首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 671 毫秒
1.
Dinç E  Baleanu D 《Talanta》2003,59(4):707-717
A new graphical method based on the one-dimensional wavelet transform (WT) was proposed and tested on mixture of thiamine hydrochloride (THI) and pyridoxine hydrochloride (PYR) in the presence of strongly overlapping signals. We selected from the data of the UV-VIS absorption spectra a signal consisting of 1150 points corresponding to the concentration range 8-32 mg ml−1 for each vitamin and we subjected it to Daubechies8 (DAUB8) and Biorthogonal6.8 (BIOR6.8) wavelet transforms. Since the peaks of the transformed signals were bigger than original ones a zero crossing method was applied to obtain the calibration graphs. In addition, the validity of Beer-Lambert law was assumed for the transformed signals. An appropriate scale setting was choosing to obtain an alternative calibration for each method. Matlab 6.5 software was used for one-dimensional wavelet analysis and the basic concepts about wavelet method were given. The obtained results were successfully compared among each other as well as with those obtained by other literature methods. The method developed in this paper is rapid, easy to apply, not expensive and it is suitable for analyzing of the overlapping signals of compounds in their mixtures without any chemical pre-treatment.  相似文献   

2.
In this work, a combined discrete and continuous wavelet transform analysis was developed for simultaneous spectrophotometric determinations of metformin hydrochloride and glibenclamide, two antidiabetic drugs, in binary mixtures without any chemical pretreatment. Absorption spectra were subjected to the 4-level db4 discrete wavelet transform (DWT) for signal de-noising. Selected continuous wavelet transform (CWT) families (rbio3.1 with scaling factor, a = 80, and gaus2, a = 60) were applied on these de-noised signals. Finally, a zero-crossing technique was used for the construction of calibration curves for both drugs. The proposed method was validated by analyzing synthetic mixtures of the investigated drugs with various concentrations. The amount of metformin hydrochloride and glibenclamide were determined by using CWT amplitudes in zero-crossing points. The mean recovery values of metformin hydrochloride and glibenclamide were found between 98.6-102.0 and 97.9-102.4% for rbio3 and 98.3-101.2 and 97.1-101.4% for gaus2 families, respectively. The obtained results showed that the developed method is a simple, rapid and precise procedure for the simultaneous determination of metformin hydrochloride and glibenclamide in binary mixtures.  相似文献   

3.
The discrete and continuous wavelet transforms were applied to the overlapping signal analysis of the ratio data signal for simultaneous quantitative determination of the title subject compounds in samples. The ratio spectra data of the binary mixtures containing benazepril (BE) and hydrochlorothiazide (HCT) were transferred as data vectors into the wavelet domain. Signal compression, followed by a 1-dimension continuous wavelet transform (CWT), was used to obtain coincident transformed signals for pure BE and HCT and their mixtures. The coincident transformed amplitudes corresponding to both maximum and minimum points allowed construction of calibration graphs for each compound in the binary mixture. The validity of CWT calibrations was tested by analyzing synthetic mixtures of the investigated compounds, and successful results were obtained. All calculations were performed within EXCEL, C++, and MATLAB6.5 softwares. The obtained results indicated that our approach was flexible and applicable for the binary mixture analysis.  相似文献   

4.
New chemometric approaches based on the application of partial least squares (PLS) and principal component regression (PCR) algorithms with fractional wavelet transform (FWT) and continuous wavelet transform (CWT) are proposed for the spectrophotometric multicomponent determination of thiamine hydrochloride (B1), pyridoxine hydrochloride (B6), and lidocaine hydrochloride (LID) in ampules without any separation step. In this study PLS and PCR techniques were applied to the raw spectral data, FWT-coefficients, and FWT-CWT-coefficients. These calibration models were labeled as Raw-PLS and Raw-PCR, FWT-PLS and FWT-PCR, and FWT-CWT-PLS and FWT-CWT-PCR, respectively. A new ultra-performance liquid chromatographic (UPLC) method was developed for the comparison of the results obtained by applying the chemometric calibration methods. Chromatographic separation and determination of B1, B6, and LID in ampules were performed on an Acquity UPLC BEH C18 column (50x2.1 mm id, 1.7 pm particle size) using gradient elution with a mobile phase consisting of methanol and 0.01 M HCI at a constant flow rate of 0.6 mL/min. These combined chemometric calibrations and UPLC were validated by analyzing various ternary mixtures, B1, B6, and LID. The proposed chemometric approaches (signal processing-multivariate calibrations) and UPLC method were applied to the quantitative multicomponent analysis of marketed ampules containing the vitamins B1 and B6 with LID.  相似文献   

5.
By theoretical analysis, it is found that wavelet transform (WT) with a wavelet function can be regarded as a smoothing and a differentiation process, and that the order of differentiation is determined by the vanishing moment, which is an important property of a wavelet function. Therefore, a method based on the continuous wavelet transform (CWT) for removing the background in the near-infrared (NIR) spectrum is proposed, and it is used in the determination of the chlorogenic acid in plant samples as a preprocessing tool for partial least square (PLS) modeling. It is shown that the benefit of the proposed method lies not only in its performance to improve the quality of PLS model and the prediction precision, but also in its simplicity and practicability. It may become a convenient and efficient tool for preprocessing NIR spectral data sets in multivariate calibration.  相似文献   

6.
A new application of continuous wavelet transform (CWT) to overlapping peaks in a chromatogram was developed for the quantitative analysis of amiloride hydrochloride (AML) and hydrochlorothiazide (HCT) in tablets. Chromatographic analysis was done by using an ACQUITY ultra-performance LC (UPLC) BEH C18 column (50 x 2.1 mm id, 1.7 pm particle size) and a mobile phase consisting of methanol-0.1 M acetic acid (21 + 79, v/v) at a constant flow rate of 0.3 mL/min with diode array detection at 274 nm. The overlapping chromatographic peaks of the calibration set consisting of AML and HCT mixtures were recorded rapidly by using an ACQUITY UPLC H-Class system. The overlapping UPLC data vectors of AML and HCT drugs and their samples were processed by CWT signal processing methods. The calibration graphs for AML and HCT were computed from the relationship between concentration and areas of chromatographic CWT peaks. The applicability and validity of the improved UPLC-CWT approaches were confirmed by recovery studies and the standard addition technique. The proposed UPLC-CWT methods were applied to the determination of AML and HCT in tablets. The experimental results indicated that the suggested UPLC-CWT signal processing provides accurate and precise results for industrial QC and quantitative evaluation of AML-HCT tablets.  相似文献   

7.
Three simple, rapid, and accurate methods, i.e., the derivative ratio spectra-zero-crossing method (method I), double divisor-ratio spectra derivative method (method II), and column reversed-phase high-performance liquid chromatographic (RP-HPLC) method (method III) were developed for the simultaneous determination of doxylamine succinate (DOX), pyridoxine hydrochloride (PYR), and folic acid (FA) in their ternary mixtures and in tablets. In methods I and II, the calibration graphs were linear in the range of 2.5-80, 1.0-40, and 1.0-30 microg/mL for DOX, PYR, and FA, respectively. In the HPLC method, the separation of these compounds was performed using mobile phase consisting of 0.05 M phosphate buffer (pH 6.3)-methanol-acetonitrile (50 + 20 + 30, v/v/v), and UV detection was performed at 263 nm. Linearity was observed between the concentrations of the analytes and peak areas [correlation coefficient (r) > or =0.9998] in the concentration range of 1.0-200, 4.0-600, and 4.0-600 microg/mL for DOX, PYR, and FA, respectively. The standard deviation of retention time in method III was 0.011, 0.015, and 0.016 for DOX, PYR, and FA, respectively. The precision studies for all of the methods gave relative standard deviation values of <2%. The results obtained from the methods were statistically compared by means of Student's t-test and the variance ratio F-test. It was concluded that all of the developed methods were equally accurate, sensitive, and precise. These methods could be applied to determine DOX, PYR, and FA in their combined dosage forms.  相似文献   

8.
Cyclizine hydrochloride (CYC) and meclozine hydrochloride (MEC) are antihistaminic drugs generally co-formulated with pyridoxine hydrochloride (PYR) to treat nausea and vomiting in pregnancy. Several analytical techniques have been applied for the determination of CYC or MEC with PYR, but determination of CYC impurity; benzhydrol (BEH) or MEC impurity; or 4-chlorobenzophenone (BEP) has not been paid attention to. Therefore, micellar UPLC method is introduced for analysis of ternary mixtures containing PYR together with both CYC and BEH (mixture I) or MEC and BEP (mixture II). Chromatographic separation was achieved using a Hypersil gold C8 column (50 × 2.1 mm, 1.9 μm) using 0.01 M sodium dodecyl sulfate modified to pH 3.5 using phosphoric acid:acetonitrile (45:55 by volume) for mixture I and 0.1% sodium dodecyl sulfate, 0.1% sodium bicarbonate adjusted to pH 2.6 by phosphoric acid:acetonitrile (47:53 by volume) for mixture II as mobile phases. The separated peaks were detected at 230 and 245 nm for mixtures I and II, respectively. The adopted methods were validated in conformance with the International Conference on Harmonization (ICH) recommendations and were properly applied in commercial pharmaceutical formulation analysis. Comprehensive ecological comparison was achieved, confirming a higher ecological value of the presented methods compared to the earlier reported methods.  相似文献   

9.
Fractional wavelet transform (FWT) was applied to the original absorption spectra of lacidipine (LAC) and its photodegradation product (LACD), and the resulting FWT spectra were processed by continuous wavelet transform (CWT) and multilinear regression calibration (MLRC) for the simultaneous quantitative analysis of both products in their binary mixtures. These methods do not require any chemical separation step and chemical complex reaction to obtain a detectable signal for the degradation product. By using the Mexican hat function, 2 calibration functions for LAC and LACD were obtained by measuring the CWT transformed signals at 416.1 nm for LAC and 414.6 nm for LACD, after FWT processing of the original absorption spectra. The calibration graphs were linear in the concentration range of 5.08-40.64 microg/mL for LAC and 0.51-8.16 microg/mL for LACD. The limit of detection and the limit of quantitation were found to be 0.289 and 0.956 microg/mL for LAC and 0.036 and 0.118 microg/mL for LACD, respectively. For comparison, the MLRC algorithm was applied to the linear regression functions for the individual drug and its photoproduct. In this approach, a set of linear regression functions was obtained from the relationship between concentrations and FWT signals in the wavelength range 411.0-412.4 nm. Both methods were applied to the quantitative evaluation of LAC and LACD in laboratory and pharmaceutical samples, and produced very satisfactory results.  相似文献   

10.
Orthogonal WAVElet correction (OWAVEC) is a pre-processing method aimed at simultaneously accomplishing two essential needs in multivariate calibration, signal correction and data compression, by combining the application of an orthogonal signal correction algorithm to remove information unrelated to a certain response with the great potential that wavelet analysis has shown for signal processing. In the previous version of the OWAVEC method, once the wavelet coefficients matrix had been computed from NIR spectra and deflated from irrelevant information in the orthogonalization step, effective data compression was achieved by selecting those largest correlation/variance wavelet coefficients serving as the basis for the development of a reliable regression model. This paper presents an evolution of the OWAVEC method, maintaining the first two stages in its application procedure (wavelet signal decomposition and direct orthogonalization) intact but incorporating genetic algorithms as a wavelet coefficients selection method to perform data compression and to improve the quality of the regression models developed later. Several specific applications dealing with diverse NIR regression problems are analyzed to evaluate the actual performance of the new OWAVEC method. Results provided by OWAVEC are also compared with those obtained with original data and with other orthogonal signal correction methods.  相似文献   

11.
An algorithm is proposed for extracting relevant information from near-infrared (NIR) spectra for multivariate calibration of routine components in complex plant samples. The algorithm is a combination of wavelet transform (WT) data compression and a procedure for uninformative variable elimination (UVE). After compression of the NIR spectra by WT, the UVE approach is used to eliminate the irrelevant wavelet coefficients. Finally, a calibration model is built from the retained wavelet coefficients to enable prediction. Because irrelevant information can be removed from the spectra used for multivariate calibration, the model based on the extracted relevant features is better than those obtained with full-spectrum data. Both prediction precision and calculation speed are improved.  相似文献   

12.
基于小波变换平滑主成分分析   总被引:3,自引:0,他引:3  
小波变换具有很强的信号分离能力,很容易把随机噪音从信号中分离出来,从而提高信号的信噪比。本文把小波变换引入到因子分析中,提出了基于小波变换平滑主成分分析,该算法既保留普通主成分分析的正交分解,又具备了小波变换的信号分离能力。模拟数据和实验数据的结果表明,该算法具有从低信噪比的数据中提取出有用信息,并提高信号的信噪比。迭代目标变换因子分析处理实验数据的结果表明,基于小波变换平滑主成分分析的处理结果优  相似文献   

13.
A new application of the fractional wavelet transform (FWT) was proposed for the simultaneous determination of ampicillin (AP) and sulbactam (SB) in a pharmaceutical combination for injection. FWT approach is a new powerful tool for removing noise and irrelevant information from the absorption spectra. Cardinal information having higher peak amplitude, eliminated noise, sharp peaks with shrinking width of spectral range was obtained by the application of FWT procedure to the original absorption spectra. In this paper, FWT approach was subjected to the data vector of the UV-signals obtained from AP and SB in the wavelength range of 211.5-313.8 nm. Derivative transform was applied to the original absorption signal together with its FWT generalization. The calibration graphs for AP and SB were obtained by measuring the FWT and usual derivative amplitudes at zero-crossing points. The method validation was carried out by using the synthetic mixture analysis. Our proposed FWT approach was compared with the usual derivative spectrophotometry and chemometric methods (CLS, PCR and PLS) and a good agreement was reported.  相似文献   

14.
Da C  Wang F  Shao X  Su Q 《The Analyst》2003,128(9):1200-1203
A new hybrid algorithm is proposed to eliminate the interference information for multivariate calibration of near-infrared (NIR) spectra that includes noise, background and systemic spectral variation irrelevant to concentration. The method consists of two parts: approximate derivative based on continuous wavelet transform (CWT) and orthogonal signal correction (OSC). After the approximate derivative calculated by CWT, OSC was performed. It was successfully applied to real complex NIR spectral data to eliminate the interference information. Correction for the interference of NIR spectra resulted in a substantial improvement in the predicted precision, and a more concise calibration model was obtained. The proposed procedure also compared favourably with several pretreatment methods, and the new method appears to provide a high-performance pretreatment tool for multivariate calibration of NIR spectra. In addition, the strategy proposed here can be applied to various other spectral data for quantitative purposes as well.  相似文献   

15.
比值导数波谱法用于极谱及伏安法多组分分析   总被引:2,自引:0,他引:2  
倪永年  金玲 《分析化学》1998,26(2):180-183
叙述了比值导数波谱法在电化学波谱解析中应用的原理。首先以混合物的极谱波(或伏安波)除以干扰组分的标准波谱得到比值波谱,再以比值波谱对电位求导得到比值导数波谱,藉此可消除干扰组分的影响。采用该法可对二组分体系进行分析,如选择合适的零交点便可对三组分体系进行分析。利用本法对苋菜红-日落黄的伏安波及铜-镉-镍的极谱波进行了解析及定量分析,获较好的结果。  相似文献   

16.
根据市售鼠药样品成分各异且相对复杂,建立6种不同成分体系和9个不同样本容量的校正集,运用小波变换压缩鼠药的近红外透射光谱数据,结合BP反向神经网络算法对压缩的数据进行建模,考察校正集样品特性对模型预测能力的影响。试验结果表明:采用BP神经网络算法建立定量模型时,只要校正集样品中包含了与预测样品性质相似的样本,就能准确地对复杂样品进行近红外定量分析。当校正集容量分别为72和84时,模型预测结果趋于平稳。当校正集数量为96时,模型的最大相关系数为0.959 8,预测最小标准差和平均相对误差分别为1.893%和1.92%。  相似文献   

17.
Glycerol monolaurate (GML) products contain many impurities, such as lauric acid and glucerol. The GML content is an important quality indicator for GML production. A hybrid variable selection algorithm, which is a combination of wavelet transform (WT) technology and modified uninformative variable eliminate (MUVE) method, was proposed to extract useful information from Fourier transform infrared (FT-IR) transmission spectroscopy for the determination of GML content. FT-IR spectra data were compressed by WT first; the irrelevant variables in the compressed wavelet coefficients were eliminated by MUVE. In the MUVE process, simulated annealing (SA) algorithm was employed to search the optimal cutoff threshold. After the WT-MUVE process, variables for the calibration model were reduced from 7366 to 163. Finally, the retained variables were employed as inputs of partial least squares (PLS) model to build the calibration model. For the prediction set, the correlation coefficient (r) of 0.9910 and root mean square error of prediction (RMSEP) of 4.8617 were obtained. The prediction result was better than the PLS model with full-spectra data. It was indicated that proposed WT-MUVE method could not only make the prediction more accurate, but also make the calibration model more parsimonious. Furthermore, the reconstructed spectra represented the projection of the selected wavelet coefficients into the original domain, affording the chemical interpretation of the predicted results. It is concluded that the FT-IR transmission spectroscopy technique with the proposed method is promising for the fast detection of GML content.  相似文献   

18.
Zhang M  Cai W  Shao X 《The Analyst》2011,136(20):4217-4221
Continuous wavelet transform (CWT) has been shown to be a high-performance signal processing technique in multivariate calibration. However, the signal processed by CWT with a specific wavelet may account for only a part of the information. To effectively utilize more abundant information contained in analytical signals, a method, named as wavelet unfolded partial least squares (WUPLS), was proposed. In the approach, the measured dataset is firstly extended by CWT with different wavelets, and then partial least squares (PLS) is employed to develop the quantitative model between the extended dataset and the target values. In order to select the representative wavelets, principal component analysis (PCA) is used to investigate the distribution of the signals obtained by CWT with different wavelets. The performance of the method was tested with blood and tobacco powder samples. Compared with the results obtained by PLS methods, the WUPLS method combined with signal processing techniques is proven to be a promising tool for improving the near-infrared (NIR) spectral analysis of complex samples.  相似文献   

19.
将小波变换和多维偏最小二乘法相结合用于近红外光谱定量校正模型的建立。首先将原始光谱进行小波变换分解,得到系列小波细节系数,通过选取一组受外界因素少、信息强的小波系数组成三维光谱阵,然后再采用多维偏最小二乘法建立校正模型。实验结果表明,该方法所建近红外校正模捌的预测能力更强,并更具稳健性。  相似文献   

20.
Simultaneous determination of binary mixtures pyridoxine hydrochloride and thiamine hydrochloride in a vitamin combination using UV-visible spectrophotometry and classical least squares (CLS) and three newly developed genetic algorithm (GA) based multivariate calibration methods was demonstrated. The three genetic multivariate calibration methods are Genetic Classical Least Squares (GCLS), Genetic Inverse Least Squares (GILS) and Genetic Regression (GR). The sample data set contains the UV-visible spectra of 30 synthetic mixtures (8 to 40 microg/ml) of these vitamins and 10 tablets containing 250 mg from each vitamin. The spectra cover the range from 200 to 330 nm in 0.1 nm intervals. Several calibration models were built with the four methods for the two components. Overall, the standard error of calibration (SEC) and the standard error of prediction (SEP) for the synthetic data were in the range of <0.01 and 0.43 microg/ml for all the four methods. The SEP values for the tablets were in the range of 2.91 and 11.51 mg/tablets. A comparison of genetic algorithm selected wavelengths for each component using GR method was also included.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号