共查询到20条相似文献,搜索用时 15 毫秒
1.
Xu DH Ruan ZR Zhou Q Yuan H Jiang B 《Rapid communications in mass spectrometry : RCM》2006,20(16):2369-2375
A simple and sensitive liquid chromatography/tandem mass spectrometry method was developed and validated for determining rosuvastatin in human plasma, a new synthetic hydroxymethylglutaryl-coenzyme A reductase inhibitor. The analyte and internal standard (IS; cilostazol) were extracted by simple one-step liquid/liquid extraction with ether. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The chromatographic separation was performed on an Atlantis C18 column (2.1 mm x 150 mm, 5.0 microm) with a mobile phase consisting of 0.2% formic acid/methanol (30:70, v/v) at a flow rate of 0.20 mL/min. The analyses were carried out by multiple reaction monitoring (MRM) using the precursor-to-product combinations of m/z 482 --> 258 and m/z 370 --> 288. The areas of peaks from the analyte and the IS were used for quantification of rosuvastatin. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification (LLOQ) was 0.2 ng/mL and the assay exhibited a linear range of 0.2-50.0 ng/mL and gave a correlation coefficient (r) of 0.9991 or better. Quality control samples (0.4, 8, 25 and 40 ng/mL) in six replicates from three different runs of analysis demonstrated an intra-assay precision (RSD) 7.97-15.94%, an inter-assay precision 3.19-15.27%, and an overall accuracy (relative error) of < 3.7%. The method can be applied to pharmacokinetic or bioequivalence studies of rosuvastatin. 相似文献
2.
Xu DH Lou HG Yuan H Jiang B Zhou Q Zhang ZM Ruan ZR 《Biomedical chromatography : BMC》2008,22(4):433-440
A simple and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for determining domperidone in human plasma. The analyte and internal standard (IS; mosapride) were isolated from plasma samples by protein precipitation with methanol (containing 0.1% formic acid). The chromatographic separation was performed on an Xterra MS C(18) Column (2.1 x 150 mm, 5.0 microm) with a gradient programme mobile phase consisting of 0.1% formic acid and acetonitrile at a flow rate of 0.30 mL/min. The total run time was 4.0 min. The analyses were carried out by multiple reaction monitoring using the parent-to-daughter combinations m/z 426 --> 175 and m/z 422 --> 198 (IS). The areas of peaks from the analyte and IS were used for quantification of domperidone. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification was 0.2 ng/mL, and the assay exhibited a linear range of 0.2-60.0 ng/mL and gave a correlation coefficient (r(2)) of 0.999 or better. Quality control samples (0.4, 0.8, 15 and 50 ng/mL) in six replicates from three different analytical runs demonstrated an intra-assay precision (RSD) 4.43-6.26%, an inter-assay precision 5.25-7.45% and an overall accuracy (relative error) of <6.92%. The method can be applied to pharmacokinetic and bioequivalence studies of domperidone. 相似文献
3.
Huang Q Wang GJ Sun JG Hu XL Lu YH Zhang Q 《Rapid communications in mass spectrometry : RCM》2007,21(6):1009-1018
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for simultaneous quantification of docetaxel and ketoconazole in rat plasma with paclitaxel as internal standard (IS). The analytes were extracted from rat plasma by using a liquid-liquid extraction technique with ethyl acetate and the LC separation was performed on a Cosmosil-C(18) analytical column (150 mm x 2.0 mm i.d., Nacalai Tesque Inc., Japan). The extracted samples were analyzed with LC/MS/MS, operating in selected reaction monitoring (SRM) mode. The SRM transitions of precursor ions to product ions were 830.3-->549.1 (m/z) for docetaxel, 531.2-->489.3 (m/z) for ketoconazole, and 876.7-->307.9 (m/z) for the IS. The calibration curves were linear over the range of 2-500 ng/mL for docetaxel and 50-20 000 ng/mL for ketoconazole, with coefficients of correlation above 0.999. The limits of quantification for docetaxel and ketoconazole were both 2 ng/mL. The limit of detection for each analyte was 1 ng/mL. The intra- and inter-day precision (CV) of analysis were within 7%, and the accuracy ranged from 95 to 110%. The overall recoveries for docetaxel and ketoconazole were about 89.0% and 91.1%, respectively. The total analysis time was only 9.0 min. This quantitation method was successfully applied to the simultaneous determination of docetaxel and ketoconazole in rat plasma and some potential interaction was found in the current coadministration pharmacokinetic study. This established method was also utilized in the in vitro and in vivo drug-drug interaction study of docetaxel and ketoconazole (to be published). 相似文献
4.
Atrasentan (A-147627) is an endothelin antagonist receptor being developed at Abbott Laboratories for the treatment of prostate cancer. A quick and sensitive method for the determination of atrasentan in human plasma has been developed and validated using high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry. A dual-column, single mass spectrometer system is used to provide a reliable and routine means to increase sample throughput. The analytical method involves liquid-liquid extraction and internal standard (A-166790). The plasma samples and internal standard are acidified with 0.3 M hydrochloric acid prior to being extracted into 1:1 (v/v) hexanes--methyl t-butyl ether. The organic extract was evaporated to dryness using heated nitrogen stream and reconstituted with mobile phase. Atrasentan and internal standard were separated with no interference in a Zorbax SB-C(18) analytical column with 2.1 x 50 mm, 5 microm, and a Zorbax C(8) guard column using a mobile phase consisting of 50:50 (v:v) acetonitrile--0.05 M ammonium acetate, pH 4.5, at a flow rate of 0.30 mL/min to provide 4 min chromatograms. For a 250 microL plasma sample volume, the limit of quantitation was approximately 0.3 ng/mL. The calibration was linear from 0.30 to 98.0 ng/mL (r(2) > 0.995). A significant advantage of the method is the ability to employ parallel HPLC separations with detection by a single MS/MS system to provide sensitivity and selectivity sufficient to achieve robust analytical results with a lower limit of quantitation of 0.30 ng/mL and high throughput. 相似文献
5.
Keumhan Noh Kwang‐il Kwon Tae Cheon Jeong Wonku Kang 《Biomedical chromatography : BMC》2010,24(11):1199-1202
Sparfloxacin, a fluoroquinolone antibiotic, is used for the treatment of bacterial infection. A quantification method using mass spectrometry was developed for the determination of sparfloxacin in rat plasma. After simple protein precipitation with acetonitrile, the analytes were chromatographed on a reversed‐phase C18 column and detected by liquid chromatography/tandem mass spectrometry with electrospray ionization. The accuracy and precision of the assay were in accordance with FDA regulations for validation of bioanalytical methods. This method was applied to measure the plasma sparfloxacin concentrations after a single oral administration of sparfloxacin in rats. Copyright © 2010 John Wiley & Sons, Ltd. 相似文献
6.
Tripamide is a drug widely used in clinical practice for the treatment of hypertension and edema. This work evaluated a screening method for Tripamide and its urinary metabolites in human urine, using high-performance liquid chromatography diode-array detection (HPLC/DAD). Identification of these metabolites was investigated by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS) after dosing with 15 mg Tripamide. Acid hydrolysis showed that Tripamide is conjugated in the body. Two suspected metabolites were detected by HPLC/DAD. HPLC/ESI-MS/MS analysis suggested that these metabolites were probably hydroxylated together with loss of the -NH(2) group and dehydrogenation. These results will be useful in confirmation methods for Tripamide in doping control. 相似文献
7.
Quantitative determination of ochratoxin A by liquid chromatography/electrospray tandem mass spectrometry 总被引:2,自引:0,他引:2
Mass spectrometry of ochratoxin A (OTA) and B (OTB) under electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) was studied. ESI offers higher sensitivities and less fragmentation than APCI. A sensitive LC/MS/MS method for the determination of ochratoxin A (OTA) in human plasma samples was developed. The absolute minimum detection limit was around 10-20 pg per injection, corresponding to 0.5 ppb in an injection equivalent to 20-40microg of human plasma. Ochratoxin B (OTB) was used as an internal standard and its absence in real-life samples was carefully checked before samples were spiked with the internal standard. It was found that these two ochratoxins are susceptible to sodium adduct formation. Fragment ions from the [M + H](+) and [M + Na](+) ions of both OTA and OTB were monitored in the multiple reaction monitoring mode. Three quantitative approaches, standard addition method, internal standard method (using ochratoxin B as an internal standard) and external standard method, were compared in the analysis of human blood plasma. Results from the mass spectrometric method were comparable to those from a conventional LC/fluorescence method. The LC/MS/MS method was also applied to the analysis of contaminated coffee samples. 相似文献
8.
Delinsky DC Hill KT White CA Bartlett MG 《Rapid communications in mass spectrometry : RCM》2004,18(3):293-298
We present a method for the quantitation of motilin from rat plasma by protein precipitation and liquid chromatography/mass spectrometry (LC/MS). Using external calibration, the method was linear over the concentration range 10-1000 ng/mL with an initial sample volume of 150 microL. The LC system included a C(18) column with a 300 A pore size. A linear gradient was used with a mobile phase consisting of water and acetonitrile, each with 0.2% acetic acid and 0.02% trifluoroacetic acid. Motilin was detected with the mass spectrometer in positive ion mode monitoring the 4+ charge state at m/z 675.5. The approximated limit of detection was less than 1 ng/mL and the lower limit of quantitation (LLOQ) was 10 ng/mL. The method showed a high degree of precision and accuracy both within and between runs at five validation points, including the LLOQ. 相似文献
9.
A high-performance liquid chromatography/mass spectrometry method was developed for the determination of carnitine, its biosynthetic precursor butyrobetaine, and eight acylcarnitines in plasma. The procedure includes a solid-phase extraction for carnitine and short- and medium-chain acylcarnitines, and a liquid-liquid extraction for protein-bound long-chain acylcarnitines, followed by separation on a reversed-phase column in the presence of a volatile ion-pairing reagent. Detection was achieved using an ion-trap mass spectrometer run in the tandem mass spectrometry (MS/MS) mode. The choice of the matrix for calibrators, used for quantification of these endogenous compounds, was also investigated. Validation was performed for standard quality controls diluted with 4% bovine serum albumin solution and for spiked plasma quality control samples at concentrations between 0.5 and 80 micromol/L, depending on the compound. Intra- and inter-day precisions for the determination of carnitine were below 3.4% and accuracies were between 95.2 and 109.0%. Application of the method to the diagnosis of pathological acylcarnitine profiles of metabolic disorders in a patient suffering from methylmalonic aciduria is presented. The method allows quantification of carnitine, butyrobetaine, acetylcarnitine and propionylcarnitine, and semiquantitative analysis of medium- and long-chain acylcarnitines. In contrast with other methods, no derivatization step is needed. 相似文献
10.
Oxana Yu. Kravtsova Sergey A. Paramonov Natalya I. Vasilevich Denis N. Kazyulkin Ekaterina Vlasova Michael Engsig 《Biomedical chromatography : BMC》2013,27(12):1609-1614
A specific, sensitive, rapid and reproducible method for the determination of flomoxef in human plasma using high‐performance liquid chromatography–tandem mass spectrometry was developed and validated. Flomoxef was detected using an electrospay ionization method operated in negative‐ion mode. Chromatographic separation was performed in gradient elution mode on a Luna® C18(2) column (3 μm , 20 × 4.0 mm) at a flow rate of 1 mL/min and runtime 3.5 min. The mobile phase consisted of acetonitrile and water containing 0.1% formic acid as additive. Extraction of flomoxef from plasma and precipitation of plasma proteins was performed with acetonitrile with an absolute recovery of 86.4 ± 1.6%. The calibration curve was linear with a correlation coefficient of 0.999 over the concentration range 10–5000 ng/mL and the lower limit of quantification was 10 ng/mL. The intra‐ and inter‐day precisions were <11.8%, while the accuracy ranged from 99.6 to 109.0%. A stability study of flomoxef revealed that it could be successfully analyzed at 4ºС over 24 h, but it was unstable in solutions at room temperature during short‐term storage (4 h) and several freeze–thaw cycles. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
11.
Siethoff C Feldmann I Jakubowski N Linscheid M 《Journal of mass spectrometry : JMS》1999,34(4):421-426
The quantitative determination of nucleotides from DNA modified by styrene oxide is described using a combination of inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) and electrospray ionization mass spectrometry (ESI-MS), both interfaced to reversed-phase high-performance liquid chromatography (HPLC). LC/ICP-MS (resolution > 1500 to discriminate against 15N16O+ and 14N16OH+) was employed to determine quantitatively the content of modified nucleotides in standard solutions based on the signal of phosphorus; phosphoric acid served as an internal standard. By means of the standard addition technique the sensitivity of the LC/ESI-MS approach was subsequently determined. Since a comparison of UV, ICP and ESI-MS data suggested that in ESI-MS the ionization efficiency of the adducts is identical within the error limits, quantitative determination of all adducts is possible. For LC/ESI-MS with single ion monitoring, the detection limit for styrene oxide adducts of nucleotides was determined to be 20 pg absolute or 14 modified in 10(8) unmodified nucleotides in a 5 micrograms DNA sample, which comes close to the best methods available for the detection of chemical modifications in DNA. 相似文献
12.
13.
Santa T 《Biomedical chromatography : BMC》2011,25(1-2):1-10
Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds. 相似文献
14.
Aldini G Orioli M Carini M Maffei Facino R 《Journal of mass spectrometry : JMS》2004,39(12):1417-1428
The histidine-containing dipeptides carnosine (CAR) and structurally related anserine (ANS) and homocarnosine (HCAR), widely distributed in vertebrate organisms, have recently been proposed as endogenous quenchers for highly cytotoxic alpha,beta-unsaturated aldehydes generated by peroxidation. A sensitive, selective, specific and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric assay was developed and validated for the simultaneous determination of these peptides in biological matrices in order to establish their plasma/tissue distribution. Samples (plasma or tissue homogenates from male rats) were prepared by protein precipitation with HClO(4) (1 : 1, v/v) containing H-Tyr-His-OH as internal standard. The supernatant was separated on a Phenomenex Sinergy polar-RP column with a mobile phase of water-acetonitrile-heptafluorobutyric acid (9 : 1 : 0.01, v/v/v) at a flow-rate of 0.2 ml min(-1), with a run time of 10 min. Detection was effected on an ion trap mass spectrometer equipped with an electrospray ionization interface operating in positive ionization mode. The acquisitions were in the multiple reaction monitoring mode using the following precursor --> product ion combinations: H-Tyr-His-OH (internal standard) m/z 319 --> 301; CAR m/z 227 --> 210 + 209; ANS m/z 241 --> 224 + 197 + 170; HCAR m/z 241 --> 156. The method was validated over the concentration range 15-1000 nmol g(-1) and the limit of quantification (LOQ) and limit of detection (LOD) were 12.5 and 4.2 pmol injected, respectively. The intra- and inter-day precisions were <10% (< or =17.47% at the LOQ) and the intra- and inter-assay accuracies were within +/-10% for all concentrations. The mapping profile in rat tissue gave the following results: the highest concentrations of CAR and ANS were found in skeletal muscles (soleus, gastrocnemius, tibialis), followed by the heart, cerebellum and brain (ANS below the LOQ). HCAR was found only in the brain and cerebellum. No histidine-containing dipeptides were detectable in plasma, liver, kidney and lung. 相似文献
15.
Croubels S Cherlet M De Backer P 《Rapid communications in mass spectrometry : RCM》2002,16(15):1463-1469
A novel, sensitive and specific method for the quantitative determination of diclazuril in animal plasma using liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) with negative ion detection is presented. Extraction of the samples was performed with a rapid deproteinization step using acetonitrile. Chromatography of diclazuril and the internal standard was achieved on a Nucleosil ODS 5-microm column, using a gradient elution with 0.01 M ammonium acetate and acetonitrile. To obtain the highest sensitivity and specificity possible, the mass spectrometer was operated in the multiple reaction monitoring (MRM) mode. The method was validated according to the requirements defined by the European Community. Calibration curves using plasma fortified between 1-100 ng/mL and 100-2000 ng/mL showed good linear correlation (r >or= 0.9991, goodness-of-fit coefficient 相似文献
16.
A fast and sensitive ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed for the determination of lovastatin in human plasma. With simvastatin as internal standard, sample pretreatment involved one-step extraction with n-hexane-methylene dichloride-isopropanol (20:10:1, v/v/v) of 0.5 mL plasma. Chromatographic separation was carried out on an Acquity UPLC BEH C(18) column with mobile phase consisting of acetonitrile-water (containing 5 mmol/L ammonium acetate; 85:15, v/v) at a flow-rate of 0.35 mL/min. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) via electrospray ionization source with positive mode. The analysis time was shorter than 1.7 min per sample. The standard curve was linear (r2>or=0.99) over the concentration range 0.025-50.0 ng/mL with a lower limit of quantification of 0.025 ng/mL. The intra- and inter-day precision values were below 11% and the accuracy (relative error) was within 6.0% at three quality control levels. This is the first method of MS with MRM coupled to UPLC for the determination of lovastatin, which showed great advantages of high sensitivity, selectivity and high sample throughput. It was fully validated and successfully applied to the pharmacokinetic study of lovastatin tablets in healthy Chinese male volunteers after oral administration. 相似文献
17.
Quantitative determination of ginsenoside Rh2 in rat biosamples by liquid chromatography electrospray ionization mass spectrometry 总被引:2,自引:0,他引:2
Gu Y Wang GJ Sun JG Jia YW Xie HT Wang W 《Analytical and bioanalytical chemistry》2006,386(7-8):2043-2053
Ginsenoside Rh2 is a “hot” natural compound with great potential as a new anti-cancer drug based on abundant pharmacological experiments.
However, no systemic pharmacokinetic study of Rh2 was reported because current analysis methods could not fully meet the requirements. Thus, we developed a simple LC/MS method
with highly improved sensitivities for the determination of Rh2 in rat plasma, bile, urine, feces and most tissues. The tissues and feces were firstly homogenized mechanically using buffer
and methanol as the media, respectively. Plasma, bile, urine and tissue homogenates were extracted with diethyl ether for
sample preparation. Feces homogenates were directly deproteinized with acetonitrile. The subsequent analysis procedures were
performed on a Shimadzu LCMS2010A system (electrospray ionization single quadrupole mass analyzer), with an ODS column (150 mm × 2.0-mm
i.d., 5 μm) plus a C18 guard column for separation and ammonium chloride (500 μmol) as mobile phase additive. The proportions
of mobile phase were changed timely according to gradient programs. Chlorinated adducts of molecular ions [M + Cl]− of Rh2 at m/z 657.35 and internal standard digitoxin at m/z 799.55 were monitored in selective ion monitoring mode of negative ions. The method was validated to be accurate, precise
and rugged with good linearity in all matrices, according to the FDA guidelines. The lower limits of quantitation in rat plasma,
urine and feces were 0.2, 0.2 and 20 ng/mL respectively. Stability studies were also performed, indicating that there were
no stability-related problems in the analytical procedure of Rh2. The proposed method was successfully applied to the preclinical pharmacokinetic research of Rh2 in rats, including plasma kinetics, tissue distribution and excretion studies. 相似文献
18.
Roberta Zangrando Silvia De Pieri Jacopo Gabrieli Elena Barbaro Carlo Barbante 《International journal of environmental analytical chemistry》2013,93(10):1150-1160
A method has been developed for the determination of acrylamide at the picogram per cubic metre level in particulate-phase outdoor aerosol using high-performance liquid chromatography with triple quadrupole tandem mass spectrometric detection. Acrylamide was identified by positive ion electrospray mass spectrometry using m/z 72.00/54.90 as monitoring ion transition. The limit of detection, defined as three times the standard deviation of the procedural blanks, was 0.4?pg?m?3 (173?pg absolute amount injected); the repeatability was 8% (evaluated as the relative standard deviation of five consecutive measurements on cleaned quartz fibre filters of acrylamide standard spikes) and the recovery was 52?±?4%. The accuracy of the method (evaluated as relative error) has been estimated to be ?2%. This methodology was used to determine acrylamide concentrations in particulate-phase outdoor aerosol in the Venice Lagoon with concentrations ranging between 0.4 and 12.9?pg?m?3 with an average value of 3.1?pg?m?3. 相似文献
19.
An uroporphomethene inhibitor of uroporphyrinogen decarboxylase, characterized by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry, was reported recently (Phillips et al., Proceedings of the National Academy of Sciences of the United States of America 2007; 104: 5079-5084). Close examination of the tandem mass spectrometric fragmentation pattern of the compound showed that it is not a tetrapyrrole or an uroporphyrinogen or uroporphyrin related molecule. The product ion spectrum showed a fragmentation pattern typical of a poly(ethylene glycol) structure. Characteristic fragmentations of the side-chain acetic acid and propionic acid substituents of a uroporphyrin or uroporphyrinogen derivative were absent. 相似文献
20.
BMS-378806 is a human immunodeficiency virus (HIV) entry inhibitor that is being developed for the oral treatment of HIV infection. Human plasma and urine LC/MS/ MS methods have been developed and validated for the quantitation of BMS-378806. For human plasma method, methyl t-butyl ether was used to extract BMS-378806 from plasma in a 96-well format, and the organic layers were dried down and then reconstituted for the injection, while a dilute-and-shoot approach was used for human urine method in a 96-well format. Chromatographic separation was achieved isocratically on a Phenomenex C18 (2) Luna column (2 x 50 mm2, 5 microm). The mobile phase contained 60:40 v/v of 0.1% formic acid in water and ACN. Detection was by positive ion electrospray MS/MS. The standard curves ranged from 1.25 to 1000 ng/mL for the plasma assay and from 10 to 5000 ng/mL for the urine assay. The curves were fitted to a 1/x2 weighted quadratic regression model for both methods. The validation results demonstrated that both methods had satisfactory precision and accuracy across the calibration ranges. The methods were applied to the analysis of human plasma and urine samples from a single ascending dose clinical study to assess the pharmacokinetics of the drug. The pharmacokinetic analysis results indicated the absorption and disposition of the drug was rapid. The systemic exposure of BMS-378806 was generally dose proportional among the doses from 100 to 1200 mg, but not dose proportional to 1600 mg. There were modest increases in the systemic exposure when the drug was given with food or given as a solution formulation. Renal excretion was not a substantial elimination pathway of the drug. BMS378806 was safe and well tolerated over a dose range of 100-1600 mg administered as a single oral dose. 相似文献