首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 297 毫秒
1.
A method based on gas chromatography–tandem mass spectrometry after derivatization with N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide was developed for the analysis of monohydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) in hair. The method focused on 52 target compounds corresponding to two- to six-ring monohydroxylated metabolites of polycyclic aromatic hydrocarbons (PAHs). The limits of quantification ranged from 0.2 to 50 pg mg?1. The method was then applied to the analysis of hair samples collected from rats exposed to 12 PAHs at 0.01, 0.1, and 1 mg kg?1, by intraperitoneal injection, for 28 days. The results of this study confirm that these metabolites can be incorporated in hair after intraperitoneal administration of the corresponding parent compound. Only 20 of the 52 metabolites were actually detected in hair samples and corresponded to nine parent PAHs. The mean concentrations of OH-PAHs in rat hair samples exposed to PAHs at 1 mg kg?1 ranged from 0.6?±?0.2 pg mg?1 for 8-hydroxybenzo[b]fluoranthene to 6.7?±?1.0 pg mg?1 for 1-hydroxypyrene. The results also demonstrated that hair pigmentation has no influence on the concentration of most OH-PAHs. This animal experiment confirmed the incorporation of PAH metabolites in hair and demonstrated that the method was sufficiently sensitive to detect low levels of exposure to PAHs. These results confirmed the usefulness of hair analysis in the biomonitoring of human exposure to PAHs.
Figure
Analysis of 52 monohydroxylated polyccyclic aromatic hydrocarbons in a supplemented hair sample by GC-EI-MS/MS  相似文献   

2.
Reproducible and quantitative gas chromatography–mass spectrometry (GC-MS)-based metabolomics analysis of complex biological mixtures requires robust and broad-spectrum derivatization. We have evaluated derivatization of complex metabolite mixtures using trimethylsilyl cyanide (TMSCN) and the most commonly used silylation reagent N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA). For the comparative analysis, two metabolite mixtures, a standard complex mixture of 35 metabolites covering a range of amino acids, carbohydrates, small organic acids, phenolic acids, flavonoids and triterpenoids, and a phenolic extract of blueberry fruits were used. Four different derivatization methods, (1) direct silylation using TMSCN, (2) methoximation followed by TMSCN (M-TMSCN), (3) direct silylation using MSTFA, and (4) methoximation followed by MSTFA (M-MSTFA) were compared in terms of method sensitivity, repeatability, and derivatization reaction time. The derivatization methods were observed at 13 different derivatization times, 5 min to 60 h, for both metabolite mixtures. Fully automated sample derivatization and injection enabled excellent repeatability and precise method comparisons. At the optimal silylation times, peak intensities of 34 out of 35 metabolites of the standard mixture were up to five times higher using M-TMSCN compared with M-MSTFA. For direct silylation of the complex standard mixture, the TMSCN method was up to 54 times more sensitive than MSTFA. Similarly, all the metabolites detected from the blueberry extract showed up to 8.8 times higher intensities when derivatized using TMSCN than with MSTFA. Moreover, TMSCN-based silylation showed fewer artifact peaks, robust profiles, and higher reaction speed as compared with MSTFA. A method repeatability test revealed the following robustness of the four methods: TMSCN?>?M-TMSCN?>?M-MSTFA?>?MSTFA.
Figure
Improved GC-MS profiling of Complex Biological Mixtures by TMSCN based Derivatization  相似文献   

3.
Human exposure to 1,3-butadiene (BD) present in automobile exhaust, cigarette smoke, and forest fires is of great concern because of its potent carcinogenicity. The adverse health effects of BD are mediated by its epoxide metabolites such as 3,4-epoxy-1-butene (EB), which covalently modify genomic DNA to form promutagenic nucleobase adducts. Because of their direct role in cancer, BD-DNA adducts can be used as mechanism-based biomarkers of BD exposure. In the present work, a mass spectrometry-based methodology was developed for accurate, sensitive, and precise quantification of EB-induced N-7-(1-hydroxy-3-buten-2-yl) guanine (EB-GII) DNA adducts in vivo. In our approach, EB-GII adducts are selectively released from DNA backbone by neutral thermal hydrolysis, followed by ultrafiltration, offline HPLC purification, and isotope dilution nanoLC/ESI+-HRMS3 analysis on an Orbitrap Velos mass spectrometer. Following method validation, EB-GII lesions were quantified in human fibrosarcoma (HT1080) cells treated with micromolar concentrations of EB and in liver tissues of rats exposed to sub-ppm concentrations of BD (0.5–1.5 ppm). EB-GII concentrations increased linearly from 1.15?±?0.23 to 10.11?±?0.45 adducts per 106 nucleotides in HT1080 cells treated with 0.5–10 μM DEB. EB-GII concentrations in DNA of laboratory rats exposed to 0.5, 1.0, and 1.5 ppm BD were 0.17?±?0.05, 0.33?±?0.08, and 0.50?±?0.04 adducts per 106 nucleotides, respectively. We also used the new method to determine the in vivo half-life of EB-GII adducts in rat liver DNA (2.20?±?0.12 d) and to detect EB-GII in human blood DNA. To our knowledge, this is the first application of nanoLC/ESI+-HRMS3 Orbitrap methodology to quantitative analysis of DNA adducts in vivo.
Figure a
?  相似文献   

4.
We describe a new use of switchable-polarity solvents for the simultaneous derivatization and extraction of triacylglycerols from vegetable oils before gas-chromatographic analysis. Different equimolecular mixtures of the commercially available amidine 1,8-diazabicyclo[5.4.0]undec-7-ene and n-alkyl alcohols were tested. Triolein was used as a model compound. Very good results were achieved by using butanol (recovery of butyl oleate was 89?±?4 %). The procedure was applied for the characterization of the fatty acid profile of different vegetable oils. No statistically significant differences from the results obtained with the application of two traditional methods were evidenced. Moreover, the use of switchable-polarity solvents showed many advantages: owing to the basicity of the amidines, no catalyst was required; the transterification reaction was conducted under mild conditions, one step and in situ; no particular matrix interferences were evidenced; the solvent was recovered.
Figure
Switchable polarity solvents perform the simultaneous extraction and transesterification of triacylglycerols from vegetable oils. The method represent a new in situ derivatization procedure for the gas chromatographic characterization of thir fatty acid profiles.  相似文献   

5.
We report on newly synthesized Ag(I)-filled multiwall carbon nanotubes as a potential sensing element in ion-selective carbon paste electrodes for the determination of free cyanide in aqueous solution. The electrode was obtained by entrapping the silver-filled nanotubes into a carbon paste and displays a Nernstian response with a slope of 59.8?±?0.3?mV decade?1, a very wide linear range (from 21.0?nM to 0.1?M of cyanide), a lower detection limit of 13.0?nM, and a response time of <2?min. The operational lifetime is up to 3?months without significant deviation in normal function.
Figure
Silver(I)-filled Multiwall Carbon Nanotube as Sensing Element in Cyanide-selective Carbon Paste Electrode  相似文献   

6.
We are presenting the first method for identification and quantification of antibiotic derivatives in honey samples using regenerable antigen microarrays in combination with an automated flow injection system. The scheme is based on an indirect competitive immunoassay format using monoclonal antibodies bound to the surface of the microarray. The surface of glass slides was coated with epoxy-activated poly(ethylene glycol) and enables direct immobilization of the antibiotic derivatives. The antigen/antibody interaction on the surface of the chip can be detected by chemiluminescence (CL) read-out via CCD camera. The method allows for fast analysis of the four analytes simultaneously and without purification or extraction. An effective data evaluation method also was developed to warrant unambiguous identification of the spots and to establish grey levels of CL intensities. The software developed enables fast and automated processing of the CL images. Dose?Cresponse curves were obtained for the derivatives of enrofloxacin, sulfadiazine, sulfamethazine and streptomycin. Spiking experiments revealed adequate recoveries within the dynamic ranges of the calibration curves of enrofloxacin (92%?±?6%), sulfamethazine (130%?±?21%), sulfadiazine (89%?±?20%) and streptomycin (93%?±?4%).
Figure
Flow-scheme of the chemiluminescence multianalyte chip immunoassay for the determination of antibiotic residues in honey  相似文献   

7.
The thickness and refractive index of 1,2-dipalmitoyl-sn-glycero-3-phosphatidyl choline (DPPC) and 1,2-dipalmitoyl-sn-glycero-3-phosphoethanolamine (DPPE) monolayers Langmuir--Blodgett (LB) deposited on mica were measured in dry air and bulk water using multiple-beam interferometry (MBI). Measurements of thickness using atomic force microscopy (AFM) of identical monolayers, and X-ray reflectivity (XRR) of the monolayers on quartz were taken for comparison. The measurement of the properties of solid-supported monolayers in dry air allows lipid optical properties to be determined free from solvent effects. The thickness and refractive index measured by MBI were 25.5?±?0.6 Å and 1.485?±?0.007 for DPPE monolayers, and 23.9?±?0.5 Å and 1.478?±?0.006 for DPPC monolayers in dry air. These thicknesses are consistent with the other techniques used in this work as well as other measurements in the literature. The refractive indices of solid-supported lipid monolayers have not been previously measured. The values are higher than previous measurements on black lipid films done by reflectometry, which is attributed to increased lipid packing density and the absence of hydrocarbon solvents. Applying water to the monolayers had no measurable effect on their properties, indicating that any change in hydration was below detection.
Figure
?  相似文献   

8.
We report on a graphite electrode onto which polypyrrole was electrodeposited and then doped with chromate ion. This electrode can serve as a Cr(VI)-selective solid-state electrode. Electropolymerization of pyrrole was performed potentiostatically at 0.80?V (vs. SCE) using battery graphite as the working electrode in a solution containing 0.10?M of pyrrole and 20?mM of chromate. A platinum wire was used as an auxiliary electrode. The new electrode displays high selectivity, a very wide dynamic range, a sufficiently fast response time and a good shelf lifetime. It shows a linear Nernstian response over 1.0?×?10?6 to 1.0?×?10?1?M concentration range (with a slope of 26.55?±?0.20?mV per log of concentration). The detection limit is 0.5?μM, and the pH optimum is 7.0.
Figure
A highly selective solid state Cr(VI) ion-selective electrode based on polypyrrole conducting polymer was prepared. The introduced Cr(VI) micro sensor electrode exhibited linear response over a wide working concentration range with a high regression coefficient and a near Nernstian slope. The SEM image of PPy/CrO4 thin film shows unevenly distributed nanoparticles.  相似文献   

9.
We describe a silver(I)-selective carbon paste electrode modified with multi-walled carbon nanotubes and a silver-chelating Schiff base, and its electrochemical response to Ag(I). Effects of reduction potential and time, accumulation time, pH of the solution and the stripping medium were studied by differential pulse anodic stripping voltammetry and optimized. The findings resulted in a method for the determination of silver over a linear response range (from 0.5 to 235 ng?mL?1) and with a detection limit as low as 0.08 ng?mL?1. The sensor displays good repeatability (with the RSD of ±?2.75 % for 7 replicates) and was applied to the determination of Ag(I) in water samples and X-ray photographic films.
Figure
Open circuit accumulation of Ag(I) onto a surface of EHPO-MCPE and determination by Differential pulse anodic stripping voltammetry  相似文献   

10.
A composite was prepared from copper and graphene oxide (Cu-GO) by in-situ chemical reduction of a mixture containing GO and Cu(II) ions with potassium borohydride. The morphology and structure of the composite were confirmed by various physicochemical techniques. The materials were used in a tyrosinase-based microbiosensor where the enzyme is immobilized in a biocompatible matrix consisting of poly(ortho-phenylene diamine) and Cu-GO. The composite was deposited on the surface of an 8-μm thick carbon fiber microelectrode. The role of each component in the sensing layer was systematically investigated with respect to the analytical performance of the system. In its optimal configuration, the biosensor demonstrated (a) a sensitivity of 6.1?±?3 nA mM-1 dopamine (DA), (b) a linear response to DA (with a Michaelis-Menten constant of 0.29?±?0.03 mM), (c) good selectivity over ascorbic acid and uric acid, and (d) a high blocking capacity (112.2?±?2 mM) for ascorbic acid.
Figure
Poly(o-phenylenediamine) electropolymerized carbon fiber electrode with sensitivity towards dopamine (DA) is 6.1?±?3 nA mM?1 supported by Cu-GO. The linear range for DA is 0.29?±?0.03 mM with 0.033 μM LOD and fast response time of <8 s with ascorbic acid blocking capacity of 112.2?±?2 mM AA. Studies on different ratio of Glu/Tyr revealed that 10:3 gave best overall response.  相似文献   

11.
To establish planar biomimetic membranes across large scale partition aperture arrays, we created a disposable single-use horizontal chamber design that supports combined optical–electrical measurements. Functional lipid bilayers could easily and efficiently be established across CO2 laser micro-structured 8?×?8 aperture partition arrays with average aperture diameters of 301?±?5 μm. We addressed the electro-physical properties of the lipid bilayers established across the micro-structured scaffold arrays by controllable reconstitution of biotechnological and physiological relevant membrane peptides and proteins. Next, we tested the scalability of the biomimetic membrane design by establishing lipid bilayers in rectangular 24?×?24 and hexagonal 24?×?27 aperture arrays, respectively. The results presented show that the design is suitable for further developments of sensitive biosensor assays, and furthermore demonstrate that the design can conveniently be scaled up to support planar lipid bilayers in large square-centimeter partition arrays.
Figure
Fluorescent image of a large 24?×?24 rectangular bilayer array  相似文献   

12.
A monodisperse molecularly imprinted polymer (MIP) for curcumin was first prepared by precipitation polymerization using methacrylamide (MAM) and 4-vinylpyridine as functional co-monomers, divinylbenzene as a crosslinker, and a mixture of acetonitrile and toluene as a porogen. The use of MAM as the co-monomer resulted in the formation of a monodisperse MIP and non-imprinted polymer (NIP). MIP and NIP, respectively, were monodispersed with a narrow particle size distribution (3.3?±?0.09 and 3.5?±?0.10 μm). In addition to shape recognition, hydrophobic and hydrogen-bonding interactions affected the retention and molecular-recognition of curcumin on the MIP. The MIP for curcumin could extract curcuminoids (curcumin, demethoxycurcumin, and bisdemethoxycurcumin) in Curcuma longa L.
Figure
MIPs prepared with 4-VPY (left hand) and 4-VPY and MAM (right hand) as the functional monomers were polydispersed and monodispersed, respectively  相似文献   

13.
We have developed two methods for the quantitation of gabapentin in human plasma. They are based on capillary electrophoresis with laser-induced fluorescence detection (CE-LIF) with and without solid-phase extraction (SPE) and the derivatizing reagent 5-(4,6-dichlorotriazinyl)amino fluoresencin. The conditions for derivatization, separation and extraction were investigated in detail, and the optimal labeling conditions include a temperature of 40?°C, a reaction time of 30?min, and the use of a borate buffer of pH 9.0 as the reaction medium. A borate buffer of pH 9.2 served as a background electrolyte for CE separations. The CE-LIF and SPE-CE-LIF methods have linear ranges of 5–200?nmol?L?1 and 0.2–10?nmol?L?1, respectively, and the limits of detection are 0.5 and 0.02?nmol?L?1, respectively. The SPE-CE-LIF method was successfully applied to the determination of gabapentin in blood plasma samples.
Figure
Two methods have been developed for the quantization of gabapentin (GBP) in human plasma. They are based on capillary electrophoresis-laser induced fluorescence detection (CE-LIF) with and without solid-phase extraction (SPE) and the derivatizing reagent 5-(4,6-dichlorotriazinyl)aminofluorescein.  相似文献   

14.
A non-denaturating isoelectric focusing (ND-IEF) gel electrophoresis protocol has been developed to study and identify uranium (U)–protein complexes with laser ablation–inductively coupled plasma mass spectrometry (LA-ICP MS) and electrospray ionization mass spectrometry (ESI-MS). The ND-IEF-LA-ICP MS methodology set-up was initiated using in vitro U–protein complex standards (i.e., U–bovine serum albumin and U–transferrin) allowing the assessment of U recovery to 64.4?±?0.4 %. This methodology enabled the quantification of U–protein complexes at 9.03?±?0.23, 15.27?±?0.36, and 177.31?±?25.51 nmol U L?1 in digestive gland cytosols of the crayfish, Procambarus clarkii, exposed respectively to 0, 0.12, and 2.5 μmol of waterborne depleted U L?1 during 10 days. ND-IEF-LA-ICP MS limit of detection was 19.3 pmol U L?1. Elemental ICP MS signals obtained both in ND-IEF electropherograms and in size exclusion chromatograms of in vivo U–protein complexes revealed interactions between U- and Fe- and Cu-proteins. Moreover, three proteins (hemocyanin, pseudohemocyanin-2, and arginine kinase) out of 42 were identified as potential uranium targets in waterborne-exposed crayfish cytosols by microbore reversed phase chromatography coupled to molecular mass spectrometry (µRPC-ESI-MS/MS) after ND-IEF separation.
Figure
The paper presents the development of a non-denaturating protocol for the separation of uranium-protein complexes by isoelectric focusing gel electrophoresis (ND-IEF) before their quantitative detection by Laser Ablation coupled to Inductively Coupled Plasma Mass Spectrometry. Potential protein targets of uranium are subsequently identified by liquid chromatography - electrospray mass spectrometry  相似文献   

15.
A label-free nanoparticle array platform has been used to detect total peanut allergen-specific binding from whole serum of patients suffering from peanut allergy. The serum from 10 patients was screened against a four-allergen panel of cat and dog dander, dust mite and peanut allergen protein Ara h1. The IgE and IgG contributions to the total specific-binding protein load to Ara h1 were identified using two secondary IgG- and IgE-specific antibodies and were found to contribute less than 50?% of the total specific protein load. The total mass of IgE, IgE and the unresolved specific-binding protein ΔsBP for Ara h1 provides a new serum profile for high-RAST-grade patients 5 and 6 with the IgG/IgE ratio of 4?±?2 and ΔsBP/IgE ratio of 17?±?11, neither of which is protective for the small patient cohort.
Figure
Binding of the specefic IgE/IgG and unresolved material X to the sensor surface functionalized with allergen  相似文献   

16.
A comprehensive method for the analysis of 11 target pharmaceuticals representing multiple commonly used therapeutic classes was developed for biological tissues (fish), reclaimed water, and the surface water directly affected by irrigation with reclaimed water. One gram of fish tissue homogenate was extracted by accelerated solvent extraction with methylene chloride followed by mixed-mode cation exchange solid phase extraction (SPE) cleanup and analyzed by liquid chromatography-tandem mass spectrometry. Compared to previously reported methods, the protocol produces cleaner extracts resulting in lower method detection limits. Similarly, an SPE method based on Oasis HLB cartridges was used to concentrate and cleanup reclaimed and surface water samples. Among the 11 target compounds analyzed, trimethoprim, caffeine, sulfamethoxazole, diphenhydramine, diltiazem, carbamazepine, erythromycin, and fluoxetine were consistently detected in reclaimed water. Caffeine, diphenhydramine, and carbamazepine were consistently detected in fish and surface water samples. Bioaccumulation factors for caffeine, diphenhydramine, and carbamazepine in mosquito fish (Gambusia holbrooki) were calculated at 29?±?26, 821?±?422, and 108?±?144, respectively. This is the first report of potential accumulation of caffeine in fish from a water body directly influenced by reclaimed water.
Figure
The pharmaceuticals detected in reclaimed water and the fresh water directly affected by reclaimed water.  相似文献   

17.
The carboxyl groups of tryptic peptides were derivatized with a tertiary or quaternary amine labeling reagent to generate more highly charged peptide ions that fragment efficiently by electron transfer dissociation (ETD). All peptide carboxyl groups—aspartic and glutamic acid side-chains as well as C-termini—were derivatized with an average reaction efficiency of 99 %. This nearly complete labeling avoids making complex peptide mixtures even more complex because of partially-labeled products, and it allows the use of static modifications during database searching. Alkyl tertiary amines were found to be the optimal labeling reagent among the four types tested. Charge states are substantially higher for derivatized peptides: a modified tryptic digest of bovine serum albumin (BSA) generates ~90% of its precursor ions with z? > ?2, compared with less than 40 % for the unmodified sample. The increased charge density of modified peptide ions yields highly efficient ETD fragmentation, leading to many additional peptide identifications and higher sequence coverage (e.g., 70 % for modified versus only 43 % for unmodified BSA). The utility of this labeling strategy was demonstrated on a tryptic digest of ribosomal proteins isolated from yeast cells. Peptide derivatization of this sample produced an increase in the number of identified proteins, a >50 % increase in the sequence coverage of these proteins, and a doubling of the number of peptide spectral matches. This carboxyl derivatization strategy greatly improves proteome coverage obtained from ETD-MS/MS of tryptic digests, and we anticipate that it will also enhance identification and localization of post-translational modifications.
Figure
?  相似文献   

18.
We have synthesized cadmium(II) ion-imprinted polymers (IIP) and non-imprinted polymers (NIP) using 1-(2-pyridylazo)-2-naphthol as a ligand. The materials were used to prepare a carbon paste electrode for the determination of Cd(II). Polymerization was performed with (a) methacrylic acid as a functional monomer, (b) ethyleneglycol dimethacrylate as the crosslinking monomer, and (c) 2,2′-azobis(isobutyronitrile) as the initiator. Imprinted cadmium ion was removed from the polymeric matrix using nitric acid. The measurements were carried out in an closed circuit after accumulation at ?1.2?V, this followed by electrolysis of the accumulated Cd(II) by voltammetric scanning from ?1.0 to ?0.6?V. The parameters governing the response of the electrode were studied. Under optimized conditions, the response of the electrode is linear in the range from 2.0 to 200?ng?mL?1. The detection limit is 0.31?ng?mL?1. The relative standard deviations are ±3.4 and ±2.1?% for 7 successive determinations of 20.0 and 50.0?ng?mL-1 of Cd(II), respectively. The method was applied to the determination of cadmium (II) in water and food samples.
Figure
a) Preparation of modified carbon paste b) Preparation of Cd(II)-IIP-MCPE c) Differential pulse anodic stripping voltammetry d) Voltammogram  相似文献   

19.
Glycated hemoglobin (HbA1c) has been recently adopted as a diagnostic marker of type 2 diabetes. However, its usage is currently limited to fresh blood samples. To allow retrospective HbA1c measurement in blood banks developed in large epidemic studies, here, we contribute to validate HbA1c assessment in frozen versus fresh blood samples from a cohort of diabetic/nondiabetic adult subjects. HbA1c was measured by HPLC in 237 fresh whole blood samples and on the same samples after a 12-month storage and a further 6-month-refrozen storage. Mean HbA1c?±?SD in fresh, frozen, and refrozen samples was 6.9?±?1.2, 6.6?±?1.1, and 6.4?±?1.0 % for the Diabetes Control and Complications Trial and 52?±?13, 49?±?12, and 46?±?11 mmol/mol for the International Federation of Clinical Chemistry and Laboratory Medicine reference, respectively. A significant correlation was found between fresh/frozen and fresh/refrozen (R?=?0.994 and 0.993, P?<?0.001) samples. HbA1c relative error ratio (%RER) between frozen/refrozen and fresh samples significantly correlated with HbA1c and depended on fresh value range, increasing in the five HbA1c classes (<6.0, 6.0–6.5, 6.5–7, 7–8, ≥8 %, corresponding to <42, 42–48, 48–53, 53–64, ≥64 mmol/mol, P?<?0.001). In particular, the 6.5 % (48 mmol/mol) HbA1c diagnostic cutoff of fresh samples identified two classes reflecting significant differences in %RER (2.8?±?2.0 and 3.3?±?1.7; P?<?0.05) between frozen and fresh samples. In conclusion, our results demonstrate a high correlation between data from fresh and frozen samples, with a very limited %RER between the two measurements, which increases with baseline HbA1c levels. Accordingly, when analyzing biobank frozen specimens for diagnostic purpose, the effect of the HbA1c range should be taken into account.
Figure
HbA1c separation profile obtained by HPLC from a whole blood sample  相似文献   

20.
Human mammaglobin (MG) has been found to be the most specific molecular marker for the hematogenous spread of breast cancer cells. In our study, an electrochemical impedance spectroscopic DNA biosensor was established for the detection of MG in breast cancer patients. The working conditions for the biosensor, such as immobilization time, rinse process, and hybridization process, were optimized. Under the optimal conditions, the charge transfer resistance of the proposed DNA biosensor shows excellent correlation with the amount of the complementary oligonucleotides in the range from 1.0?×?10?9 to 2.0?×?10?8?M. The detection limit is 5.0?×?10?10?M. The proposed biosensor was used to detect the polymerase chain reaction amplification products of actual clinical breast cancer samples. The results were compared with that obtained by conventional gel electrophoresis. The results indicate that the electrochemical impedance spectroscopic assay is significantly sensitive and time-saving. The simple strategy described here is expected to be used in clinical application for early diagnosis of breast cancer.
Figure
The specificity of the electrochemical biosensor for the PCR products investigated by comparing the detection results of positive sample and negative control.  相似文献   