首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A thin-layer chromatography/densitometry method was developed and validated for the determination of oxycodone hydrochloride in oral solutions by using silica gel plates. A horizontal technique was used for development of the plates. The optimum composition for the mobile phase, which provided a suitable Rf value of 0.6 for oxycodone, was propanol-acetic acid-water-25% ammonia-methanol (20 + 1 + 1 + 3 + 10). Detection was at 234 nm. Oxycodone hydrochloride was stable on the sorbent and was precisely and accurately measured in the range of 0.3-1.5 microg/band.  相似文献   

2.
A simple and sensitive high-performance thin-layer chromatography (HPTLC) method has been developed for the quantitative estimation of gatifloxacin and ornidazole in its combined dosage forms. Gatifloxacin and ornidazole were chromatographed on silica Gel 60 F(254) TLC plate using n-butanol:methanol:ammonia (6 M) (8:1:1.5 v/v) as the mobile phase and scanned at 302 nm using a Camag TLC Scanner 3. The R(f) value of gatifloxacin and ornidazole was found to be 0.21 +/- 0.02 and 0.76 +/- 0.04, respectively. The linearity of gatifloxacin and ornidazole were in the range of 100 - 500 ng/spot and 250 - 1250 ng/spot, respectively. The limit of detection was found to be 40 ng/spot for gatifloxacin and 100 ng/spot for ornidazole. The proposed method was applied for the determination of gatifloxacin and ornidazole in combined dosage forms.  相似文献   

3.
A high-performance thin-layer chromatographic (HPTLC) method was used to determine the glycoalkaloids alpha-solanine and alpha-chaconine in potatoes. Alpha-solanine and alpha-chaconine are extracted from dehydrated potatoes with boiling methanol-acetic acid (95 + 5, v/v). The analytes are separated on a Silica Gel 60 F254 HPTLC plate by a saturated mixture of dichloromethane-methanol-water-concentrated ammonium hydroxide (70 + 30 + 4 + 0.4, v/v), which is used for vertical development of the plate up to a distance of 85 mm. For visualization, the plate is dipped 3 times into a modified Carr-Price reagent, 20% (w/v) antimony(III) chloride in acetic acid-dichloromethane (1 + 3, v/v), and subsequently heated on a hot plate at 105 degrees C for 5 min. The glycoalkaloids all appear as red chromatographic zones on a colorless background. Densitometric quantification is performed at 507 nm by reflectance scanning. After determination of the appropriate response function, the proposed method was validated. Good results with respect to linearity, accuracy, and precision were obtained in the concentration range studied.  相似文献   

4.
A simple, sensitive and precise high-performance thin-layer chromatographic (HPTLC) method of analysis of trans-resveratrol in Polygonum cuspidatum root extracts and in dosage forms was developed and validated. The separation was carried out on a TLC aluminium plates precoated with silica gel 60F-254 as the stationary phase, eluted with chloroform-ethylacetate-formic acid (2.5 : 1 : 0.1) as mobile phase. Densitometric analysis of trans-resveratrol was carried out in the absorbance mode at 313 nm. This system was found to give compact spot for trans-resveratrol (Rf value of 0.40+/-0.03). A good linear regression relationship between peak areas and the concentrations was obtained over the range of 0.5-3.0 microg/spot with correlation coefficient 0.9989. The limit of detection and quantification was found to be 9 and 27 ng/spot. The method was validated for precision and recovery. The spike recoveries were within 99.85 to 100.70%. The RSD values of the precision in the range 0.37-1.84%. The proposed developed HPTLC method can be applied for identification and quantitative determination of trans-resveratrol in herbal extracts and dosage forms.  相似文献   

5.
在弱碱性的多聚磷酸钠介质中,二价铜离子、过氧化氢和染料罗丹明B混合可以产生较强的化学发光,法莫替丁、西咪替丁和雷尼替丁对此发光有较强的抑制作用,其抑制发光强度与法莫替丁、西咪替丁和雷尼替丁的质量浓度在0.005~1.0 mg/L范围内呈线性关系,基于此,结合流动注射技术,建立了一种直接测定法莫替丁、西咪替丁和雷尼替丁的化学发光新方法.该方法对法莫替丁、西咪替丁和雷尼替丁的检出限分别为2.7、2.2、2.0μg/L.对500μg/L法莫替丁、西咪替丁和雷尼替丁平行测定11次,其相对标准偏差分别为2.1%,2.4%,2.5%.该方法已成功用于药品中法莫替丁、西咪替丁和雷尼替丁含量的测定.  相似文献   

6.
7.
Summary A new, rapid, sensitive, and specific method for the determination of methoxsalen in dosage forms using HPLC has been developed. methoxsalen is extracted in chloroform, evaporated on a water bath, and the residue is redissolved in ethanol. A standard solution of khellin (internal standard) in ethanol is added, and injected. A plot of peak height ratio (methoxsalen/internal standard) vs. concentration of methoxsalen gave a straight line (r=0.998). The column used was a stainless steel, 3.8 mm×30 cm, and the mobile phase was methanol: water (6040) at a flow rate of 2 cm3/min. Retention times for methoxsalen and khellin were 3.45 and 9.6 min, respectively. This method was found superior to the spectrophotometric assay in that no interference was encountered from structurally similar compounds or from coloring agents used in some commercial methoxsalen products.  相似文献   

8.
A method for the determination of the antineoplastic ether phospholipid hexadecylphosphocholine (HePC) is presented, based on the separation of the lipids by high-performance thin-layer chromatography charring with a cupric sulphate reagent and quantitation by in situ densitometry. The lower limit of determination is ca. 25 pmol. Concentrated hexane-isopropanol extracts of plasma samples can be applied to the plate without further clean-up, making this method useful for clinical drug monitoring. Additional ion-exchange chromatography and removal of the salt contaminants by gel filtration permits the study of endogenous phospholipids together with HePC from the same sample.  相似文献   

9.
A new, simple, precise, and rapid high-performance thin-layer chromatography (HPTLC) method was developed for the analysis of commercial emulsifiable concentrate (EC) formulations of cypermethrin, alpha-cypermethrin, and lambda-cyhalothrin. A known amount of reference grade synthetic pyrethroid and its EC formulation was subjected to TLC, and the amount of pesticide present in the active ingredient spot was estimated by densitometry in a single beam, single wavelength reflectance mode. Calibration curves of the synthetic pyrethroid was linear in the range of 8-24 microg, and the correlation coefficient for the calibration equation ranged between 0.97 and 0.99. Recoveries from laboratory-prepared test samples of the EC formulation were in the range of 95-99%. Pesticide formulations were further analyzed by gas liquid chromatography using flame ionization detector, and results were comparable. The proposed HPTLC method has application for quality control and determination of the shelf life of EC formulations.  相似文献   

10.
11.
This paper describes two simple, specific, accurate, and precise methods for estimation of olopatadine hydrochloride (OLO) in tablet dosage form. The first method is a stability-indicating isocratic RP-HPLC method. The analysis is performed on an RP-18 column using 0.1% orthophosphoric acid (adjusted to pH 4.5 with triethylamine)-acetonitrile (75 + 25, v/v) mobile phase at a flow rate of 1 mL/min. Paracetamol (PAR) was selected as the internal standard. Retention times of OLO and PAR were 11.30 +/- 0.02 and 4.70 +/- 0.03 min, respectively. For the HPTLC method, precoated silica gel 60 F254 aluminum sheets were used as the stationary phase; the mobile phase was methanol-chloroform-ammonia (8 + 2 + 0.1, v/v/v). The detection of the analyte band was carried out at 301 nm, and its Rf value was 0.46 +/- 0.03. The analytical methods were validated according to International Conference on Harmonization guidelines. Linear regression analysis data for the calibration plots showed a good linear relationship between response and concentration in the range of 0.1-1 microg/mL and 0.1-0.9 microg/band for HPLC and HPTLC, respectively.  相似文献   

12.
Two HPLC/MS/MS methods, one for determination of neomycin sulfate and the other for determination of oxytetracycline hydrochloride in the presence of their impurities, were developed and validated. Separations were achieved with gradient elution on a C18 column. All components were ionized by positive-ion electrospray and detected by multiple reaction monitoring. Calibration curves were linear, with correlation coefficients >0.99. Precision of the methods was confirmed by RSD values of 0.34 and 0.71% for neomycin and oxytetracycline, respectively. Recovery values of 101.5 and 101.0%, respectively, indicated adequate accuracy. Analysis time for neomycin was 24 min, with the retention time of the main compound at 10.1 min; for oxytetracycline, the analysis time was 18 min, with the main peak at 9.95 min. Longer retention times than expected were a consequence of the necessity of chromatographic separation of isomers with the same ion transition. All impurities defined in the pharmacopoeias were determined and their identities confirmed. The methods were tested for QC of veterinary dosage forms (commercial powders and injections containing these antibiotics).  相似文献   

13.
Three simple, accurate and sensitive colorimetric methods (A, B and C) for the determination of ranitidine HCl (RHCl) in bulk sample, in dosage forms and in the presence of its oxidative degradates are described. The first method A is based on the oxidation of the drug by N-bromosuccinimide (NBS) and determination of the unreacted NBS by measurement of the decrease in absorbance of amaranth dye (AM) at a suitable lambda(max)=520 nm. The methods B and C involve the addition of excess Ce(4+) and determination of the unreacted oxidant by decrease the red color of chromotrope 2R (C2R) at a suitable lambda(max)=528 nm for method B or decrease the orange pink color of rhodamine 6G (Rh6G) at a suitable lambda(max)=526 nm for method C. Regression analysis of Beer-Lambert plots showed good correlation in the concentration ranges 0.2-3.6, 0.1-2.8 and 0.1-2.6 microg ml(-1) for methods A, B and C, respectively. The apparent molar absorptivity. Sandell sensitivity, detection and quantitation limits were calculated. For more accurate results, Ringbom optimum concentration ranges were 0.3-3.4, 0.2-2.6 and 0.2-2.4 microg ml(-1) for methods A, B and C, respectively. Analyzing pure and dosage forms containing RHCl tested the validity of the proposed methods. The relative standard deviations were 相似文献   

14.
A method is described for the accurate determination in plasma of the beta-hydroxyethylrutosides by measurement of the fluorescence of their borocitrate complexes by scanning densitometry following separation by thin-layer chromatography. A modification is also described for estimation of individual hydroxyethylrutosides and their glucuronide conjugates in samples of bile and urine.  相似文献   

15.
A simple, sensitive, and reproducible high-performance thin-layer chromatographic method using densitometry is presented for the determination of naproxen in rat serum. Only 0.1 mL serum was used for extraction. Separations were performed on 10 x 10 cm plates coated with silica gel, with toluene-ethyl acetate-acetic acid (82 + 15 + 3) as the mobile phase. Benzophenone was used as the internal standard. Quantification was performed by densitometry at 260 nm. The response response for naproxen was linear (r = 0.992) over the range 2-100 mg/L. Method validation demonstrated good recoveries (92-96%), sensitivity (limit of quantitation, 1 mg/L), repeatability of sample application (4%), repeatability of the method (8%), and intermediate precision (5%). The procedure was applied to the quantitation of naproxen in rat serum.  相似文献   

16.
In this paper, a high-performance thin-layer chromatography (HPTLC) method combined with densitometry has been described. Chromatography was performed on silica gel Si 60F254 plates using dichloromethane-ethyl acetate-formic acid (9.5 +/- 0.5 +/- 0.1, v/v) mobile phase. This method has been successfully applied for the determination of phenobarbital in pharmaceuticals. Obtained results were comparable with traditionally used column high-performance liquid chromatography (HPLC) methods. For the proposed procedure, linearity (r > 0.999), sensitivity (limit of detection 0.4 microg/spot), recovery (97.8-102.1%), and repeatability were found to be satisfactory. The HPTLC-densitometry method has many advantages, such as simplicity, reasonable sensitivity, rapidity, and low cost, and it can be successfully used in routine quality control of multidrug preparations containing barbiturates.  相似文献   

17.
High performance thin-layer chromatography (HPTLC) with fluorescence scanning densitometry was used for the quantitative determination of polycyclic aromatic hydrocarbons in the soluble organic fraction of air particulate samples. A method using normalized emission response ratios was developed to determine sample identity and to test for peak homogeneity. To preserve the high sample throughput of HPTLC, the two-point calibration method was used for quantitation. The principal advantages of HPTLC as a screening technique for environmental samples are its low cost, methodological simplicity, high sample throughput, and the ability to analyze crude samples with a minimum amount of sample cleanup.  相似文献   

18.
Summary A high-performance liquid chromatographic (HPLC) method has been developed and validated for the determination of FK506, a new immunosuppressant, in bulk drug samples and dosage forms. Equilibration between FK506 (I) and its tautomeric compounds (II and III) was accomplished artificially in water-dehydrated alcohol (11) employed as an extraction solvent. After reaching equilibrium, separation of I, treated as the representetive of equilibrated FK506, from its related substances was achieved by reversed-phase HPLC on a C18 column with water-isopropyl alcohol-tetrahydrofuran (522, v/v) as the mobile phase, and detection at 220 nm. Component I in dosage forms could be recovered satisfactorily and determined with good precision. The calibration graph was linear over the range 2–6 g for I.  相似文献   

19.
Losartan (LST) is the first orally active nonpeptide angiotensin-II receptor antagonist with an improved safety and tolerability profile. It is prescribed alone or in combination with hydrochlorothiazide (HCTZ) for the treatment of moderate-to-severe hypertension. This paper describes the development of 2 methods that use different techniques, first-derivative spectroscopy and high-performance thin-layer chromatography (HPTLC), to determine LST and HCTZ in the presence of each other. LST and HCTZ in combined preparations were quantitated by using the first-derivative responses at 271.6 nm for LST and 335.0 nm for HCTZ in spectra of their solutions in water. The linearity ranges are 30-70 microg/mL for LST and 7.5-17.5 microg/mL for HCTZ with correlation coefficients of 0.9998 and 0.9997, respectively. In the HPTLC method, a mobile phase of chloroform-methanol-acetone-formic acid (7.5 + 1.5 + 0.5 + 0.03, v/v) and a prewashed Silica Gel G60 F254 TLC plate as the stationary phase were used to resolve LST and HCTZ in a mixture. Two well-separated and sharp peaks for LST and HCTZ were obtained at Rf values of 0.61+/-0.02 and 0.41+/-0.02, respectively. LST and HCTZ were quantitated at 254.0 nm. The linearity ranges obtained for the HPTLC method are 400-1200 and 100-300 ng/spot with corresponding correlation coefficients of 0.9944 and 0.9979, for LST and HCTZ, respectively. Both methods were validated, and the results were compared statistically. They were found to be accurate, specific, and reproducible. The methods were successfully applied to the estimation of LST and HCTZ in combined tablet formulations.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏