共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
为了在保证结构简单的前提下,实现衍射光栅精密测量系统的大量程、高精度、多维度测量,设计了能够同时测量位移和角度的五维自由度衍射光栅精密测量系统。基于利特罗对称式光路结构,采用高刻线密度的一维衍射光栅以及外差干涉原理实现了沿光栅矢量方向和光栅法线方向的二维位移测量;通过引入高精度的位置灵敏探测器,结合±1级衍射光与光栅之间的角度变化关系实现了对光栅俯仰、偏摆和滚转三个维度的角度误差测量。实验结果表明:该衍射光栅精密测量系统能够实现分辨力优于4 nm的二维位移测量以及分辨力优于1″的三维角度测量,其位移测量范围只受限于光栅的尺寸,量程大大增加。该衍射光栅精密测量系统在精密测量领域有重要意义。 相似文献
3.
Christian Smorra Pascal E. Blessing Matthias J. Borchert Jack A. Devlin James A. Harrington Takashi Higuchi Jonathan Morgner Hiroki Nagahama Stefan Sellner Matthew A. Bohman Andreas H. Mooser Georg L. Schneider Natalie Schön Markus Wiesinger Klaus Blaum Yasuyuki Matsuda Christian Ospelkaus Wolfgang Quint Jochen Walz Yasunori Yamazaki Stefan Ulmer 《Hyperfine Interactions》2018,239(1):47
We summarize our recent 1.5 parts per billion measurement of the antiproton magnetic moment using the multi Penning-trap system of the BASE collaboration. The result was achieved by combining the detection of individual spin-transitions of a single antiproton with a novel two-particle spectroscopy technique, which dramatically improved the data sampling rate. This measurement contributes to improve the test of the fundamental charge, parity, time reversal (CPT) invariance in the baryon sector by a factor of 350 compared to our last measurement, and by a factor of 3000 compared to the best competing measurement. We review the measurement technique and discuss the improved limits on CPT-violating physics imposed by this measurement. 相似文献
4.
高精度测距在工业、航空航天、科学研究等方面都具有重要应用, 而不断发展的激光测距技术始终处于前沿研究领域. 本文研究飞秒光频梳绝对测距技术, 拓展光梳在长度测量领域的应用. 在利用脉冲激光进行任意绝对长度测量中常用到飞行时间法, 然而其测量分辨力受限于电子器件的带宽, 仅为毫米量级. 为克服这一缺点, 本文研究了光梳多脉冲序列之间的时间相干性, 结合多脉冲序列干涉法和飞行时间法提出了任意长绝对测距的方法, 搭建了基于改进型Michelson干涉原理的任意绝对测长系统, 通过同时测量多脉冲序列的一阶和二阶互相关信号, 可以分别计算出飞行时间的时间差, 即可得到被测距离. 利用光梳作为光源进行了0.6m的绝对测距实验, 将测量结果与高精度激光位移传感器的测量值进行比较, 实验结果表明本系统具有良好的测量线性度, 并且测距精度可达±0.5μm.
关键词:
飞秒光频梳
任意长绝对测距
飞行时间法
多脉冲序列干涉法 相似文献
5.
双目视觉测量系统利用三角测量法原理进行三维测量,其结构特性决定了测量误差随测量距离的增加而增大。针对测量误差的分布规律,该文提出基于局部视场的双目视觉测量系统优化方法。利用外在结构建立测量坐标系,减小标定和测量过程信息非一致性引入的系统误差;利用相机参数之间的耦合作用补偿系统固有参数标定误差并建立查找表,建立关于标定参数的虚拟映射。模拟实验最大误差小于0.03 mm,系统实验误差小于0.3%,实验表明优化后系统主要测量误差来源于探测器离散化引入的随机误差,双目视觉测量系统达到理论测量精度。 相似文献
6.
基于位置敏感器件的光学法盐度检测技术研究 总被引:6,自引:4,他引:2
盐水浓度的变化会引起其对光的折射率的变化 ,对于固定的倾斜入射光线 ,折射率的变化会导致出射光线发生偏移 ,利用位置敏感器件 (PSD)检测光线偏移量的大小 ,便可以得到待测盐水的浓度。基于差动折射率测量原理 ,引入了一个装有蒸馏水的参考水槽 ,从而有效地减小了温度漂移对盐度测量带来的影响。初步的实验结果表明了方法的正确性 ,盐度测量的分辨力可达 0 .0 12‰ ,重复性精度好于± 0 .3‰。对测量数据做了详细的论述 ,并对影响测量精度的一些主要因素进行了细致的分析。结果表明 ,该方法的温度漂移和光源强度变化对测量结果的影响很小。 相似文献
7.
8.
Masashi Ban 《International Journal of Theoretical Physics》1997,36(12):2583-2638
State change, quantum probability, and information gain in the operational phasespace measurement are formulated by means
of positive operator-valued measure (POVM) and operation. The properties of the operational POVM and its marginal POVM which
yield the quantum probability distributions of the measurement outcomes obtained by the operational phase-space measurement
are investigated. The Naimark extension of the operational POVM can be expressed in terms of the relative-position states
and the relative-momentum states in the extended Hilbert space. An observable quantity measured in the operational phase-space
measurement becomes a fuzzy or unsharp observable. The state change of a physical system caused by the operational phase-space
measurement is described by the operation which is obtained explicitly for the position and momentum measurements and for
the simultaneous measurement of position and momentum. Using the results, the entropy change of the measured physical system
and the information gain in the operational phase-space measurement are investigated. It is found that the average value of
the entropy change is equal to the Shannon mutual information extracted from the outcomes exhibited by the measurement apparatus. 相似文献
9.
近红外光谱法成分检测因其检测方法的优越性,已成为生物医学领域的研究热点。目前国内外相关研究虽然广泛,可是还没有进入实际临床应用的报道。关键是现有检测方法中存在着个体差异,测量条件的影响,使光谱检测精度达不到要求,因此提高检测精度是血液成分无创检测得以实现的关键。文章在最近提出的一种新的近红外血液成分检测方法-动态光谱法的基础上,利用传统的统计处理方法,通过剔除含有粗大误差的奇异点和多次测量统计平均来提高动态光谱检测精度。实验结果表明含粗大误差的奇异点剔除和多次测量统计平均能够提高动态光谱的检测精度。 相似文献
10.
11.
光谱辐照度是光谱辐射计量中最基本的参数,是研究各种辐射源及光电探测器特性的重要依据。为提高光谱辐照度的测量精度和量值溯源等问题,国防科工委光学计量一级站采用BB3200K高温黑体作为基准的辐射源,以新型辐射测温法为基础,通过一系列光辐射理论和几何原理推导出辐射温度与辐射光功率之间的关系;通过对光辐射功率的绝对测量,并结合低温辐射计,从而完成了光谱辐照度量值的精度测量。该理论奠基了以探测器为基础的新的光辐射量传体系。主要介绍了在光谱辐照度标准装置的项目中复现光谱辐照度所建立的数学模型及新的测试方法,给出了测量结果,并简要介绍了基于该理论的测量装置的组成及原理。 相似文献
12.
13.
结构光测量中获取高精度相位的新方法 总被引:10,自引:6,他引:4
随着制造技术的快速发展.三维光学测量技术也得到迅速的发展,利用双目CCD(电耦合插件)摄像机记录的光栅投影测量技术是一种新型的光学测量方法。在该方法的测量过程中,通过测量相位值取得测量空间。为了获得连续的高精度测量相位值.提出一种结合了格雷(Gray)编码并能够优化相位精度的相移方法,该方法通过投影相位传递函数来优化测量相位值。为了消除光栅投影图像中非正弦、周期变化和其他干扰因素的影响,给出投影光栅一种新的光强函数,利用这个光强函数能够进一步提高投影光栅测量相位精度。最终,通过插值测量相位精度能达到亚像素级. 相似文献
14.
针对非理想参考反射标准对光谱发射率测量结果的影响,基于积分球反射计的红外发射率测量系统原理,提出了一种适用于反射法光谱发射率测量系统的校正方法。通过参考反射标准样光谱反射率的数据拟合,得到反射率的曲线方程,计算反射测量系统的校正系数,校正参考标准样的输出电压,推导出光谱反射率为1的参考标准样输出电压曲线,消除了非理想参考标准造成的系统误差。应用该修正方法对基于积分球反射计的太阳能选择吸收涂层光谱发射率测量系统进行了校正,将校正后的光谱发射率测量结果与能量比较法的测量结果进行对比,验证了校正方法的可行性,有效性,提高了光谱发射率测量的准确度。 相似文献
15.
三波长测温中波长选取原则的理论分析 总被引:1,自引:0,他引:1
建立了在窄波段内具有普适性的无量纲化线性发射率模型,对基于此模型而提出三波长温度测量法,着重说明了三波长法适用的测量条件以及3个测量波长的选取原则。在波长选取原则的理论分析中,通过优化分析,依据由测量坐标而引出的等温线的概念,提出了两种理想测量的波长优化准则,从而为该方法的技术实现提供了重要的理论指导,同时该准则的优化思想也适用于多波长法的波长选取。 相似文献
16.
一种单双目视觉系统结合的三维测量方法 总被引:9,自引:3,他引:6
在投影栅相位法的单日和双目三维测量结构的基础上,提出了一种单双目结合的三维测量方法.采用双目测量系统的架构,对两相机的公共区域使用双目的方法进行复现,同时分别将两个相机与投影仪组成两个单目测量系统,通过标定的统一可以将两者的世界坐标系统一到一个共同的基准上,利用单目的测量结果对双目测量的哪缺失区域进行填补.在对石膏头像的测量中,利用该方法避免了双目测量中在鼻梁附近出现的数据丢失.在保证双目复现区域精度的基础上,该方法有效地改进了测量结果的完整性. 相似文献
17.
18.
测量大尺寸零部件一般需要较大的测量范围,而高精密扫描传感器往往视野较小。为了解决该矛盾,提出了一种基于机械式拼接的结构光扫描测量方法,通过结构光扫描仪获取局部高精点云,并利用高精十字平移台实现数据拼接。分析了测量系统的组成和测量原理,提出了一种基于加权非线性优化的外参标定方法,求解出结构光扫描仪和十字平移台之间非实物坐标系的变换关系。在实验中验证了系统在300 mm的测量范围内球心距的均方根误差(root-mean-square error,RMSE)优于45 μm;同时对实物进行了测量,检验了测量系统的实用性。 相似文献
19.
形位误差的测量不确定度评定是目前测量领域研究的热点;但由于其测量的复杂性和测量结果评定的多样性,导致在实际测量结果中形位误差测量的不确定度评定成了难题;为此,根据形状误差评定准则,选取最小二乘法建立数学模型,确定形状误差数学模型中各参数值的传递系数和单点不确定度,并分析具体的测量方法和测量过程中的不确定度来源,根据传统的GUM法对其进行不确定度评定;然后采用蒙特卡罗伪随机数的方法来模拟实际测量数据,从而得到平面度误差的不确定度;通过设置实验对比,验证了蒙特卡罗法评定平面度不确定度的可靠性和准确性;该方法不需要求出数学模型中的传递系数,利用MATLAB软件很容易实现,为平面度误差测量结果不确定度评定提供了更加简便的方法,值得推广和应用。 相似文献