1.
One of the major prerequisites for the certification of various analytes in different Certified Reference Materials (CRMs) is that the analytical methods used are of verified performance and, hence, that no systematic errors have been left undetected. In the case of difficult measurements, research and feasibility studies are often necessary to ensure that the methods are operating under good quality control. The EC Standards Measurements and Testing Programme (SMT, formerly BCR) usually follows a step-by-step approach which consists in series of interlaboratory studies to assess and improve the quality of measurements prior to certification by comparing different analytical techniques. A programme following such stepwise approach has started in 1987 with the aim of improving the quality of butyltin determinations in environmental matrices. The project involved ca. 20 laboratories from different Member States of the European Union. The first interlaboratory study dealt with simple solutions containing mixtures of organotin compounds and a second exercise focused on the analysis of a tributyltin-spiked sediment. These exercises were continued by two certifications on butyltins in sediment, the first of which could not be successfully concluded owing to the high spread of results observed between the results of different techniques. The second certification allowed a CRM certified for its contents of di- and tributyltin (CRM 462) to be produced. This programme on Sn speciation is now focusing on the certification of butyltin and phenyltin compounds in candidate CRMs of mussel and sediment. This paper gives an account of the step-by-step approach followed and presents the results of the two certification exercises carried out so far. The preparation of the mussel candidate CRM is also described.  相似文献   

2.
A marine reference material, IAEA-140, prepared with a macroalgae (Fucus sp.) was recently produced by the International Atomic Energy Agency and certified for trace and major elements and for methylmercury (MeHg). Certification of this material was achieved as an outcome of an international analytical intercomparison study which resulted in 116 independent sets of results reported by participants from 54 countries. The statistical evaluation of the collected data and the criteria used for assignment of the mean and uncertainty values are described. The analysis of data allowed to certify concentration values for 24 elements and MeHg, and to provide information values for another 10 elements. Regarding the elements which could be given certified values, between two and eight different instrumental methods were used to measure metal concentrations, and four independent analytical procedures were used to measure MeHg concentrations. In order to assess the results of the certification procedure, a comparison was made between the certified values obtained from the world-wide intercomparison results and the values obtained from a small subgroup of well-qualified laboratories. The means and 95% confidence intervals for reference values obtained by the two methods are similar for most elements showing that the usual method of certification used by the IAEA, based on large groups of participants, is indeed pertinent.  相似文献   

3.
The results of an interlaboratory comparison, using various measurement methods to carry out biodiesel testing, are presented and the findings are discussed. The interlaboratory comparison was organised within the framework of an EU-funded project called BIOREMA. A general overview of the project and results of an interlaboratory comparison on bioethanol are published as Part 1 and 2 of this series of papers. In the study presented here, reference values, provided by national metrology institutes and expert laboratories, were used for evaluating the results. Consensus values, derived from the results of all participants, were used to assess any bias between the results from the national metrology institutes and testing laboratories. The emphasis in this interlaboratory comparison was not the performance rating of the individual laboratories, but recognising and interpreting differences caused by the measurement methods applied. For most biodiesel parameters, a good agreement of measurement results was found among different methods, and between the consensus and reference values. The study material was a rapeseed oil fatty acid methyl ester, for which it was demonstrated that it is feasible to prepare and characterise reference materials for biodiesel with well-established reference values for many parameters.  相似文献   

4.
A marine reference material, IAEA-140, prepared with a macroalgae (Fucus sp.) was recently produced by the International Atomic Energy Agency and certified for trace and major elements and for methylmercury (MeHg). Certification of this material was achieved as an outcome of an international analytical intercomparison study which resulted in 116 independent sets of results reported by participants from 54 countries. The statistical evaluation of the collected data and the criteria used for assignment of the mean and uncertainty values are described. The analysis of data allowed to certify concentration values for 24 elements and MeHg, and to provide information values for another 10 elements. Regarding the elements which could be given certified values, between two and eight different instrumental methods were used to measure metal concentrations, and four independent analytical procedures were used to measure MeHg concentrations. In order to assess the results of the certification procedure, a comparison was made between the certified values obtained from the world-wide intercomparison results and the values obtained from a small subgroup of well-qualified laboratories. The means and 95% confidence intervals for reference values obtained by the two methods are similar for most elements showing that the usual method of certification used by the IAEA, based on large groups of participants, is indeed pertinent.  相似文献   

5.
In the nuclear field, the accuracy and comparability of analytical results are crucial to insure correct accountancy, good process control and safe operational conditions. All of these require reliable measurements based on reference materials whose certified values must be obtained by robust metrological approaches according to the requirements of ISO guides 34 and 35. The data processing of the characterization step is one of the key steps of a reference material production process. Among several methods, the use of interlaboratory comparison results for reference material certification is very common. The DerSimonian and Laird excess variance approach, described and implemented in this paper, is a simple and efficient method for the data processing of interlaboratory comparison results for reference material certification. By taking into account not only the laboratory uncertainties but also the spread of the individual results into the calculation of the weighted mean, this approach minimizes the risk to get biased certified values in the case where one or several laboratories either underestimate their measurement uncertainties or do not identify all measurement biases. This statistical method has been applied to a new CETAMA plutonium reference material certified by interlaboratory comparison and has been compared to the classical weighted mean approach described in ISO Guide 35. This paper shows the benefits of using an “excess variance” approach for the certification of reference material by interlaboratory comparison.  相似文献   

6.
The members of the committee NMP 264 “Chemical analysis of non-oxidic raw and basic materials” of the German Standards Institute (DIN) have organized two interlaboratory comparisons for multielement determination of trace elements in silicon carbide (SiC) powders via direct solid sampling methods. One of the interlaboratory comparisons was based on the application of inductively coupled plasma optical emission spectrometry with electrothermal vaporization (ETV ICP OES), and the other on the application of optical emission spectrometry with direct current arc (DC arc OES). The interlaboratory comparisons were organized and performed in the framework of the development of two standards related to “the determination of mass fractions of metallic impurities in powders and grain sizes of ceramic raw and basic materials” by both methods. SiC powders were used as typical examples of this category of material. The aim of the interlaboratory comparisons was to determine the repeatability and reproducibility of both analytical methods to be standardized. This was an important contribution to the practical applicability of both draft standards. Eight laboratories participated in the interlaboratory comparison with ETV ICP OES and nine in the interlaboratory comparison with DC arc OES. Ten analytes were investigated by ETV ICP OES and eleven by DC arc OES. Six different SiC powders were used for the calibration. The mass fractions of their relevant trace elements were determined after wet chemical digestion. All participants followed the analytical requirements described in the draft standards. In the calculation process, three of the calibration materials were used successively as analytical samples. This was managed in the following manner: the material that had just been used as the analytical sample was excluded from the calibration, so the five other materials were used to establish the calibration plot. The results from the interlaboratory comparisons were summarized and used to determine the repeatability and the reproducibility (expressed as standard deviations) of both methods. The calculation was carried out according to the related standard. The results are specified and discussed in this paper, as are the optimized analytical conditions determined and used by the authors of this paper. For both methods, the repeatability relative standard deviations were <25%, usually ~10%, and the reproducibility relative standard deviations were <35%, usually ~15%. These results were regarded as satifactory for both methods intended for rapid analysis of materials for which decomposition is difficult and time-consuming. Also described are some results from an interlaboratory comparison used to certify one of the materials that had been previously used for validation in both interlaboratory comparisons. Thirty laboratories (from eight countries) participated in this interlaboratory comparison for certification. As examples, accepted results are shown from laboratories that used ETV ICP OES or DC arc OES and had performed calibrations by using solutions or oxides, respectively. The certified mass fractions of the certified reference materials were also compared with the mass fractions determined in the interlaboratory comparisons performed within the framework of method standardization. Good agreement was found for most of the analytes.  相似文献   

7.
A reference material for the determination of overall migration from a plastic coextrudate into the fatty food simulant olive oil was produced and certified in an interlaboratory study. The analyses were carried out according to the ENV 1186 standard from the European Committee for Standardization (CEN) [ 1, 2, 3] with exposure of the coextrudate to olive oil for 10 days at 40 degrees C. After an initial preliminary interlaboratory study eight laboratories participated in the certification round, and two different methods were used to obtain single sided exposure of the plastic to the oil. The certified value was determined as the mean of laboratory mean values. No outliers were found. A reference value of 8.6 mg/dm2 +/- 1.4 mg/dm2 (+/- half width of the 95% confidence interval) was obtained which is within the range relevant for the regulatory limit (10 mg/ dm2), making this reference material suitable for laboratories measuring according to the EU overall migration limit [4]. The material has been found stable over 45 months.  相似文献   

8.
Matrix-matched environmental certified reference materials (CRMs) are one of the most useful tools to validate analytical methods, assess analytical laboratory performance and to assist in the resolution of data conflicts between laboratories. This paper describes the development of a lake sediment as a CRM for polychorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (DLPCBs). The presence of DLPCBs in the environment is of increased concern and analytical methods are being developed internationally for monitoring DLPCBs in the environment. This paper also reports the results of an international interlaboratory study involving thirty-five laboratories from seventeen countries, conducted to characterize and validate levels of a sediment reference material for PCDDs, PCDFs and DLPCBs.  相似文献   

9.
Matrix–matched environmental certified reference materials (CRMs) are one of the most useful tools to validate analytical methods, assess analytical laboratory performance and to assist in the resolution of data conflicts between laboratories. This paper describes the development of a lake sediment as a CRM for polychorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (DLPCBs). The presence of DLPCBs in the environment is of increased concern and analytical methods are being developed internationally for monitoring DLPCBs in the environment. This paper also reports the results of an international interlaboratory study involving thirty-five laboratories from seventeen countries, conducted to characterize and validate levels of a sediment reference material for PCDDs, PCDFs and DLPCBs.  相似文献   

10.
The determination of extractable trace metal contents in soil using single extraction procedures is currently performed in many laboratories to assess the bioavailable metal fraction (and related phytotoxic effects) and the accessability to the environment (e.g. contamination of ground waters). Owing to the need for validation of the extraction schemes used and of the analytical techniques, the EC Measurements and Testing Programme (formerly BCR) has organized a project for improving the quality of determination of extractable trace metal contents in soil, the first step being an interlaboratory study to adopt common extraction procedures and the second being a certification campaign to certify two soils for their extractable trace element contents following these procedures. This paper gives a brief overview of the project organisation and describes the preparation, homogeneity and stability studies of two soil candidate reference materials (sewage sludge-amended and terra rossa soils).  相似文献   

11.
A reference material for the determination of overall migration from a plastic coextrudate into the fatty food simulant olive oil was produced and certified in an interlaboratory study. The analyses were carried out according to the ENV 1186 standard from the European Committee for Standardization (CEN) [1, 2, 3] with exposure of the coextrudate to olive oil for 10 days at 40?°C. After an initial preliminary interlaboratory study eight laboratories participated in the certification round, and two different methods were used to obtain single sided exposure of the plastic to the oil. The certified value was determined as the mean of laboratory mean values. No outliers were found. A reference value of 8.6 mg/dm2± 1.4 mg/dm2 (± half width of the 95% confidence interval) was obtained which is within the range relevant for the regulatory limit (10 mg/ dm2), making this reference material suitable for laboratories measuring according to the EU overall migration limit [4]. The material has been found stable over 45 months.  相似文献   

12.
A multi-elemental certified reference material (CRM) based on Arctic marine sediment was prepared and labeled GBW 07481. Approximately 4.5?kg of the sediment was collected during the third Chinese Arctic Expedition. The sediment was processed in procedures that included air drying, debris removal, drying, and milling. The final product contained particles that were generally smaller than 74?;m representing 99% of the total mass. The powder was poured into clean 10-mL brown glass vials and a total of 300 vials were obtained. The homogeneity and stability were preliminarily investigated to assess the suitability of the marine sediment as a candidate CRM. The candidate material was demonstrated to be suitable for this purpose; and hence the certification project was accomplished with nine reputable laboratories. More than 10 reliable analytical methods, including inductively coupled plasma-mass spectrometry (ICP-MS), inductively coupled plasma-atomic emission spectrometry (ICP-AES), and x-ray fluorescence (XRF), were used for analyzing the sediment for 68 elements. The results should be useful for assessing the analytical accuracy of major, minor, and trace elements in marine sediments. Therefore, the CRM is expected to play an important role in Arctic geochemical surveys and environmental assessment.  相似文献   

13.
Due to the increased demand for new reference materials certified for total and methylmercury (MeHg) a sample of mussel homogenate (IAEA-142) has been prepared. Thirteen experienced laboratories reported results for total Hg of which 9 laboratories also reported results for MeHg content. Laboratories reporting MeHg results used various isolation techniques (solvent extraction, saponification, acid leaching, ion-exchange separation, and distillation) and detection systems (cold vapour atomic absorption spectrometry (CV AAS), cold vapour atomic fluorescence spectrometry (CV AFS), gas chromatography with electron capture detector (GC/ECD) and HPLC with CV AAS detector). In the case of total Hg, most of the laboratories used acid digestion, only two used alkaline dissolution, followed either by CV AAS or CV AFS. One laboratory used neutron activation analyses with radiochemical separation. The data received were in good agreement. The value for total Hg was certified to be 126 ng/g, with a 95% confidence interval from 119 to 132 ng/g. For MeHg the certified value of 47 ng/g expressed as Hg was assigned, with a 95% confidence interval from 43 to 51 ng/g. Stability testing has shown that both total and MeHg are stable if samples are stored in a dry and dark place at room temperature. The sample is now available as a certified reference material and is, in particular, useful for quality control measurements of Hg and MeHg in mussel samples at low concentration levels.  相似文献   

14.
 In the interlaboratory study programme "ILS Coal Characterisation", eight interlaboratory studies were organised based on the ISO standards for coal analysis. The use of blind samples in each round allows comparability of measurement results between rounds to be assessed. Based on the results, it could be demonstrated that the vast majority of the measurement results of the laboratories were traceable to results obtained in previous rounds of this programme. The hypothesis has been formulated that the combined standard uncertainty obtained from an interlaboratory study is equal to the reproducibility standard deviation. Whether the reproducibility can be used as the basis for the certification depends on whether the interlaboratory study includes all effects to be taken into account for establishing an uncertainty statement. Received: 12 April 1998 · Accepted: 2 July 1998  相似文献   

15.
Due to the increased demand for new reference materials certified for total and methylmercury (MeHg) a sample of mussel homogenate (IAEA-142) has been prepared. Thirteen experienced laboratories reported results for total Hg of which 9 laboratories also reported results for MeHg content. Laboratories reporting MeHg results used various isolation techniques (solvent extraction, saponification, acid leaching, ion-exchange separation, and distillation) and detection systems (cold vapour atomic absorption spectrometry (CV AAS), cold vapour atomic fluorescence spectrometry (CV AFS), gas chromatography with electron capture detector (GC/ECD) and HPLC with CV AAS detector). In the case of total Hg, most of the laboratories used acid digestion, only two used alkaline dissolution, followed either by CV AAS or CV AFS. One laboratory used neutron activation analyses with radiochemical separation. The data received were in good agreement. The value for total Hg was certified to be 126 ng/g, with a 95% confidence interval from 119 to 132 ng/g. For MeHg the certified value of 47 ng/g expressed as Hg was assigned, with a 95% confidence interval from 43 to 51 ng/g. Stability testing has shown that both total and MeHg are stable if samples are stored in a dry and dark place at room temperature. The sample is now available as a certified reference material and is, in particular, useful for quality control measurements of Hg and MeHg in mussel samples at low concentration levels. Received: 24 September 1996 / Revised: 20 November 1996 / Accepted: 8 December 1996  相似文献   

16.
Abstract

The determination of extractable trace metal contents in soil and sediment, using respectively single and sequential extraction procedures, is currently performed in many laboratories to assess the bioavailable metal fraction (and related phyto-toxic effects) and the accessability to the environment (e.g. contamination of ground waters).

Owing to the need for validation of the extraction schemes used and of the analytical techniques, the Community Bureau of Reference (BCR) decided to organize a project for the improvement of the quality of determinations of extractable trace metal contents in soil and sediment. The implementation of this project follows a stepwise approach involving feasibility studies, intercomparisons to detect and remove sources of errors in the application of the analytical methods, and the certification of the extractable compounds. This paper describes the organization of the work completed so far (feasibility studies and first intercomparison) and discusses its further development.  相似文献   

17.
NIST maintains a portfolio of more than 1300 standard reference materials (SRM), more than a third of these relating to measurements in the biological and environmental fields. As part of the continuous renewal and replacement efforts, a set of new marine sediments has been recently developed covering organic and inorganic determinations. This paper describes the steps taken in sample preparation, homogeneity assay, and analytical characterization and certification with specific emphasis on SRM 2702 inorganics in marine sediment. Neutron activation analysis showed the SRM to be highly homogeneous, opening the possibility for use with solid sampling techniques. The certificate provides certified mass fraction values for 25 elements, reference values for eight elements, and information values for 11 elements, covering most of the priority pollutants with small uncertainties of only several percent relative. The values were obtained by combining results from different laboratories and techniques using a Bayesian statistical model. An intercomparison carried out in field laboratories with the material before certification illustrates a high commutability of this SRM.Electronic Supplementary Material Supplementary material is available in the online version of this article at  相似文献   

18.
A collaborative study among 10 laboratories has been undertaken to investigate the interlaboratory reproducibility of retention measurements in a high performance liquid chromatographic (HPLC) system for separating barbiturates. The system involved an ODS-Hypersil column with an eluent of methanol:phosphate buffer (40:60, v/v) at pH 8.5; all laboratories used the same batch of packing material. The conventional methods of recording retention properties (retention times and capacity factors) gave poor interlaboratory reproducibility. Better results were obtained by expressing the retentions relative to a standard barbiturate (quinalbarbitone); relative adjusted retention times proved to be more effective than straightforward relative retention times. Retention indices based on the alkylarylketone scale were not as reproducible as the methods based on a single closely related compound. The best reproducibility was obtained using corrected capacity factors based on the retention of four barbiturates in a standard mixture. The results of the study are discussed with a view to selecting the best methods of recording retention in HPLC when considering the establishment of databases for drug identification.  相似文献   

19.
Two existing interlaboratory schemes are used to certify a sewage sludge reference material. Data from the analysis (As, Cd, Cr, Cu, Pb, Hg, Ni and Zn) of the material using routine procedures, US EPA and Netherlands NEN, plus INAA and IDMS and an interlaboratory comparison in Eastern Europe have been examined. The Dutch results show significantly lower analytical results for As for the graphite furnace technique compared to HG-AAS, probably due to matrix-effects. The differences between the Dutch and USA results for Cr and Ni suggest that the USEPA 3050A digestion method for dissolution of the metals is less aggressive for this material compared to aqua regia destruction. For international comparability of analytical data it is essential to harmonize method dependent dissolution/extraction techniques. The preparation of reference materials which mimic real samples and certification by ILS result in useful materials for quality control.  相似文献   

20.
This is the first publication which describes the development of a reference material (RM) for the determination of 11 trace elements (Cu, Pb, Mn, Ni, Zn, Fe, Cd, Co, V, As and Al) in rainwater at microgram per liter concentrations. An interlaboratory comparison study for the determination of trace elements in rainwater was carried out for material performance studies to establish analyte concentrations with a stated uncertainty. Fifteen reputed laboratories from Asia, Europe and North America participated in the study. These laboratories used their regular in-house methods to analyze the rainwater samples. The aim of this study is to establish concentration levels of trace elements in rainwater based on interlaboratory study results. Details of the production, homogeneity and stability of the reference sample are given in this article. The organization of the study and the quality assurance measures undertaken at the organizer's laboratory are described. The analytical results obtained from individual laboratories and the analytical methods used for the determination of trace elements in rainwater are discussed. Based on the results obtained from the intercomparison study, certified values as well as informative values are assigned to the 11 trace elements in rainwater.  相似文献   