共查询到20条相似文献,搜索用时 26 毫秒
1.
Gundersen TE Bastani NE Blomhoff R 《Rapid communications in mass spectrometry : RCM》2007,21(7):1176-1186
A high-throughput ultrasensitive analytical method based on liquid chromatography with positive ion atmospheric pressure chemical ionization (APCI) coupled to tandem mass spectrometric detection (LC/MS/MS) was developed for the determination of all-trans-4-oxo-retinoic acid (at4oxoRA), 13-cis-4-oxo-retinoic acid (13c4oxoRA), 13-cis-retinoic acid (13cRA), all-trans-retinoic acid (atRA) and all-trans-retinol (atROH) in human plasma. A stable isotope of atRA was used as internal standard (IS). The analytes and IS were isolated from 100 microL plasma by acetonitrile mono-phase extraction (MPE) performed in black 96-well microtiterplates. A 100 microL injection was focused on-column and chromatographed on an Agilent ZORBAX SB-C18 rapid-resolution high-throughput (RRHT) column with 1.8-microm particles (4.6 mmx50 mm) maintained at 60 degrees C. The initial mobile phase composition was acetonitrile/water/formic acid (10:90:0.1, v/v/v) delivered at 1.8 mL/min. Elution was accomplished by a fast gradient to acetonitrile/methanol/formic acid (90:10:0.1, v/v/v). The method had a chromatographic total run time of 7 min. An Applied Biosystems 4000 Q TRAP linear tandem mass spectrometer equipped with a heated nebulizer (APCI) ionization source was operated in multiple reaction monitoring (MRM) mode with the precursor-to-product ion transitions m/z 315.4-->297 (4-oxo-retinoic acids), 301.2-->205 (retinoic acids), 305.0-->209 (IS) and 269.2-->93 (retinol) used for quantification. The assay was fully validated and found to have acceptable accuracy, precision, linearity, sensitivity and selectivity. The mean extraction recoveries from spiked plasma samples were 80-105% for the various retinoids at three different levels. The intra-day accuracy of the assay was within 8% of nominal and intra-day precision was better than 8% coefficient of variance (CV) for retinoic acids. Inter-day precision results for quality control samples run over a 12-day period alongside clinical samples showed mean precision better than 12.5% CV. The limit of quantification was in the range of 0.1-0.2 ng/mL and the mass limit of detection (mLOD) was in the range 1-4 pg on column for the retinoic acids. The assay has been successfully applied to the analysis of 1700 plasma samples. 相似文献
2.
With the ever-increasing workload from a variety of in vitro and in vivo screening procedures, new analytical methodologies to perform bioanalysis in an accurate and high-throughput manner are in great demand. In this work, monolithic columns were used instead of conventional particulate HPLC columns to perform chromatographic separations. Because the pressure drop on a monolithic column was considerably lower than that on a particulate column, a high flow rate (6 mL/min) was used for a 4.6 x 50 mm monolithic column with a total backpressure of about 61 bar measured using acetonitrile/water (50:50). The capability of using a regular column length at high flow rates, combined with the extremely small dependency of separation efficiency on linear flow velocity, allowed for the generation of sufficient chromatographic resolving power in a significantly reduced runtime. As demonstrated in this work, a plasma extract of a mixture of tempazepam, tamoxifen, fenfluramine, and alprozolam were baseline separated within a total analysis time of one minute. An average peak width at half maximum of approximately one second was noted using a generic broad gradient. It was also found that the separation efficiency and signal/noise (S/N) ratios for this separation remained almost constant at flow rates of 1, 3, and 6 mL/min, respectively. The ruggedness of the separation was evaluated by injecting 600 plasma extracts containing the replicates of a standard curve of the above mixture during an overnight run. The chromatographic retention time, separation quality, peak response and sensitivity were highly reproducible throughout the run. This high-speed liquid chromatography/tandem mass spectrometry (LC/MS/MS) system has been used routinely in the authors' laboratory to support drug discovery programs. 相似文献
3.
Storme ML Jansen FH Goeteyn W Van Bocxlaer JF 《Rapid communications in mass spectrometry : RCM》2006,20(19):2947-2953
The work presented here deals with the development of a quantitative tool for the simultaneous determination of sulfamethoxypyrazine (sulfalene)/pyrimethamine in plasma. The chromatography used only takes 12.5 min, allowing a fast sample turnover time. Relative standard deviation of retention times was never above 3.48% (n = 66). Adequate sample clean-up was achieved by a simple and relatively fast liquid/liquid extraction. In this way, ionisation suppression effects, typical for more simple sample clean-up procedures, could be avoided resulting in absolute plasma effects of maximum -17.1% for sulfalene, -16.1 for the internal standard (IS), and 12% for pyrimethamine. For both pyrimethamine and sulfalene, quadratic calibration curves from 0.00101 to 0.807 microg/mL for pyrimethamine and from 0.271 to 216 microg/mL for sulfalene gave the best fit. Mean coefficients of determination (R2) were 0.9951 (n = 6, CV% 0.39) for pyrimethamine and 0.9942 (n = 6, CV% 0.13) for sulfalene. Precision was below 9.35% for pyrimethamine and 13.9% for sulfalene. Inaccuracy remained below 15% at all cases. The optimised method was used for a time-course study of the sulfalene/pyrimethamine combination concentration in plasma of patients treated with Co-Arinate, a new curative antimalaria-medicine. 相似文献
4.
Armaghan Shafaei Kevin Croft Jonathan Hodgson Mary C. Boyce 《Journal of separation science》2019,42(18):2909-2921
A diet rich in polyphenolic compounds has recognized health benefits, and as such is routinely monitored as part of dietary intervention studies. A method for the simultaneous determination of 36 phenolic compounds, including phenolic acids and flavonoids, using liquid chromatography and tandem mass spectrometry is described here. The target analytes were quantified based on their specific mass spectral fragments using a selected reaction monitoring approach. A C18 column with embedded aromatic functionality ensured separation of all phenolic compounds studied which included several pairs of isomers. Sample preparation involved the use of β‐glucuronidase to release the phenolic compounds from their conjugated forms. The intra‐day and inter‐day precision and accuracy was less than 7% for all phenolic compounds studied. Recoveries, where plasma was spiked with three different concentrations of the analytes, ranged from 95–115%. The limits of detection and quantification were 0.23–3.89 and 1.15–7.79 nM, respectively. The method was successfully applied to real samples and the range reported for each phenolic compound, with the exception of hydroferulic acid, nordihydroguaiaretic acid, methylgallate, and m‐coumaric acid, was at least an order of magnitude higher than the limit of quantification for the method. 相似文献
5.
A high-throughput monoamine oxidase inhibition assay using liquid chromatography with tandem mass spectrometry 总被引:1,自引:0,他引:1
Yan Z Caldwell GW Zhao B Reitz AB 《Rapid communications in mass spectrometry : RCM》2004,18(8):834-840
A highly efficient method utilizing liquid chromatography with tandem mass spectrometry (LC/MS/MS) was developed and employed for high-throughput screening of compounds for monoamine oxidase (MAO) inhibition. The method used kynuramine as a common substrate for both MAO-A and MAO-B in incubations, and the 4-hydroxyquinoline (4-HQ) resulting from deamination of kynuramine followed by intramolecular condensation was analyzed using LC/MS/MS; formation of 4-HQ was used as the marker of MAO activity to evaluate the effects of test compounds. Isocratic liquid chromatography was applied to reduce the run time to 2 min. Because of the high specificity and sensitivity of detection of 4-HQ by LC/MS/MS, this method was able to use MAO enzymes at very low concentrations and to perform short incubations; as a result, consumable cost was minimized, and sample preparations were completely avoided. The inhibition data are highly reproducible, and the IC(50) values determined by the method are in good agreement with literature values. The results suggest that this method is very robust and can be used as a generic approach to screen for MAO inhibitors in drug discovery. 相似文献
6.
Xia YQ Whigan DB Powell ML Jemal M 《Rapid communications in mass spectrometry : RCM》2000,14(2):105-111
As a continuation of our efforts to improve our high-flow on-line bioanalytical approach for high-throughput quantitation of drugs and metabolites in biological matrices by high-performance liquid chromatography (LC) and tandem mass spectrometry (MS/MS), we have developed a ternary-column on-line LC/MS/MS system with dual extraction columns used in parallel for purification and an analytical column for analysis. The advantage of the dual extraction column system is that sample analysis can take place in one of the extraction columns while the other column is being equilibrated. Thus, the equilibration time does not add to the run time, hence shortening the injection cycle time and increasing the sample throughput. Moreover, the use of two extraction columns in parallel increases the number of samples that can be injected before the system fails due to an overused extraction column. Such a system has successfully been used to develop and validate a positive ion electrospray LC/MS/MS bioanalytical method for the quantitative determination of a guanidine-containing drug candidate in rat plasma. The system used for this work utilized two Oasis HLB extraction columns (1 x 50 mm, 30 microm), one C18 analytical column (3.9 x 50 mm, 5 microm), a ten-port switching value and a tandem mass spectrometer. The on-line analysis was accomplished by the direct injection of 10 microL of the sample, obtained by mixing a rat plasma sample 1:1 with an aqueous internal standard solution. Selected reaction monitoring (SRM) was utilized for the detection of the analyte and internal standard. The standard curve range was 1.00-200 ng/mL. The intra- and inter-day precision and accuracy were within 6.6%. The on-line purification step lasted for only 0.3 min and total run time was only 1.6 min. 相似文献
7.
C. Chassaing J. Luckwell P. Macrae K. Saunders P. Wright R. Venn 《Chromatographia》2000,53(3-4):122-130
Summary Turbulent flow chromatography coupled to tandem mass spectrometry (TFC-MS-MS) has recently emerged as a potentially fast,
sensitive and specific technique for the direct analysis of pharmaceutical compounds from crude plasma. TFC-MS-MS removes
the need for time-consuming sample preparation procedures such as solid-phase extraction (SPE) or liquid-liquid extraction
(LLE). A relatively high flow rate combined with the use, of an HPLC column with large porous particles allows the on-line
clean up and quantification of compounds in plasma samples. Until, now, the amount of plasma directly injected into TFC systems
has rarely exceeded 30 μL in order to prevent rapid column degradation. Increasing the injection volume also induces high
carry-over levels, particularly for drugs with basic and/or lipophilic properties.
This paper describes the first genetic TFC-MS-MS method developed in a 96-well format, which allows the direct injection of
200 μL of 1∶1 diluted plasma (equivalent to 100 μL neat plasma). An average, of 390 injections was carried out with each extraction
column. More than 2000 dog plasma samples were injected into the system without any sign of carryover. The method was fully
validated over a 5–500 ng mL−1 range for three basic compounds: doxazosin, CP122,288 and dofetilide. The imprecision was 1.2 to 8.3% for doxazosin, 1.5
to 4% for CP122,288 and 1.6 to 9.2% for dofetilide. The inaccuracy ranged from 6% to 7.9%. This generic methodology was then
used to assay two structurally unrelated development compounds, showing that the method accuracy and sensitivity were adequate
for the early pharmacokinetic (PK) studies in animals. 相似文献
8.
Quantitative analysis of docetaxel in human plasma using liquid chromatography coupled with tandem mass spectrometry 总被引:2,自引:0,他引:2
Kuppens IE van Maanen MJ Rosing H Schellens JH Beijnen JH 《Biomedical chromatography : BMC》2005,19(5):355-361
An assay for the quantitative determination of docetaxel in human plasma is described. Docetaxel was extracted from the matrix using liquid-liquid extraction with ter-butylmethylether, followed by high-performance liquid chromatographic analysis using an alkaline eluent. Paclitaxel was used as internal standard. Positive ionization electrospray tandem mass spectrometry was performed for selective and sensitive detection. The method was validated according to the FDA guidelines on bioanalytical method validation. The validated range for docetaxel was from 0.25--1000 ng/mL using 200 microL plasma aliquots. The method requires only a limited volume (200 microL) of human plasma and the method can be applied in studies requiring a low lower limit of quantitation of 0.25 ng/mL. The assay was applied successfully in several clinical and pharmacological studies with docetaxel. 相似文献
9.
Castro-Perez J Plumb R Liang L Yang E 《Rapid communications in mass spectrometry : RCM》2005,19(6):798-804
Chemically reactive metabolites may cause hepatotoxicity and as a result liver failure or other adverse side reactions. Therefore, this is a vital topic of interest because early reactive metabolite screening may prevent compound failure at a later stage. In order to address this issue, a screening assay has been developed to detect the formation of reactive metabolites by using glutathione as a trapping reagent, which will allow us to search for phase I metabolites and also glutathiones during in vitro metabolite screening using liquid chromatography/tandem mass spectrometry (LC/MS/MS) with exact mass. Glutathione conjugations when fragmented by the mass spectrometer give a common loss corresponding to the pyroglutamic acid moiety, which can be monitored. Until recently, this work has been carried out with triple quadrupole technology using nominal mass. The advantage of the hybrid quadrupole time-of-flight mass spectrometer is the selectivity and sensitivity that can be achieved. Exact neutral loss detection is achieved via sequential low- and high-energy MS acquisitions. After detection of the loss of the pyroglutamic acid moiety, using a window of +/-20 mDa on the high-energy scan, MS/MS is carried out on the parent mass of interest to confirm the common neutral loss. 相似文献
10.
Lakhani NJ Lepper ER Sparreboom A Dahut WL Venitz J Figg WD 《Rapid communications in mass spectrometry : RCM》2005,19(9):1176-1182
A liquid chromatography/tandem mass spectrometric (LC/MS/MS) assay was developed for the quantitative determination of 2-methoxyestradiol (2ME2) in human plasma. Sample pretreatment involved liquid-liquid extraction with ethyl acetate of 0.3-mL aliquots of plasma spiked with the internal standard, deuterated 2ME2 (2ME2-d5). Separation was achieved on a Zorbax Eclipse C18 column (2.1 x 50 mm, i.d., 5 microm) at room temperature using a gradient elution with methanol and water at a flow rate of 0.25 mL/min. Detection was performed using atmospheric pressure chemical ionization MS/MS by monitoring the ion transitions from m/z 303.1 --> 136.8 (2ME2) and m/z 308.1 --> 138.8 (2ME2-d5). Calibration curves were linear in the concentration range of 1-100 ng/mL. The accuracy and precision values, obtained from three different sets of quality control samples analyzed in quintuplicate on four separate occasions, ranged from 105-108% and from 3.62-5.68%, respectively. This assay was subsequently used for the determination of 2ME2 concentration in plasma of a patient with cancer after a single oral administration of 2ME2 at a dose of 2200 mg. 相似文献
11.
Acetaminophen (APAP) is a widely used analgesic and antipyretic drug. It is mainly metabolized by phase 1 and 2 reactions in the liver, and thus it could be involved in many drug–drug interactions. Therefore, the study of APAP metabolism is important in toxicological and pharmacokinetic studies. The objective of this study was to develop a rapid and sensitive method for the determination of APAP and its six metabolites in rat plasma for the pharmacokinetic studies. APAP and its metabolites were separated through a Capcell Pak MGII C18 column and quantitated with a 16 min run in a triple‐quadruple mass spectrometer. The mobile phases were composed of 0.1% formic acid in either 95% water or 95% acetonitrile and analysis was performed twice in positive and negative modes. Validations such as accuracy, precision, recovery, matrix effect and stability were found to be within acceptance criteria of validation guidelines, indicating that the assay was applicable to the determination of the plasma concentrations of drug and its six metabolites. In conclusion, we developed an LC‐MS/MS method for the quantitative analysis of APAP and its six metabolites in rat plasma, and this method appears to be useful for pharmacokinetic/toxicokinetic studies of APAP and its metabolites in rats. Copyright © 2012 John Wiley & Sons, Ltd. 相似文献
12.
Luo Y Uboh CE Soma LR Guan FY Rudy JA Tsang DS 《Rapid communications in mass spectrometry : RCM》2005,19(10):1245-1256
A method for the simultaneous separation, identification, quantification and confirmation of the presence of 21 glucocorticoids (GCC) in equine plasma by liquid chromatography coupled with triple stage quadrupole tandem mass spectrometry (LC/TSQ-MS/MS) is described. Plasma sample augmented with the 21 GCC was extracted with methyl tert-butyl ether (MTBE) and analyzed by positive electrospray ionization. Desoxymetasone or dichlorisone acetate was used as the internal standard (IS). Quantification was performed by IS calibration. For each drug, one major product ion was chosen and used for screening for that drug. Analyte confirmation was performed by using the three most intense product ions formed from the precursor ion and the corresponding mass ratios. The recovery of the 21 GCC when spiked into blank plasma at 5 ng/mL was 45-200% with coefficient of variation (CV) from 0.3-18%. The limit of detection (LOD) and that of quantification (LOQ) for most of the analytes were 50-100 pg/mL and 1 ng/mL, respectively, whereas that of confirmation (LOC) was 100-300 pg/mL depending on the analyte. Intra- and inter-day precisions expressed as CV for quantification of 1 and 10 ng/mL was 1.0-17%, and 0.51-19%, respectively, and the accuracy was from 84-110%. The linear concentration range for quantification was 0.1-100 ng/mL (r(2) > 0.997). Estimated measurement uncertainty was from 11-37%. This study was undertaken to develop a method for simultaneous screening, identification, quantification and confirmation of these agents in post-race equine plasma samples. The method has been successfully applied to screening of a large number of plasma samples obtained from racehorses in competition and in pharmacokinetic studies of dexamethasone in the horse and concurrent changes in endogenous GCC, hydrocortisone and cortisone. The method is simple, sensitive, selective and reliably reproducible. 相似文献
13.
Chiral liquid chromatography is a well-established area of bioanalytical chemistry and is often used during the processes of drug discovery and development. The development and use of a chiral drug require the understanding of the pharmacokinetic characteristics of each of the enantiomers, including potential differences in their absorption, distribution, metabolism, and excretion. Chromatographic techniques coupled to atmospheric pressure ionization-tandem mass spectrometry have shown potential as sensitive and robust tools in the quantitative and qualitative determination of enantiomers in biologic fluids and tissue extracts. However, development of a chiral liquid chromatography method requires time-consuming procedures that are devised empirically. Clearly, there is an incentive to design chromatographic approaches that are easy to use, compatible with mass spectrometry ionization interface conditions, exhibit relatively short run times without compromising sensitivity, and offer a broad analyte specificity. For these reasons, the present paper explores the feasibility of the bonded macrocyclic glycopeptide phases (teicoplanin and vancomycin) for analysis by chiral liquid chromatography/tandem mass spectrometry. Ritalinic acid, pindolol, fluoxetine, oxazepam, propranolol, terbutaline, metoprolol, and nicardipine were tested in this study. Furthermore, an example of a simultaneous chiral LC/MS/MS detection (chromatographic run time approximately 10 min) of four pharmaceutical products resulting in baseline resolutions of all four pairs of enantiomers is presented. Methanol, an MS-compatible mobile phase, was utilized in all the experiments. 相似文献
14.
Vainchtein LD Thijssen B Stokvis E Rosing H Schellens JH Beijnen JH 《Biomedical chromatography : BMC》2006,20(1):139-148
A sensitive and specific LC-MS/MS assay for the determination of paclitaxel and its 3'p- and 6-alpha-hydroxy metabolites is presented. A 200 microL plasma aliquot was spiked with a 13C6-labeled paclitaxel internal standard and extracted with 1.0 mL tert-butylmethylether. Dried extracts were reconstituted in 0.1 M ammonium acetate-acetonitrile (1:1, v/v) and 25 microL volumes were injected onto the HPLC system. Separation was performed on a 150 x 2.1 mm C18 column using an alkaline eluent (10 mm ammonium hydroxide-methanol, 30:70, v/v). Detection was performed by positive ion electrospray followed by tandem mass spectrometry. The assay quantifies a range for paclitaxel from 0.25 to 1000 ng/mL and metabolites from 0.25 to 100 ng/mL using 200 microL human plasma samples. Validation results demonstrate that paclitaxel and metabolite concentrations can be accurately and precisely quantified in human plasma. This assay is now used to support clinical pharmacologic studies with paclitaxel. 相似文献
15.
Generic serial and parallel on-line direct-injection using turbulent flow liquid chromatography/tandem mass spectrometry 总被引:1,自引:0,他引:1
Grant RP Cameron C Mackenzie-McMurter S 《Rapid communications in mass spectrometry : RCM》2002,16(18):1785-1792
The development of turbulent flow chromatography (TFC) has enabled considerable growth in the utility of on-line direct-injection technologies. TFC has now become established in a large number of varied analytical environments, particularly drug discovery/pharmacokinetics, metabolite profiling, combinatorial library purification, pre-clinical and clinical GLP applications. The utility of turbulent flow technology for in-house pre-clinical and clinical quantitative applications has necessitated extensive valve-cleaning procedures, and consequently lengthy cycle-times, to effectively remove the system carry-over. In-house requirements for assay validation require carry-over less than 20% of the lowest level of quantification (LLOQ), corresponding to 0.02% carry-over for a linear calibration range incorporating 3 orders. A generic turbulent flow chromatography protocol has been developed for drug discovery that incorporates polymeric turbulent flow extraction (cyclone) with C18-based reverse-phase chromatography. Further, multiple wash steps are incorporated within the methodology to meet in-house requirements for carry-over. Selection of novel switching-valve materials based on polyarylethyl ketone (PAEK) and Hastelloy/Valcon E autosampler injection hardware has enabled us to significantly impact the cycle-time required to reduce carry-over. Consequently, optimal usage of switching valves has enabled parallel operation for a generic on-line direct-injection methodology to successfully reduce the total cycle-time. Overall reductions from 4 min per sample to 90 s per sample are shown with comparable data quality using a proprietary target molecule from 0.1-100 ng/mL. This paper describes the hardware configuration and methodologies utilized to perform generic serial and parallel on-line direct-injection using a Turboflow HTLC 2300 system. 相似文献
16.
O'Brien-Coker IC Perkins G Mallet AI 《Rapid communications in mass spectrometry : RCM》2001,15(12):920-928
This paper describes the development of a high performance liquid chromatography/tandem mass spectrometric (MS/MS) procedure for the specific qualitative and quantitative analysis of lipid aldehydes in biological matrices. A derivatisation method, which results in molecules that exhibit a common product ion on MS/MS, permits informative precursor ion scans, at high sensitivity. This has been applied to the examination of plasma in order to examine the production of aldehydes consequent on in vitro lipid oxidation. Quantitative analysis of target molecules using multiple reaction monitoring has been developed to permit quantitation in the same matrices. 相似文献
17.
Thevis M Bredehöft M Geyer H Kamber M Delahaut P Schänzer W 《Rapid communications in mass spectrometry : RCM》2006,20(23):3551-3556
Synacthen is a synthetic analogue to human adrenocorticotropin, which plays an important physiological role by stimulating production of cortisol. In sports, corticosteroids as well as releasing factors (corticotropins) are prohibited according to the regulations of the World Anti-Doping Agency, and the misuse of Synacthen has been reported several times. Hence, an assay enabling the detection of Synacthen in doping control samples has been developed using immunoaffinity chromatographic isolation of Synacthen from human plasma combined with a concentration of collected fractions using solid-phase extraction. Unambiguous determination of the target analyte was accomplished using microbore liquid chromatography/electrospray ionization tandem mass spectrometry. Diagnostic product ions such as m/z 223 were characterized using high-resolution/high-accuracy Orbitrap mass spectrometry and employed for triple quadrupole MS/MS analysis. The established assay requiring 2 mL of plasma allowed a lower limit of detection (LLOD) at 100 fmol/mL, a recovery of 97% and a precision at the LLOD < 20%. Authentic plasma samples obtained from a patient undergoing a standard short Synacthen test were used to prove the applicability of the developed procedure. 相似文献
18.
Kapron J Wu J Mauriala T Clark P Purves RW Bateman KP 《Rapid communications in mass spectrometry : RCM》2006,20(10):1504-1510
A liquid chromatography/high-field asymmetric waveform ion mobility spectrometry/tandem mass spectrometry (LC-FAIMS-MS/MS) semi-quantitative method was developed for the simultaneous determination of prostaglandin (PG) E2, PGD2, PGF(2alpha), 6-keto-PGF(1alpha), and thromboxane (TX) B2. Diluted samples containing these prostanoids and their tetra-deuterium-substituted internal standards were analyzed by LC followed by either selected reaction monitoring (LC-SRM) or FAIMS and selected reaction monitoring (LC-FRM). FAIMS reduced background noise, separated the isobaric ions PGE2 and PGD2, and separated dynamically interchanging TXB2 anomers. This is the first report of the separation of interconverting anomers by FAIMS. Generally, the LC-FRM chromatograms were more selective than the LC-SRM chromatograms. Its potential was demonstrated by analysis of prostanoids in guinea pig lumbar spinal cord homogenate. 相似文献
19.
A rapid analytical method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) using electrospray ionization in negative ion detection mode was developed for the analysis of underivatized iodoacetic acid in water. The method was applied to model reaction mixtures in the study of the formation of iodoacetic acid after chlorinated tap water was boiled in the presence of potassium iodide or iodized table salt. Samples can be directly analyzed by the LC/MS/MS system without extraction or chemical derivatization. Limit of detection was determined to be 0.3 microg/L (or 0.3 ng/mL) and limit of quantitation was about 1 microg/L (1 ng/mL). 相似文献