首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到2条相似文献,搜索用时 0 毫秒
1.
Optical phonon modes, confined in CdSxSe1−x nanocrystal (NC) quantum dots (≈2 nm in radius) grown in a glass matrix by the melting‐nucleation method, were studied by resonant Raman scattering (RRS) spectroscopy and theoretical modeling. The formation of nanocrystalline quantum dots (QDs) is evidenced by the observation of absorption peaks and theoretically expected resonance bands in the RRS excitation spectra. This system, a ternary alloy, offers the possibility to investigate the interplay between the effects of phonon localization by disorder and phonon confinement by the NC/matrix interface. Based on the concept of propagating optical phonons, which is accepted for two‐mode pseudo‐binary alloys in their bulk form, we extended the continuous lattice dynamics model, which has successfully been used for nearly spherical NCs of binary materials, to the present case. After determining the alloy composition for NCs (that was evaluated with only 2–3% uncertainty using the bulk longitudinal optical phonon wavenumbers) and the NC size (using atomic force microscopy and optical absorption data), the experimental RRS spectra were described rather well by this theory, including the line shape and polarization dependence of the scattering intensity. Even though the presence of a compressive strain in the NCs (introduced by the matrix) masks the expected downward shift owing to the phonons' spatial quantization, the asymmetric broadening of both Raman peaks is similar to that characteristic of NCs of pure binary materials. Although with some caution, we suggest that both CdSe‐like and CdS‐like optical phonon modes indeed are propagating within the NC size unless the alloy is considerably heterogeneous. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

2.
The performance of a four‐element Si drift detector for energy‐dispersive fluorescence‐yield X‐ray absorption fine‐structure measurements is reported, operating at the National Institute of Standards and Technology beamline X23A2 at the National Synchrotron Light Source. The detector can acquire X‐ray absorption fine‐structure spectra with a throughput exceeding 4 × 105 counts per second per detector element (>1.6 × 106 total counts per second summed over all four channels). At this count rate the resolution at 6 keV is approximately 220 eV, which adequately resolves the Mn Kα and Kβ fluorescence lines. Accurate dead‐time correction is demonstrated, and it has been incorporated into the ATHENA data analysis program. To maintain counting efficiency and high signal to background, it is suggested that the incoming count rate should not exceed ~70% of the maximum throughput.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号