共查询到20条相似文献,搜索用时 15 毫秒
1.
The paper presents an on-line transient moving chemical reaction boundary (MCRB) method for simply but efficiently stacking analytes in capillary electrophoresis (CE). The CE technique was developed for a rapid determination of fumaric and maleic acid. Based on the theory of MCRB, Effects of several important factors such as the pH and concentration of running buffer and the conditions of stacking analytes were investigated to acquire the optimum conditions. The optimized separations were carried out in a 20 mmol/L sulphate neutralized with ethylenediamine to pH 6.0 electrolytes using a capillary coated with poly (diallyldimethylammonium chloride) and direct UV detection at 214 nm. The optimized preconcentrations were carried out in 50 mmol/L borax (pH 9.0). The calibration curves were linear in the concentration range of 1.0 × 10−7–1.0 × 10−4 mol/L and 5.0 × 10−7–1.0 × 10−4 mol/L for fumaric and maleic acid with correlation coefficients higher than 0.9991. The detection limits were 5.34 × 10−8 mol/L for fumaric acid and 1.92 × 10−7 mol/L for maleic acid. This method was applied for determination of fumaric acid in apple juice and of fumaric and maleic acid in dl-malic, the recovery tests established for real samples were within the range 95–105%. This work provided a valid and simple approach to detect fumaric and maleic acid. 相似文献
2.
A quantitative method of capillary electrophoresis with sample stacking induced by moving reaction boundary (MRB) was developed for sensitive determination of oxymatrine (OMT) and matrine (MT) in rat plasma. The experimental conditions were optimized firstly. Below are the optimized experimental conditions: 20 mM sodium formate solution (HCOONa, adjusted to pH 10.70 by ammonia) as sample solution, 3 min 14 mbar sample injection, 40 mM formic buffer (HCOOH-HCOONa, pH 2.60) as stacking buffer, 7 min 14 mbar injection of stacking buffer, 100 mM HCOOH-HCOONa (pH 4.80) as separation buffer, 73 cm capillary (effective length 64 cm), 21 kV voltage, 210 nm wavelength. Under the optimized conditions, higher than 60-fold sensitivity improvement of the stacking was simply achieved as compared with capillary zone electrophoresis, and the detectable limits obtained for OMT and MT were 0.26 and 0.19 μg mL−1, respectively. Then, numerous demonstrations were carefully performed for the methodological validations of OMT and MT in rate plasma, including high specificity of method, good linearity (r = 0.9993 for OMT, r = 0.9991 for MT), fair wide linear concentration range (1.30-65.00 μg mL−1 for OMT, 0.84-42.00 μg mL−1 for MT), low limit of detection (1.03 μg mL−1 for OMT, 0.38 μg mL−1 for MT), less than 5% intra- and inter-day variance value, and higher than 96% recovery of OMT and MT in plasma. The developed method could be used for the trace analyses of OMT and MT in plasma and was finally used for the investigation on pharmacokinetic study of OMT in rat plasma. 相似文献
3.
The reason why a moving reaction boundary (MRB) can stack analyte in highly saline sample in capillary electrophoresis [C.X. Cao, Y.Z. He, M. Li, Y.T. Qian, S.L. Zhou, L. Yang, Q.S. Qu, Anal. Chem. 74 (2002) 4167] is still unclear. To illuminate the mechanism of such stacking, three MRBs formed by formic acid-NaOH buffer and sodium formate as well as 40, 80 and 120 mmol/L sodium chloride in matrixes were studied. The computation with MRB theory shows that sodium chloride in matrix has weak effect on the stacking efficiency, whether the concentration of sodium chloride is set at 40, or 80, or 120 mmol/L. The conclusion has been highly manifested by numerous experiments. Furthermore, the computer simulation and theoretical analyses depict that this kind of stacking is induced by the mechanism of MRB, rather than that of electrostacking or isotachophoresis (ITP) under the given electrolytic system. Finally, the application of the sample condensation was achieved for the stacking of analyte(s) in highly saline biological sample of skeletonema costarum’ culture with up to 527 mmol/L total salt and health human urine with 150-320 mmol/L inorganic ions (Cl−, Na+, K+, PO43−, etc.). The results herein have a clear significance to the design on stacking of analyte in highly saline biological sample. 相似文献
4.
The condensation of low abundance zwitterion substance, such as protein and peptide, has great significance to the study on proteomics. This paper develops the theory on design of online stacking conditions of zwitterion by a moving reaction boundary (MRB) in capillary electrophoresis (CE). This concerns the choice of running and sample buffers, velocity design of MRB, and salt effect on the stacking. The theoretical results unveil that: (1) the velocity of MRB formed with weak acidic buffer and strong alkali should be set between zero and the velocity of zwitterion in the alkali phase, or no stacking occurs; (2) if a strong alkali is used to prepare the sample, a much long front plug of strong base must be injected before the alkaline sample plug for complete stacking, whereas no such front plug is needed if a weak alkali with enough high concentration and pH value is used to prepare the sample buffer; (3) the existence of salt in sample matrix has a weak effect on the stacking of zwitterion if sample is prepared with weak alkaline buffer, while has a dramatic effect on the same stacking if with a strong base buffer. In addition, the concentration of weak alkali used for preparation of sample should be set at the point, at which the velocity of MRB is as much as possible close to that of negative zwitterion. The developed theory and its computation are quantitatively proved by the experiments of zwitterion stacking by the MRB as shown in the previous and the accompanying papers. The proposed theoretic results hold obvious significances on-column stacking of low abundance zwitterions, such as amino acid, or peptides or proteins, in CE. 相似文献
5.
To demonstrate the theoretic method on the stacking of zwitterion with moving reaction boundary (MRB) in the accompanying paper, the relevant experiments were performed. The experimental results quantitatively show that (1) MRB velocity, including the comparisons between MRB and zwitterionic velocities, possesses key importance to the design of MRB stacking; (2) a much long front alkaline plug without sample should be injected before the sample injection for a complete stacking of zwitterion if sample buffer is prepared with strong base, conversely no such plug is needed if using a weak base as the sample buffer with proper concentration and pH value; (3) the presence of salt in MRB system holds dramatic effect on the MRB stacking if sample solution is a strong base, but has no effect if a weak alkali is used as sample solution; (4) all of the experiments of this paper, including the previous work, quantitatively manifest the theory and predictions shown in the accompanying paper. In addition, the so-called derivative MRB-induced re-stacking and transient FASI-induced re-stacking were also observed during the experiments, and the relevant mechanisms were briefly demonstrated with the results. The theory and its calculation procedures developed in the accompanying paper can be well used for the predictions to the MRB stacking of zwitterion in CE. 相似文献
6.
高效毛细管区带电泳法快速测定尿液中的肌酐 总被引:1,自引:0,他引:1
建立了一种快速测定尿中肌酐浓度的高效毛细管电泳方法。利用非涂层石英毛细管(64.5 cm×50μm i.d),以pH 2.5,0.1 mmol/L H3PO4作为电泳缓冲液,检测波长191 nm,用0.05 Pa压力进样4 s,在电压16 kV快速分离尿液中的肌酐,采用外标法定量。肌酐的迁移时间约为5.5 min,肌酐浓度在34.5~8840μmol/L范围内呈良好的线性(r2=0.999)。平均日内精密度为2.5%,日间精密度为3.0%。回收率94.1%~99.0%。与全自动生化分析仪碱性苦味酸速率法相比有良好的相关性(r=0.990,n=56)。高效毛细管电泳法测定尿肌酐可应用于临床样品的检测。 相似文献
7.
Jie Jin Jing ShaoSi Li Wei ZhangLiu-Yin Fan Cheng-Xi Cao 《Journal of chromatography. A》2009,1216(24):4913-4922
This paper introduces a mathematic mode of moving chelation boundary (MCB) for computer simulation of a continuous EDTA-based sample sweeping in capillary electrophoresis (CE). Besides the equations of MCB used herein, the mode also includes electro-neutrality equation, constant current density, jump boundary condition of MCB, Kohlrausch’ regulating function expressed in MCB formulation, product of water, ionic apparent mobility, ionic strength and conductivity of electrolyte as well as simple equilibrium reaction, etc. The simulation software is developed based on the mode. With the software the relevant simulation is carried out, and the corresponding experiments on a MCB are performed. The results on the simulation and experiments demonstrate that (1) the software can simulate a dynamic process, characteristic peak shape and relevant electrophoregram of a MCB; (2) the simulator can quantitatively compute velocities of MCB and complex boundary (CB), all of ionic concentrations (especially the concentration of complex) and sweeping efficiency; (3) these simulation results mentioned above are generally in accordance with the experiments. The simulation software holds evident significances for the study on a MCB and conditional optimization in such an EDTA-based sample sweeping of metal ion in CE. 相似文献
8.
应用移动反应界面富集技术进行毛细管电泳尿液指纹分析 总被引:1,自引:0,他引:1
快速灵敏的尿液指纹图谱分析对于临床诊断中发现新的生物标记至关重要。该文建立了一种简便、快速、灵敏的移动反应界面(MRB)介导的富集技术进行毛细管电泳尿液指纹图谱分析。MRB由25 mmol/L甘氨酸(Gly)-HCl(pH 2.5)作为样品缓冲液和50 mmol/L Gly-NaOH(pH 12.3)作为电泳缓冲液形成。与常规的毛细管区带电泳只能观察到尿液中不到10个峰相比,采用MRB可以观察到超过80个峰并将检测灵敏度提高了至少十几倍,显示该方法对于代谢组学分析具有重要的意义。 相似文献
9.
The paper advanced the theoretical procedures for quantitative design on selective stacking of zwitterions in full capillary sample matrix by a cathodic-direction moving reaction boundary (MRB) in capillary electrophoresis (CE) under control of electroosmotic flow (EOF). With the procedures, we conducted the theoretical computations on the selective stacking of two test analytes of L-histidine (His) and L-tryptophan (Trp) by the MRB created with 30 mM pH 3.0 formic acid-NaOH buffer and 2-80 mM sodium formate. The results revealed the following three predictions. At first, the MRB cannot stack His and Trp plugs if less than 12.5 mM sodium formate is used to form the MRB and prepare the sample matrix. Second, the MRB can stack His and/or Trp sample plugs completely if higher than 50 mM sodium formate is chosen to form the MRB. Third, the MRB can only focus His plug completely, but stack Trp plug partially if 20-50 mM sodium formate is used; this implied the complete MRB-induced selective stacking to His rather than Trp. All the three predictions were quantitatively proved by the experiments. With great dilution of sample matrix and control of EOF, controllable, simultaneous and MRB-induced selective stacking and separation of zwitterions were achieved. The theoretical results hold evident significances to the quantitative design of selective stacking conditions and the increase of detection sensitivity of zwitterions in CE. In addition, the control of EOF by cetyltrimethylammonium bromide (CTAB) can evidently improve the stacking efficiency to both His and Trp. 相似文献
10.
Online sample concentration or stacking of basic drugs by transient isotachophoresis with the injection of an acid in co-electroosmotic flow capillary zone electrophoresis was studied experimentally and with computer simulation. The acid stacking strategy afforded an order of magnitude improvement in concentration sensitivity for model tricyclic antidepressant and β blocker drugs. 相似文献
11.
Quantitative investigations were performed for the synthesis of colloidal particles of cobalt hydroxide in agarose gel by the moving chemical reaction boundary method . The experimental results show that: (1) the sizes of the colloidal particles can be controlled by changing the concentration of agarose gel, (2) the concentration of the colloidal particles is also controlled by changing the concentrations of CoCl2 and/or NaOH, and (3) most importantly, the concentration of colloidal particles can be predicted with the theory of moving chemical reaction boundary (MCRB). The colloidal particles prepared by the MCRB are amorphous and are more easily oxidized than particles prepared by other methods. 相似文献
12.
The determination of inorganic cations in blood plasma is demonstrated using a combination of moving boundary electrophoresis (MBE) and zone electrophoresis. The sample loading performed under MBE conditions is studied with the focus on the quantitative analysis of lithium. A concentration adjustment takes place when the sample components migrate into the chip during the sample loading step. Using a heart-cutting method, a diluted sample plug is subsequently separated with capillary zone electrophoresis. The excessive dispersion that is typical of the samples with a high ionic strength is thereby prevented. The method can be easily applied to commercially available capillary electrophoresis microchips under the condition that the electroosmotic flow is suppressed. For the first time the lithium concentration is determined in the blood plasma from a patient on lithium therapy without sample pretreatment. Using a microchip with conductivity detection, a detection limit of 0.1 mmol/L is obtained for lithium in a 140 mmol/L sodium matrix. 相似文献
13.
Yuh-Jyh Jong Yi-Hui Ho Wei-Kung Ko Shou-Mei Wu 《Journal of chromatography. A》2009,1216(44):7570-7575
Heroin metabolites including morphine, codeine, and 6-acetylmorphine were determined by cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography (CSEI–sweep-MEKC). Liquid–liquid extraction was used for urine pretreatment. An uncoated fused silica capillary (Ld = 30 cm, 50 μm ID) was filled with phosphate buffer (50 mM, pH 2.5) containing 30% methanol, then high conductivity buffer (100 mM phosphate, 41.3 kPa for 18 s) was followed. Samples were injected electrokinetically (20 kV, 300 s). The sweeping and separation were performed at −25 kV using phosphate buffer (20 mM, pH 2.5) and 80 mM sodium dodecyl sulfate. The baseline separation was done within 10 min. During method validation, the calibration curves were linear over a range of 50–500 ng/mL (r ≧ 0.994). The RSD and RE values in intra-day and inter-day assays were all below 20%, which showed good precision and accuracy. Their detection limits were 10 ng/mL (S/N = 3). The optimized method was applied to determine real urine samples from addicts. These samples were confirmed by liquid chromatography/mass spectrometry. 相似文献
14.
《Electrophoresis》2018,39(4):608-615
A sensitive method using CZE‐UV detection has been developed for the determination of five tetracycline antibiotics in human urine samples. To improve the sensitivity of the method, an on‐line preconcentration strategy, named field‐amplified sample injection, has been developed, based on the electrokinetic injection of the sample, which requires only a 1:100 dilution with sample solvent before injection. Under optimum conditions, sensitivity enhancement factors ranged from 450 to 800 for the studied compounds. The applicability of the proposed method was demonstrated by the determination of these antibiotics in spiked urine samples. The limits of quantification were lower than 0.8 mg/L and the precision (intra‐ and inter‐day), expressed as %RSD was below 14%. Recoveries ranged from 92.1 to 96.7%. Thus, the proposed procedure is a simple, fast and efficient strategy which could be used as therapeutic drug monitoring in human urine samples. 相似文献
15.
Ping Li Wenjie Zhao Xiaoning Wang Guoyue Shi Tianshu Zhou 《Journal of separation science》2013,36(2):334-340
A rapid and sensitive method based on transient ITP and field enhancement in CE with electrochemical detection at copper disk electrode was developed for the simultaneous separation and determination of three estrogens: estrone, 17β‐estradiol, and estriol. The effects of several important factors that influence the separation and detection were investigated. Under the optimum conditions, the estrogens could be separated in 0.06 mol/L sodium hydroxide solution within 14 min. With transient ITP by addition of 0.5% NaCl, a good linear response was obtained for three estrogens from 0.2 to 10 μmol/L, with correlation coefficients higher than 0.9993. The detection limits were 8.9 × 10?8, 6.7 × 10?8, and 1.1 × 10?7 mol/L (S/N = 3) for estriol, 17β‐estradiol, and estrone, respectively. This method was successfully employed to analyze different water samples from waterworks, tap water, fishpond, and river samples with recoveries in the range of 90.8–108.9%, and RSDs < 4.69%. The satisfied results demonstrated that this method was of convenient preparation, high sensitivity, and good repeatability, which could be applied to the rapid determination of environmental water samples. 相似文献
16.
A visual detection of protein content based on titration of moving reaction boundary electrophoresis
Hou-Yu Wang Cheng-Ye Guo Chen-Gang Guo Liu-Yin Fan Lei Zhang Cheng-Xi Cao 《Analytica chimica acta》2013
A visual electrophoretic titration method was firstly developed from the concept of moving reaction boundary (MRB) for protein content analysis. In the developed method, when the voltage was applied, the hydroxide ions in the cathodic vessel moved towards the anode, and neutralized the carboxyl groups of protein immobilized via highly cross-linked polyacrylamide gel (PAG), generating a MRB between the alkali and the immobilized protein. The boundary moving velocity (VMRB) was as a function of protein content, and an acid–base indicator was used to denote the boundary displacement. As a proof of concept, standard model proteins and biological samples were chosen for the experiments to study the feasibility of the developed method. The experiments revealed that good linear calibration functions between VMRB and protein content (correlation coefficients R > 0.98). The experiments further demonstrated the following merits of developed method: (1) weak influence of non-protein nitrogen additives (e.g., melamine) adulterated in protein samples, (2) good agreement with the classic Kjeldahl method (R = 0.9945), (3) fast measuring speed in total protein analysis of large samples from the same source, and (4) low limit of detection (0.02–0.15 mg mL−1 for protein content), good precision (R.S.D. of intra-day less than 1.7% and inter-day less than 2.7%), and high recoveries (105–107%). 相似文献
17.
Juan José Berzas Nevado Juana Rodríguez Flores Francisco Javier Guzmán Bernardo 《Analytica chimica acta》2006,559(1):9-14
A simple, rapid and sensitive procedure using solid phase extraction and capillary zone electrophoresis for the determination of propranolol (a beta-blocker) and one of its metabolites, N-desisopropylpropranolol, has been developed and validated. The optimum separation of both analytes was obtained in a 37 cm × 75 μm fused silica capillary using 20 mmol/L phosphate buffer (pH 2.2) as electrolyte, at 25 kV and 30 °C, and hydrodynamic injection for 5 s. Prior to the electrophoretic separation, the samples were cleaned up and concentrated using a C18 cartridge and then, eluted with methanol, allowing a concentration factor of 30.Good results were obtained in terms of precision, accuracy and linearity. The limits of detection were 28 and 30 μg/L for N-desisopropylpropranolol and propranolol, respectively. Additionally, a robustness test of the method was carried out using the Plackett-Burman fractional factorial model with a matrix of 15 experiments.The presented method has been applied to the determination of both compounds in human urine. 相似文献
18.
Cortacero-Ramírez S Segura-Carretero A Cruces-Blanco C Romero-Romero ML Fernández-Gutiérrez A 《Analytical and bioanalytical chemistry》2004,380(5-6):831-837
Simultaneous determination of alcohols, amines, amino acids, flavonoids, and purine and pyrimidine bases in bottled beer samples directly without any pre-treatment was carried out by capillary zone electrophoresis with diode-array detection. Electrolyte conditions such as pH, composition and concentration of the buffer, working voltage and type and time of injection were checked. The best separation of the cited analytes was achieved in 70 mM sodium borate solution and pH 10.25. The detection limits were from 2.1 to 5.6 mg L–1 for the 18 compounds studied. The developed method is rapid, sensitive and quantitative and has been applied to seven types of international bottled beers of different origins bought locally. 相似文献
19.
Diana L.D. Lima 《Talanta》2007,72(4):1404-1409
Operational parameters like migration time, temperature, voltage, composition of background electrolyte and content of organic modifier were optimized in CZE for the determination of lignin-like phenolic compounds.The applied background electrolyte buffer consisted of a Na2B4O7, KH2PO4 aqueous solution, pH 9.15 using acetonitrile as organic modifier with UV-detection. Compounds, such as acetosyringone, acetovanillone, syringealdehyde, p-hydroxyacetophenone, vanillin, syringic acid, ferulic acid, p-hydroxybenzaldehyde, p-coumaric acid, vanillic acid and p-hydroxybenzoic acid were applied as reference compounds.The quality and quantity of different phenolic compounds obtained upon alkaline CuO oxidation of a commercial humic acid were determined with CZE using ethylvanillin as internal standard.The optimized CZE revealed has being an appropriate method since it is quick, sensitive and quantitative and does not require a time-consuming sample preparation. 相似文献
20.
A novel method for the determination of norfloxacin (NOR) and levofloxacin (LVX) was developed by CE separation and electrochemiluminesence detection (ECL). The methods for capillary conditioning and the effect of solvent type were studied. Parameters affecting the CE and ECL were also investigated. Under the optimum conditions, the two analytes were well separated within 9 min. The LODs (S/N = 3) in standard solution are 4.8 x 10(-7) mol/L for NOR and 6.4 x 10(-7) mol/L for LVX, respectively. The precisions of intraday and interday are less than 4.2 and 8.1%, respectively. The LOQs (S/N = 10) in real human urine samples are 1.2 x 10(-6) mol/L for NOR and 1.4 x 10(-6) mol/L for LVX, respectively. The applicability of the proposed method was illustrated in the determination of NOR and LVX in human urine samples and the monitoring of pharmacokinetics for NOR. The recoveries of NOR and LVX at different levels in human urine samples were between 84.3 and 92.3%. 相似文献