首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple, fast and sensitive LC?CMS/MS method was developed and validated for the simultaneous determination of the concentrations of temsirolimus and its major metabolite, sirolimus, in human whole blood. The blood sample (100???L) after adding temsirolimus-d7 and sirolimus-d3 internal standards was precipitated with 0.200?mL of methanol/0.300?M zinc sulfate (70/30, v/v), then analyzed by a Shimatzu LC system coupled to a Sciex API-5000 mass spectrometer. The chromatographic separation was carried out on a BDS Hypersil C8 column (50?×?3.0?mm, 5???m) at 50?°C with a mobile phase composed of methanol/water/formic acid (72/28/0.1) (v/v/v) containing 2.50?mM ammonium acetate. Mass spectrometric detection was performed using electrospray positive ionization with multiple reaction monitoring mode. This method was validated from 0.250 to 100?ng?mL?1 for temsirolimus and 0.100 to 40.0?ng?mL?1 for sirolimus. The lower limits of quantitation were 0.25?ng?mL?1 for temsirolimus and 0.1?ng?mL?1 for sirolimus. The intra-day and inter-day precisions (CV?%) of spiked quality control (QC) samples were less than 10.4 and 9.6?%, respectively. The accuracies as determined by the relative error for QC samples were less than 12.1?% for intra-day and 7.3?% for inter-day. No significant matrix effect was observed. This method has been successfully applied to analyze clinical pharmacokinetic study samples. The assay reproducibility was also demonstrated by using incurred samples.  相似文献   

2.
3.
A selective, rapid and sensitive liquid chromatography tandem mass spectrometry method has been developed for the simultaneous determination of ramipril and ramiprilat in human plasma using enalapril as the internal standard via one-step extraction with ethyl acetate under acidic condition. The analysis was carried out on a Diamonsil C18 column (150 mm × 4.6 mm i.d., 5 μm) with a mobile phase consisting of 1% formic acid-acetonitrile (25:75, v/v) at a constant flow rate of 0.5 mL min?1. The detection was performed on a triple-quadruple tandem mass spectrometer by selective reaction monitoring mode via electrospray ionization. Linear calibration curves of ramipril and ramiprilat were obtained in the concentration range of 0.107–107.0 and 0.262–105.0 ng mL?1, respectively. The intra- and inter-day precision (RSD) values were below 8.2 and 4.8% for ramipril, 10.4 and 12.3% for ramiprilat, and accuracy (RE) were within ±5.5 and ±3.2%, respectively at all QC levels. The method was utilized to support clinical pharmacokinetic studies in healthy volunteers following oral administration of ramipril tablets.  相似文献   

4.
5.
An alternative rapid and sensitive liquid chromatography–tandem mass spectrometry method has been developed and validated for simultaneous analysis of proguanil (PRO) and cycloguanil (CYC) in human plasma. The analytes were extracted from human plasma by solid phase extraction. Riluzole (RIL) was used as an internal standard for proguanil and cycloguanil. A HyPURITY Advance C18 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The method involves simple isocratic chromatography conditions and mass spectrometric detection in the positive ionization mode using an API-4000 system. The proposed method has been validated with linear range of 1.5–150.0 ng mL?1 for PRO and 0.5–50.0 ng mL?1 for CYC. The inter-run and intra-run precision values are within 2.54, 9.19% for PRO and 1.99, 10.69% for CYC at LOQ levels. The overall recoveries for PRO and CYC were 102.52 and 106.72%, respectively. Total elution time was as low as 2.50 min. This validated method was used successfully for analysis of plasma samples from a bioequivalence study.  相似文献   

6.
A sensitive and rapid LC–MS–MS method was developed for the simultaneous determination of ebastine and carebastine in human plasma. Solid-phase extraction was used to isolate the compounds from the biological matrix followed by separation on a Symmetry C18 column under isocratic conditions. The mobile phase was 10 mM ammonium formate in water/acetonitrile (40:60, v/v). Detection was carried out using a triple-quadrupole mass spectrometer in positive electrospray ionization and multiple reaction monitoring mode. The method was fully validated over the concentration range of 0.1–10 ng mL?1 for ebastine and 0.2–200 ng mL?1 for carebastine in human plasma, respectively. The lower limit of quantification (LLOQ) was 0.1 ng mL?1 for ebastine and 0.2 ng mL?1 for carebastine. For ebastine and carebastine inter- and intra-day precision (CV%) and accuracy values were all within ±15% and 85–115%, respectively. The extraction recovery was on average 60.0% for ebastine and 60.3% for carebastine.  相似文献   

7.
8.
A rapid and sensitive liquid chromatographic–tandem mass spectrometric method has been developed and validated for the estimation of sarpogrelate in human plasma. Sarpogrelate was extracted from human plasma by solid-phase extraction. Temocapril was used as the internal standard. Heated electron spray ionization mass spectrometry was performed on a TSQ Quantum Ultra MS system. The LC column was a Hypurity C18 and the mobile phase was 2 mM ammonium formate (pH 3.00 ± 0.05):acetonitrile (30:70 v/v). A flow rate of 0.250 mL min?1 was used. The quantitative analyses were carried out in the positive ion and full scan mode over the mass range m/z 60–500. The capillary, vaporiser temperatures were 325 and 200 °C respectively. The sheath gas pressure, spray voltage, collision energy and tube lense were 40, 3,500 V, 19 V, 198 V, respectively, and the mass spectra of the drugs were recorded by total ion monitoring. Retention times and characteristic mass fragments were recorded and the chosen diagnostic mass fragments were monitored in the mass chromatography mode. Signal intensities of each of the mass fragments: m/z 477 [M + H]+ for temocapril, m/z 430 [M + H]+ for sarpogrelate, were used for quantification. The calibration curves (the ratio between the peak areas as signal intensities of the drug analyzed and that of the internal standard (temocapril: m/z 477 [M + H]+) vs. the concentration of drug) exhibited linearity over the concentration range 5.00–2,500.00 ng mL?1 human plasma. The recovery and the accuracy were calculated by comparing the peak areas as the signal intensities of each mass fragment for the drug in spiked samples after solid-phase extraction from human plasma to the peak area as the signal intensity of the mass fragment of internal standard sample. The method involves a rapid solid phase extraction from plasma, simple isocratic chromatography conditions and mass spectrometric detection that enables detection up to picogram levels with a total run time of 3.0 min only. The method was validated over the range of 5.0–2,500.0 ng mL?1. The absolute recoveries for sarpogrelate (93.72%) and IS (91.42%) achieved from spiked plasma samples were consistent and reproducible.  相似文献   

9.
A sensitive and specific liquid chromatography–electrospray ionization–tandem mass spectrometry method has been developed and validated for the quantification of huperzine A in human plasma. After the addition of trimetazidine, the internal standard (IS) and sodium hydroxide, plasma samples were extracted using 5 mL ethyl acetate. The compounds were separated on an Agilent Zorbax SB C18 column (100 mm × 2.1 mm ID, dp 3.5 μm) using an elution system of 10 mM ammonium acetate solution–methanol–formic acid (18:82:0.1, v/v) as the mobile phase. The quantification of target compounds was obtained by using multiple reaction monitoring (MRM) transitions: m/z 243.1, 210.1 and 267.2, 166.0 were measured in positive mode for huperzine A and IS. Linearity was established for the range of concentrations 0.01–4.0 ng mL?1 with a coefficient of correlation (r) of 0.9991. The lower limit of quantification (LLOQ) was identifiable and reproducible at 0.01 ng mL?1. The method has been successfully applied to study the pharmacokinetics of huperzine A in healthy male Chinese volunteers.  相似文献   

10.
A simple, rapid, specific and sensitive liquid chromatography–tandem mass spectrometric method has been developed and validated for the simultaneous estimation of alfuzosin and dutasteride in human plasma. Both alfuzosin and dutasteride were extracted from human plasma by solid-phase extraction using terazosin and finasteride as the internal standards for alfuzosin and dutasteride, respectively. Chromatographic separation of analytes and their respective internal standards was carried out using a Hypurity C18 (50 × 4.6 mm i.d., 5 μm particle size) column followed by detection using an applied biosystems API 5000 mass spectrometer with a UPLC as the front end. The method involves a rapid solid phase extraction from plasma, simple isocratic chromatographic conditions and mass spectrometric detection in the positive ionization mode using multiple reactions monitoring that enables detection down to low nanogram levels with a total run time of 2.5 min only. The method was validated over a range of 0.25–20.0 ng mL?1 for alfuzosin and 0.1–10.0 ng mL?1 for dutasteride. The absolute recoveries for alfuzosin (65.57%), dutasteride (103.82%), terazosin (69.38%) and finasteride (102.25%) achieved from spiked plasma samples were consistent and reproducible. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. Due to the short run time of 2.5 min it was possible to analyze a throughput of more than 180 human plasma samples per day. The validated method can be successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailabilty or bioequivalence studies. As an example the application of this validated method to a bioequivalence study is also illustrated.  相似文献   

11.
12.
13.
Monoethanol (MEA)- and dimethyl (DMA)-nitramines are by-products of amine-based post-combustion CO2 capture (PCCC) processing, and are potentially carcinogenic. The compounds are challenging to measure, also with LC–tandem mass spectrometry (MS/MS), attributed to their high polarity and extreme proneness to matrix effects. In contrast to related methods, the MEA- and DMA-nitramines were simultaneously determined in aqueous soil extracts in less than 10 min using a 1 mm × 150 mm Atlantis® T3 (3 µm) C18 column. A mobile phase of water/methanol (90/10, v/v) and 2 mM acetic acid allowed for electrospray ionization (ESI) of both analytes [in contrast to the need for both ESI and atmospheric pressure chemical ionization (APCI) in related methods]. Polarity switching electrospray was required for the simultaneous detection of the analytes, and concentration limits of detection (LODs) in the aqueous soil extracts were ≤5.0 µg L?1 using an injection volume of 20 μL and no prior enrichment step. Matrix effects were compensated for using isotope-labelled internal standards, and satisfactory precision and linearity were obtained (within- and between-day precisions ≤19%, r 2 ≥ 0.995 for concentrations up to 500.0 µg L?1). To avoid signal decrease over time when measuring DMA-nitramine alone, the use of polarity switching was beneficial, in addition to frequent cleaning of the ion transfer capillary. The validated method can be used to determine nitramines in aqueous soil extracts, which is of importance as soil sorption is a determinant of the compounds’ environmental fate.  相似文献   

14.
Cortisol homeostasis is implicated in hypertension and metabolic syndrome. Two enzymes modulate cortisol availability; 11β-hydroxysteroid dehydrogenase type 1 (11β-HSD1) preferentially converts inactive cortisone to cortisol, whereas 11β-hydroxysteroid dehydrogenase type 2 (11β-HSD2) converts cortisol to cortisone. In contrast, 5α and 5β reductases inactivate cortisol by conversion to its tetrahydrometabolites: tetrahydrocortisol, allo-tetrahydrocortisol and tetrahydrocortisone. A subtle local increase in cortisol can be detected by measuring 24-h urine metabolites, LC–MS/MS being the reference method. The 11β-HSD2 activity is assessed based on the cortisol/cortisone ratio, and the 11β-HSD1 activity on the (tetrahydrocortisol + allo-tetrahydrocortisol)/tetrahydrocortisone ratio. To better understand hypertension and/or metabolic syndrome pathogenesis a method for simultaneous determination of cortisol, cortisone, tetrahydrocortisol, allo-tetrahydrocortisol and tetrahydrocortisone was developed and validated in an LC coupled with the new detector AB Sciex QTrap® 4500 tandem mass spectrometer. The steroids were extracted from 1 mL urine, using cortisol-D4 as internal standard. The quantification range was 0.1–120 ng/mL for cortisol and cortisone, and 1–120 ng/mL for tetrahydrometabolites, with >89 % recovery for all analytes. The coefficient of variation and accuracy was <10 %, and 85–105 %, respectively. Our LC–MS/MS method is accurate and reproducible in accordance with Food and Drug Administration guidelines, showing good sensitivity and recovery. This method allows the assessment of 11β-HSD2 and 11β-HSD1 activities in a single analytical run providing an innovative tool to explain etiology of misclassified essential hypertension and/or metabolic syndrome.  相似文献   

15.
16.
17.
A sensitive and selective liquid chromatographic tandem mass spectrometric (LC–MS–MS) method was developed for simultaneous identification and quantification of tamsulosin and dutasteride in human plasma, which was well applied to clinical study. The method was based on liquid–liquid extraction, followed by an LC procedure with a Gemini C-18, 50 mm × 2.0 mm (3 μm) column and using methanol:ammonium formate (97:3, v/v) as the mobile phase. Protonated ions formed by a turbo ionspray in positive mode were used to detect analytes and internal standard. MS–MS detection was by monitoring the fragmentation of 409.1 → 228.1 (m/z) for tamsulosin, 529.3 → 461.3 (m/z) for dutasteride and 373.2 → 305.3 (m/z) for finasteride (IS) on a triple quadrupole mass spectrometer. The lower limit of quantification for both tamsulosin and dutasteride was 1 ng mL?1. The proposed method enables the unambiguous identification and quantification of tamsulosin and dutasteride for clinical drug monitoring.  相似文献   

18.
A simple, sensitive, selective and rapid liquid chromatography–tandem mass spectrometry method was developed and validated for the simultaneous separation and quantitation of atenolol and chlorthalidone in human plasma using metoprolol and hydrochlorothiazide as internal standard. Following solid phase extraction, the analytes were separated by an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the multiple reaction-monitoring mode (atenolol in positive and chlorthalidone in the negative ion mode). The limit of quantitation for this method was 10 and 15 ng mL?1 and the linear dynamic range was generally 10–2,050 ng mL?1 and 15–3,035 ng mL?1 for atenolol and chlorthalidone, respectively.  相似文献   

19.
A selective, sensitive and high throughput LC–MS–MS method has been developed and validated for the chromatographic separation and quantitation of tolterodine (TOL) and its metabolite 5-hydroxymethyl TOL in human plasma. Sample clean-up concerned liquid–liquid extraction of the drug, metabolite and their respective labelled internal standards from 300 μL human plasma. Both the analytes were chromatographically separated on a Symmetry C18 (100 mm × 4.6 mm, 5 μm particle size) analytical column using 10 mM ammonium formate (pH 5.0 ± 0.1, adjusted with formic acid) and acetonitrile (35:65, v/v) as the mobile phase with a resolution factor of 2.72. The method was validated over the concentration range of 0.025–10.0 ng mL?1 for both analytes. The process efficiency found for TOL and its metabolite was 98.3 and 99.5%, respectively. The method was successfully applied to a pivotal bioequivalence study in 41 healthy human subjects after oral administration of a 2 mg tablet formulation under fasting conditions.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号