首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new method of SS-RTP for the determination of trace silver has been established. This method is based on the fact that Ag+, when activated by ,-bipyridyl (bipy) in a media of HAc–NaAc (pH=4.9), can catalyze the reaction of Rhodamine B (RhoB) oxidized by K2S2O8, thus causing the Solid Substrate Room-Temperature Phosphorescence (SS-RTP) of RhoB to be quenched. The activating efficiency of bipy is 6.7 times higher than that of o-phenanthroline (phen). The reduction of the phosphorescence intensity (Ip) of RhoB is directly proportional to the concentration of Ag+ ions in the range of 1.6016.0agspot–1 (0.40µLspot–1). The regression equation of the working curve can be expressed as Ip=18.78+5.100mAg+ (agspot–1) (r=0.9994, n=6), the detection limit is 0.28agspot–1. This rapid, accurate and sensitive method has been successfully applied to the determination of trace silver in tea and human hair samples, and the results agree well with the Atomic Absorption Spectroscopy (AAS) method. The mechanism of the catalyzing reaction is also discussed.  相似文献   

2.
A method for the determination of sulfide based on its interference with the determination of Hg by cold vapor atomic absorption spectrometry is described. The decrease in mercury absorbance at 253.7nm is proportional to the concentration of sulfide over the range of 10–320ngmL–1. The limit of detection was found to be 7ngmL–1 and the relative standard deviation (R.S.D.) for the determination of different concentrations of sulfide was in the range of 1.8–2.2%. This method was applied to the determination of sulfide in whole human blood after gas-phase separation.  相似文献   

3.
Thallium in natural water samples was determined by electrothermal atomic absorption spectrometry after 1000-fold enrichment by mini solid-phase extraction from a 100-mL sample solution. A Tl-pyrrolidine-1-carbodithioate complex formed in a sample solution of pH 1.6 was extracted on fine particles of a cellulose nitrate resin dispersed in the sample solution. The cellulose nitrate resin was then collected on a membrane filter (25mmø) by filtration under suction using a glass funnel with an effective filtration area of 0.64cm2. As a result, a circular thin layer of the resin phase with a diameter of 9mm was obtained. Then the resin phase was carved out by an acrylate resin puncher with a 10-mmø hole to put it into a sample cup containing 100µL of 10mM HNO3 containing 0.5mM NaCl. The resin phase was suspended in the solution by ultrasonication. 1000-fold enrichment was thus attained within 15min, and the suspension was delivered to electrothermal atomic absorption spectrometry. The linear calibration graph was obtained in the range of 0–4ng of Tl in 100mL of a sample solution. The detection limit obtained by 3 method was 0.19ng. The proposed method was applied to the determination of Tl in natural water samples. The results showed the concentration of Tl in seawater was 12.1±1.8pgmL–1 for the calibration graph method and 12.6±1.4pgmL–1 for the standard addition method. A snowmelt sample contained 20.7±1.0pgmL–1 of Tl.  相似文献   

4.
A simple and novel electrogenerated chemiluminescence (ECL) method for the determination of sulfite has been developed based on the energy transfer ECL process. It was found that a weak ECL signal of sulfite was electrochemically generated on a platinum electrode in neutral aqueous solution. The signal was strongly enhanced by rhodamine B as an energy receptor and further enhanced by the neutral surfactant Tween 80. In 0.10M phosphate buffer solution (pH=7.5) containing 2.0×10–6gmL–1 rhodamine B and 0.4% (v/v) Tween 80, the ECL response to the concentration of sulfite at a potential of 0.82V was linear over a range of 1.0×10–7gmL–1 to 8.0×10–6gmL–1, and the detection limit was 5×10–8gmL–1. The relative standard deviation (n=11, 1.0×10–6gmL–1) was 3.8%. The proposed method has been successfully applied to the determination of sulfite in pharmaceutical injections and white sugar samples.  相似文献   

5.
A method for the determination of trace amounts of enrofloxacin based on solid-phase spectrofluorimetry has been developed. The relative fluorescence intensity of enrofloxacin fixed on Sephadex SP C-25 gel was measured directly after packing the gel beads in a 1-mm silica cell, using a solid-phase attachment. The wavelengths of excitation and emission were 277 and 448nm, respectively. The linear concentration range of application was 0.2–4.0ngmL–1 of enrofloxacin, with a relative standard deviation of 1.2% (for a level of 2.0ngmL–1) and a detection limit of 0.04ngmL–1. The method was applied to the determination of enrofloxacin in commercial pharmaceutical formulations and spiked canine serum samples. It was validated using HPLC as a reference method and applying the standard addition methodology. Recovery levels of the method reached 100% in all cases.  相似文献   

6.
The interaction of indophenol blue (IPB) with proteins in aqueous solution has been studied by optical absorption and Rayleigh light scattering (RLS) spectroscopy. At pH 3.8, the weak RLS of IPB is enhanced by proteins. Based on this phenomenon, a novel method for the determination of proteins at nanogram levels using the RLS technique is developed. The method is simple, practical and sensitive. The linear range is 0.25–20.9µgmL–1 for BSA, and 0.25–17.6µgmL–1 for HSA. The detection limits (S/N=3) are 23ngmL–1 for BSA and 22ngmL–1 for HAS. The results for the determination of proteins in human serum samples are very close to those obtained by an established clinical method. There is very little interference from amino acids, metal ions or other coexisting compounds.  相似文献   

7.
A -mercaptopropionic acid (MPA) self-assembled monolayer modified electrode (MPA/SAM/Au) on a gold electrode has been fabricated. The characterization of the MPA/SAM/Au was investigated using attenuated total reflection-fourier transform infrared (ATR-FTIR) and A.C. impedance. The electrochemical behaviors of p-aminophenol (p-AP) were studied at the MPA/SAM/Au by cyclic voltammetry and semi-derivative voltammetry (SDV) in BR buffer solution. The modified electrode shows excellent electrocatalytic activity for the redox of p-AP and accelerates the electron transfer rate. The diffusion coefficient (D) is 4.55×10–6cm2s–1. The oxidative peak current increases linearly with the concentration of p-AP in the range of 4.0×10–88×10–6molL–1 and 1.0×10–52×10–4molL–1 by square wave voltammetry response, respectively. The detection limit (three times the signal blank/slope) is up to 1.2×10–8molL–1. The modified electrode is able to eliminate the interference of p-benzenediol, o-benzenediol and o-AP at a 40-, 90- or 70-fold concentration of p-AP, and it has been satisfactorily used for the determination of the real sample.  相似文献   

8.
75–300ng of bismuth in a sample mass of 20mg of silver can be determined spectrophotometrically in a nitric acid medium (0.18molL–1) with Semi-Xylenol Orange as chromogenic agent. Its selectivity is realized by using less toxic reagents in very small amounts to mask some of the interfering impurity cationic species while the matrix effect is negligible. The conditional formation constant of the colored chelate formed was found to be lgKf=3.1. It exhibits a maximum at 540nm with a molar absorptivity of 4.2×104Lmo1–1cm–1. The linear regression equation for this determination is A=0.022+0.0018C, where C stands for the concentration of Bi (ng per 0.5mL) with a correlation coefficient of 0.9873. The RSD at the level of 200ng of Bi (n=10) was found to be 5%.  相似文献   

9.
A new simple flow injection analysis (FIA) procedure for the spectrophotometric determination of cationic surfactants (CSs), i.e. dodecyltrimethylammonium bromide (DTAB), cetyltrimethylammonium bromide (CTAB), and cetylpyridinium chloride (CPC), is described. The method is based on absorptivity enhancement of the Bi(III)-I complex in the presence of CSs. Among the investigated compounds, highest sensitivity is obtained with CPC, so it was selected for detailed study. The apparent value of molar absorptivity of the complex in terms of CPC is (6.00)×103 Lmol–1cm–1 at max 505nm for FIA determination. The detection limit (3 criterion) of the method for FIA determination is 110µgL–1. The sample throughput is >140 samples h–1. The effect of analytical and FIA variables in the determination of CPC is described. The composition of the complex is discussed. The method is free from interferences of common ions. The method has been applied to the analysis of surfactant contamination in environmental samples, i.e. pond water, municipal/industrial wastewater, sewage, sediment and soil.  相似文献   

10.
A single-wall carbon nanotubes (SWNT) film coated glassy carbon electrode (GCE) was fabricated for the direct determination of 4-nitrophenol (4-NP). The electrochemical behaviors of 4-NP at the SWNT-film coated GCE were examined. In 0.1M phosphate buffer with a pH of 5.0, 4-NP yields a very sensitive and well-defined reduction peak at the SWNT-modified GCE. It is found that the SWNT film exhibits obvious electrocatalytic activity towards the reduction of 4-NP since it not only increases the reduction peak current but also lowers the reduction overpotential. Based on this, an electrochemical method was proposed for the direct determination of 4-NP. The reduction peak current varies linearly with the concentration of 4-NP ranging from 1×10–8 to 5×10–6M, and the detection limit is 2.5×10–9M after 3min of open-circuit accumulation. The relative standard deviation at 2×10–7M 4-NP was about 6% (n=10), suggesting excellent reproducibility. This new method was successfully employed to determine 4-NP in several lake water samples.  相似文献   

11.
A flow-injection procedure for the determination of iron(III) in water is described. The procedure is based on the formation of an ion pair between the tetraphenylarsonium (Ph4As+) (TPA) or tetrabutylammonium (But4N+) (TBA) cations and the tetrathiocyanatoferrate(III) complex (TTF). This ion pair is extracted with chloroform, and the absorbance of the organic phase is measured at 503nm (for Ph4As+) or 475nm (for But4N+). Iron concentrations higher than 0.9×10–6molL–1 (50µgL–1) can be detected in the first case, with a relative standard deviation of 1.9% (n=12), a linear application rangeof between 1.34 and 54.0×10–6molL–1 (75–3015µgL–1), and a sampling frequency of 30h–1. For the ion pair with But4N+, the detection limit is 0.52×10–6molL–1 (29µgL–1), with a relative standard deviation of 1.6% and a linear application range between 0.73 and 54.0×10–6molL–1. Under the proposed working conditions, only Pd(IV), Cu(II) and Bi(III) interfere. With the application of the merging zones technique, considerable amounts of organic reagent can be saved. The TBA method was applied to the analysis of iron(III) in tap and industrial waste waters.  相似文献   

12.
    
By the XPS method it has been shown that in the catalysts obtained by interacting W(-C4H7)4 with SiO2 several oxidation states of the supported tungsten are realized together with a higher coverage of the silica surface with tungsten compounds, as compared with the catalysts prepared by impregnation of SiO2 with an aqueous solution of (NH4)2 WO4.
, , W(-C4H7)4 SiO2, , , SiO2 (NH4)2 WO4.
  相似文献   

13.
A microcolumn on-line preconcentration and separation system was developed for the flame atomic absorption spectrometric (FAAS) determination of trace levels of gold and palladium. The analytes were selectively adsorbed onto the microcolumn packed with 2-mercaptothiazole immobilized silica gel (MBTSG) in an acidity range of 0.1 to 6.0M HCl at a sampling flow rate of 4.0mLmin–1. The analytes adsorbed could be desorbed by a thiourea solution with a flow rate of 2.0mLmin–1. Most of the common coexisting metal ions at a concentration of 25.0mgmL–1 and anions at a concentration of 50.0mgmL–1 did not interfere with the preconcentration and determination of Au and Pd. The limits of detection (LOD), defined as three times the standard deviation of the blank (3), of Au and Pd are 10ngmL–1 and 26ngmL–1, respectively, with a preconcentration time of 60s. The relative standard deviation (RSD) is about 2.0% for 0.20µgmL–1 Au and 0.30µgmL–1 Pd. With a sample loading time of 30min, 6.7ngmL–1 Au and 10ngmL–1 Pd can be preconcentrated quantitatively. A geological sample, an anode slime and a secondary nickel alloy were successfully determined with the proposed method, and the results obtained showed good agreement with the certified values.Received December 23, 2002; accepted May 14, 2003 Published online August 8, 2003  相似文献   

14.
A simple commercial graphite pencil electrode (GPE) was utilized for monitoring caffeine using the square-wave anodic stripping voltammetry (SWASV) method. This method was applied to determine the caffeine levels in several tea samples, which yielded a relative error of 1% in the concentrations. Caffeine was deposited at 0.0V (vs. Ag/AgCl), then reduced at +1.40V to strip it on the GPE. Optimal experimental conditions for the analysis were found to be as follows: pH value of 9 for the medium; deposition potential of 0.0V; deposition time of 120s; SW frequency of 25Hz; SW amplitude of 45mV, and step potential of 6mV. Given these optimum conditions, a linear range was observed within the concentration of 0500mgL–1. At caffeine concentrations of 50.0, 250.0, and 500.0mgL–1, the relative standard deviations in measured concentrations (n=12) were 0.19, 0.09, and 0.11%, respectively. The detection limit was found to be 9.2mgL–1, which is comparable with the result obtained using a carbon paste electrode, equivalent to 8.2mgL–1.  相似文献   

15.
A new method for the simultaneous determination of heavy metal ions in Chinese herbal medicine by microwave digestion and reversed-phase high-performance liquid chromatography (RP-HPLC) has been developed. The Chinese herbal medicine samples were digested by microwave digestion. Lead, cadmium, mercury, nickel, copper, zinc, and tin ions in the digested samples were pre-column derivatized with tetra-(4-chlorophenyl)-porphyrin (T4-CPP) to form the colored chelates which were then enriched by solid phase extraction with C18 cartridge and eluted from the cartridge with tetrahydrofuran (THF). The chelates were separated on a Waters Xterra RP18 column by gradient elution with methanol (containing 0.05molL–1 pyrrolidine-acetic acid buffer salt, pH=10.0) and THF (containing 0.05molL–1 pyrrolidine-acetic acid buffer salt, pH=10.0) as mobile phase at a flow rate of 0.5mLmin–1 and detected with a photodiode array detector in the range of 350–600nm. In the original samples the detection limits of lead, cadmium, mercury, nickel, copper, zinc and tin are 4ngL–1, 3ngL–1, 6ngL–1, 5ngL–1, 2ngL–1, 6ngL–1, and 4ngL–1, respectively. This method was applied to the determination of lead, cadmium, mercury, nickel, copper, zinc and tin in Chinese herbal medicine samples with good results.  相似文献   

16.
A sensitive chemiluminescence method for the determination of acetylspiramycin is presented. It is based on the greatly enhancive effect of acetylspiramycin on the chemiluminescence reaction between luminol and hydrogen peroxide in the flow system. The increase in chemiluminescence intensity was linearly proportional to the acetylspiramycin concentration in the range from 10pg·mL–1 to 2.0ng·mL–1 (r2=0.9979). The detection limit was 3pg·mL–1 (3). At a flow rate of 2.0mL·min–1, the process of determination, including sampling and washing, could be performed in 0.5 min, and the relative standard deviations of seven replicates are less than 5.0%. The proposed method was applied successfully to the determination of acetylspiramycin in pharmaceutical preparations, human urine and serum without pre-treatment. It was found that the excretive ratio of acetylspiramycin reached its maximum 2.0 hours after having been administered orally, and the excretive ratio in 12.0 hours was 8.4.  相似文献   

17.
A novel nano-TiO2 polymer modified glassy carbon (GC) electrode was developed for the determination of an organophosphorous pesticide, fenitrothion (-NO2), in citrate buffer solution. The electrochemical behavior of fenitrothion was characterized by using cyclic voltammetry. An irreversible form, -NO2, was transformed into a reversible redox couple (-NHOH/-NO), and it can be used to determine trace fenitrothion by square wave voltammetry. The experimental parameters, such as film thickness, pH value, accumulation potential and time were optimized. Interestingly, a cyclic voltammetric scan was observed to be more effective than a constant potential for the accumulation of fenitrothion. A linear response over a fenitrothion concentration of 2.5×10–8 to 1.0×10–5M was exhibited, with a detection limit of 1.0×10–8M (S/N=3). The high sensitivity and selectivity of this film electrode was demonstrated by its practical application to the determination of trace amounts of fenitrothion in lake water and apple samples.  相似文献   

18.
The fabrication and electrochemical characteristics of a penicillamine (PCA) self-assembled monolayer modified gold electrode were investigated. The self-assembled electrode shows obvious electrocatalytic activity for the oxidation of epinephrine (EP). In phosphate buffer (pH 7.73), a sensitive oxidation peak was observed at 0.190V with the PCA modified Au electrode. The peak current is proportional to the concentration of EP in the range of 2.0×10–56.0×10–4molL–1 and 5.0×10–6 2.0×10–4molL–1 for cyclic voltammetry (CV) and differential pulse voltammetry (DPV) with the detection limits of 1.8×10–7 and 1.3×10–7molL–1, respectively. The possible reaction mechanism is also discussed. The PCA self-assembled monolayer modified gold electrode is highly stable and can be applied to the determination of EP in practical injection samples. Application is simple, rapid and produces accurate results.  相似文献   

19.
A sub-micrometer thin-layer DNA modified carbon fiber microcylinder electrode was prepared by electrodeposition of ct-DNA at 1.5V (vs. Ag/AgCl). The voltammetric behavior of dopamine (3-hydroxytyramine) was investigated at the modified electrode. It was found that the modified electrode exhibits a highly electrocatalytic activity toward dopamine oxidation. Differential pulse voltammetry was used for determination of dopamine in pH 7.4 phosphate buffer solution. A linear response of the peak current versus the concentration was found in the range of 4×10–6 to 10–4molL–1 at 10–4molL–1 AA (ascorbic acid) coexistence (R=0.9959) and the range of 6×10–5 to 10–3molL–1 at 10–3molL–1 AA (R=0.9960). The presence of a high concentration of ascorbic acid did not interfere with the determination. The proposed method exhibited good recovery and reproducibility. This method can be applied to the detection of DA in real samples.  相似文献   

20.
A novel electroanalytical method for the determination of physcion is described for the first time. Physcion yields an adsorption catalytic voltammetric peak at –0.74V (vs. SCE) in 0.4molL–1 NH4Cl–NH3·H2O buffer solution (pH 10.5) at a carbon paste electrode (CPE). The experimental results indicated that physcion is efficiently accumulated at a CPE by adsorption. In the subsequent potential scan, physcion was reduced to a homologous anthrahydroquinone compound. The compound was then immediately oxidized to physcion by the dissolved oxygen in the solution, and then physcion was again reduced at the CPE. As a result, a cyclic catalytic reaction was established. The second-order derivative peak current is proportional to the physcion concentration in the ranges of 2.0×10–104.0×10–9molL–1 (accumulation 90s) and 4.0×10–92.0×10–8molL–1 (accumulation 60s). The limit of detection is 8×10–11molL–1 (S/N=3) for a 120s accumulation time. The method was applied to the direct determination of physcion in the medicinal plant polygonum multiflorum Thumb with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号