首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this study, a novel capillary electrophoresis (CE)-based enzymatic assay was developed to evaluate enzymatic activity in whole cells. β-Galactosidase expression was used as an example, as it is a biomarker for assessing replicative senescence in mammalian cells. It catalyzes the hydrolysis of para-nitrophenyl-β-d-galactopyranoside (PNPG) into para-nitrophenol (PNP). The CE-based assay consisted of four main steps: (1) hydrodynamic injection of whole intact cells into the capillary, (2) in-capillary lysis of these cells by using pulses of electric field (electroporation), (3) in-capillary hydrolysis of PNPG by the β-galactosidase—released from the lysed cells—by the electrophoretically mediated microanalysis (EMMA) approach, and (4) on-line detection and quantification of the PNP formed. The developed method was applied to Escherichia coli as well as to human keratinocyte cells at different replicative stages. Results obtained by CE were in excellent agreement with those obtained from off-line cell lysates which proves the efficiency of the in-capillary approach developed. This work shows for the first time that cell membranes can be disrupted in-capillary by electroporation and that the released enzyme can be subsequently quantified in the same capillary. Enzyme quantification in cells after their in-capillary lysis has never been conducted by CE. The developed CE approach is automated, economic, eco-friendly, and simple to conduct. It has attractive applications in bacteria or human cells for early disease diagnostics or insights for development in biology.
Figure
Electropherograms for in-capillary reaction catalyzed by β-galactosidase obtained from off-capillary and in-capillary lysis of E. coli cells.  相似文献   

2.
田苗苗  杨丽 《色谱》2020,38(10):1143-1153
毛细管电泳技术具有操作简单、样品消耗量少、分离效率高和分析速度快等优势,不仅是一种高效的分离分析技术,而且已经发展成为在线酶分析和酶抑制研究的强有力工具。酶反应全程的实时在线监测,可以实现酶反应动力学过程的高时间分辨精确检测,以更准确地获得反应机制和反应速率常数,有助于更好地了解酶反应机制,从而更全面深入地认识酶在生物代谢中的功能。此外,准确、快速的在线酶抑制剂高通量筛选方法的发展,对加快酶抑制类药物的研发以及疾病的临床诊断亦具有重要意义。电泳媒介微分析法(EMMA)和固定化酶微反应器(IMER)是毛细管电泳酶分析技术中常用的在线分析方法。这两种在线酶分析法的进样方式通常为流体动力学进样和电动进样,无法实现酶反应过程中的无干扰序列进样分析。近年来,基于快速序列进样的毛细管电泳序列分析技术已经发展成为在线酶分析的另一种强有力手段,以实现高时间分辨和高通量的酶分析在线检测。该文从快速序列进样的角度,综述了近年来毛细管电泳序列分析技术在线酶分析的研究进展,并着重介绍了各种序列进样方法及其在酶反应和酶抑制反应中的应用,包括光快门进样、流动门进样、毛细管对接的二维扩散进样、流动注射进样、液滴微流控进样等。  相似文献   

3.
This review provides systematic coverage of examples in the field of in-capillary electrophorecially mediated microanalysis (EMMA). The recent developments and applications in the time period up to mid 2011 have been described, as well as relevant older papers. The basic principles and modes of in-capillary assays have been demonstrated. An overview is also given of the various injection, separation and detection modes implemented in combination with EMMA. The review is presented in two parts mainly dealing with (i) enzymatic and (ii) derivatization or chemical reactions. Finally, the future trends of CE in performing and monitoring reactions have been drawn.  相似文献   

4.
Capillary electrophoresis is a modern separation technique characterized by many benefits, which qualify it also for enzyme assays and the study of enzyme kinetics during drug development. Homogeneous or heterogeneous approaches can be followed for the enzymatic incubation. In this study, an immobilization procedure of aldehyde oxidase on magnetic particles was developed considering their integration with capillary electrophoresis. A number of magnetic nano/microparticle types were tested for this purpose, showing that aldehyde oxidase was most active when immobilized on bare silica magnetic nanoparticles. Primarily, the reusability of the enzyme immobilized on bare silica nanoparticles was tested. Three consecutive incubations with substrate could be performed, but the activity considerably dropped after the first incubation. One reason could be an enzyme detachment from the nanoparticles, but no release was detected neither at 4°C nor at 37°C during 5 h. The drop in enzymatic activity observed in consecutive incubations, could also be due to inactivation of the enzyme over time at given temperature. For the immobilized enzyme stored at 4°C, the activity decreased to 83% after 5 h, in contrast with a steep decrease at 37°C to 37%.  相似文献   

5.
This study presents the in-capillary enzymatic biotransformation of dextromethorphan, an antitusive drug and opioid receptor antagonist, and subsequent electrophoretic separation of its products. The study includes the optimization of separation parameters to fulfill the requirements of an online microreaction. The analyses were performed in a bare fused-silica capillary using 100 mM sodium tetraborate (pH 10.0) mixed with linear polyacrylamide (20%, v/v) and 2-propanol (10%, v/v). This BGE was suitable for monitoring both off-line and in-capillary incubations. The partial filling technique enabled the enzymatic reaction to be carried out in its optimal environment (20 mM sodium phosphate, pH 7.4). Finally, in-capillary microreaction in the presence of cytochrome P450 3A4 gave satisfactory outcomes.  相似文献   

6.
宋佳一  李梦琦  沈昊  周梓昕  贺雯婷  苏萍  杨屹 《色谱》2020,38(10):1206-1210
生物酶影响着物质代谢和质能转换等生命活动,生物体内某些酶的活性变化会导致疾病的发生。发展新型的酶分析方法对深刻理解生物代谢过程、疾病诊断和药物研发等具有重要意义。毛细管电泳(CE)具有分离效率高、分析速度快、操作简单和样品消耗少以及可与多种检测手段联用等优点,在酶分析研究中越来越受到关注。CE酶分析主要包括离线和在线两种模式,其中,固定化酶微反应器与毛细管电泳联用(CE-IMER)的在线酶分析已经成为主要的酶分析方法之一。CE-IMER充分结合了固定化酶和CE的优势,将游离酶固定在毛细管内,不仅可以显著提高酶的稳定性和重复使用性,而且可以实现纳升规模溶液的自动化酶分析,进而显著降低酶分析成本。目前已有大量方法制备IMER用于CE酶分析,然而如何构建性能良好、可再生使用、酶固载量大、自动化程度高的CE-IMER一直是该领域重点研究的问题。DNA定向固定化技术(DDI)可以充分利用DNA分子的碱基互补配对(A-T,C-G),在温和的生理条件下特异性固定生物大分子。由于短链双螺旋DNA分子具有较强的机械刚性和物理化学稳定性,通过DDI将酶固定在载体表面,有利于降低传质阻力,提高酶与底物的接触能力,进而促进酶促分析过程。该文主要综述了利用DDI构建新型IMER在CE酶分析中的应用现状,并对其未来发展进行了展望。  相似文献   

7.
Chen SH  Chen YH 《Electrophoresis》1999,20(15-16):3259-3268
This review briefly discusses the use of capillary electrophoretic (CE) methods for the investigations of different aspects of pharmacokinetics. In most investigations, CE was the method of choice because of its unique features, including high resolving power for chiral or metabolite separation, small sample volume for pediatric pharmacokinetics or for cell-based investigations, in situ microdialysis sampling for rapid eliminations, low UV wavelength detection for nonderivatized analytes, fast and simplified sample processing for existing methods that require tedious sample preparation, or as a second method for verifications. Moreover, instrumental aspects of CE-based assays for pharmacokinetic studies, such as different modes of CE methods for analyzing biological samples, sample stacking for increasing detection sensitivity, and coupling techniques with microdialysis and mass spectrometry, are also discussed in this review. Furthermore, the advantages and limitations of CE methods as well as the future outlook for pharmacokinetic studies are summarized.  相似文献   

8.
This review describes the quantitative analysis of in-capillary reactions by using capillary electrophoresis (CE) in the food industry. An electrophoretic analysis of products of an enzyme reaction of a substrate by in-capillary reaction was useful for the activity measurement of glucoamylase in sake rice koji. p-Nitrophenyl-beta-D-maltoside was employed as a substrate and p-nitrophenyl-beta-D-glucopyranoside was the product of the enzyme reaction. The glucoamylase activity of sake rice koji samples gave a good linear relationship with the peak area observed in the in-capillary enzyme reaction method. Also, in-capillary micellar electrokinetic chromatography (MEKC) was used for analyzing the Monascus pigment-mediated degradation of mutagenic 3-hydroxyamino-1-methyl-5H-pyrido[4,3-b]indole. During the electrophoresis, the mutagen and the pigment, due to their different migration velocities, mix for a certain period of time to interact, and then they are separated and quantitated. The in-capillary reaction MEKC method can be applied to the routine quality control of enzyme activities in the food industry and the evaluation of mutagenic compounds in food materials.  相似文献   

9.
An in-capillary electrode sheathless interface was applied to the capillary electrophoresis/electrospray ionization-mass spectrometry (CE/ESI-MS) analysis of mixtures of small peptides, proteins, and tryptic digests of proteins. The effects of different experimental parameters on the performance of this CE/ESI-MS interface were studied. The distance of the in-capillary electrode from the CE outlet and the length of the electrode inside the capillary had no significant effects on the CE separation and ESI behavior under the experimental conditions used. However, significant enhancement of the sensitivity resulted from the use of narrower CE capillaries. Using a quadrupole mass spectrometer, an aminopropylsilane-coated capillary, and a wide scan mass-to-charge ratio range of 500–1400, detection limits of approximately 4, 1, and 0.6 fmol for cytochrome c and myoglobin were achieved for 75-, 50-, and 30-µm inner diameter capillaries, respectively. Approximately one order of magnitude lower detection limits were achieved under the multiple-ion monitoring mode. The application of the in-capillary electrode sheathless interface to real-world samples was demonstrated by CE/ESI-MS analysis of a human blood sample.  相似文献   

10.
Moser AC  Hage DS 《Electrophoresis》2008,29(16):3279-3295
The use of CE as a tool to conduct immunoassays has been an area of increasing interest over the last decade. This approach combines the efficiency, small sample requirements, and relatively high speed of CE with the selectivity of antibodies as binding agents. This review examines the various assay formats and detection modes that have been reported for these assays, along with some representative applications. Most CE immunoassays in the past have employed homogeneous methods in which the sample and reagents are allowed to react in solution. These homogeneous methods have been conducted as both competitive binding immunoassays and as noncompetitive binding immunoassays. Fluorescent labels are most commonly used for detection in these assays, but enzyme labels have also been utilized for such work. Some additional work has been performed in CE immunoassays with heterogeneous methods in which either antibodies or an analog of the analyte is immobilized to a solid support. These heterogeneous methods can be used for the selective isolation of analytes prior to their separation by CE or to remove a given species from a sample/reagent mixture prior to analysis by CE. These CE immunoassays can be used with a variety of detection modes, such as fluorescence, UV/Vis absorbance, chemiluminescence, electrochemical measurements, MS, and surface plasmon resonance.  相似文献   

11.
Lin CC  Li YT  Chen SH 《Electrophoresis》2003,24(22-23):4106-4115
This review is a continuation of the previous reviews (Electrophoresis 1999, 20, 3259-3268; Electrophoresis 2001, 22, 4244-4248) to update the recent publications from 2001 to 2003 on pharmacokinetic studies using capillary electrophoresis (CE). During this period of time, CE remains as a unique analytical method for some studies, which would otherwise be limited by many factors, such as the sample volume, detection sensitivity, or separation power. It is particularly noticeable that the separation of chiral drugs in biological sample and the use of solid-phase extraction (SPE) as a simple and convenient means of sample preparation appear to become popular for CE-based assays. The use of CE for assessing complete pharmacokinetic information, however, did not show a significant growth during this period of time. In order to provide a broad range of view on how biological samples are analyzed by CE, this review will cover publications during the past two years on the use of CE for the analysis of drugs in biological fluids for general pharmacokinetic applications including drug monitoring and bioavailability studies.  相似文献   

12.
A new capillary electrophoresis (CE) method was developed for the rapid, simple and selective determination of thiosulfate, sulfide and sulfite species. The proposed method is based on the in-capillary derivatization of separated sulfur anions by mixing their zones with the iodine zone during the electrophoretic migration and direct UV detection of iodide formed. The optimal conditions for the separation and derivatization reaction were established by varying electrolyte pH, electrolyte counter-ion, concentration of iodine, and applied voltage. The optimized separations were carried out in 20 mmol/L Tris-chloride electrolyte (pH 8.5) using direct UV detection at 214 nm. All three sulfur species were well resolved in less than 4 min. The method gives repeatability comparable or even better than this obtained for sulfur anions using standard CE technique. The proposed CE system was applied to the monitoring of sulfur anions in spent fixing solutions during the electrolytic oxidation.  相似文献   

13.
Iqbal J  Burbiel JC  Müller CE 《Electrophoresis》2006,27(12):2505-2517
Fast and convenient CE assays were developed for the screening of adenosine kinase (AK) inhibitors and substrates. In the first method, the enzymatic reaction was performed in a test tube and the samples were subsequently injected into the capillary by pressure and detected by their UV absorbance at 260 nm. An MEKC method using borate buffer (pH 9.5) containing 100 mM SDS (method A) was suitable for separating alternative substrates (nucleosides). For the CE determination of AMP formed as a product of the AK reaction, a phosphate buffer (pH 7.5 or 8.5) was used and a constant current (95 microA) was applied (method B). The methods employing a fused-silica capillary and normal polarity mode provided good resolution of substrates and products of the enzymatic reaction and a short analysis time of less than 10 min. To further optimize and miniaturize the AK assays, the enzymatic reaction was performed directly in the capillary, prior to separation and quantitation of the product employing electrophoretically mediated microanalysis (EMMA, method C). After hydrodynamic injection of a plug of reaction buffer (20 mM Tris-HCl, 0.2 mM MgCl2, pH 7.4), followed by a plug containing the enzyme, and subsequent injection of a plug of reaction buffer containing 1 mM ATP, 100 microM adenosine, and 20 microM UMP as an internal standard (I.S.), as well as various concentrations of an inhibitor, the reaction was initiated by the application of 5 kV separation voltage (negative polarity) for 0.20 min to let the plugs interpenetrate. The voltage was turned off for 5 min (zero-potential amplification) and again turned on at a constant current of -60 microA to elute the products within 7 min. The method employing a polyacrylamide-coated capillary of 20 cm effective length and reverse polarity mode provided good resolution of substrates and products. Dose-response curves and calculated K(i) values for standard antagonists obtained by CE were in excellent agreement with data obtained by the standard radioactive assay.  相似文献   

14.
The use of capillary electrophoresis for the determination of gamma-glutamyltransferase (GGT) activity with gamma-glutamyl-p-nitroanilide (Glu-p-NA) as a substrate was investigated. The reaction velocity was quantified spectrophotometrically by the corrected peak area of the product p-nitroaniline (pNA) at 380 nm. Micelles composed of sodium deoxycholic acid were used in the background electrolyte in order to obtain a baseline separation between the substrate and the product. The presence of the micelles did not influence the enzymatic reaction. The electrophoretic system was used, not only for the separation and quantitation of the different reaction compounds but also for the in-capillary mixing of the enzyme and substrate plugs. This methodology is known as electrophoretically mediated microanalysis (EMMA). With the developed in-capillary activity assay an average Michaelis constant (K(M)) for GGT was calculated to be 2.09 mM (RSD = 7.3%, n = 3), a value consistent with previously reported values.  相似文献   

15.
The utility of multi-walled carbon nanotubes (MWNTs) to decrease the interaction between cytochrome P450 enzymes and the capillary wall during in-capillary enzymatic incubation was investigated. First, 18 surfactants were screened to determine their MWNT-dispersing capacity. A probe sonication procedure was developed in order to attain homogeneous MWNT dispersions within a reasonable time. Next, the influence of surfactants and MWNTs on P450 activity was studied, employing verapamil and CYP3A4 as model substrate and P450 isoform, respectively. MWNTs dispersed in Brij 35 did not affect CYP3A4 activity significantly and were selected for subsequent in-capillary tests. An in-line CE assay, involving electrophoretic mixing of reagents and zero potential amplification in the thermostatted part of the capillary, was developed. In-capillary incubations without MWNTs caused adsorption of enzyme to the capillary wall and a concomitant decline of capillary lifetime, even when extensive between-run rinsing was applied. Addition of MWNTs to the enzyme solution entailed substantial improvement of migration time and peak shape repeatability. The performance of three types of MWNTs was compared.  相似文献   

16.
Suresh Babu CV  Cho SG  Yoo YS 《Electrophoresis》2005,26(19):3765-3772
Signal transduction studies have indicated that Akt is essential for transducing the signals originating from extracellular stimuli. An exploration of the Akt signal transduction mechanism depends on the ability to assay its activation states by determining the ability of Akt to phosphorylate various substrates. This paper describes a CE-based kinase assay for Akt using a UV detection method. The RPRAATF peptide was used as the specific substrate to determine the Akt activity. Under the CE separation conditions used, the phosphorylated and nonphosphorylated forms of the RPRAATF peptide were rapidly resolved in the Akt reaction mixture within 20 min. Using this method for measuring the Akt activity, the incubation time for the Akt reactions as well as the kinetic parameters (KM) were examined. Furthermore, the developed method was applied to a PC12 cell system to assess the dynamics of the Akt activity by examining the effectiveness of the RPRAATF peptide substrate under various cytokine-stimulated environments. These results highlight the feasibility of the CE method, which is a simple and reliable technique for determining and characterizing various enzyme reactions particularly kinase enzymes.  相似文献   

17.
Xanthine oxidase (XOD) is a key enzyme in the human body to produce uric acid, and its inhibitor can be used for the treatment of hyperuricemia and gout. In this study, an online CE-based XOD immobilized enzyme microreactor (IMER) was developed for the enzyme kinetics assays and inhibitor screening. After 30 consecutive runs, the XOD activity remained about 95.6% of the initial immobilized activity. The Michaelis–Menten constant (Km) of the immobilized XOD was determined as 0.39 mM using xanthine as substrate. The half-maximal inhibitory concentration and inhibition constant of the known inhibitor 4-aminopyrazolo[3,4-d]pyrimidine on XOD were determined as 11.9 and 5.2 μM, respectively. Then, the developed method was applied to evaluate the XOD inhibitory activity of 10 flavonoids, which indicated that dihydroquercetin, quercetin, biochanin A, and epicatechin had significant inhibitory effect on XOD. In addition, molecular docking results verified that the binding energy of the flavonoids with enzyme were in line with their inhibitory activity determined by XOD–IMER. Therefore, the developed XOD–IMER is a potential tool for the primary screening of XOD inhibitors from natural products.  相似文献   

18.
Sung WC  Chen SH 《Electrophoresis》2001,22(19):4244-4248
This article reviews recent capillary electrophoresis (CE)-based assays which were published for pharmacokinetic studies. Both the advantages and disadvantages of these CE-based assays are discussed based on their feasibility and the significance towards the better understanding of pharmacokinetics. In addition, as a future outlook, novel assays such as immunoaffinity CE and chip-based CE for analyzing drugs in biological fluids are summarized in view of their potential for pharmacokinetic applications.  相似文献   

19.
Sung WC  Chen SH 《Electrophoresis》2006,27(1):257-265
This article covers recent publications from 2003 to 2005 on the subject of pharmacokinetic applications of CE. Many analytical methods were validated and more importantly, they were shown to have sufficient sensitivities to access pharmacokinetic data on different models. Because of unique advantages, such as simplified sample preparation methods, small sample amount required, high separation power, and speedy analysis, CE-based assays were found to gain popularity not only as a second method but also as a major method for many pharmacokinetic studies.  相似文献   

20.
Electrophoretically mediated microanalysis (EMMA) was applied for the study of the kinetic parameters of the enzymatic reaction of phenol sulfotransferase SULT1A1 isoenzyme with 4-nitrophenol as a substrate. The SULT1A1 activity was determined by the quantitation of the product, 4-nitrophenyl sulfate, at 274 nm by using different injection and separation steps. This new approach solved the problem of the presence of the very strong inhibitor, adenosine 3',5'-bisphosphate (PAP), in the co-substrate solution (adenosine 3'-phosphate 5'-phosphosulfate, PAPS) which is unstable at room temperature. The inhibitor PAP was electrophoretically separated from the co-substrate PAPS before the injection of enzyme and substrate inside the capillary (and thus before their in-capillary encountering). With the developed in-capillary SULT1A1 activity assay an average Michaelis constant (Km) for 4-nitrophenol was calculated to be 0.84 microM, a value which is consistent with a previously reported value. Strong substrate inhibition (above a 4-nitrophenol concentration of 2.5 microM) was observed, and this is also in accordance with literature values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏