首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The present work describes the development and optimization of a capillary (zone) electrophoresis/mass spectrometric (CE/MS) analysis method for polar hydrophilic aromatic sulfonates (ASs). The compounds were detected by negative ion electrospray ionization (NIESI) and selected ion monitoring (SIM). In comparison with CE/UV, for CE/MS a lower-concentration volatile ammonium acetate buffer (5 mM) without organic modifier and a higher separation voltage were better suited for separation. Sensitivity of CE/MS was slightly better than for CF/UV, with the limit of detection (LOD) ranging between 0.1 and 0.4 mg l(-1). For verification of the CE/MS results, ASs were also analysed by ion-pair liquid chromatography/diode array UV detection coupled in series with electrospray mass spectrometry (IPC/DAD/ESI-MS). Real water samples of different waste water treatment plants (WWTPs) in Catalonia (NE Spain) were extracted by solid-phase extraction (SPE) with LiChrolut EN and analysed with CE/MS and LC/MS. ASs were found in influent and effluent water samples of the WWTPs in the microg l(-1) concentration range. LC/MS offered a higher separation efficiency and sensitivity than CE/MS. Therefore with LC/MS more compounds could be identified in the WWTPs. The persistency of the ASs was distinct: some compounds were well degraded during the water treatment process, while others were quite persistent.  相似文献   

2.
In this work, a combined methodology using off-line solid-phase extraction (SPE), on-line field-enhanced sample injection (FESI) and coelectroosmotic capillary electrophoresis with UV detection (CE-UV) is developed for the trace analysis of five triazolopyrimidine sulfonanilide pesticides (i.e., flumetsulam, florasulam, cloransulam-methyl, diclosulam and metosulam). An adequate background electrolyte (BGE) was obtained for the separation of these pesticides using hexadimethrine bromide (HDB) as electroosmotic flow (EOF) modifier. This BGE consisted of 0.00042% HDB, 11 mM formic acid, 16 mM ammonium carbonate and 2.5 mM alpha-CD solution at pH 7.6. The use of this running buffer together with the FESI preconcentration method provided limits of detection (LODs) in the low microg/L range (i.e., between 13.0 and 31.5 microg/L). The optimized FESI-CE-UV method was combined with off-line SPE using C(18) cartridges and applied to the determination of the selected group of pesticides in soil samples. Recovery percentages ranged between 50 and 84% in these samples with LODs between 18 and 34 microg/kg. This work shows the great possibilities of the combined use of SPE-FESI-CE-UV to improve CE sensitivity allowing the achievement of LODs similar to other analytical techniques as GC or HPLC.  相似文献   

3.
This paper describes two different approaches for increasing the sensitivity for the analysis of ceftiofur by capillary electrophoresis (CE). Two different techniques based on the introduction of an enlarged volume of sample, namely large volume sample stacking (LVSS) and in-line solid phase extraction (SPE) were studied and compared. LVSS allowed the on-column electrophoretic preconcentration of ceftiofur without modification of the separation capillary. In-line SPE-CE was developed by using a home-made microcartridge that was filled with a reversed-phase sorbent (C18). The microcartridge was coupled in-line near the inlet of the separation capillary. LVSS and in-line SPE-CE allowed automated operation and improved sensitivity for the analysis of ceftiofur with respect to conventional CE. When environmental water samples were analyzed, an additional pretreatment step based on off-line SPE was necessary in both cases to further decrease the detection limits. In terms of sensitivity for the determination of ceftiofur in river water samples, the combination of off-line SPE with in-line SPE-CE was found the most sensitive with a detection limit of 10 ng L−1, whereas the method based on the use of off-line SPE with LVSS presented a detection limit of 100 ng L−1.  相似文献   

4.
A method for the determination of cyclamate in food was developed using solid-phase extraction (SPE) and capillary electrophoresis (CE) with indirect ultraviolet (UV) detection. A 5-10 g sample in 0.1 mol/L hydrochloric acid was homogenized and made up to a volume of 50 mL with 0.1 mol/L hydrochloric acid. After the sample was centrifuged, 25 mL of supernatant was loaded into an Oasis HLB SPE cartridge. The cartridge was washed with 2 mL of demineralized water followed by 2 mL of 50% aqueous methanol, and cyclamate was eluted with 4.5 mL of 50% aqueous methanol. The eluate was added to a solution of sodium propionate (internal standard) for CE analysis. The cyclamate in the eluate was electrophoresed on a fused-silica capillary using 1 mmol/L hexadecyltrimethylammonium bromide and 10 mmol/L potassium sorbate as a running buffer. Detection and reference wavelengths of cyclamate determined with a UV detector were 300 and 254 nm, respectively. The calibration curves for cyclamate showed good linearity in the range of 2-1000 microg/mL and the limits of detection in beverage, fruit in syrup, jam, pickles and confectionary are sample dependent and ranged from 5-10 microg/g. The recovery of cyclamate added at a level of 200 microg/g to various kinds of foods was 93.3-108.3% and the relative standard deviation was less than 4.9% (n=3). A number of commercial samples were analyzed using the proposed method. Cyclamate was detected in one waume, two pickles, and two sunflower seeds. The quantitative values determined with CE correlated to those from high-performance liquid chromatography (HPLC) (the detected values of cyclamate in a sunflower seed measured by CE and HPLC were 3.40 g/kg and 3.51 g/kg, respectively). This analytical method for cyclamate using CE is especially suitable for use in the field.  相似文献   

5.
A field-amplified sample injection–capillary zone electrophoresis (FASI-CZE) method for the analysis of benzophenone (BP) UV filters in environmental water samples was developed, allowing the separation of all compounds in less than 8 min. A 9- to 25-fold sensitivity enhancement was obtained with FASI-CZE, achieving limits of detection down to 21–59 μg/L for most of the analyzed BPs, with acceptable run-to-run and day-to-day precisions (relative standard deviations lower than 17 %). In order to remove water sample salinity and to enhance FASI sensitivity, an off-line solid-phase extraction (SPE) procedure using a Strata X polymeric reversed-phase sorbent was used and afforded recoveries up to 72–90 % for most BPs. With the combination of off-line SPE and FASI-CZE, limits of detection in the range 0.06–0.6 μg/L in a river water matrix, representing a 2,400- to 6,500-fold enhancement, were obtained. Method performance was evaluated by quantifying a blank river water sample spiked at 1 μg/L. For a 95 % confidence level, no statistical differences were observed between found concentrations and spiked concentrations (probability at the confidence level, p value, of 0.60), showing that the proposed off-line SPE-FASI-CZE method is suitable for the analysis of BP UV filters in environmental water samples at low microgram per liter levels. The method was successfully applied to the analysis of BPs in river water samples collected up- and downstream of industrialized and urban areas, and in some drinking water samples.  相似文献   

6.
Zhu Z  Zhang L  Marimuthu A  Yang Z 《Electrophoresis》2002,23(17):2880-2887
A simple, quick, and sensitive capillary electrophoretic technique-large volume stacking using the electroosmotic flow (EOF) pump (LVSEP) - has been developed for determining ethylenediaminetetraacetic acid (EDTA) in drinking water for the first time. It is based on a precapillary complexation of EDTA with Fe(III) ions, followed by large-volume sample stacking and direct UV detection at 258 nm. The curve of peak response versus concentration was linear from 5.0 to 600.0 microg/L, and 0.7 to 30.0 mg/L. The regression coefficients were 0.9988 and 0.9990, respectively. The detection limit of the current technique for EDTA analysis was 0.2 microg/L with an additional 10-fold preconcentration procedure, based on the signal-to-noise ratio of 3. As opposed to the classical capillary zone electrophoresis (CE) method, the detection limit was improved about 1000-fold by using this LVSEP method. To the best of our knowledge, it represents the highest sensitivity for EDTA analysis via CE. Several drinking water samples were tested by this novel method with satisfactory results.  相似文献   

7.
This paper deals with comparison of efficiency of extraction techniques (solid-phase extraction, SPE and solid-phase microextraction, SPME) used for extraction of nitrate esters (ethyleneglycoldinitrate, EGDN and nitroglycerin, NG), representing the first step of the method of quantitative determination of trace concentrations of nitrate esters in water samples. EGDN and NG are subsequently determined by means of high-performance liquid chromatography with ultraviolet detection (HPLC-UV). Optimization of SPE and SPME conditions was carried out using model water samples. Seven SPE cartridges were tested and the conditions were optimized (type of sorbent, type and volume of solvent to be used as eluent). For both nitrate esters the limit of detection (LOD) and the limit of quantification (LOQ) obtained using SPE/HPLC-UV were 0.23 microg mL(-1) and 0.70 microg mL(-1), respectively. Optimization of SPME conditions: type of SPME fibre (four fibres were tested), type and time of sorption/desorption, temperature of sorption. PDMS/DVB (polydimethylsiloxane/divinylbenzene) fibre coating proved to be suitable for extraction of EGDN and NG. For this fibre the LOD and the LOQ for both nitrate esters were 0.16 microg mL(-1) and 0.50 microg mL(-1), respectively. Optimized methods SPE/HPLC-UV and SPME/HPLC-UV were then used for quantitative determination of nitrate esters content in real water samples from the production of EGDN and NG.  相似文献   

8.
A method based on capillary zone electrophoresis coupled with photodiode-array detection has been developed to determine several sulfonated dyes, including a sulfonated dye (acid yellow 1), and the sulfonated azo dyes acid orange 7, acid orange 12, acid orange 52, acid red 26, acid red 27 and acid red 88. A CElect-FS75 CE column is used. The electrophoresis buffer contains a 1:5 dilution of 10 mM phosphoric acid and tetrabutylammonium hydroxide buffer (pH 11.5), and 25 mM of triethylamine, the final pH being 11.55. The detection limits for the seven dyes ranged from 0.1 to 4.53 microg/ml. Spiked river water samples (100 ml), containing different concentration levels (0.025-0.150 microg/ml) of the dyes were analyzed after acidification (pH 3) and pre-concentration in disposable SPE Oasis HLB, 1 ml cartridges.  相似文献   

9.
A fully automated method is presented for the determination of acidic drugs in urine and serum using on-line dialysis-solid-phase extraction (SPE)-capillary electrophoresis (CE) with UV detection. With non-steroidal anti-inflammatory drugs (NSAIDs) as test compounds, detection limits in the biological samples were 0.05-1.0 microgram ml-1. Calibration plots were linear over two orders of magnitude and the within-day and between-day repeatability were better than 10%. The CE capillary and SPE column were used for over 500 analyses; the dialysis membrane was replaced after 250 analyses. A general protocol for dialysis-SPE-CE which can be used for amphoteric and acidic drugs was devised. The present results show that this protocol has general validity and can be recommended for future work on other classes of drugs.  相似文献   

10.
A sensitive and reliable method using capillary zone electrophoresis with UV-diode array detection (CZE-DAD) has been developed and validated for trace determination of beta-lactam antibiotics in waste, well and river water matrices. Due to the lack of sensitivity of the UV-vis detection, a solvent extraction/solid-phase extraction (SPE) method applied for off-line preconcentration and cleanup of water samples, in combination with an on-line preconcentration methodology named large volume sample stacking (LVSS) have been applied. The analytes included nafcillin, dicloxacillin, cloxacillin, oxacillin, ampicillin, penicillin G and amoxicillin. Average recoveries for water samples fortified with the studied beta-lactams at different concentration levels (1.0, 2.0 and 4.0 microg/L) were ranging between 94 and 99%, with relative standard deviations (RSDs) lower than 10%. The precision, calculated as intra-day and inter-day standard deviations fell within acceptable ranges (3.3-7.2%). The limits of detection were estimated to range between 0.08 and 0.80 microgL(-1) for the studied compounds. All the samples analyzed were negative for all the analytes at these levels of concentration and the method showed its usefulness for the detection of these widely applied beta-lactam antibiotics in different kinds of waters.  相似文献   

11.
Fung YF  Lau KM 《Electrophoresis》2001,22(11):2192-2200
A new analytical procedure is developed using a strong complexing agent, 1,10-phenanthroline (Phen), for direct UV detection of Zn, Mn, Cu, Co, Cd, and Fe at microg/L concentrations in environmental water samples. The metal chelates formed showed different electrophoretic mobilities and solved the comigration problem for capillary electrophoresis (CE) separation of free metal ions. To obtain stable metal-Phen chelates during the capillary zone electrophoresis (CZE) run, both pre-column and on-column complexation are required and threefold excess of Phen over metal ions should be added to the sample. The optimized background electrolyte (BGE) consists of 30 mM hydroxylamine hydrochloride and 0.1% methanol at pH 3.6. Under hydrodynamic sampling, CE run at + 20 kV in 65 cm x 0.05 mm ID fused-silica column with detection at 265 nm, baseline separation, satisfactory working ranges (10 microg/L to 5.5 mg/L), sensitive detection limits (1-3 microg/L), good repeatability for migration times (relative standard deviation, RSD 0.36-0.81%, n = 5), peak area (RSD 3.2-4.2%, n = 5) and peak height (RSD 3.2-4.5%, n = 5) were obtained for the metal cations investigated. The reliability of the method was established by parallel determination using the inductively coupled plasma-atomic emission spectrometry (ICP-AES) method giving results within statistical variation. The procedure developed is shown to provide a quick, sensitive, precise, and economic method for simultaneous determination of metal cations that can form stable chelates with Phen.  相似文献   

12.
We describe an analytical method involving solid-phase extraction (SPE) and capillary zone electrophoresis-electrospray ionization-mass spectrometry (CZE-ESI-MS) for determining some pharmaceutical compounds - naproxen, clofibric acid and bezafibrate - in real water samples. The electrospray parameters were optimized to maximize sensitivity. When a mixed aqueous-organic solvent and CZE-ESI-MS were used to analyze these drugs in water samples, the capillary was coated with hexadimethrin bromide (HDB) to permanently reverse the EOF. The method was developed from off-line SPE-CZE-MS and was validated with surface water. The detection limits were 100 ng.L(-1) for all analytes. The method was applied to analyze water samples from the influent and effluent of a sewage treatment plant. A liquid-liquid extraction step was required before SPE, and the compounds studied were found, some of them between detection and quantification limits.  相似文献   

13.
In this paper, capillary zone electrophoresis with amperometric detection (CZE-AD) was first applied to the simultaneous separation and determination of amitrole and urazole in water samples. A simple end-column electrochemical detector was used in combination with a commercially available capillary electrophoresis instrument with UV detection. The effects of several important factors were investigated to find optimum conditions. A carbon disk electrode was used as working electrode. Separation and determination of these compounds in water samples were performed in 0.030 mol l(-1) acetate buffers at pH 4.5, 25 kV as separation voltage and the samples were introduced by hydrodynamic mode for 1.5 s. Most of the studies realized showed that the direct electrochemical detection is more sensitive and selective than UV detection. Under the optimum conditions, excellent linearity was observed between peak amperometric signal and analyte concentrations in the range of 0.19-1.35 mg l(-1) for amitrole and 0.20-1.62 mg l(-1) for urazole. The detection limits were 63 and 68 microg l(-1) for amitrole and urazole, respectively. The utility of this method was demonstrated by monitoring water samples, and the assay results were satisfactory. The detection limits using a previous preconcentration step for amitrole and urazole in spiked mineral water samples were 0.6 and 1.0 microg l(-1) for amitrole and urazole, respectively.  相似文献   

14.
Fung YS  Lau KM 《Electrophoresis》2001,22(11):2251-2259
A new capillary electrophoresis (CE) procedure was developed for simultaneous determination of ten oxoanions (CrO4(2-), SeO4(2-), MoO4(2-), WO4(2-), VO4(3-), SeO3(2-), As04(3-), TeO3(2-), TeO4(2-), and AsO3(3-)) which were baseline-separated from each other and from the interfering UV absorbing anions (NO3- and NO2-) commonly found in environmental water samples. The new background electrolyte system developed contained 5 mM potassium phosphate and 0.007 mM octadecyltrimethylammonium hydroxide, pH 11.2. The optimized working conditions were electrokinetic sampling at -5 kV for 10 s, running voltage at -15 kV with 5 microA current, and detection wavelength at 205 nm. No interference was observed for non-UV-absorbing anions and UV-absorbing anions up to 20 and 10 times higher concentrations respectively. The speed of analysis was fast, with a complete CE run within 6 min. Wide linear ranges (1-2,000 microg/L), good repeatability in migration time (relative standard deviation RSD 0.55-2.8%), satisfactory precision in peak area (RSD 3.8-5.6%) and peak height (RSD 3.9-5.3%) measurement, and detection limits (1-25 microg/L) sufficiently sensitive to detect oxoanions found in environmental water samples were obtained. The reliability of the CE procedure developed had been established by recovery test and parallel method determination using atomic absoprtion spectrophotometry for real river water sample.  相似文献   

15.
The performance of mass spectrometric (MS) detection and UV detection in combination with reversed-phase liquid chromatography without and with the use of coupled column RPLC (LC-LC) has been compared for the trace analysis of phenylurea herbicides in environmental waters. The selected samples of this comparative study originated from an inter-laboratory study. For both detection modes, a 50 mm x 4.6 mm I.D. column and a 100 mm x 4.6 mm I.D. column packed with 3 microm C18 were used as the first (C-1) and second (C-2) column, respectively. Atmospheric pressure chemical ionization mass spectrometry was performed on a magnetic sector instrument. The LC-LC-MS analysis was carried out on-line by means of direct large volume (11.7 ml) injection (LVI). The performance of both on-line (LVI, 4 ml of sample) and off-line LC-LC-UV (244 nm) analysis was investigated. The latter procedure consisted of a solid-phase extraction (SPE) of 250 ml of water sample on a 500 mg C18 cartridge. The comparative study showed that LC-LC-MS is more selective then LC-LC-UV and, in most cases, more sensitive. The LVI-LC-LC-MS approach combines direct quantification and confirmation of most of the analytes down to a level of 0.01 microg/l in water samples in less then 30 min. As regards LC-LC-UV, the off-line method appeared to be a more viable approach in comparison with the on-line procedure. This method allows the screening of phenylurea's in various types of water samples down to a level of at least 0.05 microg/l. On-line analysis with LVI provided marginal sensitivity (limits of detection of about 0.1 microg/l) and selectivity was sometimes less in case of surface water samples. Both the on-line LVI-LC-LC-MS method and the LC-LC-UV method using off-line SPE were validated by analysing a series of real-life reference samples. These samples were part of an inter-laboratory test and contained residues of herbicides ranging from 0.02 to 0.8 microg/l. Beside good correlation between the methods the data agreed very well with the true values of the samples.  相似文献   

16.
A capillary electrophoretic (CE) method with UV detection at 278 nm has been developed for analysis of the immunosuppressant rapamycin (sirolimus) in human blood at low microg.L(-1) levels. Separation has been achieved in an acidic carrier electrolyte containing sodium dodecyl sulfate and 20% v/v methanol. For sample cleanup and preconcentration, both an off-line solid-phase extraction step using a silica-based reversed-phase material and a newly developed on-capillary focusing technique have been employed. The subsequent treatment of rapamycin under alkaline conditions leads to a cleavage of the lacton bond of the molecule, generating a negatively charged carboxylic group which allows electrokinetic injection into the CE instrument. During the injection process, the negatively charged analyte migrates into an acidic carrier electrolyte, so that it becomes neutral due to protonation and is focused at the capillary inlet. Injection times of 300 s at -7.5 kV could be applied without band-broadening. Results for real samples indicated that the method is fully suited for routine applications and may be an attractive alternative to established liquid chromatographic techniques.  相似文献   

17.
A capillary zone electrophoresis (CZE) method with UV-vis detection has been developed for the simultaneous monitoring of the major degradation products of metribuzin, i.e. deaminometribuzin (DA), deaminodiketometribuzin (DADK) and diketometribuzin (DK). The dissociation acid constants have also been estimated by CE and no significant differences have been observed with the values obtained by applying other techniques. Optimum separation has been achieved in less than 9 min in 40 mM sodium tetraborate buffer, pH 9.5 by applying a voltage of 15kV at 25 degrees C and using p-aminobenzoic acid as internal standard. In order to increase sensitivity, large volume sample stacking (LVSS) with polarity switching has been applied as on-line pre-concentration methodology. Detection limits of 10, 10 and 20 ng/mL for DA, DADK and DK, respectively were obtained. The method has been applied to soil samples, after pressurized liquid extraction (PLE). Samples were extracted at high temperature (103 degrees C and 1500 psi) using methanol as extraction solvent and sodium sulphate as drying agent. This PLE procedure was followed by an off-line pre-concentration and sample clean-up procedure by solid-phase extraction (SPE) using a LiChrolut EN sorbent column. These last two procedures were also suitable for the direct treatment of groundwater samples before CE analysis. The combination of both off-line and on-line pre-concentration procedures provided a significant improvement in sensitivity. LVSS provided pre-concentration factors of 4, 36 and 28 for DK, DA and DADK, respectively and with SPE a pre-concentration of 500-fold for the case of water samples and of 2.5-fold in the case of soil samples was obtained. The method is suitable for the monitoring of these residues in environmental samples with high sensitivity, precision and satisfactory recoveries.  相似文献   

18.
This paper proposes and compares two approaches based on off- and in-line solid-phase extraction (SPE), intended to enhance sensitivity in capillary electrophoresis with ultraviolet detection (CE-UV) using as a model the determination of ochratoxin A (OA) in river water samples. In the off-line SPE mode, the reversed-phase sorbent (octadecilsylane, C18) selectively retains the target analyte (OA) and allows large volumes of the sample (70 mL) to be introduced and subsequently eluted in a small volume (0.1 mL) of an appropriate solution. In the in-line SPE mode, a custom-made microcartridge is inserted near the inlet of the capillary, which is filled with the same C18 sorbent. This solid phase selectively retains OA present in a sample volume as low as approximately 640 μL for subsequent elution with ca. 135 nL of an appropriate eluent. The limit of detection (LOD) obtained with the in-line SPE method was 1 ng L-1, which is 3 orders of magnitude lower than that obtained with CE-UV and roughly 1 order lower than that provided by the off-line SPE-CE-UV method.  相似文献   

19.
A new type of diglycidyloxy-calix[4]arene coated fiber made by sol-gel method was initially prepared for capillary electrophoresis (CE) sample pretreatment. By using headspace solid-phase microextraction (SPME) combined with a novel back-extraction facility coupled off-line to capillary zone electrophoresis (CZE), the simultaneous determination of propranolol enantiomers in human urine was achieved. The clean up effect and preconcentration effect were realized for the first time without derivatization during the SPME process in terms of these strong polarity and thermal stable compounds. Ultrasonic back-extraction and field amplified sample injection (FASI) technologies were employed. Extraction and back-extraction parameters were optimized. Preconcentration of the sample by calix[4]arene fiber based SPME and FASI increased the sensitivity, yielding a limit of detection (LOD) of 0.01microg/ml by CZE-diode array detection (DAD). Method repeatability (RSD<6.5%) and fiber reusability (>150 extraction procedures) were observed over a linear range (0.05-10microg/ml) in urine samples. Based on the superior thermal stability, high alkali- and solvent-resistant ability, marvelous repeatability and long lifetime of the novel fiber, this SPME-FASI-CZE procedure could meet the demand of minimum required performance limit (MRPL) set by the World Anti-doping Agency (WADA) for the detection of propranolol in urine samples.  相似文献   

20.
A solid-phase extraction (SPE) procedure on a styrene-divinylbenzene (SDB-1 cartridge) for extraction and cleaning of the triazine herbicides atrazine, simazine, ametryn, and prometryn and atrazine monodealkylated metabolites from urine samples was developed and optimised for final high-performance liquid chromatographic (HPLC-UV diode array detection) and gas chromatographic (GC-electron-capture detection and GC-thermionic-sensitive detection) analyses. Interfering polar matrices were eliminated by rinsing SDB-1 with 1% acetonitrile in water or with pure water. Extraction recoveries were from 78 to 101% with an RSD of about 10% for all studied compounds. The extraction recovery for the didealkylated atrazine metabolite was significantly lower and this compound cannot be determined with these procedures. Sorbent matrix generated interferences, although not detected by the chromatographic system, lowered the response of nitrogen-phosphorus and electron-capture GC detectors for monodealkylated chlorotriazines when compared to standards prepared in n-hexane. HPLC and GC analysis with SPE (SDB-1) preconcentration showed excellent linearity over the concentration range tested, with detection limits in urine of 10 ng ml(-1) for the parent herbicides (HPLC and GC analysis) and 20 ng ml(-1) for monodealkylated chlorotriazines (HPLC analysis).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号