首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this study, a fast, simple and highly sensitive method that employs liquid phase microextraction (LPME)-GC/MS was developed to analyze trace benzophenones (BPs) in river-water samples. The tip of a 10-microl microsyringe filled with toluene (3 microl) was inserted into 2 ml of a river-water sample, and fixed at 5 mm below the water surface of the sample. A toluene droplet was made on the tip of the syringe, and extraction was conducted while agitating at 500 rpm for 15 min. After extraction, 2.0 microl of the extract was put into the syringe again, and directly introduced to GC/MS. The limits of detection (S/N = 3) and quantification (S/N >10) of BPs were 10 and 50 pg ml(-1), respectively. The results of a recovery test ranged over 93.3 - 101.1% (RSD, less than 10%; n = 6). The results of BPs determinations in the river-water samples showed that BPs (ND - 68.9 pg ml(-1)) were detected.  相似文献   

2.
高效液相色谱法分析生物样品中的敌鼠   总被引:2,自引:0,他引:2  
杨士云  潘冠民  孟广范  张大明 《色谱》2001,19(3):245-247
 研究用阴离子交换、氰基及硅胶柱固相萃取技术分离提取血、尿、肝及肾中的敌鼠。以香豆素作内标 ,用高效液相色谱 二极管阵列检测器方法进行分离鉴定。色谱条件 :分析柱为HypersilBDSC18(5 μm ,15 0mm× 4 6mmi.d .) ,保护柱为PhenomenexODS(4mm× 3 0mmi.d .) ;流动相 :A为 0 5 %离子对A水溶液 ,B为 0 5 %离子对A甲醇溶液 ,以梯度淋洗程序分离 ;检测波长为 2 86nm。当敌鼠的质量浓度在 1mg/L~ 10 0mg/L范围时 ,其浓度同其峰面积与内标物的峰面积之比有良好的线性关系 (r=0 9999) ,最小检出限量为 5ng(按S/N =3计 )。  相似文献   

3.
A simple off-line solid-phase extraction (SPE) method for isolation of polychlorinated biphenyls (PCBs) and selected organochlorine pesticides (OCPs) from human serum has been developed. The procedure includes denaturation of serum proteins by a mixture of water-1-propanol, application of the sample by aspiration twice repeatedly through the SPE column and elution with a mixture of n-hexane-dichlormethane. After final clean-up the compounds of interest were analysed by gas chromatography with micro-electron capture detection (GC-microECD). The recoveries achieved for PCB congeners using spiked porcine serum samples were 99-120% and for OCPs 88-115%. Relative standard deviations (RSD) ranged from 3 to 7%. The method was applied to real human serum samples and the recoveries of analytes in the serum were proportionally recalculated considering the recovery of the internal standard PCB-174. PCB-103 served as a syringe standard to correct volume of samples analysed. The aim of this study was to develop an effective off-line SPE procedure by optimization of existing SPE methods to supply laborious, solvent- and time-consuming liquid-liquid extraction (LLE) in routine analytical process.  相似文献   

4.
A simple device was developed for in-vial liquid-liquid extraction using a polymer membrane (nonporous polypropylene) to separate an aqueous sample from an organic extractant. The membrane consisted of tubing with an internal diameter of 6 mm and a wall thickness of 0.05 mm, which was heat-sealed at the lower end and filled with 500 microl hexane. This membrane bag was incorporated into a conventional 20 ml headspace vial suitable for a multi-purpose sampler (MPS 2, Gerstel, Mülheim, Germany) directly interfaced to a gas chromatograph with a mass-selective detector. The sampler enabled the extraction vial to be mixed at a defined temperature with subsequent large-volume injection of the organic extract taken from the membrane bag. The method was evaluated using several triazines, 2,4-dichloroaniline, alpha-hexachlorocyclohexane and phenanthrene as model compounds. Extraction parameters such as temperature, agitation speed, and extraction time were optimised. Recoveries of 60-90% were achieved after 30 min extraction. By increasing the injection volume to 100 microl, detection limits of 1-10 ng/l were determined.  相似文献   

5.
A new method for determining aflatoxin M1 (AFM1) in cheese by liquid chromatography-tandem mass spectrometry has been developed. Two methodologies were compared for sample extraction. The first one involves sample extraction with dichloromethane for hard, aged cheese or acetone for fresh cheese and includes a preliminary matrix solid-phase dispersion-extraction step before solid-phase extraction (SPE) clean-up by a Carbograph-4 cartridge. The second method uses a water/methanol solution (90:10, v/v) extraction at 150 degrees C before clean-up. The average recoveries of AFM1 from samples spiked at levels of 0.25-0.45 microg/kg, were 81-92% and the precision (RSD) ranged from 3 to 7% with the first method, whilst the average recoveries were 79-84%, and RSD ranged from 7 to 15% for the second method. Due to different matrix effect, the quantification limits were 0.019-0.025 microg/kg in the first case and 0.048-0.143 microg/kg in the second one, depending on cheese typology.  相似文献   

6.
G H Tan 《The Analyst》1992,117(7):1129-1132
Solid-phase extraction (SPE) of organochlorine pesticide residues from environmental water samples was evaluated using octadecyl (C18)-bonded porous silica. The efficiency of SPE of these pesticide residues from reagent water samples at 1-5 micrograms dm-3 levels was compared with those obtained by solvent extraction with hexane and Freon TF (trichlorotrifluoroethane). Average recoveries exceeding 80% for these organochlorine pesticides were obtained via the SPE method using small cartridges containing 100 mg of 40 microns C18-bonded porous silica. The average recovery by solvent extraction with hexane and Freon TF exceeded 90% in both instances. It was concluded that the recoveries and precision for the SPE of organochlorine pesticides were poorer than those for the solvent extraction method. Organochlorine pesticide residue levels in environmental water samples from two major rivers flowing through predominantly rice-growing areas were monitored by gas chromatography using the solvent extraction method with hexane. Exceptionally high levels of organochlorine pesticide residues such as BHC, DDT, heptachlor, endosulfan and dieldrin were found in these water samples.  相似文献   

7.
This paper demonstrates the analysis of levetiracetam, a new chiral antiepileptic drug, at ng/mL levels using an ultra-high-performance liquid chromatography (UHPLC)-photodiode absorbance (PDA) method. Three different sample preparation methods, liquid-liquid extraction with Extrelut, solid phase extraction (SPE) with Oasis HLB and Oasis MAX SPE cartridges, and protein precipitation with organic solvents were carried out. The last preparatory method is the simplest and provides the best recoveries: between 97.1% and 100.4% with RSD value below 5%. The column for separation is BEH C18 column (1.7 μm particle size and 100 × 2.1 mm i.d.) and acetonitrile-phosphate buffer (pH = 6.6; 0.01 M) (10/90 v/v) is the mobile phase. The results obtained are compared to analysis conducted by the HPLC method. The UHPLC method was validated in the range of 2-100 μg/mL levetiracetam concentration (R(2) = 0.9997). LOD and LOQ are 10 ng/mL and 33 ng/mL, respectively. The developed UHPLC method was applied to plasma samples of patient with epilepsy.  相似文献   

8.
Elhamili A  Bergquist J 《Electrophoresis》2011,32(13):1778-1785
In this study, the extraction recoveries of an anticancer drug (Imatinib) from human plasma using a common liquid-liquid extraction (LLE) method and a new strong cation exchange (SCX) solid-phase extraction (SPE) column was investigated. The extracts were analyzed with CE coupled on-line to electrospray ionization (ESI) time-of-flight mass spectrometry (TOF-MS) using a monoquaternarized piperazine compound (M7C4I) for capillary coatings. Clean extracts with high and reproducible extraction recoveries ranging between 85 and 91% with % RSD values of 2.5% (n = 3) were obtained using the SCX-SPE columns. This can be compared with the recoveries obtained with the LLE method ranging between 30 and 35%. The CE-ESI-TOF-MS analysis was performed in <10 min with peak efficiencies up to 4.7 × 10? plates/m and an average % RSD for the repeatability of the migration times of the analytes of 1.9% (n = 3) using acidic buffer and adding 5% ACN to the sample. The calibration curves were linear over the range of 0-1500 ng/mL with correlation coefficient (R2 ≥ 0.997 and % RSD values of 0.5% (n=3). The intra-day and inter-day assay variations were lower than 8%. The presented CE-ESI-TOF-MS method with the use of SCX-SPE columns yielded rapid, efficient and high extraction recoveries together with high sensitivity (LOD 5 ng/mL), selectivity and good linearity. Accordingly, the method can readily be used for accurate determination and therapeutic monitoring of the Imatinib blood levels for more effective patient treatment. In addition, it can be applied for the extraction, quantification and clinical assessments of metabolites of Imatinib and other basic pharmaceutical drug molecules in biological fluids or pharmaceutical dosage forms.  相似文献   

9.
Retinol palmitate (vitamin A, 73.3 microg/g) in an emulsified nutritional supplement was determined by solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) with fluorescence detection (excitation 350 nm, emission 480 nm) using monosodium L-glutamate as a dissolving agent to obtain higher recovery of vitamin A from the emulsified sample solution. A Bond Elut C2 cartridge (500 mg) was chosen for SPE after comparison with 16 other types. A sample solution was applied to a conditioned Bond Elut C2 cartridge and then vitamin A was eluted with ethanol followed by HPLC. The proposed method was simple, rapid (sample preparation time by SPE: ca. 8 min, retention time: ca. 8 min), sensitive [detection limit: ca. 0.1 pg/injection (100 microl) at a signal-to-noise ratio of 3:1], highly selective and reproducible (relative standard deviation (RSD): ca. 2.9% (n = 5), between-day RSD ca. 3.7 (5 days). The recovery of vitamin A was over 90% by the standard addition method.  相似文献   

10.
建立了高效液相色谱-质谱联用技术结合固相萃取和液液萃取方法检测水体和沉积物中12种磷酸酯类(OPEs)化合物残留的方法.水样样品经HLB固相萃取柱富集,乙酸乙酯洗脱两次,沉积物样品以乙腈超声萃取,旋转蒸发至干,用超纯水稀释后重复水样处理步骤,采用ZORBAX Eclipse Plus C18色谱柱(150 mm×2.1 mm, 3.5 μm)进行分离,以0.2%甲酸-甲醇作为流动相进行梯度洗脱,采用正离子MRM监测模式,外标法定量分析.水样中,12种OPEs在0.05、0.10和0.50 μg/L加标水平下,除TMP (28.5%~47.8%)和TEHP (22.4%~73.8%) 外,其余目标化合物的平均回收率为66.4%~115.0%,相对标准偏差为0.5%~9.1%,方法定量限(MOQ)为0.001~0.050 μg/L;沉积物中,在5、10和50 μg/kg加标水平下,除TMP(35.7%~44.9%)、TCEP (31.2%~48.9%)外,其余目标化合物的平均回收率为65.9%~120.0%,相对标准偏差为0.01%~9.5%,方法定量限(MOQ)为0.02~2.0 μg/kg(dw).基于上述方法对太湖水样和沉积物样品中目标化合物定量检测分析,∑OPEs含量分别为0.1~1.7 μg/L和8.1~420 μg/kg dw.  相似文献   

11.
王水  唐琳  郭亦然  颜钫  陈放 《色谱》2001,19(2):128-131
 建立了一个快速、简单、准确的固相萃取和高效液相色谱相结合的测定苦瓜甙A含量的方法。样品经石墨碳固相萃取管 (3mL/ 2 5 0mg)纯化后以高效液相色谱检测。色谱柱为C18,流动相为V(乙腈 )∶V(甲醇 )∶V(5 0mmol/L磷酸二氢钾缓冲液 ) =2 5∶2 0∶6 0 ,流速为 0 .8mL/min ,检测波长为 2 0 8nm。标准曲线自 10mg/L到 10 0 0mg/L呈线形关系 (r2 =0 .9992 )。该方法具有很好的重现性 ,日内或日间的相对标准偏差和相对平均误差均小于 10 %。样品回收率大于 90 %。  相似文献   

12.
固相萃取技术-HPLC测定复方甘草片中吗啡的含量   总被引:9,自引:0,他引:9  
王勇  曾洁 《色谱》1998,16(3):229-231
报道了用SEP-PAKC18小预柱固相萃取技术和反相高效液相色谱法测定复方甘草片中微量吗啡含量的方法。对固相萃取条件进行了研究,最终选择10%甲醇溶液为清洗溶液,70%甲醇溶液为洗脱溶液,基本消除了干扰组分对测定的影响,色谱图背景吸收小,基线平稳。色谱柱为μ-BondapakC18柱,流动相为0.1mol/LNaH2PO4溶液-甲醇(51),检测波长为286nm。平均回收率为(101.2±1.5)%,RSD为1.5%。  相似文献   

13.
A simple, semi-automated, microcolumn solid-phase extraction (SPE) system is optimized for the extraction, preconcentration and HPLC analysis of seven different explosives and explosive derivatives contaminating seawater, river water and well water samples. The microcolumns were constructed from 1/16 in. O.D. PTFE tubing (1 in.=2.54 cm) packed with 0.5-1.5 mg of SPE material. LiChrolut EN or Porapak R. The extraction system consisted of two syringe pumps and several solenoid valves. Optimal detection limits were realized when the sample water flow-rate was maximally increased within the limits of the pump, 5-10 ml/min (despite exceeding the breakthrough threshold of the SPE microcolumn), and when the eluate volume collected from the column was minimized, <5 microl (despite very low recovery percentages).  相似文献   

14.
In this study, the extraction and CE-ESI-TOF-MS analysis of tricyclic antidepressant (TCA) drugs imipramine, desipramine, clomipramine and norclomipramine in human plasma has been optimized. The CE capillaries were modified with ω-iodo-alkyl ammonium salt (M7C4I coating) to reduce analyte adsorption to the silica wall. The use of a strong cation exchange (SCX) solid-phase extraction (SPE) column specifically designed for the extraction of basic drug species from biofluids gave very clean extracts with high and reproducible recoveries. The extraction recoveries were ranging between 87 and 91% with % RSD values of 0.5-1.7% (n=3). The obtained strong cation exchange-SPE extracts of the TCA in human plasma only contained the analytes of interest. The optimized CE separation conditions were obtained by adding ACN and acetic acid to the sample while using an aqueous BGE. The CE-ESI-TOF-MS analysis was performed within 6 min for all TCA analytes under the optimized condition with peak efficiencies up to 1.4 x 10? plates/m and an average % RSD of the migration times of the analytes of 0.3% (n=5). The presented method can readily be used for the extraction and quantification of basic drug species in human biological fluids and in pharmaceutical formulations.  相似文献   

15.
A rapid and reproducible method is described that employs solid-phase extraction (SPE) using dichloromethane, followed by gas chromatography (GC) with flame ionization detection for the determination of benzene, toluene, ethylbenzene, xylene and cumene (BTEXC) from Buriganga River water of Bangladesh. The method was applied to detect BTEXC in a sample collected from the surface, or 5 cm depth of water. Two-hundred milliliters of n-hexane-pretreated and filtered water samples were applied directly to a C18 SPE column. BTEXC were extracted with dichloromethane and the BTEX concentrations were obtained to be 0.1 to 0.37 microg ml(-1). The highest concentration of benzene was found as 0.37 microg ml(-1) with a relative standard deviation (RSD) of 6.2%; cumene was not detected. The factors influencing SPE e.g., adsorbent types, sample load volume, eluting solvent, headspace and temperatures, were investigated. A cartridge containing a C18 adsorbent and using dichloromethane gave a better performance for the extraction of BTEXC from water. Average recoveries exceeding 90% could be achieved for cumene at 4 degrees C with a 2.7% RSD.  相似文献   

16.
An efficient and sensitive method has been established for simultaneous determination of 653 pesticides in teas by GC/MS and HPLC/MS/MS. The method involved extraction with acetonitrile followed by cleanup using Cleanert-TPT SPE and subsequent identification and quantitation of 490 pesticides by GC/MS and 448 pesticides by HPLC/MS/ MS. The LODs for pesticides determined by GC/MS were between 1.0 and 500 microg/kg, and those determined by HPLC/MS/MS were between 0.03 and 4820 microg/kg. At the low fortification levels of 0.01-100 microg/kg, the average recoveries of 94% of the pesticides determined by GC/MS were between 60 and 120%, 77% of which had an RSD below 20%. For 91% of pesticides determined by HPLC/MS/MS, the average recoveries were between 60 and 120%, 76% of which had an RSD below 20%. The paper also reports a novel SPE column, Cleanert TPT, which comprised graphitized carbon black (PestiCarb), polyamine silica, and amide polystyrene for purifying the tea samples. The results indicated good repeatiblity and reproducibility.  相似文献   

17.
Xie SM  Zhang M  Wang ZY  Yuan LM 《The Analyst》2011,136(19):3988-3996
Solid-phase extraction (SPE) is one of the most important techniques for sample preparation, purification, concentration and cleanup. Membranes made from synthetic organic polymers, cellulose, or glass fibers are used for sample pretreatment. In this work, we report that a porous metal membrane, the metal filter in HPLC, was used as a novel kind of solid-phase extraction adsorbent material. To evaluate the performance of the porous metal membrane for the SPE, naphthalene, fluorene, anthracene, phenanthrene, fluoranthene, pyrene, chrysene, perylene and benzo(a)pyrene were selected as analytes. Several parameters that affected the extraction efficiency such as the extraction time, the concentration of NaCl, the extraction temperature and the agitation speed were optimized. The experimental result indicates that the porous metal membrane possesses high adsorption ability to the tested polycyclic aromatic hydrocarbons (PAHs). Under the optimum conditions, the detection limits of the developed method were in the range of 0.03-0.082 μg L(-1) (S/N = 5), and excellent linear correlations between peak area and concentration of PAHs were found over the range of 0.1-60 μg L(-1). The precisions (RSD) for five replicate extractions of the PAHs from sample solutions were in the range of 2.6-5.0%. The recoveries of the PAHs from tap water and river water samples spiked with 9 PAHs (20 μg L(-1) of each individual PAH) ranged from 83.0% to 112.5%. The porous metal membrane is durable, simple, inexpensive, reproducible and has a high adsorption ability for use in SPE of PAHs.  相似文献   

18.
A sensitive and selective confirmatory analytical method for the multi-residue determination of seven quinolones (ciprofloxacin, enrofloxacin, sarafloxacin, danofloxacin, oxolinic acid, nalidixic acid and flumequine) in gilthead seabream (Sparus aurata) was developed. The sample pre-treatment involves extraction with 0.1M NaOH and purification by solid-phase extraction (SPE) on Waters Oasis HLB cartridges followed by the determination of all compounds in a single LC-electrospray ionization MS/MS run. Separation was achieved on a Perfectsil ODS-2, 5mum, 250mmx4mm, analytical column (MZ Analysentechnik) by gradient elution using a mixture of 0.2% (v/v) formic acid, methanol and acetonitrile within 30min. Multiple reaction monitoring (MRM) was used for selective detection of each quinolone. Accuracy was evaluated through recovery studies at three different fortification levels. The mean recoveries are between 90 and 132% for the selected levels with RSD values lower than 20%. The method presents satisfactory results for linearity, precision and limits of quantification. The latter are much lower than the maximum residue limits (MRLs) established by the European Union for quinolones in fish tissues (6-8mug/kg).  相似文献   

19.
Preparations from comfrey (Symphytum officinale and S. x uplandicum) root and leaf contain varying levels of the hepatotoxic pyrrolizidine alkaloids (PAs). Reference compounds for comfrey are not commercially available, and there is currently no rapid extraction or analytical method capable of determining low levels in raw materials or as adulterants in commercially available extracts. A solid-phase extraction (SPE) method was developed using an Ergosil cleanup column that specifically binds the PAs. With this method, powdered comfrey root was extracted by sonication and shaking with basic chloroform. The extract was applied to the cleanup column under vacuum, washed with 2 mL acetone-chloroform (8 + 2, v/v) followed by 2 mL petroleum ether to remove excess chloroform. The column was dried under vacuum, and the PAs were eluted with 2 successive 1 mL aliquots methanol. Percent recoveries of the PAs following Ergosil SPE had an overall average of 96.8%, with RSD of 3.8% over a range of 1.0 to 25.0 g extracted in 100 mL. Average precision of the method (n = 3 over 4 extraction concentrations) gave an overall RSD of 6.0% for the 5 alkaloids, with a range of 0.8% (5 g in 100 mL) to 11.2% (25 g in 100 mL). Recovery optimization testing showed that 1.0 g comfrey root extracted in 100 mL yielded the greatest recovery (% dry weight) of the PAs, with an extraction efficiency and accuracy of 94.2%, and RSD of 1.7% (n = 9). The unique properties of the Ergosil cleanup column provide rapid sample cleanup, volume reduction, and concentration of PAs from comfrey extracts, and allow the eluant to be analyzed directly by traditional chromatographic methods.  相似文献   

20.
The ability of vesicle-coated silica to aid the extraction of organic compounds from water prior to liquid chromatographic analysis is presented for the first time. The method is based on the formation of silica supported cationic multi-lamellar vesicles of gemini surfactants inherently ensuring the presence of hydrophilic and hydrophobic sites for the partitioning of analytes bearing different properties. Method development is illustrated by studying the adsolubilization of UV absorbing chemicals from swimming pool water. Due to the requirement for external energy input (intense shearing) a method based on solid-phase dispersion (SPD) was applied producing better results than off-line solid-phase extraction (SPE). Meticulous investigation of the experimental parameters was conducted in order to elucidate the mechanisms behind the proposed extraction pattern. Analyte recoveries were quantitative under the optimum experimental conditions offering recoveries higher than 96% with RSD values below 5%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号