首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Circulating tumor cells (CTCs) present in the bloodstream are strongly linked to the invasive behavior of cancer; therefore, their detection holds great significance for monitoring disease progression. Currently available CTC isolation tools are often based on tumor-specific antigen or cell size approaches. However, these techniques are limited due to the lack of a unique and universal marker for CTCs, and the overlapping size between CTCs and regular blood cells. Dielectrophoresis (DEP), governed by the intrinsic dielectric properties of the particles, is a promising marker-free, accurate, fast, and low-cost technique that enables the isolation of CTCs from blood cells. This study presents a continuous flow, antibody-free DEP-based microfluidic device to concentrate MCF7 breast cancer cells, a well-established CTC model, in the presence of leukocytes extracted from human blood samples. The enrichment strategy was determined according to the DEP responses of the corresponding cells, obtained in our previously reported DEP spectrum study. It was based on the positive-DEP integrated with hydrodynamic focusing under continuous flow. In the proposed device, the parylene microchannel with two inlets and outlets was built on top of rectangular and equally spaced isolated planar electrodes rotated certain degree relative to the main flow (13°). The recovery of MCF7 cells mixed with leukocytes was 74%–98% at a frequency of 1 MHz and a magnitude of 10–12 Vpp. Overall, the results revealed that the presented system successfully concentrates MCF7 cancer cells from leukocytes, ultimately verifying our DEP spectrum study, in which the enrichment frequency and separation strategy of the microfluidic system were determined.  相似文献   

2.
In this paper, a method for continuous flow separation of circulating malignant cells from blood in a microfluidic device using dielectrophoresis is discussed. Separation of MDA231 breast cancer cells after mixing with normal blood cells was achieved with a level of accuracy that enabled precise counting of the malignant cells, separation and eventually, sub-culturing. MDA231 cells were separated from the blood to a daughter channel using two pairs of interdigitated activated comb-like electrode structures. All experiments are performed with conductivity adjusted medium samples. The electrode pairs were positioned divergent and convergent with respect to the flow. The AC signals used in the separation are 20 V peak-to-peak with frequencies of 10-50 kHz. The separation is based on balance of magnitude of the dielectrophoretic force and hydrodynamic force. The difference in response between circulating malignant cells and normal cells at a certain band of alternating current frequencies was used for rapid separation of cancer cells from blood. The significance of these experimental results is discussed in this paper, with detailed reporting on the suspension medium, preparation of cells, flow condition and the fabrication process of the microfluidic chip. The present technique could potentially be applied to identify incident cancer at a stage and size that is not yet detectable by standard diagnostic techniques (imaging and biochemical testing). Alternatively, it may also be used to detect cancer recurrences.  相似文献   

3.
We describe the design, microfabrication, and testing of a microfluidic device for the separation of cancer cells based on dielectrophoresis. Cancer cells, specifically green fluorescent protein‐labeled MDA‐MB‐231, are successfully separated from a heterogeneous mixture of the same and normal blood cells. MDA‐MB‐231 cancer cells are separated with an accuracy that enables precise detection and counting of circulating tumor cells present among normal blood cells. The separation is performed using a set of planar interdigitated transducer electrodes that are deposited on the surface of a glass wafer and slightly protrude into the separation microchannel at one side. The device includes two parts, namely, a glass wafer and polydimethylsiloxane element. The device is fabricated using standard microfabrication techniques. All experiments are conducted with low conductivity sucrose‐dextrose isotonic medium. The variation in response between MDA‐MB‐231 cancer cells and normal cells to a certain band of alternating‐current frequencies is used for continuous separation of cells. The fabrication of the microfluidic device, preparation of cells and medium, and flow conditions are detailed. The proposed microdevice can be used to detect and separate malignant cells from heterogeneous mixture of cells for the purpose of early screening for cancer.  相似文献   

4.
5.
The separation and manipulation of microparticles in lab on a chip devices have importance in point of care diagnostic tools and analytical applications. The separation and sorting of particles from biological and clinical samples can be performed using active and passive techniques. In passive techniques, no external force is applied while in active techniques by applying external force (e.g. electrical), higher separation efficiency is obtained. In this article, passive (pinched flow fractionation) and active (insulator‐based dielectrophoresis) methods were combined to increase the separation efficiency at lower voltages. First by simulation, appropriate values of geometry and applied voltages for better focusing, separation, and lower Joule heating were obtained. Separation of 1.5 and 6 μm polystyrene microparticles was experimentally obtained at optimized geometry and low total applied voltage (25 V). Also, the trajectory of 1.5 μm microparticles was controlled by adjusting the total applied voltage.  相似文献   

6.
Detection and analysis of circulating tumor cells (CTCs) have emerged as a promising way to diagnose cancer, study its cellular mechanism, and test or develop potential treatments. However, the rarity of CTCs among peripheral blood cells is a big challenge toward CTC detection. In addition, in cases where there is similar size range between certain types of CTCs (e.g. breast cancer cells) and white blood cells (WBCs), high‐resolution techniques are needed. In the present work, we propose a deterministic dielectrophoresis (DEP) method that combines the concept of deterministic lateral displacement (DLD) and insulator‐based dielectrophoresis (iDEP) techniques that rely on physical markers such as size and dielectric properties to differentiate different type of cells. The proposed deterministic DEP technology takes advantage of frequency‐controlled AC electric field for continuous separation of CTCs from peripheral blood cells. Utilizing numerical modeling, different aspects of coupled DLD‐DEP design such as the required applied voltages, velocities, and geometrical parameters of DLD arrays of microposts are investigated. Regarding the inevitable difference and uncertainty ranges for the reported crossover frequencies of cells, a comprehensive analysis is conducted on applied electric field frequency as design's determinant factor. Deterministic DEP design provides continuous sorting of CTCs from WBCs even with similar size and has the future potential for high throughput and efficiency.  相似文献   

7.
The trapping or immobilization of individual cells at specific locations in microfluidic platforms is essential for single cell studies, especially those requiring cell stimulation and downstream analysis of cellular content. Selectivity for individual cell types is required when mixtures of cells are analyzed in heterogeneous and complex matrices, such as the selection of metastatic cells within blood samples. Here, we demonstrate a microfluidic device based on direct current (DC) insulator-based dielectrophoresis (iDEP) for selective trapping of single MCF-7 breast cancer cells from mixtures with both mammalian peripheral blood mononuclear cells (PBMC) as well MDA-MB-231 as a second breast cancer cell type. The microfluidic device has a teardrop iDEP design optimized for the selective capture of single cells based on their differential DEP behavior under DC conditions. Numerical simulations adapted to experimental device geometries and buffer conditions predicted the trapping condition in which the dielectrophoretic force overcomes electrokinetic forces for MCF-7 cells, whereas PBMCs were not trapped. Experimentally, selective trapping of viable MCF-7 cells in mixtures with PBMCs was demonstrated in good agreement with simulations. A similar approach was also executed to demonstrate the selective trapping of MCF-7 cells in a mixture with MDA-MB-231 cells, indicating the selectivity of the device for weakly invasive and highly invasive breast cancer cells. The DEP studies were complemented with cell viability tests indicating acceptable cell viability over the course of an iDEP trapping experiment.
Figure
?  相似文献   

8.
In this study, a dielectrophoresis field‐flow fractionation device was analyzed using a numerical simulation method and the behaviors of a set of different cells were investigated. By reducing the alternating current frequency of the electrodes from the value used in the original setup configuration and increasing the number of exit channels, total discrimination in cell trajectories and subsequent separation of four cell types were achieved. Cells were differentiated based on their size and dielectric response that are represented in their real part of Clausius–Mossotti factor at different frequencies. A number of novel designs were also proposed based on the original setup configuration. It was seen that by reducing the length of the main channel and the number of electrodes at low frequencies and not changing the inlet flow velocities, cell separation was still achieved successfully, although with a slightly larger electrode voltage. The shorter main channel decreased the residence time for the cells on the chip and also reduced the overall size of the device—these were improvements over the original design. The obtained results can be used to analyze other cell types by knowing their size and dielectric properties to design geometries that can ensure separation.  相似文献   

9.
This work is the first to demonstrate the ability of contactless dielectrophoresis (cDEP) to isolate target cell species from a heterogeneous sample of live cells. Since all cell types have a unique molecular composition, it is expected that their dielectrophoretic (DEP) properties are also unique. cDEP is a technique developed to improve upon traditional and insulator-based DEP devices by replacing embedded metal electrodes with fluid electrode channels positioned alongside desired trapping locations. Through the placement of the fluid electrode channels and the removal of contact between the electrodes and the sample fluid, cDEP mitigates issues associated with sample/electrode contact. MCF10A, MCF7, and MDA-MB-231 human breast cells were used to represent early, intermediate, and late-staged breast cancer, respectively. Trapping frequency responses of each cell type were distinct, with the largest difference between the cells found at 20 and 30 V. MDA-MB-231 cells were successfully isolated from a population containing MCF10A and MCF7 cells at 30 V and 164 kHz. The ability to selectively concentrate cells is the key to development of biological applications using DEP. The isolation of these cells could provide a workbench for clinicians to detect transformed cells at their earliest stage, screen drug therapies prior to patient treatment, increasing the probability of success, and eliminate unsuccessful treatment options.  相似文献   

10.
Sim TS  Kwon K  Park JC  Lee JG  Jung HI 《Lab on a chip》2011,11(1):93-99
Previously we introduced a novel hydrodynamic method using a multi-orifice microchannel for size-based particle separation, which is called a multi-orifice flow fractionation (MOFF). The MOFF has several advantages such as continuous, non-intrusive, and minimal power consumption. However, it has a limitation that the recovery yield is relatively low. Although the recovery may be increased by adjusting parameters such as the Reynolds number and central collecting region, poor purity inevitably followed. We newly designed and fabricated a microfluidic channel for multi-stage multi-orifice flow fractionation (MS-MOFF), which is made by combining three multi-orifice segments, and consists of 3 inlets, 3 filters, 3 multi-orifice segments and 5 outlets. The structure and dimensions of the MS-MOFF were determined by the hydrodynamic principles to have constant Reynolds numbers at each multi-orifice segment. Polystyrene microspheres of two different sizes (7 μm and 15 μm) were tested. With this device, we made an attempt to improve recovery and minimize loss of purity by collecting and re-separating non-selected particles of the first separation. The final recovery successfully increased from 73.2% to 88.7% while the final purity slightly decreased from 91.4% to 89.1% (for 15 μm). These values were never achievable with the single-stage MOFF (SS-MOFF) having only one multi-orifice segment in our previous work. The MS-MOFF channel will be useful for clinical applications, such as separation of circulating tumor cells (CTC) or rare cells from human blood samples.  相似文献   

11.
In this paper, we successfully separated malignant human breast cancer epithelial cells (MCF 7) from healthy breast cells (MCF 10A) and analyzed the main parameters that influence the separation efficiency with an advanced dielectrophoresis (DEP)-activated cell sorter (DACS). Using the efficient DACS, the malignant cancer cells (MCF 7) were isolated successfully by noninvasive methods from normal cells with similar cell size distributions (MCF 10A), depending on differences between their material properties such as conductivity and permittivity, because our system was able to discern the subtle differences in the properties by generating continuously changed electrical field gradients. In order to evaluate the separation performance without considering size variations, the cells collected from each outlet were divided into size-dependent groups and counted statistically. Following that, the quantitative relative ratio of numbers between MCF 7 and MCF 10A cells in each size-dependent group separated by the DEP were compared according to applied frequencies in the range 48, 51, and 53 MHz with an applied amplitude of 8 Vpp. Finally, under the applied voltage of 48 MHz–8 Vpp and a flow rate of 290 μm/s, MCF 7 and MCF 10A cells were separated with a maximum efficiency of 86.67% and 98.73% respectively. Therefore, our suggested system shows it can be used for detection and separation of cancerous epithelial cells from noncancerous cells in clinical applications.  相似文献   

12.
Gas chromatography/mass spectrometry/isotope ratio mass spectrometry (GC/MS/IRMS) methods for delta(13)C measurement of the halomethanes CH(3)Cl, CH(3)Br, CH(3)I and methanethiol (CH(3)SH) during studies of their biological production, biological degradation, and abiotic reactions are presented. Optimisation of gas chromatographic parameters allowed the identification and quantification of CO(2), O(2), CH(3)Cl, CH(3)Br, CH(3)I and CH(3)SH from a single sample, and also the concurrent measurement of delta(13)C for each of the halomethanes and methanethiol. Precision of delta(13)C measurements for halomethane standards decreased (+/-0.3, +/-0.5 and +/-1.3 per thousand) with increasing mass (CH(3)Cl, CH(3)Br, CH(3)I, respectively). Given that carbon isotope effects during biological production, biological degradation and some chemical (abiotic) reactions can be as much as 100 per thousand, stable isotope analysis offers a precise method to study the global sources and sinks of these halogenated compounds that are of considerable importance to our understanding of stratospheric ozone destruction.  相似文献   

13.
 The extraction behavior of platinum(IV) was studied with N-n-octylaniline as a function of different parameters, such as pH, concentrations of weak acids, mineral acids, reagents and elution time. A selective method was developed for the extraction chromatographic studies of platinum(IV) and its separation from several metal ions with N-n-octylaniline (liquid anion exchanger) as a stationary phase on silica gel. The quantitative extraction of platinum(IV) was observed with 0.067 mol/L N-n-octylaniline and 0.015 mol/L ascorbic acid at pH 1.0. Metal ion was stripped from the column with water and determined spectrophotometrically with stannous chloride method. The proposed method is free from the interference of a large number of cations and anions. Platinum(IV) was separated from pharmaceutical preparations, alloys and synthetic mixtures. Mutual separation scheme was developed for platinum(IV), palladium(II) and gold(III). The log-log plot of N-n-octylaniline concentration versus the distribution ratio indicates that the probable extracted species is [RR′NH+2 ]· Pt(C6H7O6)-3.  相似文献   

14.
Hyaluronic acid (HA) was extracted in a relatively large scale from rooster comb using a method similar to that reported previously. The extraction method was modified to simplify and to reduce time and cost in order to accommodate a large-scale extraction. Five hundred grams of frozen rooster combs yielded about 500?mg of dried HA. Extracted HA was characterized using asymmetrical flow field-flow fractionation (AsFlFFF) coupled online to a multiangle light scattering detector and a refractive index detector to determine the molecular size, molecular weight (MW) distribution, and molecular conformation of HA. For characterization of HA, AsFlFFF was operated by a simplified two-step procedure, instead of the conventional three-step procedure, where the first two steps (sample loading and focusing) were combined into one to avoid the adsorption of viscous HA onto the channel membrane. The simplified two-step AsFlFFF yielded reasonably good separations of HA molecules based on their MWs. The weight average MW (M(w) ) and the average root-mean-square (RMS) radius of HA extracted from rooster comb were 1.20×10(6) and 94.7?nm, respectively. When the sample solution was filtered through a 0.45?μm disposable syringe filter, they were reduced down to 3.8×10(5) and 50.1?nm, respectively.  相似文献   

15.
We developed a new system for random separation of a single microorganism, such as a living cell and a microbe, in the microfluidic device under the microscope by integrating the laser-trapping force and dielectrophoretic (DEP) force. An arbitrarily selected single microbe could be isolated in a microchannel, despite the presence of a large number of microbes in solution. Once the target microbe is trapped at the focal point of the laser, we can easily realize exclusion of excess microbes around the target by controlling the electric field, while keeping the target trapped by the laser at the focal point. To realize an efficient separation system, we proposed a new separation cell and produced it by microfabrication. Flow speed in the microchannel is adjusted and balanced to realize high-speed and high-purity extraction of the target. Some preliminary experiments are conducted to show the effectiveness. The target is trapped by the laser, transported, and is taken out from the extraction port. Total separation time is less than 20 s. Our method is extremely useful in the pure cultivation of the cell and will be a promising method for biologists in screening useful microbes.  相似文献   

16.
Laser photophoretic migration behavior of human blood cells in saline solution was investigated under the irradiation of Nd:YAG laser beam (532 nm) in the absence and the presence of the flow in a fused silica capillary. Red blood cells (RBC) were migrated faster than white blood cells (WBC) and blood pellets to the direction of propagation of laser light. The observed photophoretic velocity of RBC was about 11 times faster than those of others. This was understood from the larger photophoretic efficiency of RBC than that of WBC, which was simulated based on the Mie scattering theory. Furthermore, it was found that, during the photophoretic migration, RBCs spontaneously orientated parallel to the migration direction so as to reduce the drag force. Finally, it was demonstrated that RBC and WBC were separated in a micro-channel flow system by the laser photophoresis.  相似文献   

17.
We propose herein an improved microfluidic system for continuous and precise particle separation. We have previously proposed a method for particle separation called "pinched flow fractionation." Using the previously reported method, particles can be continuously separated according to differences in their diameters, simply by introducing liquid flows with and without particles into a specific microchannel structure. In this study, we incorporated PDMS membrane microvalves for flow rate control into the microfluidic device to improve the separation accuracy. By adjusting the flow rates distributed to each outlet, target particles could be precisely collected from the desired outlet. We succeeded in separating micron and submicron-size polymer particles. This method can be used widely for continuous and precise separation of various kinds of particles, and can function as an important part of microfluidic systems.  相似文献   

18.
Field-flow fractionation (FFF) is one of the most versatile separation techniques in the field of analytical separation sciences, capable of separating macromolecules in the range 103–1015 g mol−1 and/or particles with 1 nm–100 μm in diameter. The most universal and most frequently used FFF technique, flow FFF, includes three types of techniques, namely symmetrical flow FFF, hollow fiber flow FFF, and asymmetrical flow FFF which is most established variant among them. This review provides a brief look at the theoretical background of analyte retention and separation efficiency in FFF, followed by a comprehensive overview of the current status of asymmetrical flow FFF with selected applications in the field of biopolymers and bioparticles.  相似文献   

19.
In this article, a simple experimental approach to improve lipoprotein separation and detection in flow field-flow fractionation (FlFFF) is detailed. Lipoproteins are globular particles composed of lipids and proteins in blood serum and their roles include transferring fats and cholesterols through blood vessels throughout the body. Especially, presence of small, dense low-density lipoproteins (LDL) is associated with cardiovascular risk. Two experimental approaches were explored in this study: an increase in the reproducibility of LDL particle separation by implementing a guard channel prior to an asymmetrical FlFFF (AFlFFF) channel in order to deplete small molecular weight serum proteins and reducing the required injection volume of a serum sample by implementing fluorescence detection. The guard channel was made of a simple hollow fiber module so that the serum sample can be washed with the help of radial flow prior to injection into the AFlFFF channel. The channel was tested with protein standards and serum samples to ensure precision of the retention time and the protein recovery rate. A fluorescent phospholipid dye was utilized to label lipoprotein particles before separation for fluorescence detection, which resulted in a reduction of the required injection volume of serum.  相似文献   

20.
Different functions for the programming of the cross flow in asymmetrical flow field-flow fractionation were studied with the aim to find the flow conditions most suitable for the molar mass distribution analysis of high molecular weight polysaccharides. A mixture of four differently sized pullulans covering the molar mass range 5.8 x 10(3)-1.6 x 10(6) g mol(-1) were used as a model sample. Two types of programs were studied, linear and exponential decays, both with and without initial periods of a constant cross flow. For comparison, nonprogrammed runs, i.e. using constant cross flow, were studied. It was found that exponentially decaying cross flow gave the most uniform molar mass selectivity across the fractogram. The programmed cross flow was applied to the molar mass distribution analysis of a technical quality of hydroxypropyl cellulose.  相似文献   