首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The SUT‐NANOTEC‐SLRI beamline was constructed in 2012 as the flagship of the SUT‐NANOTEC‐SLRI Joint Research Facility for Synchrotron Utilization, co‐established by Suranaree University of Technology (SUT), National Nanotechnology Center (NANOTEC) and Synchrotron Light Research Institute (SLRI). It is an intermediate‐energy X‐ray absorption spectroscopy (XAS) beamline at SLRI. The beamline delivers an unfocused monochromatic X‐ray beam of tunable photon energy (1.25–10 keV). The maximum normal incident beam size is 13 mm (width) × 1 mm (height) with a photon flux of 3 × 108 to 2 × 1010 photons s?1 (100 mA)?1 varying across photon energies. Details of the beamline and XAS instrumentation are described. To demonstrate the beamline performance, K‐edge XANES spectra of MgO, Al2O3, S8, FeS, FeSO4, Cu, Cu2O and CuO, and EXAFS spectra of Cu and CuO are presented.  相似文献   

2.
The crystal and local atomic structure of monoclinic ReO2 (α‐ReO2) under hydrostatic pressure up to 1.2 GPa was investigated for the first time using both X‐ray absorption spectroscopy and high‐resolution synchrotron X‐ray powder diffraction and a home‐built B4C anvil pressure cell developed for this purpose. Extended X‐ray absorption fine‐structure (EXAFS) data analysis at pressures from ambient up to 1.2 GPa indicates that there are two distinct Re—Re distances and a distorted ReO6 octahedron in the α‐ReO2 structure. X‐ray diffraction analysis at ambient pressure revealed an unambiguous solution for the crystal structure of the α‐phase, demonstrating a modulation of the Re—Re distances. The relatively small portion of the diffraction pattern accessed in the pressure‐dependent measurements does not allow for a detailed study of the crystal structure of α‐ReO2 under pressure. Nonetheless, a shift and reduction in the (011) Bragg peak intensity between 0.4 and 1.2 GPa is observed, with correlation to a decrease in Re—Re distance modulation, as confirmed by EXAFS analysis in the same pressure range. This behavior reveals that α‐ReO2 is a possible inner pressure gauge for future experiments up to 1.2 GPa.  相似文献   

3.
Here, soft X‐ray synchrotron radiation transmitted through microchannel plates is studied experimentally. Fine structures of reflection and XANES Si L‐edge spectra detected on the exit of silicon glass microcapillary structures under conditions of total X‐ray reflection are presented and analyzed. The phenomenon of the interaction of channeling radiation with unoccupied electronic states and propagation of X‐ray fluorescence excited in the microchannels is revealed. Investigations of the interaction of monochromatic radiation with the inner‐shell capillary surface and propagation of fluorescence radiation through hollow glass capillary waveguides contribute to the development of novel X‐ray focusing devices in the future.  相似文献   

4.
The Verwey transition in Fe3O4 nanoparticles with a mean diameter of 6.3 nm is suppressed after capping the particles with a 3.5 nm thick shell of SiO2. By X‐ray absorption spectroscopy and its associated X‐ray magnetic circular dichroism this suppression can be correlated to localized Fe2+ states and a reduced double exchange visible in different site‐specific magnetization behavior in high magnetic fields. The results are discussed in terms of charge trapping at defects in the Fe3O4/ SiO2 interface and the consequent difficulties in the formation of the common phases of Fe3O4. By comparison to X‐ray absorption spectra of bare Fe3O4 nanoparticles in course of the Verwey transition, particular changes in the spectral shape could be correlated to changes in the number of unoccupied d states for Fe ions at different lattice sites. These findings are supported by density functional theory calculations.  相似文献   

5.
A new multi‐purpose operando electrochemical cell was designed, constructed and tested on the Swiss–Norwegian Beamlines BM01 and BM31 at the European Synchrotron Radiation Facility. Single‐crystal sapphire X‐ray windows provide a good signal‐to‐noise ratio, excellent electrochemical contact because of the constant pressure between the electrodes, and perfect electrochemical stability at high potentials due to the inert and non‐conductive nature of sapphire. Examination of the phase transformations in the Li1–xFe0.5Mn0.5PO4 positive electrode (cathode) material at C/2 and 10C charge and discharge rates, and a study of the valence state of the Ni cations in the Li1–xNi0.5Mn1.5O4 cathode material for Li‐ion batteries, revealed the applicability of this novel cell design to diffraction and spectroscopic investigations of high‐power/high‐voltage electrodes for metal‐ion batteries.  相似文献   

6.
This journal, X‐Ray Spectrometry, celebrates its 40th anniversary this year. The state of the publications on X‐ray spectral analysis from 1972 onward is considered. The distribution of materials over countries is presented, as published in X‐Ray Spectrometry for 40 years, in 5‐year time intervals: 1972–1976, 1977–1981, and so on. The participation of Russian scientists contributing to the publications in this journal is discussed. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

7.
An X‐ray Raman spectrometer for studies of local structures in minerals is discussed. Contrary to widely adopted back‐scattering spectrometers using ≤10 keV X‐rays, a spectrometer utilizing ~20 keV X‐rays and a bent Laue analyzer is proposed. The 20 keV photons penetrate mineral samples much more deeply than 10 keV photons, so that high intensity is obtained owing to an enhancement of the scattering volume. Furthermore, a bent Laue analyzer provides a wide band‐pass and a high reflectivity, leading to a much enhanced integrated intensity. A prototype spectrometer has been constructed and performance tests carried out. The oxygen K‐edge in SiO2 glass and crystal (α‐quartz) has been measured with energy resolutions of 4 eV (EXAFS mode) and 1.3 eV (XANES mode). Unlike methods previously adopted, it is proposed to determine the pre‐edge curve based on a theoretical Compton profile and a Monte Carlo multiple‐scattering simulation before extracting EXAFS features. It is shown that the obtained EXAFS features are reproduced fairly well by a cluster model with a minimal set of fitting parameters. The spectrometer and the data processing proposed here are readily applicable to high‐pressure studies.  相似文献   

8.
In recent years, graphene‐incorporated micro‐/nanocomposites represent one of the hottest developing directions for the composite materials. However, a large number of active nanoparticles (NPs) are still in the unprotected state in most constructed graphene‐containing designs, which will seriously impair the effects of the graphene additives. Here, a fully protected Fe3O4‐based micro‐/nanocomposite (G/Fe3O4@C) is rationally developed by carbon‐boxing the common graphene/Fe3O4 microparticulates (G/Fe3O4). The processes and results of full protection are tracked in detail and characterized by X‐ray diffraction, X‐ray photoelectron spectroscopy, and nitrogen absorption–desorption isotherms, as well as scanning and transition electron microscopy. When used as the anode for lithium‐ion batteries, the fully protected G/Fe3O4@C exhibits the best lithium‐storage properties in terms of the highest rate capabilities and the longest cycle life compared to the common G/Fe3O4 composites and commercial Fe3O4 products. These much improved properties are mainly attributed to its novel structural features including complete protection of active Fe3O4 nanoparticles by the surface carbon box, a robust conductive network composed of nitrogen‐doped graphene nanosheets, ultra‐small Fe3O4 NPs of 4–5 nm, abundant mesopores to accommodate the volume variation during cycling, and micrometer‐sized secondary particles.  相似文献   

9.
The trace elements of scalp hair samples from ≥60‐year‐old dementia patients and normal persons have been studied by X‐ray absorption near‐edge spectroscopy (XANES) in fluorescent mode and wavelength‐dispersive X‐ray fluorescence spectrometry. Comparisons of hair trace element levels of age‐matched dementia patients and normal persons revealed significantly elevated amounts of calcium, chlorine and phosphorus in dementia patients relative to normal persons. The results of XANES measurements identify the chemical forms of deposited calcium and phosphorus in the hair samples of both dementia patients and normal persons to be calcium chloride (CaCl2) and phosphate (PO43?), respectively. The amount of sulfur in hairs of dementia patients was found to be not significantly different from that in normal persons. The sulfur K‐edge XANES spectra, however, show significantly higher accumulations of sulfur in the sulfate (SO42?) form in hairs of Alzheimer's disease and Parkinson's disease dementia patients. This study presents the possible roles of calcium, chlorine, phosphorus and sulfur in the etiology of dementia in elderly patients.  相似文献   

10.
Here the correlation between the chemical shift in X‐ray absorption spectroscopy, the geometrical structure and the formal valence state of the Mn atom in mixed‐valence manganites are discussed. It is shown that this empirical correlation can be reliably used to determine the formal valence of Mn, using either X‐ray absorption spectroscopy or resonant X‐ray scattering techniques. The difficulties in obtaining a reliable comparison between experimental XANES spectra and theoretical simulations on an absolute energy scale are revealed. It is concluded that the contributions from the electronic occupation and the local structure to the XANES spectra cannot be separated either experimentally or theoretically. In this way the geometrical and electronic structure of the Mn atom in mixed‐valence manganites cannot be described as a bimodal distribution of the formal integer Mn3+ and Mn4+ valence states corresponding to the undoped references.  相似文献   

11.
The unoccupied electronic structures of 5 nm thick high permittivity (k) oxides (HfO2, ZrO2, and Al2O3) and SiO2 films on Ge substrates were examined using O K‐edge X‐ray absorption spectroscopy. Comparative studies with those on Si substrates showed contrasts in the conduction bands, which should be due to the formation of interface states. In the Al2O3 and SiO2 films, GeO2 layers are formed at the interface and they suppress in part the formation of detrimental germanate phases. In contrast, in the HfO2 and ZrO2 films, no signature of the Ge‐oxide phase is observed but some germanate phases are expected to prevail, suggesting a degradation of the gate oxide characteristics. (© 2012 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

12.
Advances in resonant inelastic X‐ray scattering (RIXS) have come in lockstep with improvements in energy resolution. Currently, the best energy resolution at the Ir L3‐edge stands at ~25 meV, which is achieved using a diced Si(844) spherical crystal analyzer. However, spherical analyzers are limited by their intrinsic reflection width. A novel analyzer system using multiple flat crystals provides a promising way to overcome this limitation. For the present design, an energy resolution at or below 10 meV was selected. Recognizing that the angular acceptance of flat crystals is severely limited, a collimating element is essential to achieve the necessary solid‐angle acceptance. For this purpose, a laterally graded, parabolic, multilayer Montel mirror was designed for use at the Ir L3‐absorption edge. It provides an acceptance larger than 10 mrad, collimating the reflected X‐ray beam to smaller than 100 µrad, in both vertical and horizontal directions. The performance of this mirror was studied at beamline 27‐ID at the Advanced Photon Source. X‐rays from a diamond (111) monochromator illuminated a scattering source of diameter 5 µm, generating an incident beam on the mirror with a well determined divergence of 40 mrad. A flat Si(111) crystal after the mirror served as the divergence analyzer. From X‐ray measurements, ray‐tracing simulations and optical metrology results, it was established that the Montel mirror satisfied the specifications of angular acceptance and collimation quality necessary for a high‐resolution RIXS multi‐crystal analyzer system.  相似文献   

13.
The ability to probe morphology and phase distribution in complex systems at multiple length scales unravels the interplay of nano‐ and micrometer‐scale factors at the origin of macroscopic behavior. While different electron‐ and X‐ray‐based imaging techniques can be combined with spectroscopy at high resolutions, owing to experimental time limitations the resulting fields of view are too small to be representative of a composite sample. Here a new X‐ray imaging set‐up is proposed, combining full‐field transmission X‐ray microscopy (TXM) with X‐ray absorption near‐edge structure (XANES) spectroscopy to follow two‐dimensional and three‐dimensional morphological and chemical changes in large volumes at high resolution (tens of nanometers). TXM XANES imaging offers chemical speciation at the nanoscale in thick samples (>20 µm) with minimal preparation requirements. Further, its high throughput allows the analysis of large areas (up to millimeters) in minutes to a few hours. Proof of concept is provided using battery electrodes, although its versatility will lead to impact in a number of diverse research fields.  相似文献   

14.
X‐ray absorption and scattering spectroscopies involving the 3d transition‐metal K‐ and L‐edges have a long history in studying inorganic and bioinorganic molecules. However, there have been very few studies using the M‐edges, which are below 100 eV. Synchrotron‐based X‐ray sources can have higher energy resolution at M‐edges. M‐edge X‐ray absorption spectroscopy (XAS) and resonant inelastic X‐ray scattering (RIXS) could therefore provide complementary information to K‐ and L‐edge spectroscopies. In this study, M2,3‐edge XAS on several Co, Ni and Cu complexes are measured and their spectral information, such as chemical shifts and covalency effects, are analyzed and discussed. In addition, M2,3‐edge RIXS on NiO, NiF2 and two other covalent complexes have been performed and different dd transition patterns have been observed. Although still preliminary, this work on 3d metal complexes demonstrates the potential to use M‐edge XAS and RIXS on more complicated 3d metal complexes in the future. The potential for using high‐sensitivity and high‐resolution superconducting tunnel junction X‐ray detectors below 100 eV is also illustrated and discussed.  相似文献   

15.
X‐ray absorption near‐edge spectroscopy (XANES) is a spectroscopic technique using synchrotron light to determine the valence state of excited atoms as well as the electronegativity of their neighbouring atoms. XANES spectra can provide information about the chemical bond in the second coordination shell of the excited atom. In this study, XANES spectra of unknown compounds from human kidney stones were recorded around the K‐edges of sulfur, phosphorus and calcium. The XANES results agree well with the diffractogram data of the same stones obtained through an X‐ray powder diffraction (XRPD) technique. By comparing the measurement techniques presented here, it is shown that XANES requires a smaller amount of each sample than XRPD for analysis.  相似文献   

16.
For spectral imaging of chemical distributions using X‐ray absorption near‐edge structure (XANES) spectra, a modified double‐crystal monochromator, a focusing plane mirrors system and a newly developed fluorescence‐type X‐ray beam‐position monitoring and feedback system have been implemented. This major hardware upgrade provides a sufficiently stable X‐ray source during energy scanning of more than hundreds of eV for acquisition of reliable XANES spectra in two‐dimensional and three‐dimensional images. In recent pilot studies discussed in this paper, heavy‐metal uptake by plant roots in vivo and iron's phase distribution in the lithium–iron–phosphate cathode of a lithium‐ion battery have been imaged. Also, the spatial resolution of computed tomography has been improved from 70 nm to 55 nm by means of run‐out correction and application of a reconstruction algorithm.  相似文献   

17.
A cell for the investigation of interfaces under pressure is presented. Given the pressure and temperature specifications of the cell, P≤ 100 bar and 253 K ≤T≤ 323 K, respectively, high‐energy X‐rays are required to penetrate the thick Al2O3 windows. The CH4(gas)/H2O(liquid) interface has been chosen to test the performance of the new device. The measured dynamic range of the high‐energy X‐ray reflectivity data exceeds 10?8, thereby demonstrating the validity of the entire experimental set‐up.  相似文献   

18.
Successful X‐ray photon correlation spectroscopy studies often require that signals be optimized while minimizing power density in the sample to decrease radiation damage and, at free‐electron laser sources, thermal impact. This suggests exploration of scattering outside the Fraunhofer far‐field diffraction limit d2R, where d is the incident beam size, λ is the photon wavelength and R is the sample‐to‐detector distance. Here it is shown that, in an intermediate regime d2/λ > Rdξ/λ, where ξ is the structural correlation length in the material, the ensemble averages of the scattered intensity and of the structure factor are equal. Similarly, in the regime d2/λ > Rdξ(τ)/λ, where ξ(τ) is a time‐dependent dynamics length scale of interest, the ensemble‐averaged correlation functions g1(τ) and g2(τ) of the scattered electric field are also equal to their values in the far‐field limit. This broadens the parameter space for X‐ray photon correlation spectroscopy experiments, but detectors with smaller pixel size and variable focusing are required to more fully exploit the potential for such studies.  相似文献   

19.
A spectrometer for resonant inelastic X‐ray scattering (RIXS) is proposed where imaging and dispersion actions in two orthogonal planes are combined to deliver a full two‐dimensional map of RIXS intensity in one shot with parallel detection at incoming hvin and outgoing hvout photon energies. Preliminary ray‐tracing simulations with a typical undulator beamline demonstrate a resolving power well above 11000 with both hvin and hvout near 930 eV, with a vast potential for improvement. Combining this instrument – nicknamed hv2 spectrometer – with an X‐ray free‐electron laser source simplifies its technical implementation and enables efficient time‐resolved RIXS experiments.  相似文献   

20.
A theoretical study of the X‐ray absorption near‐edge structure (XANES) spectra at the Mn K‐edge in the La1?xCaxMnO3 series is reported. The relationship between the edge shift, the Ca–La substitution and the distortion of the MnO6 octahedra in these systems has been studied. It is shown that, by correctly considering these effects simultaneously, the experimental XANES data are consistent with the presence of two different Mn local environments in the intermediate La1?xCaxMnO3 compounds. By taking into account the energy shift associated with the modification of the MnO6 distortion as Ca substitutes for La, it is possible to reproduce the XANES spectra of the intermediate‐doped compounds starting from the experimental spectra of the end‐members LaMnO3 and CaMnO3. These results point out the need to re‐examine the conclusions derived in the past from the simple analysis of the Mn K‐edge XANES edge‐shift in these materials. In particular, it is shown that the modification of the Mn K‐edge absorption through the La1?xCaxMnO3 series is well reproduced by considering the simultaneous presence of both distorted and undistorted octahedra and, consequently, that the existence of charge‐ordering phenomena cannot be ruled out from the XANES data.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号