide responses were presented as a pseudo-peptide mass fingerprint (p-PMF) for protein database searching. Comparative data are shown for electrospray ionisation (ESI) of the BSA digest, without sample clean-up, from which confident protein identification could not be made. Implications for the robustness of the DESI method, together with potential insights into mechanisms for DESI of proteolytic digests, are discussed.  相似文献   

16.
An on-probe pyrolyzer has been constructed and interfaced with desorption electrospray ionization (DESI) mass spectrometry (MS) for the rapid analysis of non-volatile pyrolysis products. The detection and analysis of non-volatile pyrolysis products of peptides, proteins and the synthetic polymer poly(ethylene glycol) were demonstrated with this instrument. The on-probe pyrolyzer can be operated off-line or on-line with the DESI source and was interfaced with a tandem MS (MS/MS) instrument, which allowed for structure characterization of the non-volatile pyrolytic products. Advantages of this system are its simplicity and speed of analysis since the pyrolysis is performed in situ on the DESI source probe and hence, it avoids extraction steps and/or the use of matrices (e.g., as in MALDI–MS analyses).  相似文献   

17.
A signal enhancement of two orders of magnitude was achieved when reactive desorption electrospray ionization (DESI) was used to investigate copper(II) dibutyl dithiocarbamate, Cu(II)(bu2dtc)2, found in a specialized polymer. Cu(II) was oxidized to Cu(III) during the DESI experiment by oxidants in the spray solvent. Such oxidants could be present or formed during electrospray (e.g., O2) or deliberately added to the spray solvent (this approach is called reactive DESI). When a strong oxidizing agent (e.g., iodine) was added to the spray solvent, the signal increased by two orders of magnitude relative to the pure solvent spray. The correlation between the standard reduction potential of the oxidant and the signal intensity and signal to noise ratio of the product ion for various reagents, was tested and discussed. The observed DESI enhancements in rates of oxidation are not observed in homogeneous solution. The major peaks in the collision induced dissociation (CID) spectrum of the complex ion Cu(III)(bu2dtc)2]+ were identified using isotopic distributions and MS3 data.  相似文献   

18.
An on-probe pyrolyzer has been constructed and interfaced with desorption electrospray ionization (DESI) mass spectrometry (MS) for the rapid analysis of non-volatile pyrolysis products. The detection and analysis of non-volatile pyrolysis products of peptides, proteins and the synthetic polymer poly(ethylene glycol) were demonstrated with this instrument. The on-probe pyrolyzer can be operated off-line or on-line with the DESI source and was interfaced with a tandem MS (MS/MS) instrument, which allowed for structure characterization of the non-volatile pyrolytic products. Advantages of this system are its simplicity and speed of analysis since the pyrolysis is performed in situ on the DESI source probe and hence, it avoids extraction steps and/or the use of matrices (e.g., as in MALDI–MS analyses).  相似文献   

19.
W Rao  DJ Scurr  J Burston  MR Alexander  DA Barrett 《The Analyst》2012,137(17):3946-3953
Desorption electrospray ionisation (DESI) mass spectrometry images usually contain a large amount of information that can be difficult to interpret in an objective manner. We explore the use of imaging multivariate analysis (MVA) on DESI images of protein spots and rat brain sections to automatically assign peaks and improve discrimination of spatially important features. DESI parameters were optimised on an ion trap mass spectrometer for (a) consistent imaging of dried single and mixture spots of insulin, myoglobin and BSA from a Permanox slide, and (b) to produce a MS image of rat brain coronal section at 100 μm resolution. Multivariate curve resolution (MCR), an imaging MVA technique was applied to these images after appropriate data binning. MCR analysis on DESI images of protein mixture spots allowed the multiply charged peaks of a number of proteins to be distinctly separated. Application of MCR to a DESI image of a rat brain coronal section deconvoluted the image into components that showed biologically important features. Further application of MCR to a subsection of the image produced a component that clearly separated out the substantia nigra region, which allowed us to produce a biochemical anatomy for this area of the brain. We have demonstrated the ability of imaging MVA to automatically and objectively analyse DESI images of standardised and complex biological samples, and have shown its capacity for detailed spatial profiling of biomolecules in specific morphological regions. We propose the routine use of this technique for future DESI imaging experiments.  相似文献   

20.
We report the use of fluorescence spectroscopy to investigate the amount of material removed from a PTFE surface and detected during desorption electrospray ionization (DESI) mass spectrometry measurements. The fluorescence intensity before and after DESI analysis of rhodamine 6G is used to determine the amount of material removed from the surface per mass spectrum. Calculations indicate low attomole amounts are removed per linear ion trap mass spectrum.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号